26.08.2013 Views

Nico Zobel Technische Universität Berlin / Berlin ... - EVUR - TU Berlin

Nico Zobel Technische Universität Berlin / Berlin ... - EVUR - TU Berlin

Nico Zobel Technische Universität Berlin / Berlin ... - EVUR - TU Berlin

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Nico</strong> <strong>Zobel</strong><br />

<strong>Technische</strong> <strong>Universität</strong> <strong>Berlin</strong> / <strong>Berlin</strong> Institute of Technology<br />

Department of Energy Engineering<br />

Chair for Energy Process Technology and<br />

Conversion Technologies for Renewable Energies (<strong>EVUR</strong>)<br />

Fasanenstr. 89, D-10623 <strong>Berlin</strong><br />

nico.zobel@tu-berlin.de


Intention:<br />

time for complete analysis<br />

days<br />

hours<br />

minutes<br />

seconds<br />

Motivation<br />

SPA<br />

tar guideline<br />

SPA<br />

tar guideline<br />

GC-MS<br />

CON-TAR<br />

1000 10000 100000<br />

MBMS<br />

TOF-MS<br />

estimated equipment cost in EUR<br />

Field of application: research and industry,<br />

for permanent monitoring/control of gas quality<br />

08.06.2009 Gas Analysis Workshop @ 19th EU BC+E, <strong>Berlin</strong> 2011 2


calibration<br />

light source<br />

(LASER)<br />

CONTAR – CONtinuos TAR-analyzer<br />

principle setup<br />

sample exhaust<br />

measuring<br />

cell<br />

compact<br />

spektrometer<br />

USB<br />

beam-dump<br />

compakt-PC<br />

data I/O<br />

08.06.2009 Gas Analysis Workshop @ 19th EU BC+E, <strong>Berlin</strong> 2011 3<br />

USB<br />

signal<br />

(0-20 mA)


producer<br />

gas flow<br />

Sampling<br />

Possible impact of tar concentration gradient in pipe cross section<br />

particle<br />

filter<br />

Sampling line CON-TAR<br />

Impinger<br />

bottles<br />

08.06.2009 Gas Analysis Workshop @ 19th EU BC+E, <strong>Berlin</strong> 2011 4<br />

vent


intensity [counts, a. u.]<br />

600<br />

400<br />

200<br />

0<br />

Principle Results<br />

measured spectrum<br />

fitted spectrum<br />

fluorene<br />

naphthalene<br />

phenanthrene<br />

pyrene<br />

300 400 500 600<br />

wavelength [nm]<br />

08.06.2009 Gas Analysis Workshop @ 19th EU BC+E, <strong>Berlin</strong> 2011 5


Results and Exeriences<br />

Robustness: optical system + measuring cell very robust<br />

impinger bottles not practical, constant volume flow important<br />

Operation: can be learned within minutes<br />

Sensitivity: Naphthalene > 50 mg/Nm3, Phenol > 200 mg/Nm3 (?)<br />

Selectivity: depends on mixture, some fluorescence peaks overlap<br />

Repitition: results every 10 seconds<br />

Reproducibility: ?<br />

Stability: maximum continuous test duration: two weeks,<br />

no failures so far<br />

Benchmark: +/- 20% compared to GC/MS<br />

08.06.2009 Gas Analysis Workshop @ 19th EU BC+E, <strong>Berlin</strong> 2011 6


Status:<br />

Status<br />

• periphery not yet ready for fully automatic operation<br />

• rather costly parts for excitation (uv-laser) and detection (spectrometer);<br />

depending on desired details in measurement cost reduction possible<br />

Future work:<br />

(1) Improve periphery:<br />

- Replace impinger bottles & pump with ejector pump (+ burner)<br />

- Control sampling volume flow<br />

(2) Implementation and testing of less expensive light sources and detectors<br />

08.06.2009 Gas Analysis Workshop @ 19th EU BC+E, <strong>Berlin</strong> 2011 7


Thank you for yor attention!<br />

08.06.2009 Gas Analysis Workshop @ 19th EU BC+E, <strong>Berlin</strong> 2011 8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!