LI(UI-DIAL<br />

Liquid Conditioning Controls<br />

The CLAYTON 122 BRINE VALVE is used on brine measuring<br />

tanks to withdraw a measured amount of brine and then close. The<br />

brine measuring tank is refilled from a salt storage tank through<br />

a brine transfer valve, controlled by the 122 brine valve.<br />

The 122 Brine Valve is hydraulically operated by line pressure conditions<br />

and responds to commands from the pilot control. The<br />

control is actuated by a float which moves freely up and down on<br />

a float rod with changing liquid levels. Operating points are easily<br />

adjusted by varying the location of stop collars on the float rod.<br />

With the float in the high level position and the brine inlet line<br />

under vacuum, the 122 Brine Valve opens to allow a measured<br />

quantity of brine to be withdrawn and then closes. With the float<br />

in the low level position, the brine transfer valve is opened only<br />

after the system has completed the salt rinse step. When the brine<br />

reaches the high level in the measuring tank, the 122 Brine Valve<br />

closes the brine transfer valve.<br />

For installations where salt storage is provided in a tank separate<br />

from the brine measuring tank, the Clayton 122 Brine<br />

Control Valve offers a positive means of performing the<br />

functions of:<br />

1. Controlling the volume of brine to be withdrawn.<br />

2. Controlling brine tank refill from a salt storage tank.<br />

Only one ejector and ejector supply line is required on multiple<br />

tanks. The direction of the brine to the proper unit of a<br />

multiple unit installation is controlled by individual softener<br />

unit valves.<br />

Engineering Data<br />

BRINE CONTROL VALVE<br />

CLayton 122<br />

SIZES :V2" to 3" Screwed<br />

1" to 3" Flanged available<br />

PRESSURE CLASS 125 ASA and 250 ASA<br />

PRESSURE RATINGS ][iaximum<br />

250 ASA 300 psi<br />

TEMPERATURE RANGE --40 F. to + 160 F.<br />

CLUIDS Water and Salt Brine<br />

MATERIALS Main l/alve Bod and Cover:<br />

3" z/ Bronze ASTM B-61<br />

1" 3" Cast Iron ASTM A-48<br />

Main [/alve Trim<br />

Bronze ASTM B-61<br />

Pilot Control:<br />

Bronze ASTM B-61<br />

Pilot Control Trim:<br />

Stainless Steel Bar AISI 303<br />

Float Ball:<br />

Plastic<br />

Float Rod and Stol<br />

Plastic<br />

SPECIAL ATERIALS Cast steel, bronze and aluminum<br />

available at extra cost<br />

AnJUSTMENT ANGE 42" maximum.<br />

Automatically opens to allow a measured quantity of<br />

brine to be withdrawnand then closes.<br />

After the rinse operation, opens the brine transfer valve<br />

to fill the measuring tank from the salt storage. Closes<br />

the brine transfer valve when the brine measuring tank<br />

is filled.<br />

Volume of brine to be withdrawn can be adjusted by<br />

setting the float stop positions.<br />

Drip tight closure maintained after measuring tank<br />

refill.<br />

L-E-122 PATENTS ISSUED AND/OR PENDING ) CLA-VAL