18 - Adjus tment of Limit SW itches<br />

With the 'IO-pole transfer switch in the same position<br />

as toggle switch No . 1, "inch" motor along under manua l control<br />

by operating the "LEFT" or "RIGHT" push button unt il one l1niit<br />

switch is opened. If opening the limit switch does not stop<br />

motor travel, reverse connections to the limit switches.<br />

19 - Left, Right , Automatic , Manua l Push Buttons<br />

The IIAUTOMATIC" push button places the equipment under<br />

automatic control, with the "LEFT" and "RIGHT" push buttons permitting<br />

manua l control to bring the line or edge to the norma l<br />

operating posit ion. If the "MANUAL" push button is operated,<br />

only manua l control can be ob ta ined . If manua l control only is ·<br />

desired for any continued run the scanner should be moved so<br />

that the light circle falls entirely on the rubber roll .<br />

Wlth the 10-pole transfer switch in the same position<br />

as toggle switch No. 1 operate the push buttons and observe the<br />

operation of the motor. If necessary , interchange connections<br />

between right and left push buttons , to make the paper move to<br />

the right or left when viewing it from the finishing end of the<br />

winder.<br />

20 Connections of Jumper lI to Resistor Termina ls<br />

10.<br />

The two 10-inch resistor tubes mounted at the top of<br />

the panel are conneoted in series with the motor armature . By<br />

short-circuit ing part of these resistors it is possible to in­<br />

crease the response of the reversing motor. It should be noted<br />

that under no circumstances should more than two sections of the<br />

resistors be short-'9 ircuited as this would damage the KU-628<br />

tubes . The machine has been previously operated and the ,Q:onnec­<br />

tion giving satisfactory torque ha s been indicated and left thus<br />

connected . However, if different respons e or rate of connection<br />

is needed jump er 11 may be connected to a different resis.tor ter­<br />

mina l .<br />

21 - Reconnection of Scanner for Light or Dark Operation<br />

As shown in draw ing 2-A-4278 the scanner switch shOUld<br />

be 0perated to I I DARKII or "LIGHT " position as indicated in<br />

Table 1.<br />