12.10.2013 Views

MODEL 300MB-SD - Federal Signal

MODEL 300MB-SD - Federal Signal

MODEL 300MB-SD - Federal Signal

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

256A1078H<br />

REV H 1009<br />

Printed in U.S.A.<br />

<strong>MODEL</strong> <strong>300MB</strong>-<strong>SD</strong><br />

CommCenter<br />

Series D1<br />

INSTALLATION AND SERVICE INSTRUCTIONS


Warranty – Seller warrants all goods for five years on parts and 2-1/2 years on labor, under the following<br />

conditions and exceptions: Seller warrants that all goods of Seller's manufacture will conform to<br />

any descriptions thereof for specifications which are expressly made a part of this sales contract and at<br />

the time of sale by Seller such goods shall be commercially free from defects in material or workmanship.<br />

Seller reserves the right at the Seller’s discretion to “Repair and Return” or “Replace” any item<br />

deemed defective during the warranty period. This warranty does not cover travel expenses, the cost of<br />

specialized equipment for gaining access to the product, or labor charges for removal and reinstallation<br />

of the product. This warranty shall be ineffective and shall not apply to goods that have been subjected<br />

to misuse, neglect, accident, damage, improper maintenance, or to goods altered or repaired by anyone<br />

other than Seller or its authorized representative, or if five years have elapsed from the date of shipment<br />

of the goods by Seller with the following exceptions: lamps and strobe tubes are not covered under this<br />

warranty. Outdoor warning sirens and controllers manufactured by <strong>Federal</strong> Warning Systems are warranteed<br />

for two years on parts and one year on labor. No agent, employee, representative or distributor<br />

of Seller has any authority to bind the Seller to any representation, affirmation, or warranty concerning<br />

the goods and any such representation, affirmation or warranty shall not be deemed to have become a<br />

part of the basics of the sales contract and shall be unenforceable. THE FOREGOING WARRANTIES<br />

ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR MERCHANTABILITY,<br />

FITNESS FOR PURPOSE AND OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED.<br />

These warranties shall not apply unless Seller shall be given reasonable opportunity to investigate all<br />

claims for allegedly defective goods. Upon Seller's instruction a sample only of allegedly defective<br />

goods shall be returned to Seller for its inspection and approval. The basis of all claims for alleged defects<br />

in the goods not discoverable upon reasonable inspection thereof pursuant to paragraph 8 hereof<br />

must be fully explained in writing and received by Seller within thirty days after Buyer learns of the<br />

defect or such claim shall be deemed waived.<br />

2645 <strong>Federal</strong> <strong>Signal</strong> Drive • University Park, IL 60466<br />

Tel: 708-534-4756 • Fax: 708-534-4852<br />

elp@fedsig.com • www.federalsignal-indust.com


TABLE OF CONTENTS<br />

Paragraph Page<br />

SECTION I - GENERAL DESCRIPTION<br />

1-1 General ................................................................................................................... 1-1<br />

1-2 Chassis Description................................................................................................ 1-1<br />

SECTION II - SPECIFICATIONS<br />

2-1 Power Input ............................................................................................................ 2-1<br />

2-2 Emergency Power Source Input ............................................................................ 2-1<br />

2-3 Audio/Cascade Input .............................................................................................. 2-1<br />

2-4 Audio Outputs ........................................................................................................ 2-1<br />

2-5 Remote Tone Activation Circuit ............................................................................ 2-2<br />

2-6 Physical ................................................................................................................... 2-2<br />

SECTION III - INSTALLATION<br />

3-1 Unpacking .............................................................................................................. 3-1<br />

3-2 Kit Contents ........................................................................................................... 3-1<br />

3-3 Input Configuration ............................................................................................... 3-1<br />

3-4 Control Circuitry .................................................................................................... 3-1<br />

3-5 Power ...................................................................................................................... 3-2<br />

3-6 Audio Input............................................................................................................. 3-2<br />

3-7 <strong>Signal</strong> Lines ............................................................................................................ 3-3<br />

3-8 Model <strong>300MB</strong> <strong>Signal</strong> Connections ........................................................................ 3-3<br />

3-9 Connection to Remote Devices .............................................................................. 3-3<br />

3-10 <strong>300MB</strong> Power Connections .................................................................................... 3-4<br />

3-11 Typical Installations .............................................................................................. 3-4<br />

3-12 Storage Chip Installation ...................................................................................... 3-7<br />

SECTION IV - SERVICE<br />

4-1 General ................................................................................................................... 4-1<br />

4-2 Replacement Parts ................................................................................................. 4-1


1-1. GENERAL.<br />

The CommCenter, Model <strong>300MB</strong> Series D, is a digital<br />

playback device that is capable of generating up to<br />

six different prerecorded voice messages, melodies, tones<br />

and/or signals. This central control device interfaces<br />

with any decentralized or centrally amplified system.<br />

The CommCenter can control signal lines to <strong>Federal</strong><br />

<strong>Signal</strong> SelecTone® Models 300GC, 300GCX, 300X,<br />

302GC, 302GCX, 302X, and 50GC speaker/amplifiers.<br />

It can also interface with any SelecTone Control Unit,<br />

Models 300VSC-1 or 300SCW-1. It can directly drive<br />

speakers designed for 25Vrms line operation. It can<br />

also provide a 1Vp-p audio signal, and can be used as a<br />

remote audio input for a public address sound system.<br />

Using the <strong>300MB</strong>’s cascading function, CommCenters<br />

can be linked together to provide a system with the<br />

capability of more than six messages.<br />

NOTE<br />

The CommCenter accepts messages stored on ICs<br />

and pluggable circuit boards. Both are referred to<br />

as message chips in this manual.<br />

The messages stored on pluggable circuit boards<br />

will operate on all Series B, Series C, and Series D<br />

Models.<br />

The Series D CommCenters use a different storage<br />

IC than the Series A, Series B, and Series C.<br />

These ICs cannot be interchanged between Series<br />

A, Series, B, and Series C models.<br />

Make sure to specify which series CommCenter<br />

you have before ordering any additional messages.<br />

The CommCenter is intended to be installed in<br />

indoor (NEMA 1) or other protected installations only.<br />

It can be mounted on any horizontal or vertical surface<br />

using #10 screws, appropriate for the type of mounting<br />

surface material, and the four mounting holes in the<br />

<strong>300MB</strong>’s housing (see figure 1-1).<br />

1.08<br />

2.86<br />

3.57<br />

KNOCKOUT PROVISION 0.87 DIA., 5 PLACES<br />

FIELD WIRING BLOCK FOR 120/240V POWER<br />

CONNECTION<br />

2.27<br />

1.06<br />

SECTION I<br />

GENERAL DESCRIPTION<br />

9.41<br />

2.20<br />

6.77<br />

1.28<br />

3<br />

1.18 9.75<br />

1-1<br />

The CommCenter can be used for a variety of prioritized<br />

signaling purposes, such as indicating the status<br />

of a machine or process, background messages, evacuation,<br />

alarm, start and dismissal, and other audible<br />

notification applications. The system can be automated<br />

if external (customer-supplied) devices such as programmable<br />

controllers, heat detectors, switches or program<br />

clocks are connected to the remote inputs. This product<br />

is not listed for fire use.<br />

A CommCenter plays and amplifies messages<br />

through signal lines to the remote SelecTone devices in<br />

the system. To connect the SelecTone speaker/amplifier<br />

to the signal line, a Model 300CK Connector Kit is<br />

required in each SelecTone device. Speakers designed<br />

for 25 volt operation can connect directly to the 25 volt<br />

output.<br />

Each message can be activated by a contact closure<br />

or opening at its associated remote control input. The<br />

remote control inputs can be configured to work with<br />

either latching or momentary contacts.<br />

1-2. CHASSIS DESCRIPTION.<br />

The CommCenter is assembled in a black, powdercoated<br />

steel, 2-piece housing. The cover is attached to<br />

the housing with four screws, two along each long edge<br />

of the enclosure. The rear of the housing incorporates<br />

two field wiring compartments baffled off from the<br />

printed circuit board area. One compartment is for the<br />

connection of the Class II power and signal lines, and<br />

the other is for the connection of the Class I power lines.<br />

These areas are provided with knock-outs to allow the<br />

external wiring to enter the unit through appropriate<br />

installer-supplied bushings.<br />

Each CommCenter can accommodate up to six storage<br />

chips, selected from a library of prerecorded voice<br />

messages, melodies, tones and/or signals. There is one<br />

message per storage chip. Each chip plugs into a 28-pin<br />

IC socket. The six sockets are labeled Priority Tone 1<br />

through Priority Tone 6 (see figure 1-2).<br />

11.57<br />

4 1<br />

Figure 1-1. Mounting Holes and Dimensions.<br />

2<br />

2.15<br />

6.87<br />

COVER REMOVED<br />

TO SHOW FOUR<br />

MOUNTING HOLES<br />

0.20 DIA., FOR<br />

#10 SCREWS<br />

290A2664-18


C7<br />

C9<br />

C13<br />

C129 R69<br />

R68<br />

R67<br />

+<br />

C115<br />

+<br />

C97<br />

+<br />

+ C128<br />

C96 C112<br />

C5<br />

IC25<br />

IC25<br />

IC12<br />

IC16<br />

+<br />

STD<br />

R1<br />

IC7<br />

IC9<br />

IC4<br />

R101<br />

R132<br />

PRIORITY<br />

TONE 2<br />

R123<br />

PRIORITY<br />

TONE 3<br />

PRIORITY<br />

TONE 4<br />

R131<br />

PRIORITY<br />

TONE 5<br />

IC17 R126<br />

+<br />

TB1<br />

CR7<br />

CR11<br />

J1<br />

C127<br />

IC24<br />

1<br />

IC24<br />

R12<br />

PRIORITY<br />

TONE 1<br />

R136<br />

R127<br />

R117<br />

C125<br />

R10<br />

R11<br />

R13<br />

R135<br />

C8<br />

R120<br />

PRIORITY<br />

TONE 6<br />

R116<br />

ALT<br />

C6<br />

C10<br />

R66 C14<br />

C111<br />

C94<br />

C108<br />

C92<br />

C11<br />

C15<br />

1<br />

R110<br />

R102<br />

R134<br />

R129<br />

R125<br />

R122<br />

R115<br />

R111<br />

R113<br />

R128<br />

C121<br />

C106<br />

C89<br />

C120<br />

R133<br />

C104<br />

R124<br />

R119<br />

C88<br />

IC5<br />

U4<br />

U2<br />

U5<br />

R112 U1<br />

CR10<br />

CR13<br />

IC1<br />

U6<br />

R14<br />

C16<br />

C93<br />

IC17<br />

C118<br />

IC22<br />

IC22<br />

IC16<br />

C124<br />

U3<br />

R15<br />

C107<br />

R114<br />

C119<br />

IC7<br />

C126<br />

IC9<br />

C110<br />

IC12<br />

C91<br />

R94<br />

C116<br />

C17<br />

+<br />

C133<br />

C102 C117<br />

+<br />

C87<br />

+<br />

+<br />

C132<br />

+<br />

CR1<br />

C2<br />

C12 R90 R91 TB3<br />

R95 R96<br />

C109<br />

C131<br />

R130<br />

C103 C130<br />

C114<br />

R118<br />

C100<br />

C122<br />

R61<br />

R63<br />

C105<br />

R76<br />

C113<br />

C86<br />

C99<br />

C95<br />

+<br />

R109<br />

C98<br />

C123<br />

R99<br />

R108<br />

R121<br />

C101<br />

C90<br />

R65<br />

R83<br />

R92<br />

C24<br />

CR8<br />

CR9<br />

R2<br />

IC6<br />

R19<br />

R21<br />

R105<br />

IC13<br />

R100<br />

R78<br />

R106<br />

IC19<br />

R74<br />

R79<br />

C1<br />

R16<br />

R60<br />

R62<br />

IC23<br />

R J6 M 1R<br />

J7 M R J8 M<br />

NO NO<br />

J9 NC J10 NC NO J11 NC<br />

R J12 M R J14 M R J13 M<br />

R103<br />

R72<br />

R82<br />

R75 R88<br />

R58<br />

TONE1<br />

C46<br />

R3<br />

NO J3 NC NO J4 NC NO J5 NC<br />

TONE6<br />

R70<br />

IC10<br />

R80<br />

R84<br />

IC11<br />

TONE5<br />

TONE2<br />

C45<br />

R81<br />

R107 R104<br />

R59<br />

R73<br />

R89<br />

R87<br />

CR6<br />

R20<br />

TONE3<br />

R93<br />

R97<br />

C49<br />

C48<br />

R45<br />

R46<br />

Figure 1-2. Model <strong>300MB</strong> Series D Mother Board.<br />

1-2<br />

C47<br />

R77<br />

IC2<br />

TONE4<br />

+<br />

R4<br />

R5<br />

R17 R18<br />

IC8<br />

R31<br />

R32<br />

C37<br />

R33<br />

R34<br />

R35<br />

R71<br />

IC18<br />

C84<br />

C85<br />

R22<br />

R6<br />

R7<br />

C18<br />

C77<br />

R44<br />

V<br />

O<br />

L<br />

I<br />

V<br />

C3<br />

C78<br />

C29<br />

L1<br />

+<br />

R8<br />

IC14<br />

T1<br />

1<br />

CR3<br />

R36<br />

R26<br />

IC20<br />

K1<br />

C50<br />

C51<br />

C79<br />

K2<br />

C38<br />

CR12<br />

R47<br />

C68<br />

C73<br />

CR4<br />

R37<br />

CR2<br />

C53<br />

C52<br />

+<br />

C80<br />

C4<br />

C31<br />

Q2<br />

C69<br />

C82<br />

JU3<br />

Q1<br />

C39<br />

R48<br />

C74<br />

R39<br />

R40<br />

C54<br />

R49<br />

C70<br />

C30<br />

IC15<br />

C75<br />

J2<br />

R27<br />

C81<br />

R9<br />

IC21<br />

C83<br />

TB2<br />

JU1<br />

B W<br />

JU2<br />

CR5<br />

Q3<br />

GMC-1/2A<br />

F2<br />

GMC-1A<br />

C32<br />

C55<br />

R28<br />

C71<br />

R51<br />

C72<br />

C76<br />

F1<br />

SW1<br />

R50<br />

R52<br />

290A2922B<br />

200D1148 G 250V 240V 120V 250V


2-1. POWER INPUT.<br />

SECTION II<br />

SPECIFICATIONS<br />

A. Input Voltage ................................................................................ 120/240 V, 50/60 Hz<br />

B. Standby Current .......................................................................... 50 mA 120 Vac<br />

C. Operating Current ...................................................................... 210 mA (MAX)<br />

D. Power Consumption ..................................................................... 26 W (MAX)<br />

2-2. EMERGENCY POWER SOURCE INPUT.<br />

A. Input Voltage ................................................................................ 22–32 Vdc<br />

B. Standby Current .......................................................................... 90 mA<br />

C. Operating Current ....................................................................... 760 mA<br />

2-3. AUDIO/CASCADE INPUT.<br />

Cascade Input<br />

Input Impedance ................................................................................. 5k ohms<br />

Input Voltage ....................................................................................... 1 V p-p (MAX)<br />

2-4. AUDIO OUTPUTS.<br />

A. Output Impedance<br />

Unbalanced Sig. Line ............................................................. 25 ohms (MAX)<br />

Unbalanced Sig. Line Standby ............................................... 120 ohms<br />

Balanced Sig Line ................................................................... 40 ohms (MAX)<br />

Low Level Sig. Out ................................................................. 600 ohms<br />

B. Output Voltage Levels No Load (


2-5. REMOTE TONE ACTIVATION CIRCUIT.<br />

Message can be initiated by connecting the initiating line to CommCenter Ground by means of a dry<br />

contact or open collector.<br />

2-6. PHYSICAL.<br />

Weight ........................................................................................... Shipping 6-5/8 lb (3.01 kg)<br />

Net 5-1/2 lb (2.49 kg)<br />

Dimensions (HWD) ...................................................................... 2.28" x 9.41" x 11.57"<br />

Operating Temperature ............................................................... 32°F (0°C) to 120°F (49°C)<br />

2-2


Failure to follow all safety precautions and<br />

instructions may result in property damage,<br />

serious injury, or death to you or others.<br />

SAFETY MESSAGE TO INSTALLERS<br />

Peoples lives depend on your safe installation of our<br />

products. It is important to follow all instructions shipped<br />

with the products. This device is to be installed by a trained<br />

electrician who is thoroughly familiar with the National<br />

Electric Code and will follow the NEC guidelines as well as<br />

local codes.<br />

The selection of the mounting location for the device,<br />

its controls and the routing of the wiring is to be accomplished<br />

under the direction of the Facilities Engineer and<br />

the Safety Engineer. In addition, listed below are some<br />

other important safety instructions and precautions you<br />

should follow:<br />

• Although your signaling system is working properly,<br />

it may not be completely effective. People may not hear or<br />

heed your warning signal. You must reconize this fact and<br />

proceed with due caution.<br />

• Read and understand all instructions before installing<br />

or operating this equipment.<br />

• Do not connect or service this unit when power is on.<br />

• Optimum sound distribution will be severely reduced<br />

if any objects are in front of the speaker. You should ensure<br />

that the front of the speaker is clear of any obstructions.<br />

• All effective warning speakers produce loud sounds<br />

which may cause, in certain situations, permanent hearing<br />

loss. You should take appropriate precautions such as wearing<br />

hearing protection.<br />

• All effective warning speakers produce loud sounds,<br />

which may cause, in certain situations, permanent hearing<br />

loss. The device should be installed far enough away<br />

from potential listeners to limit their exposure while still<br />

maintaining its effectiveness. The OSHA Code of <strong>Federal</strong><br />

Regulations 1910.95 Noise Standard provides guidelines<br />

which may be used regarding permissible noise exposure<br />

levels.<br />

• After installation, test the sound system to ensure<br />

proper operation.<br />

• Show these instructions to your Safety Engineer and<br />

all operating personnel and then file them in a safe place<br />

and refer to them when maintaining and/or reinstalling the<br />

unit.<br />

• Establish a procedure to routinely check the sound<br />

system for proper activation and operation.<br />

SECTION III<br />

INSTALLATION<br />

3-1<br />

3-1. UNPACKING.<br />

After unpacking the Model <strong>300MB</strong>, examine<br />

it for damage that may have occurred in transit. If<br />

the equipment has been damaged, do not attempt to<br />

install or operate it, file a claim immediately with the<br />

carrier stating the extent of the damage. Carefully<br />

check all envelopes, shipping labels and tags before<br />

removing or destroying them. Before attempting to<br />

install the CommCenter, be sure that all parts listed<br />

in the KIT CONTENTS LIST have been supplied.<br />

3-2. KIT CONTENTS.<br />

Qty. Description Part No.<br />

1 Plug, 10 Position 140A332-10<br />

1 Plug, 17 Position 140A332-17<br />

3-3. INPUT CONFIGURATION.<br />

The CommCenter can be configured for remote<br />

activation in four ways:<br />

• Normally open latching contacts.<br />

• Normally open momentary contacts.<br />

• Normally closed latching contacts.<br />

• Normally closed momentary contacts.<br />

The unit is factory set to be activated by closing<br />

a normally open latching contact between the<br />

associated input and circuit ground. When activated<br />

the message will continue to loop and repeat. It will<br />

stop as soon as it is deactivated. When configured for<br />

momentary activation, the message will continue to<br />

loop and repeat until the input is deactivated. Upon<br />

deactivation of the input, it will play the entire message<br />

before stopping.<br />

Each of the six inputs can be individually configured<br />

by moving a two position jumper on a three<br />

position header. See table 3-1 for a list of the Priority<br />

Tones, their associated jumper designation and their<br />

marking as shown on the printed circuit board silkscreen.<br />

3-4. CONTROL CIRCUITRY.<br />

A. The control circuitry in the CommCenter<br />

has a built-in priority level feature. If a given message<br />

is already sounding when a higher priority<br />

message is activated, the higher priority message<br />

automatically overrides the lower priority message.<br />

When the higher priority message is deactivated, the<br />

lower priority message is initiated as long as it is still<br />

activated. The messages are prioritized with Priority<br />

Tone 1 having the highest priority down to Priority<br />

Tone 6. The cascade input has the lowest level of<br />

priority.


MESSAGE Jumper Marking Jumper Marking<br />

PRIORITY J9 NO NC J12 R M<br />

TONE1<br />

PRIORITY J10 NO NC J14 R M<br />

TONE 2<br />

PRIORITY J11 NO NC J13 R M<br />

TONE 3<br />

PRIORITY J5 NO NC J8 R M<br />

TONE 4<br />

PRIORITY J4 NO NC J7 R M<br />

TONE 5<br />

PRIORITY J3 NO NC J6 R M<br />

TONE 6<br />

Notes: 1. NO NC configures an individual channel<br />

to interface to normally open (NO) or normally<br />

closed (NC) contacts.<br />

2. R M configures an individual channel<br />

to interface to a latched contact (R) or a momentary<br />

contact (M).<br />

Table 3-1.<br />

B. A message can be activated from the<br />

tone activation inputs on TB1. A dry contact, either<br />

normally open or normally closed depending on the<br />

configuration, connected between the associated message<br />

(TB1-1 through TB1-6) and COM (TB1-7) will<br />

activate a tone. The configuration of these channels<br />

is described in paragraph 3-3. These inputs are opto<br />

coupled to reduce the possibility of noise on the signal<br />

lines falsely activating a message.<br />

C. There are two sets of contacts which can be<br />

used to monitor the status of a CommCenter. When<br />

power is applied, a relay with form C contacts is<br />

activated. These contacts are connected to TB2 and<br />

are labeled Power Monitor Relay. The second set of<br />

contacts monitor activation of any of the six messages<br />

or a cascaded input. These contacts are labeled Push<br />

To Talk (PTT) on TB1.<br />

Do not perform any installation or maintenance<br />

to the system when power is on.<br />

3-5. POWER.<br />

In order to prevent power to a CommCenter<br />

from being turned off accidentally, the unit does not<br />

have a power switch. A <strong>300MB</strong> can be operated on<br />

either 120VAC, 50/60 HZ or 24VDC input power.<br />

3-2<br />

Failure to follow all safety precautions and<br />

instructions may result in property damage<br />

serious injury, or death to you or others.<br />

Do not perform any installation or maintenance<br />

on this system when power is on.<br />

This device is to be installed by a trained electrician<br />

who is thoroughly familiar with the<br />

National Electrical Code and will follow the<br />

NEC guidelines as well as local codes.<br />

The selection of the mounting location for this<br />

device, its controls, power supplied, and the<br />

routing of the wiring is to be accomplished<br />

under the direction of the facilities engineer<br />

and the safety engineer.<br />

If operation on 120VAC is desired, 120VAC is<br />

input through the 3-position field wiring terminal<br />

block located at the back of the unit. Two knock-out<br />

openings are provided. One knock-out should be<br />

removed and provided with a bushing through which<br />

the power lines can be routed into the field wiring<br />

compartment. The <strong>300MB</strong> is factory set for 120VAC<br />

operation. If operation on 240VAC is desired, switch<br />

SW1 must be set to the 240V position.<br />

If operation on 24VDC is desired, 24VDC is input<br />

on the two terminals shown in figure 3-1. Remove<br />

the labeled jumper from terminals TB2-7 and TB2-8<br />

of terminal block TB2, before using these positions. If<br />

24VDC operation is chosen, a Class II power supply<br />

and its associated wiring should be installed. Refer to<br />

paragraph 3-4.D. if the power down option is desired.<br />

3-6. AUDIO INPUT.<br />

There is a provision for a low level, low impedance<br />

audio signal input at the rear of the unit. It has<br />

been designed to accept a cascaded input from a slave<br />

CommCenter, TB2-1, but it could be audio from a<br />

telephone system, radio receiver, CD player, or tape<br />

player. When the enable pin on the cascade input is<br />

pulled to circuit ground, TB2-2, audio on the cascade<br />

in signal line is gated through the CommCenter and<br />

output on the signal lines. As stated before, this input<br />

is the lowest priority. The audio level input should be<br />

1Vp-p. When cascading units, connect the slave unit’s<br />

enable signal out terminals to the master unit’s


GND<br />

enable and signal in terminals. The SIG COM terminals<br />

(TB1-16) of both uinits also need to be connected<br />

together as shown in figure 3-2.<br />

3-7. SIGNAL LINES.<br />

120/240 VAC<br />

CLASS I FIELD WIRING<br />

COMPARTMENT<br />

NOT USED<br />

NOT USED<br />

The signal lines transfer the messages from a<br />

CommCenter to the remote SelecTone devices. In<br />

order to reduce the possibility of cross talk, hum, and<br />

static noise pick-up, the signal lines must be twisted<br />

pair audio cable. In the majority of systems, use<br />

AWG 18 twisted pair audio cables. Shielded, twisted<br />

pair cable is recommended when the Class II signal<br />

circuit is in the vicinity of welding equipment, carbon<br />

arc equipment, or similar electrical devices. Never<br />

use a cable having wire smaller than AWG 22.<br />

<strong>Federal</strong> <strong>Signal</strong> Corporation does not recommend<br />

that new or existing telephone lines be<br />

used as signal lines in a SelecTone system for<br />

the following reasons:<br />

1. Interference from other services or<br />

systems, or interference from the<br />

system to other services.<br />

2. Cross talk, interference, or hum<br />

induced by other telephone lines.<br />

+ 24VDC<br />

- 24VDC<br />

POWER DOWN<br />

3. Extended downtime because of the<br />

second party involvement required to<br />

service the lines.<br />

POWER<br />

MONITOR<br />

RELAY<br />

NO<br />

NC<br />

COM<br />

KNOCK-OUTS IN REAR OF HOUSING<br />

CASCADE<br />

IN<br />

ENABLE<br />

SIGNAL<br />

Figure 3-1. Model <strong>300MB</strong> Rear View.<br />

3-3<br />

OUTPUT LEVEL<br />

MIC OUT<br />

SIG COM<br />

SIG HI<br />

SIG<br />

25 VRMS<br />

LINE<br />

SIG<br />

CASCADE<br />

OUT<br />

SIGNAL<br />

ENABLE<br />

PTT<br />

RELAY<br />

COM<br />

NC<br />

NO<br />

COM<br />

MESSAGE 1<br />

MESSAGE 2<br />

MESSAGE 3<br />

MESSAGE 4<br />

MESSAGE 5<br />

MESSAGE 6<br />

TB2 TB1<br />

10 9 8 7 6 5 4 3 2 1 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1<br />

<strong>MODEL</strong> <strong>300MB</strong> REAR VIEW<br />

(BACK OF HOUSING IS REMOVED FOR CLARITY)<br />

CLASS II FIELD WIRING<br />

COMPARTMENT<br />

290A2923<br />

4. The additional cost of installation,<br />

interfacing devices and monthly<br />

charges as opposed to a one-time cost<br />

of performing the installation.<br />

3-8. <strong>MODEL</strong> <strong>300MB</strong> SIGNAL CONNECTIONS.<br />

Mixing signal lines with power lines could<br />

cause electrical interference, which could<br />

impede or render the system inoperable. Do<br />

not install signal lines in the same conduit<br />

with power lines.<br />

To connect the signal lines of the SelecTone system<br />

to the <strong>300MB</strong>, connect a color coded twisted pair<br />

of audio cables having conductors no smaller than 18<br />

AWG to SIG HI (TB1-15) and SIG COM (TB1-16) terminals<br />

on TB1 (see figure 3-1). Every remote Selec-<br />

Tone signaling device in the system will be connected<br />

in parallel to these lines. When connecting the remote<br />

devices in parallel to the signal lines, observe the<br />

correct polarity and install wire nuts over the connections.<br />

The yellow wires on the 300CK should be<br />

connected to the SIG HI while the blue wires should<br />

be connected to SIG COM.<br />

The 25Vrms speaker output is available at<br />

TB1-13 and TB1-14 for direct connection to ceiling<br />

speakers (see figure 3-1). Remove the labeled jumper<br />

from terminals TB1-13 and TB1-14 of terminal block<br />

TB1, before using these positions. <strong>Signal</strong> line losses


GROUND<br />

ENABLE<br />

SIGNAL<br />

CASCADE IN<br />

120/240 VAC<br />

10 2 1<br />

GAIN<br />

17 16 15<br />

CNTR<br />

1<br />

TB-2 TB-1<br />

GROUND<br />

SIG. HI (YEL)<br />

COM. (BLU)<br />

120/240 VAC<br />

CASCADE<br />

OUT<br />

SIGNAL<br />

ENABLE<br />

MASTER<br />

GAIN<br />

10 1 CNTR 16 12 11 1<br />

TB-2<br />

TB-1<br />

need to be considered when calculating how many<br />

speakers can be connected to the <strong>300MB</strong>.<br />

3-9. CONNECTION TO REMOTE DEVICES.<br />

Physically install the remote SelecTone<br />

device(s). Follow the installation instructions packed<br />

with the device.<br />

A. 300GC, 300GCX, 300X, 302GC, 302GCX,<br />

302X and 50GC.<br />

<strong>MODEL</strong> <strong>300MB</strong><br />

A 300CK Printed Circuit Connector Board<br />

is required to connect a 300GC, 300GCX, 300X,<br />

302GC, 302GCX, 302X or 50GC to the signal lines.<br />

The 300CK properly terminates the signal lines to<br />

the amplifier in the 300GC, 300GCX, 300X, 302GC,<br />

302GCX, 302X and 50GC. As shown in figure 3-3,<br />

connect the blue wire on the 300CK to the COM.<br />

wire from the <strong>300MB</strong>. Connect the yellow wire on the<br />

300CK to the SIG. HI wire from the <strong>300MB</strong>.<br />

300GC<br />

300CK<br />

YEL BLU YEL BLU<br />

16 15<br />

COM SIG<br />

HI<br />

TERMINAL BLOCK (TB1)<br />

ON REAR OF <strong>300MB</strong><br />

300GC<br />

300CK<br />

Figure 3-3. 300CK Connections.<br />

SIGNAL LINES SHIELDED<br />

TWISTED PAIR<br />

3-4<br />

SLAVE<br />

<strong>MODEL</strong><br />

300GC<br />

<strong>MODEL</strong><br />

300CK<br />

<strong>MODEL</strong> <strong>300MB</strong><br />

YEL<br />

BLU<br />

Figure 3-2. Cascading Multiple Units.<br />

SHIELDED<br />

TWISTED PAIR<br />

SIGNAL LINE<br />

TO ADDITIONAL<br />

SELECTONES<br />

290A2664-17<br />

POWER LINES<br />

120 VAC 120 VAC<br />

LOCAL PWR. LOCAL PWR.<br />

B. 25 Vrms <strong>Signal</strong> Line Application.<br />

290A2718<br />

The CommCenter has provision for connecting<br />

25 Vrms line operated speakers to its output.<br />

Connect the 25 Vrms line at terminals TB1-13 and<br />

TB1-14 of terminal block TB1. Remove the labeled<br />

jumper from terminals TB1-13 and TB1-14 of terminal<br />

block TB1. Connect the speakers in parallel to<br />

this line using 25 Vrms line tap. This output is to be<br />

used only if there are no SelecTone system devices<br />

connected across TB1-15 and TB1-16. This output<br />

is not switched like SelecTone system output across<br />

terminals TB1-15 and TB1-16.<br />

C. Low Level Audio Output.<br />

The <strong>300MB</strong> also has a 1 volt peak-to-peak<br />

audio output that can be connected to the audio input<br />

of another amplifier. This low level output is available<br />

across terminals TB1-16 and TB1-17 and is labeled<br />

as MIC OUT. It can also be connected to an analog<br />

fiber optic transmitter, allowing audio to be transmitted<br />

over a fiber optic link in an electrically noisy<br />

environment.<br />

3-10. <strong>300MB</strong> POWER CONNECTIONS.<br />

Mixing signal lines with power lines could<br />

cause electrical interference, which could<br />

impede or render the system inoperable. Do<br />

not install power lines in the same conduit as<br />

signal lines.<br />

Operating power is connected to the <strong>300MB</strong><br />

through the 3-position field wiring terminal block lo


cated at the back of the unit. Two knock-out openings<br />

are provided. One knock-out should be removed and<br />

provided with a bushing through which the power<br />

lines can be routed into the field wiring compartment.<br />

If it is desired to use 24 VDC either as a primary<br />

or auxiliary source of power, remove the labeled<br />

jumper from terminals TB2-8 and TB2-7 of terminal<br />

block TB2. Connect the “+” terminal of 24 volt DC<br />

power supply to the terminal TB2-8 (+24 VDC) and<br />

“-” terminal of the 24 VDC power supply to the terminal<br />

TB2-7 of the TB2 terminal block located in the<br />

back of the <strong>300MB</strong> (see figure 3-4).<br />

GROUND<br />

10 8 7 1 GAIN 171615 1<br />

CNTR<br />

TB-2 TB-1<br />

GROUND<br />

24 VDC<br />

POWER<br />

SUPPLY<br />

120/240 VAC<br />

CKT. 1<br />

CKT. 2<br />

+<br />

-<br />

+<br />

-<br />

NOT USED WITH <strong>MODEL</strong> PS300<br />

10 1 GAIN 171615 1<br />

CNTR<br />

TB-2 TB-1<br />

SIGNAL LINES SHIELDED<br />

TWISTED PAIR<br />

120/240 VAC<br />

SIGNAL LINES SHIELDED<br />

TWISTED PAIR<br />

Figure 3-4. Typical Central Power System.<br />

<strong>MODEL</strong> <strong>300MB</strong><br />

SIG. HI (YEL)<br />

COM. (BLU)<br />

Figure 3-5. Typical Selectone Installation.<br />

3-5<br />

3-11. TYPICAL INSTALLATIONS.<br />

A. SelecTone Installation (see figure 3-5).<br />

In this installation, the CommCenter is acting<br />

as a Selectone Control Center driving a 10Vrms<br />

signal line. Remote Speaker/Amplifiers have the<br />

signal coupled in through a 300CK.<br />

B. <strong>300MB</strong> Interface with a 300VSC-1,<br />

300SCW-1, 300SSC (see figure 3-6 and<br />

table 3-2).<br />

In this installation the CommCenter is<br />

acting as a remote microphone audio input and adds<br />

message playback capability to a Selectone system.<br />

The gain adjustment on the <strong>300MB</strong> needs to be adjusted<br />

such that the audio output is at the required<br />

<strong>MODEL</strong> 300GC<br />

24 VDC<br />

<strong>MODEL</strong> 300CK<br />

<strong>MODEL</strong> <strong>300MB</strong><br />

<strong>MODEL</strong> 300GC<br />

<strong>MODEL</strong> 300CK<br />

YEL<br />

BLU<br />

YEL<br />

BLU<br />

POWER<br />

LINES<br />

POWER LINES<br />

120 VAC 120 VAC<br />

LOCAL PWR. LOCAL PWR.<br />

290A2664-24C<br />

290A2664-19B


<strong>MODEL</strong> 300VCS-1<br />

GROUND<br />

10 1 GAIN 1716 10 8 1<br />

CNTR<br />

TB-2 TB-1<br />

120 VAC<br />

1 2 17 1 7 12 13 14 16<br />

TB-1 TB-2<br />

SIGNAL LINES SHIELDED<br />

TWISTED PAIR<br />

SIG. HI (YEL)<br />

COM. (BLU)<br />

GROUND<br />

Figure 3-6. Models <strong>300MB</strong> and 300VSC-1.<br />

<strong>300MB</strong> 300VSC-1/300SCW-1 300SSC<br />

TB1-8 PTT-NO TB2-13 PTT TB201-9 PTT<br />

TB1-10 PTT-COM TB2-7 GND TB201-8 COM<br />

TB1-16 SIG COM TB2-14 MIC COM TB201-8 COM<br />

TB1-17 MIC OUT TB2-12 MIC AUDIO IN TB201-7 AUDIO<br />

120/240 VAC<br />

120/240 VAC<br />

Table 3-2. 300MC Connections to 300VSC-1, 300SCW-1, or 300SSC.<br />

<strong>MODEL</strong> <strong>300MB</strong><br />

10 1 GAIN 17 1413 1<br />

CNTR<br />

TB-2 TB-1<br />

Figure 3-7. Model <strong>300MB</strong> with 25VRMS Connections.<br />

3-6<br />

YEL<br />

BLU<br />

SIGNAL LINES<br />

SHIELDED<br />

TWISTED PAIR<br />

<strong>MODEL</strong> <strong>300MB</strong><br />

<strong>MODEL</strong> 300GC<br />

<strong>MODEL</strong> 300CK<br />

POWER<br />

LINES<br />

120 VAC 120 VAC<br />

LOCAL PWR. LOCAL PWR.<br />

TB1-13<br />

TB1-14<br />

290A2664-20B<br />

SIGNAL -<br />

SIGNAL +<br />

TO ADDITIONAL SPEAKERS, 40 OHMS MAXIMUM LOAD<br />

290A2664-21B


GROUND<br />

120/240 VAC<br />

10 1 GAIN 1716 1<br />

CNTR<br />

TB-2 TB-1<br />

AUDIO INPUT<br />

<strong>MODEL</strong> <strong>300MB</strong><br />

CENTRAL AMPLIFIER<br />

remote mic audio input level (16mVrms MAX.) for<br />

the 300VSC-1. Failure to adjust this level will cause<br />

distortion and clipping in the system.<br />

C. <strong>300MB</strong> Driving a 25Vrms Speaker Line<br />

(see figure 3-7).<br />

In this installation the CommCenter is directly<br />

driving a speaker or speakers, the total power<br />

consumed not exceeding the drive capability of a<br />

CommCenter.<br />

D. <strong>300MB</strong> Interfacing with a Central Amplified<br />

System (see figure 3-8).<br />

In this installation the CommCenter is<br />

acting as an audio input to a Central Amplifier. Message<br />

playback can be added to an existing Centrally<br />

Amplified Paging System.<br />

3-12. STORAGE CHIP INSTALLATION.<br />

NOTE<br />

The CommCenter accepts messages stored<br />

on ICs and pluggable circuit boards. Both are<br />

referred to as message chips in this manual.<br />

The messages stored on pluggable circuit<br />

boards will operate on all Series B, Series C,<br />

and Series D Models.<br />

The Series D CommCenters use a different<br />

storage IC than the Series A, Series B, and<br />

Series C. These ICs cannot be interchanged between<br />

Series A, Series, B, and Series C models.<br />

Make sure to specify which series CommCenter<br />

you have before ordering any additional<br />

messages.<br />

It is necessary to perform the procedures in<br />

this section ONLY if it is required to change<br />

the priority of the storage chips or adding a<br />

different message to the unit is required.<br />

The <strong>300MB</strong> can accommodate up to six storage<br />

chips. The CommCenter should be shipped from the<br />

factory with the storage chips installed. Each storage<br />

SIGNAL LINES<br />

SHIELDED<br />

TWISTED PAIR<br />

Figure 3-8. Model <strong>300MB</strong> with Central Amplifier Connections.<br />

3-7<br />

TB1-16<br />

TB1-17<br />

chip is marked with the Model Number and other<br />

information.<br />

Failure to follow all safety precautions and<br />

instructions may result in property damage<br />

serious injury, or death to you or others.<br />

Do not perform any installation or maintenance<br />

on this system when power is on.<br />

This device is to be installed by a trained electrician<br />

who is thoroughly familiar with the<br />

National Electrical Code and will follow the<br />

NEC guidelines as well as local codes.<br />

NOTE<br />

SIGNAL COMMON<br />

MIC. OUT<br />

TO ADDITIONAL SPEAKERS, 40 OHMS MAXIMUM LOAD<br />

290A2664-22B<br />

The Storage Chips and the CommCenter’s<br />

circuitry can be destroyed or damaged by<br />

static discharge. Observe anti-static procedures<br />

when installing or servicing a<br />

CommCenter.<br />

Storage Chips should be installed starting at<br />

Priority Tone 1 and working downward. If, for example,<br />

only four messages are required, have PT1<br />

through PT4 sockets occupied and leave PT5 and PT6<br />

open.<br />

To remove a storage chip gently pry it out of its<br />

socket. To install the storage chips insert them into<br />

the desired sockets on the printed circuit board as<br />

shown in figure 1-3. Ensure that the notch on the<br />

edge of the new storage chip is facing in the same<br />

direction as the old one (next to the resistors at the<br />

edge of the board) and that all pins are properly inserted<br />

in the socket—not bent under.<br />

Test the CommCenter after any maintenance<br />

is performed.


4-1. GENERAL.<br />

The <strong>Federal</strong> <strong>Signal</strong> factory will service your<br />

equipment or provide assistance with technical problems<br />

that cannot be handled satisfactorily locally.<br />

Any units returned to <strong>Federal</strong> <strong>Signal</strong> for service,<br />

inspection, or repair, must be accompanied by a<br />

Return Material Authorization. The R.M.A. can be<br />

obtained from the local Distributor or Manufacturer’s<br />

Representative. At this time a brief explanation of<br />

the service requested or the nature of the malfunction<br />

should be provided.<br />

Address all communications and shipments to:<br />

Service Department<br />

Industrial Products<br />

<strong>Federal</strong> <strong>Signal</strong> Corporation<br />

2645 <strong>Federal</strong> <strong>Signal</strong> Drive<br />

University Park, IL 60466-3195<br />

708-534-3400<br />

SECTION IV<br />

SERVICE<br />

4-1<br />

NOTE:<br />

The CommCenter accepts messages stored on<br />

ICs and pluggable circuit boards. Both are referred<br />

to as message chips in this manual.<br />

The messages stored on pluggable circuit<br />

boards will operate on all Series B, Series C,<br />

and Series D Models.<br />

The Series D CommCenters use a different<br />

storage IC than the Series A, Series B, and<br />

Series C. These ICs cannot be interchanged between<br />

Series A, Series, B, and Series C models.<br />

Make sure to specify which series CommCenter<br />

you have before ordering any additional messages.<br />

4-2. REPLACEMENT PARTS.<br />

Description Part Number<br />

Mother Board 200D1148<br />

Fuse F1 250V,1/2 AMP GMC-1/2A 148A155<br />

Fuse F2 250V, 1 AMP GMC-1A 148A155-01<br />

TB1, 17 Position Terminal Block 140A332-17<br />

TB2, 10 Position Terminal Block 140A332-10


290A2921B<br />

NOTES:<br />

1. P.C. BOARD ASSEMBLY 200D1148.<br />

2. ALL RESISTORS ARE IN OHMS, 1/4W, 5% UNLESS OTHERWISE<br />

SPECIFIED.<br />

3. ALL CAPACITORS ARE IN MICROFARADS UNLESS OTHERWISE<br />

SPECIFIED.<br />

24K SMT<br />

200K<br />

CR6<br />

LED GRN<br />

1<br />

2<br />

R14<br />

2.2K,1/2<br />

1<br />

2<br />

24VA<br />

5V<br />

SMT<br />

2<br />

R102<br />

1<br />

18k<br />

SMT<br />

1<br />

2<br />

R106<br />

SMT<br />

18k<br />

1<br />

2<br />

SMT<br />

R108<br />

18k<br />

2 7<br />

6<br />

1 8<br />

2<br />

MC14532B<br />

D0<br />

D1<br />

IC10<br />

Q0<br />

VSS<br />

Q1<br />

Q2<br />

1<br />

10<br />

11<br />

9<br />

SMT<br />

R105<br />

18k<br />

TRANSF<br />

RLY DPDT<br />

CON3<br />

COM<br />

ULN2803A<br />

1N4006<br />

1<br />

2<br />

1<br />

1 2<br />

2<br />

0.1UF<br />

C12<br />

8<br />

ENOUT<br />

11<br />

CSCDEN<br />

R58<br />

2.2K,1/2<br />

C<strong>SD</strong>SIG<br />

10VRMS<br />

AUDCMN<br />

MICOUT<br />

13<br />

12<br />

17<br />

16<br />

15<br />

14<br />

DIF+<br />

DIF-<br />

CON17<br />

5V<br />

1<br />

2<br />

PT1<br />

1<br />

2<br />

MICOUT<br />

DIF+<br />

C<strong>SD</strong>SG<br />

10VRMS<br />

DIF-<br />

PT2<br />

PTTNO<br />

PTTCN<br />

PTTNC<br />

3<br />

TB1<br />

2<br />

1<br />

8<br />

7<br />

6<br />

5<br />

10<br />

9<br />

4<br />

PT4<br />

PT6<br />

PT5<br />

GND<br />

PT1<br />

PT2<br />

PT3<br />

PTT<br />

AUDIO<br />

24V<br />

GND<br />

PMNO<br />

PMCOM<br />

PTT<br />

12<br />

8<br />

9<br />

10<br />

11<br />

TB3<br />

13<br />

14<br />

15<br />

5V<br />

CON15<br />

PMCOM<br />

PMNC<br />

5V<br />

MICOUT<br />

I8<br />

GND<br />

9<br />

R90<br />

18k<br />

SMT<br />

PWRDN<br />

SMT<br />

2<br />

1<br />

7<br />

4<br />

5<br />

6<br />

3<br />

1<br />

PT6<br />

PT5<br />

PT2<br />

PT1<br />

PT3<br />

PT4<br />

2<br />

1<br />

R94<br />

18k<br />

2<br />

SMT<br />

1<br />

1<br />

IC1<br />

I2<br />

I1<br />

3<br />

2<br />

1<br />

I4<br />

I5<br />

I6<br />

I7<br />

7<br />

6<br />

4<br />

5<br />

I3<br />

2<br />

18k<br />

SMT<br />

1<br />

R91<br />

2<br />

18k<br />

R95<br />

SMT<br />

R92<br />

2<br />

SMT<br />

18k<br />

1<br />

2<br />

18k<br />

R96<br />

2.2K,1/2<br />

1<br />

2<br />

1<br />

CR1<br />

5.1V<br />

2<br />

2<br />

R2<br />

1N4006<br />

1<br />

+<br />

FUSE<br />

ACPIN<br />

ACCIN<br />

24VA<br />

9<br />

10<br />

CON10<br />

PWRDN<br />

24VIN<br />

TB2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

C<strong>SD</strong>EN<br />

C<strong>SD</strong>IN<br />

GND<br />

PMNC<br />

PMNO<br />

PMCN<br />

CSCDIN<br />

8<br />

2<br />

1<br />

F2<br />

PMCOM<br />

CR12<br />

K1<br />

SW DPDT<br />

F1<br />

FUSE<br />

JU2<br />

1<br />

2<br />

JUMPER<br />

1<br />

2<br />

2<br />

1<br />

2<br />

1<br />

JU1<br />

CON2<br />

240V 3<br />

4<br />

5<br />

J2<br />

CON2<br />

SW1<br />

120V<br />

T1<br />

2<br />

R16<br />

C9<br />

PRIOR 5<br />

CON3<br />

200K<br />

PRIOR 4<br />

CON3<br />

CON3<br />

PRIOR 3<br />

PRIOR 2<br />

PRIOR 1<br />

CON3<br />

11<br />

2.2K,1/2<br />

0.1UF<br />

C11<br />

2 1<br />

1<br />

3<br />

2<br />

4<br />

C15<br />

C16<br />

0.1UF<br />

0.1UF<br />

ILD-1<br />

IC4<br />

8<br />

6<br />

7<br />

5<br />

24VA<br />

R15<br />

O8<br />

10<br />

CR8<br />

CR9<br />

1N4006<br />

1N4006<br />

CR10<br />

2<br />

8<br />

R101<br />

18k<br />

2<br />

7<br />

1<br />

J9<br />

2<br />

3<br />

1<br />

R21<br />

1<br />

J10<br />

CON3<br />

2<br />

3<br />

13<br />

14<br />

12<br />

10<br />

11<br />

9<br />

5V<br />

2<br />

3<br />

5<br />

4<br />

6<br />

1<br />

IC5<br />

4584<br />

2<br />

C17<br />

0.1UF<br />

R20<br />

200K<br />

1<br />

2<br />

1<br />

J11<br />

2<br />

3<br />

1<br />

C6<br />

1<br />

PT3<br />

O2<br />

O1<br />

16<br />

17<br />

18<br />

O7<br />

O6<br />

O5<br />

O4<br />

12<br />

13<br />

15<br />

14<br />

O3<br />

2<br />

CR7<br />

10K<br />

R1<br />

1N4006<br />

2.2K,1/2<br />

2<br />

C7<br />

0.1UF<br />

C8<br />

0.1UF<br />

1<br />

1 2<br />

5V<br />

C1<br />

0.1UF<br />

0.1UF<br />

CR13<br />

R11<br />

1N4006<br />

2<br />

1<br />

24VA<br />

1<br />

2<br />

1<br />

2<br />

PT4<br />

J1<br />

3<br />

1<br />

2<br />

C2<br />

2.2UF<br />

1N4006<br />

PT5<br />

3<br />

2.2K,1/2<br />

0.1UF<br />

C5<br />

R10<br />

1<br />

2<br />

2 1<br />

1<br />

4<br />

0.1UF<br />

C10<br />

0.1UF<br />

24VA<br />

3<br />

4<br />

1<br />

2<br />

3<br />

14<br />

13<br />

11<br />

12<br />

9<br />

10<br />

8<br />

4<br />

6<br />

5<br />

7<br />

1<br />

2<br />

IC2<br />

1<br />

2<br />

3<br />

5V<br />

4584<br />

C<strong>SD</strong>EN<br />

R22<br />

200K<br />

1<br />

2 1<br />

200K<br />

R18<br />

2<br />

6<br />

IC25<br />

5<br />

ILD-1<br />

5<br />

6<br />

8<br />

7<br />

2<br />

1<br />

J4<br />

1<br />

2<br />

3<br />

NC<br />

NO<br />

NO<br />

NC<br />

5V<br />

3<br />

2<br />

1<br />

5<br />

4<br />

MC14068B<br />

IC11<br />

NC<br />

NO<br />

C29<br />

2.2UF<br />

I4<br />

I3<br />

I2<br />

I1<br />

GND<br />

NC<br />

NC<br />

+<br />

1<br />

2<br />

5<br />

6<br />

3<br />

4<br />

2<br />

7<br />

14<br />

12<br />

13<br />

10<br />

9<br />

11<br />

8<br />

I6<br />

OUT<br />

I7<br />

I8<br />

NC<br />

I5<br />

VDD<br />

200K<br />

R31<br />

1<br />

1 2<br />

MOM<br />

1<br />

CON3<br />

5V<br />

EOUT<br />

VDD<br />

D5<br />

D4<br />

D2<br />

D3<br />

GS<br />

EIN<br />

D7<br />

D6<br />

14<br />

15<br />

16<br />

12<br />

13<br />

3<br />

2<br />

1<br />

R27<br />

10K<br />

RPT<br />

CON3<br />

J14<br />

CON3<br />

J12<br />

2<br />

3<br />

5V<br />

3<br />

1<br />

RPT<br />

RPT<br />

MOM<br />

IC6<br />

NC<br />

0.1UF<br />

C24<br />

J5<br />

5V<br />

6<br />

Q1<br />

S1<br />

R1<br />

7<br />

12<br />

Q3<br />

R2<br />

S3<br />

R3<br />

GND<br />

IC8<br />

EN<br />

MC14043B<br />

15<br />

14<br />

11<br />

5<br />

S2 Q2<br />

+<br />

C18<br />

10UF<br />

1<br />

2<br />

2<br />

MC14043B<br />

Q0<br />

S0<br />

R0<br />

16<br />

5V<br />

3<br />

4<br />

200K<br />

1<br />

R17<br />

2<br />

NO<br />

1<br />

2<br />

200K<br />

NO<br />

NC<br />

R0<br />

5VR19<br />

2<br />

1<br />

Q1<br />

Q2<br />

S1<br />

R1<br />

S2<br />

Q3<br />

S3<br />

R3<br />

R2<br />

11<br />

12<br />

7<br />

5<br />

14<br />

15<br />

6<br />

EN GND<br />

5V<br />

Q0<br />

S0<br />

16<br />

5V<br />

3<br />

4<br />

CON3<br />

CON3<br />

J13<br />

9<br />

10<br />

1<br />

8<br />

2<br />

1<br />

2<br />

2<br />

J8<br />

1<br />

3<br />

1<br />

MOM<br />

2<br />

4<br />

NL27WZ00<br />

MOM<br />

RPT<br />

1<br />

SMT<br />

2<br />

8<br />

C107<br />

0.1µF, 50V<br />

CON3<br />

10<br />

8<br />

1<br />

9<br />

J7<br />

1<br />

3<br />

2<br />

2<br />

J6<br />

1<br />

2<br />

3<br />

MOM<br />

RPT<br />

5V<br />

2<br />

R120<br />

SMT<br />

200K<br />

R119<br />

1<br />

MOM<br />

RPT<br />

CON3<br />

PRIOR 6<br />

1<br />

2<br />

PT6<br />

1<br />

2<br />

PMNO<br />

CR11<br />

10K<br />

R3<br />

2<br />

24V<br />

C<strong>SD</strong>EN<br />

PMNC<br />

0.1UF<br />

R12<br />

24VA<br />

2.2K<br />

2<br />

1<br />

2<br />

R13<br />

2.2K<br />

C13<br />

0.1UF<br />

2<br />

1<br />

1 2<br />

C14<br />

STD OUT<br />

1 JU3<br />

JUMPER<br />

CWS IN<br />

1<br />

5V<br />

2<br />

8<br />

24VA<br />

1<br />

1000UF<br />

-<br />

1<br />

+<br />

C4<br />

2<br />

+<br />

5V<br />

IC24<br />

7<br />

8<br />

ILD-1<br />

R66<br />

18k<br />

SMT<br />

R67<br />

18k<br />

SMT<br />

1<br />

2<br />

J3<br />

1<br />

3<br />

2<br />

1<br />

2<br />

2<br />

R68<br />

18k<br />

SMT<br />

1<br />

R69<br />

18k<br />

SMT<br />

1<br />

+<br />

2<br />

2<br />

C76<br />

330UF<br />

CR5<br />

1N5253B<br />

FWB<br />

11<br />

CR2<br />

1<br />

R52<br />

220,1/2W<br />

Q3<br />

2N5296<br />

24V<br />

PRIORITY TONE 6<br />

APR9600<br />

1µF, 50V<br />

NL27WZ00<br />

11<br />

BUSY<br />

0.1µF, 50V<br />

SMT<br />

NL27WZ00<br />

NO<br />

NC<br />

1<br />

SMT<br />

200K<br />

2<br />

5V<br />

5<br />

7<br />

2<br />

4<br />

1<br />

2<br />

C98<br />

SMT<br />

U1A<br />

5V<br />

C91<br />

1<br />

8<br />

1<br />

12<br />

13<br />

BE<br />

VS<strong>SD</strong><br />

14<br />

VSSA<br />

SP+<br />

6<br />

OUT<br />

5V<br />

2<br />

1 R112<br />

1<br />

1<br />

C78<br />

100UF<br />

2<br />

+<br />

/ON<br />

5<br />

GND<br />

+VIN<br />

3<br />

5V<br />

R110<br />

24K SMT<br />

1<br />

2<br />

3<br />

M1<br />

M2<br />

4<br />

5<br />

6<br />

7<br />

8<br />

M4<br />

M5<br />

M6<br />

OscR<br />

9<br />

10<br />

M8<br />

M7<br />

M3<br />

CR4<br />

MR813<br />

2 1<br />

L1<br />

1.5MH<br />

18<br />

AGC<br />

220K<br />

SMT<br />

R116<br />

R114<br />

1µF, 50V<br />

18k<br />

SMT<br />

C99<br />

SMT<br />

1<br />

2<br />

16<br />

17<br />

SMT<br />

15<br />

MIC<br />

MIC REF<br />

SP-<br />

VCCA<br />

U1B<br />

3<br />

1<br />

2<br />

0.1µF, 50V<br />

1<br />

C92<br />

2<br />

1<br />

+<br />

22µF, 25V<br />

C96<br />

SMT<br />

1<br />

2<br />

4.7µF, 16V<br />

1+<br />

C95<br />

SMT<br />

2<br />

2<br />

C86<br />

0.005UF<br />

0.1µF, 50V<br />

27<br />

28<br />

26<br />

21<br />

22<br />

23<br />

24<br />

25<br />

19<br />

20<br />

IC22<br />

/RE<br />

VCCD<br />

CE<br />

STROBE<br />

Msel-2<br />

Msel-1<br />

ANA IN<br />

ANA OUT<br />

ExtClk<br />

C88<br />

1<br />

SMT<br />

1<br />

5v<br />

2<br />

1<br />

C73<br />

2<br />

+<br />

470UF<br />

1<br />

2<br />

C79<br />

2<br />

2<br />

0.1µF, 50V SMT<br />

5v<br />

1<br />

R109<br />

2<br />

18k<br />

SMT<br />

VCCA<br />

1<br />

+<br />

2<br />

C39<br />

22UF<br />

FEED<br />

IC20<br />

LM2575-5<br />

4<br />

5V<br />

OUT<br />

7<br />

8<br />

VSS<br />

MC14051B<br />

VEE<br />

2<br />

C45<br />

1<br />

1.0UF<br />

2<br />

1<br />

X6<br />

IC13<br />

X4<br />

4<br />

3<br />

X7<br />

XOUT<br />

5<br />

6<br />

INH<br />

X5<br />

10<br />

9<br />

C<br />

B<br />

15<br />

16<br />

X2<br />

VDD<br />

13<br />

14<br />

X0<br />

X1<br />

A<br />

11<br />

12<br />

X3<br />

2<br />

1<br />

2<br />

C46<br />

2<br />

18k<br />

SMT<br />

R107 1.0UF<br />

R104<br />

18k<br />

SMT<br />

COMPIN<br />

1<br />

2<br />

1<br />

R103<br />

18k<br />

SMT<br />

VCCA<br />

2<br />

1<br />

CSCDIN<br />

C54<br />

330UF<br />

1<br />

2<br />

PRIORITY TONE 2<br />

APR9600<br />

NL27WZ00<br />

C118<br />

0.1µF, 50V<br />

C120<br />

R133<br />

SMT<br />

220K<br />

R135<br />

R100<br />

C124<br />

NL27WZ00<br />

0.1µF, 50V<br />

100K<br />

ENOUT<br />

Q2<br />

2<br />

TIS92<br />

2<br />

+<br />

22<br />

1<br />

C30<br />

2<br />

24V<br />

1<br />

R26<br />

Q1<br />

TIS92<br />

CR3<br />

1N4006<br />

1<br />

2<br />

0.1µF, 50V<br />

0.1UF<br />

NL27WZ00<br />

SMT<br />

C130<br />

2<br />

1µF, 50V<br />

U5A<br />

5V<br />

1<br />

8<br />

4<br />

2<br />

1<br />

2<br />

SMT<br />

6<br />

5<br />

7<br />

1<br />

1<br />

C48<br />

2<br />

1<br />

SMT<br />

18k<br />

2<br />

C131<br />

1µF, 50V<br />

U5B<br />

3 1<br />

SMT<br />

18k<br />

C125<br />

1<br />

2 1<br />

APR9600<br />

PRIORITY TONE 4<br />

M3<br />

2<br />

24K SMT<br />

R131<br />

200K<br />

SMT<br />

4<br />

M5<br />

M6<br />

M7<br />

9<br />

6<br />

7<br />

8<br />

5<br />

M4<br />

BE<br />

11<br />

13<br />

12<br />

10<br />

SP+<br />

14<br />

M8<br />

OscR<br />

BUSY<br />

VS<strong>SD</strong><br />

VSSA<br />

5V<br />

R128<br />

M1<br />

M2<br />

1<br />

3<br />

2<br />

ExtClk<br />

25<br />

20<br />

23<br />

22<br />

21<br />

24<br />

16<br />

17<br />

18<br />

19<br />

15<br />

CE<br />

ANA OUT<br />

STROBE<br />

Msel-2<br />

Msel-1<br />

AGC<br />

MIC<br />

SP-<br />

MIC REF<br />

VCCA<br />

ANA IN<br />

SMT<br />

1<br />

1<br />

SMT<br />

26<br />

27<br />

28<br />

5v<br />

/RE<br />

VCCD<br />

IC16<br />

1<br />

SMT<br />

C105<br />

C112<br />

SMT<br />

22µF, 25V<br />

4.7µF, 16V<br />

0.1µF, 50V SMT<br />

19<br />

10<br />

AGC<br />

SP-<br />

VCCA<br />

MIC<br />

MIC REF<br />

U3A<br />

NL27WZ00<br />

1µF, 50V<br />

7<br />

C113<br />

1<br />

SMT<br />

2<br />

5<br />

BUSY<br />

BE<br />

VS<strong>SD</strong><br />

VSSA<br />

SP+<br />

12<br />

11<br />

14<br />

13<br />

5V<br />

APR9600<br />

6<br />

2<br />

1<br />

3<br />

1µF, 50V<br />

C114<br />

1<br />

2<br />

+1<br />

18k<br />

SMT<br />

2<br />

1<br />

2<br />

0.1µF, 50V<br />

17<br />

18<br />

15<br />

16<br />

U3B<br />

C108<br />

SMT<br />

+1<br />

2<br />

1<br />

2<br />

R124<br />

220K<br />

SMT<br />

R126<br />

/RE<br />

VCCD<br />

IC17<br />

Msel-2<br />

CE<br />

Msel-1<br />

ExtClk<br />

ANA IN<br />

ANA OUT<br />

STROBE<br />

M1<br />

M2<br />

M3<br />

M4<br />

M5<br />

M6<br />

OscR<br />

M7<br />

M8<br />

PRIORITY TONE 5<br />

1<br />

2<br />

7<br />

6<br />

5<br />

4<br />

3<br />

8<br />

9<br />

5v<br />

0.1µF, 50V<br />

28<br />

27<br />

22<br />

23<br />

24<br />

25<br />

26<br />

21<br />

20<br />

C103<br />

1<br />

SMT<br />

2<br />

2<br />

1<br />

C104<br />

M6<br />

R123<br />

0.1µF, 50V<br />

NL27WZ00<br />

U4A<br />

8<br />

SMT<br />

4<br />

2<br />

1<br />

6<br />

5<br />

7<br />

2 1<br />

SMT<br />

1µF, 50V<br />

C116<br />

24K SMT<br />

5V<br />

1<br />

C110<br />

2<br />

M7<br />

OscR<br />

M8<br />

BE<br />

BUSY<br />

VS<strong>SD</strong><br />

SP+<br />

VSSA<br />

8<br />

7<br />

11<br />

13<br />

12<br />

10<br />

9<br />

14<br />

R118<br />

SMT<br />

18k<br />

1<br />

2<br />

1<br />

5V<br />

2<br />

R121<br />

5V<br />

200K<br />

SMT<br />

M1<br />

M2<br />

M3<br />

M4<br />

M5<br />

2<br />

3<br />

1<br />

6<br />

5<br />

4<br />

PRIORITY TONE 1<br />

C133<br />

1µF, 50V<br />

0.1µF, 50V<br />

VCCA<br />

22µF, 25V<br />

2 1<br />

SMT<br />

C128<br />

+<br />

2<br />

2<br />

SMT<br />

1<br />

8<br />

4<br />

2<br />

1<br />

2<br />

C126<br />

SMT<br />

NL27WZ00<br />

5V<br />

U6A<br />

7<br />

1<br />

R130<br />

4.7µF, 16V<br />

2<br />

0.1µF, 50V SMT<br />

C122<br />

+1<br />

2<br />

SMT<br />

SMT<br />

2<br />

18k<br />

5v<br />

2<br />

1<br />

2<br />

1<br />

R132<br />

24K SMT<br />

SMT<br />

200K<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

R129<br />

5V<br />

1<br />

2<br />

3<br />

2<br />

0.1µF, 50V<br />

1<br />

1µF, 50V<br />

C132<br />

2<br />

6<br />

5<br />

NL27WZ00<br />

C127<br />

1<br />

2<br />

U6B<br />

3<br />

1<br />

C129<br />

22µF, 25V<br />

SMT<br />

1<br />

2 +<br />

2<br />

R136<br />

SMT<br />

18k<br />

ExtClk<br />

M3<br />

ANA OUT<br />

STROBE<br />

Msel-2<br />

Msel-1<br />

VCCA<br />

MIC REF<br />

ANA IN<br />

M5<br />

M6<br />

OscR<br />

M7<br />

M4<br />

BUSY<br />

BE<br />

VS<strong>SD</strong><br />

VSSA<br />

SP+<br />

M8<br />

APR9600<br />

25<br />

20<br />

21<br />

22<br />

23<br />

24<br />

CE<br />

15<br />

16<br />

17<br />

18<br />

19<br />

SMT<br />

SP-<br />

MIC<br />

AGC<br />

VCCD<br />

IC7<br />

5v<br />

M1<br />

M2<br />

27<br />

28<br />

26<br />

/RE<br />

0.1µF, 50V<br />

0.1µF, 50V SMT<br />

4.7µF, 16V<br />

SMT<br />

SMT<br />

1 2<br />

C121<br />

1+<br />

2<br />

R134<br />

1<br />

SMT<br />

220K<br />

C123<br />

2<br />

1<br />

C119<br />

5v<br />

CE<br />

R125<br />

C106<br />

220K<br />

SMT<br />

R127<br />

2<br />

U4B<br />

3<br />

1µF, 50V<br />

C117<br />

SMT<br />

18k<br />

2 1<br />

1<br />

15<br />

20<br />

18<br />

16<br />

17<br />

19<br />

21<br />

22<br />

ANA OUT<br />

STROBE<br />

MIC REF<br />

MIC<br />

AGC<br />

ANA IN<br />

SP-<br />

VCCA<br />

1<br />

1<br />

2<br />

C111<br />

SMT<br />

1<br />

0.1µF, 50V<br />

22µF, 25V<br />

+<br />

2 1<br />

2<br />

C115<br />

SMT<br />

4.7µF, 16V<br />

+1<br />

2<br />

2<br />

C109<br />

SMT<br />

0.1µF, 50V SMT<br />

0.1µF, 50V<br />

C102<br />

27<br />

26<br />

28<br />

23<br />

24<br />

25<br />

/RE<br />

ExtClk<br />

IC9<br />

VCCD<br />

Msel-2<br />

Msel-1<br />

5v<br />

1<br />

SMT<br />

5v<br />

2<br />

18k<br />

SMT<br />

R122<br />

1<br />

2<br />

23<br />

2<br />

16<br />

1<br />

VSS<br />

8<br />

X4<br />

X6<br />

X7<br />

XOUT<br />

2<br />

3<br />

4<br />

X5<br />

INH<br />

VEE<br />

5<br />

6<br />

7<br />

9<br />

C<br />

VDD<br />

13<br />

14<br />

X0<br />

X1<br />

X2<br />

15<br />

11<br />

12<br />

A<br />

X3<br />

B<br />

10<br />

1<br />

MC14051B<br />

VCCA<br />

C84<br />

0.1UF<br />

IC19<br />

1<br />

2<br />

2<br />

1<br />

C<strong>SD</strong>SG<br />

/RE<br />

VCCD<br />

CE<br />

STROBE<br />

Msel-2<br />

Msel-1<br />

AGC<br />

MIC REF<br />

ANA IN<br />

ANA OUT<br />

SP-<br />

VCCA<br />

BUSY<br />

5V<br />

NL27WZ00<br />

2<br />

4<br />

200K<br />

SMT<br />

5V<br />

C93<br />

8<br />

1<br />

2<br />

0.1µF, 50V<br />

SMT<br />

1<br />

1µF, 50V<br />

C100<br />

SMT<br />

7<br />

1<br />

2<br />

5<br />

VS<strong>SD</strong><br />

VSSA<br />

SP+<br />

NL27WZ00<br />

BE<br />

11<br />

12<br />

13<br />

14<br />

U2A<br />

MIC<br />

6<br />

APR9600<br />

24K SMT<br />

R113<br />

1<br />

5V<br />

5V<br />

2<br />

R111<br />

OUT<br />

1<br />

2<br />

1<br />

10K<br />

R39<br />

1<br />

2<br />

C71<br />

0.1<br />

PROIRITY TONE 3<br />

OscR<br />

M1<br />

1<br />

M2<br />

2<br />

3<br />

M4<br />

4<br />

M5<br />

5<br />

M6<br />

6<br />

7<br />

8<br />

M8<br />

9<br />

M7<br />

10<br />

M3<br />

IC12<br />

ExtClk<br />

C55<br />

0.01<br />

1<br />

2.2K<br />

R50<br />

1<br />

2<br />

2<br />

4.7µF, 16V<br />

22µF, 25V<br />

+<br />

SMT<br />

1<br />

2<br />

C101<br />

1µF, 50V<br />

C97<br />

SMT<br />

1<br />

18k<br />

2<br />

1<br />

2<br />

17<br />

18<br />

0.1µF, 50V<br />

1<br />

15<br />

C94<br />

SMT<br />

2<br />

16<br />

U2B<br />

1<br />

3<br />

1+<br />

2<br />

SMT<br />

220K<br />

R115<br />

C90<br />

SMT<br />

2<br />

R117<br />

1<br />

0.1µF, 50V SMT<br />

0.1µF, 50V<br />

SMT<br />

1<br />

5v<br />

27<br />

28<br />

26<br />

21<br />

22<br />

23<br />

24<br />

25<br />

19<br />

20<br />

C87<br />

2<br />

C89<br />

2<br />

1<br />

SSM2139<br />

3<br />

2<br />

8<br />

+<br />

-<br />

4<br />

1<br />

1<br />

IC15A<br />

C52<br />

1.0UF<br />

2<br />

5V<br />

R65<br />

18k<br />

SMT<br />

R32<br />

1K<br />

1<br />

2<br />

2<br />

R40<br />

10K<br />

2<br />

24V COMPIN<br />

2<br />

1<br />

1.0UF<br />

24V<br />

C47<br />

1K<br />

R59<br />

1 2<br />

0.1UF<br />

R45<br />

18k<br />

C51<br />

1.0UF<br />

11<br />

6<br />

INH<br />

VEE<br />

7<br />

VSS<br />

8<br />

MC14051B<br />

IC18<br />

B<br />

10<br />

A<br />

C<br />

9<br />

X4<br />

X6<br />

1<br />

2<br />

XOUT<br />

X7<br />

X5<br />

4<br />

5<br />

3<br />

X2<br />

15<br />

16<br />

VDD<br />

X3<br />

12<br />

X0<br />

13<br />

X1<br />

14<br />

2<br />

1<br />

2<br />

R80<br />

18k<br />

SMT<br />

1<br />

2<br />

1<br />

2<br />

1<br />

R70<br />

18k<br />

SMT<br />

VCCA<br />

VCCA<br />

C77<br />

0.1UF<br />

1<br />

2<br />

1.0UF<br />

2<br />

1<br />

2<br />

2<br />

SMT<br />

1<br />

2<br />

R62<br />

18k<br />

SMT<br />

SMT<br />

1<br />

1<br />

2<br />

VCCA<br />

1<br />

R60<br />

18k<br />

2<br />

1<br />

R77<br />

18k<br />

SMT<br />

R78<br />

18k<br />

SMT 12<br />

2<br />

VCCA<br />

1<br />

R71<br />

18k<br />

SMT<br />

VCCA<br />

18k<br />

SMT<br />

R72<br />

1 2<br />

1<br />

R81<br />

18k<br />

SMT<br />

2<br />

1<br />

2<br />

1<br />

R82<br />

18k<br />

SMT<br />

C53<br />

2.2UF<br />

+<br />

2<br />

2<br />

18k<br />

R73<br />

VCCA<br />

SMT<br />

2<br />

R74<br />

18k<br />

2<br />

VCCA<br />

1<br />

SMT<br />

R61<br />

SMT<br />

18k<br />

R63<br />

18k<br />

SMT<br />

1 2<br />

R49<br />

2<br />

680<br />

2<br />

VCCA<br />

1<br />

18k<br />

SMT<br />

R46<br />

10K<br />

1<br />

2<br />

1<br />

R47<br />

330<br />

VREF<br />

C38<br />

1<br />

1.0UF<br />

1<br />

R37<br />

9<br />

GND<br />

10<br />

GAIN<br />

10K<br />

1<br />

2 1<br />

IC14<br />

2<br />

2<br />

RIN1<br />

1<br />

2<br />

3<br />

4<br />

6<br />

7<br />

8<br />

5<br />

SA575<br />

+VIN<br />

-VIN<br />

VOUT<br />

CRT1<br />

SUM1<br />

COM1<br />

R48<br />

C50<br />

2<br />

1<br />

R44<br />

1<br />

1<br />

2<br />

2<br />

10K<br />

1<br />

C49<br />

VCCA<br />

VCCA<br />

R35<br />

10K<br />

1<br />

X5<br />

5<br />

INH<br />

VEE<br />

VSS<br />

7<br />

8<br />

6<br />

12<br />

X3<br />

9<br />

10<br />

C<br />

B<br />

A<br />

11<br />

VCCA<br />

IC23<br />

MC14051B<br />

R99<br />

18k<br />

SMT<br />

23<br />

1<br />

X6<br />

XOUT<br />

2<br />

3<br />

X7<br />

4<br />

X4<br />

16<br />

14<br />

15<br />

13<br />

X1<br />

X2<br />

X0<br />

VDD<br />

2<br />

C85<br />

0.1UF<br />

1<br />

2<br />

1<br />

R97<br />

18k<br />

SMT<br />

1<br />

2<br />

18k<br />

R89<br />

SMT<br />

1<br />

VCCA<br />

R93<br />

18k<br />

SMT<br />

VCCA<br />

1<br />

2<br />

18k<br />

R87<br />

SMT<br />

18k<br />

SMT<br />

R88<br />

SMT<br />

18k<br />

2<br />

VCCA<br />

R84<br />

10VRMS<br />

2<br />

1<br />

2<br />

1<br />

R5<br />

1<br />

10K<br />

2<br />

R28<br />

120,2W<br />

MICOUT<br />

R4<br />

100<br />

RLY DPDT<br />

DIF+<br />

DIF-<br />

MUTE<br />

TDA2616<br />

Insert<br />

R36<br />

2<br />

1<br />

C69<br />

STD IN<br />

CWS CUT<br />

1<br />

2<br />

18k<br />

R79<br />

SMT<br />

1<br />

R83<br />

18k<br />

SMT<br />

R7<br />

VCCA<br />

2<br />

18k<br />

R75<br />

SMT<br />

VCCA<br />

R76<br />

18k<br />

22UF<br />

2.2K<br />

SMT<br />

K2<br />

0<br />

1 2<br />

C3<br />

0.1UF<br />

1<br />

1<br />

2<br />

1<br />

2<br />

C74<br />

22UF<br />

2<br />

1<br />

2<br />

COM2<br />

12<br />

11<br />

GAIN<br />

SUM2<br />

R6<br />

50K<br />

2<br />

2<br />

1<br />

2<br />

R8<br />

2.2K<br />

17<br />

18<br />

19<br />

20<br />

2<br />

VOUT<br />

-VIN<br />

+VIN<br />

VCC<br />

13<br />

14<br />

15<br />

SUM2<br />

CRT2<br />

RIN2<br />

16<br />

R33<br />

27K<br />

1<br />

2<br />

1<br />

C37<br />

1.0UF<br />

2<br />

1<br />

2<br />

C75<br />

1<br />

22UF<br />

C72<br />

2<br />

1<br />

2<br />

R51<br />

8.2<br />

0.01<br />

2<br />

R9<br />

10K<br />

1<br />

2<br />

1<br />

+ C68<br />

100UF<br />

2<br />

1<br />

C70<br />

22UF<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

1<br />

C80<br />

0.005UF<br />

C83<br />

0.1UF<br />

C32<br />

1000UF<br />

1<br />

2<br />

+<br />

24V<br />

GND<br />

OUT1<br />

-Vcc<br />

OUT2<br />

INV2<br />

-IN2<br />

+Vcc<br />

IC21<br />

0.01<br />

1<br />

R34<br />

10K<br />

1<br />

C31<br />

22UF<br />

2<br />

+<br />

C82<br />

0.1<br />

1<br />

1<br />

2<br />

1<br />

2<br />

C81<br />

2<br />

-IN1<br />

4-2<br />

Figure 4-1. Model <strong>300MB</strong> Series D Schematic Diagram.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!