14 - Preliminary Tests<br />

IV-PIACING INTO SERVICE<br />

Place the tubes in their sockets . Press push button<br />

to "MANUA L" pos ition. Operate toggle switch No. 1 on the control<br />

panel to the position as outlined in para graph 12 and operate the 10-pole transfer sw itch to the correspond ing pos ition. Inspect<br />

the scanner to see that the lenses are clean and that the<br />

mot or shaft is turning freely. Close the ac supply switch.<br />

While the synchronous motor is running disconnect the a-c . supply<br />

voltage and measure the time required for the motor to reacQ<br />

standstill. If this time is less than 8 sec onds , there is too<br />

much fric t ion in the motor bearings and the mot or bearings shoud<br />

be cleaned or replaced . Inspect the tubes to see that the filaments<br />

are glowing with a dull red glow , and ob serve that the<br />

lens es are rotating in direction as specified in table I of<br />

Drawing 2-A-4278 , viewing it from ins ide the scanner case when<br />

the door is open. Check to see that the d-c. revers ing motor<br />

field is supplied with voltage by ob serving tha t there is a<br />

bluish glow in the RCA-83 rectifier tube.<br />

Place a piece of the ma terial without any printing on<br />

the roll below the scanner and turn the potent iometer dial on the<br />

control panel "all inll clockwise to position 100. There should<br />

now be a bluish glow in tube II, and no glow in tube III . If<br />

there is a glow in tube III the scanner is not properly lined up<br />

in relation to the roll, or the ground connections are not properly<br />

made.<br />

15 - Operation of Tubes<br />

To test the operation of the scanner and tubes 'XI and<br />

III, place the material in its norma l position beneath the scanner.<br />

Turn potent iometer to position 100. Place the line or<br />

edge in the approximate diametrical center of the light circle<br />

and move to left and right . Ob serve tube II which should be liON"<br />

as indicated by a bluish glow or " OFF " approx imately within the<br />

regions as indicated by Fig. 1 and 2 of Drawing 2-A-4278 . It<br />

will be noted that tube II will be on or off if the line or edge<br />

is moved slight ly away from the diametrical pos ition. If this<br />

"ON - OFF II position is not approximately in the diametrical position<br />

the location can be changed by turning the lens holder<br />

slight ly in relation to the motor shaft, although this should<br />

not be necessary because adjustment of the lens holder ha s been<br />

made at the factory, and the correct posit ion of the lens holder<br />

is indicated by a mark on the motor shaft oppos ite a mark on the<br />

lens holder bushing .<br />

It may be found in some cases tha t more points of control<br />

ex ist than are shown in Fig. 1 and Fig. 2 of Drawing 2-A-7tB<br />

By turning the potent iometer towards zero this cond ition can be<br />

eliminated.<br />