Universal-NEUROTON 926 - Gbo Medizintechnik
Universal-NEUROTON 926 - Gbo Medizintechnik
Universal-NEUROTON 926 - Gbo Medizintechnik
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Universal</strong>-<strong>NEUROTON</strong> ® <strong>926</strong><br />
Treatment time<br />
Intensity<br />
Power supply<br />
Power consumption<br />
Class of protection<br />
Degree of protection<br />
Class of equipment<br />
Dimensions<br />
Weight<br />
Warranty period<br />
max. 40minutes<br />
see table below<br />
110/120/230/240V, 50/60Hz<br />
max. 230 VA<br />
I (IEC601/VDE 0750)<br />
BF (IEC 601/VDE 0750)<br />
IIa acc to MDD<br />
410 X 150 x 480 mm (WxHxD)<br />
max 17 kg<br />
24 months<br />
Subject to technical changes<br />
without prior notice.<br />
The high-end device<br />
for high-performance<br />
Stimulation-Current<br />
diagnosis and therapy<br />
The <strong>Universal</strong>-<br />
<strong>NEUROTON</strong> ® <strong>926</strong> is a<br />
universal Stimulation-<br />
Current device for<br />
electrodiagnosis and electrotherapy<br />
and for diverse<br />
research applications. With<br />
its extensive application<br />
possibilities the <strong>Universal</strong>-<br />
<strong>NEUROTON</strong> ® <strong>926</strong> is<br />
predestined for use as a<br />
high-performance and<br />
convenient device in<br />
physiotherapy sections of<br />
hospitals, for electrodiagnosis<br />
examination units<br />
and for neurological<br />
consultants.<br />
<strong>Universal</strong>-<strong>NEUROTON</strong> ®<br />
<strong>926</strong> is particularly ideal for<br />
the following diagnosis<br />
applications:<br />
• Qualitative and<br />
quantitative<br />
measurement of faradic<br />
excitability<br />
• Determination of<br />
rheobase, chronaxy and<br />
accommodation<br />
• MF-test in accordance<br />
with Dr. Lange<br />
• Recording of I/T curves<br />
(capable of numerical and<br />
graphic presentation in the<br />
display)<br />
gbo <strong>Medizintechnik</strong> AG<br />
Kleiststrasse 6<br />
D-64668 Rimbach<br />
Germany<br />
• Comprehensive noninvasive<br />
electrodiagnosis of<br />
peripheral paralyses<br />
• Neuraldiagnostic<br />
examinations with<br />
galvanopalpation<br />
• Pelvic floor stimulation<br />
• Treatment of urinary<br />
and fecal incontinence<br />
<strong>Universal</strong>-<strong>NEUROTON</strong> ®<br />
<strong>926</strong> offers the following as<br />
options:<br />
• Integrated suction<br />
application module with<br />
suction massage<br />
• Integrated module for<br />
ultrasonic wave therapy<br />
with continuous or<br />
impulse sound waves<br />
and for the combination<br />
of electrotherapy and<br />
ultrasound therapy<br />
Tel.: +49(0)6253/808-0<br />
Fax: +49(0)6253/808-245<br />
e-mail: Info@gbo-med.de<br />
internet: www.gbo-med.de
Table of currents (1)<br />
Current Grafics Pulse<br />
duration T in<br />
ms<br />
Galvanic current<br />
Ultrastimulation<br />
current<br />
Faradic current<br />
Strong muscle<br />
stimulation<br />
Micro-stimulus<br />
current<br />
<strong>Universal</strong> therapy<br />
Diphasé fixe<br />
Courtes périodes<br />
Middle frequency<br />
current 8 kHz<br />
MF I / surged<br />
MF II / sinus surged<br />
MF III / 50 Hz<br />
MF IV / 3 - 10 Hz<br />
MF V / 10 - 30 Hz<br />
MF VI /<br />
30 - 60 Hz<br />
MF VII /<br />
100 - 200 Hz<br />
High voltage<br />
currents<br />
HV I / 50 Hz<br />
HV II / 3 -10 Hz<br />
HV III /<br />
10 - 30 Hz<br />
HV IV /<br />
30 - 60 Hz<br />
HV V /<br />
100 - 200 Hz<br />
Tens currents<br />
Tens I / 100 Hz<br />
Tens II /<br />
3 - 10 Hz<br />
Pause<br />
duration<br />
R in ms<br />
D.C.<br />
portion<br />
in %<br />
Frequency<br />
in Hz<br />
Maximum<br />
output<br />
voltage by<br />
CV in V peak<br />
gbo <strong>Medizintechnik</strong> AG<br />
Kleiststrasse 6<br />
D-64668 Rimbach<br />
Germany<br />
Max. output<br />
current by<br />
CC in mA peak<br />
- - 100 0 70 701)<br />
2.0 5.0 28.6 143 70 70<br />
1.0 - 3.0 17.0 - 19.0 2.6 50 70 70<br />
0.02 - 2000 0.5 ms - 10 s 0 0.1 - 2000 70 70<br />
0.02 - 40 0.5 ms - 10 s 0 20 - 2000 5 5<br />
0.02 - 2000 0.5 ms - 10 s 0.1 - 2000 70 70<br />
- - 63 100 70 70<br />
- - 47.25 50 / 100 70 70<br />
- - 0 - 140 140<br />
- - 0 - 140 140<br />
4.0 0.5 ms - 10 s 0 0.1 – 222.2 140 140<br />
50 - 167 50 - 167 0 3.0 - 10 140 140<br />
16.5 – 50.0 16.5 – 50. 0 0 10 - 30 140 140<br />
8.3 – 16. 0 8.3 – 16.0 0 30 - 60 140 140<br />
4.0 1.0 – 6.0 0 100 - 200 140 140<br />
4.5 0.5 ms - 10 s 0 0.1 - 200 200 200<br />
4.5 95.5 – 325.5 0 3.0 - 10 200 200<br />
4.5 28.5 – 95.5 0 10 - 30 200 200<br />
4.5 12.5 – 28.5 0 30 - 60 200 200<br />
4.5 0.5 – 5.5 0 100 - 200 200 200<br />
0.2 0.5 ms – 10 s 0 0.1 -1428.6 100 100<br />
0.2 100.0 -<br />
330.0<br />
0 3.0 - 10 100 100<br />
Tel.: +49(0)6253/808-0<br />
Fax: +49(0)6253/808-245<br />
e-mail: Info@gbo-med.de<br />
internet: www.gbo-med.de
Table of currents (2)<br />
Tens III /<br />
10 - 30 Hz<br />
Tens IV /<br />
30 - 60 Hz<br />
Current Grafic Pulse<br />
duration T in<br />
ms<br />
Tens V /<br />
100 - 200 Hz<br />
Tens Burst<br />
currents<br />
Tens Burst I /<br />
50 Hz<br />
Tens Burst II /<br />
3 - 10 Hz<br />
Tens Burst III /<br />
10 - 30 Hz<br />
Tens Burst IV /<br />
30 - 60 Hz<br />
Tens Burst V /<br />
100 - 200 Hz<br />
Pause<br />
duration<br />
R in ms<br />
D.C.<br />
portion<br />
in %<br />
Frequency<br />
in Hz<br />
Maximum<br />
output<br />
voltage by<br />
CV in Vpeak gbo <strong>Medizintechnik</strong> AG<br />
Kleiststrasse 6<br />
D-64668 Rimbach<br />
Germany<br />
Max. output<br />
current by<br />
CC in mA peak<br />
0.2 33.0 - 100.0 0 10 - 30 100 100<br />
0.2 17.0 - 33.0 0 30 - 60 100 100<br />
0.2 5.0 - 10.0 0 100 - 200 100 100<br />
2.0 0.5 ms – 10 s 0 0.1 - 400 100 100<br />
2.0 98.0 - 328.0 0 3.0 - 10 100 100<br />
2.0 31.0 – 98.0 0 10 - 30 100 100<br />
2.0 15.0 – 31.0 0 30 - 60 100 100<br />
2.0 3.0 – 8.0 0 100 - 200 100 100<br />
Special currents<br />
Monophasé fixe MF 10 10 31.5 50 70 70<br />
Longues périodes LP - - 46 50 / 100 70 70<br />
Impulse<br />
galvanization<br />
IG 30<br />
Impulse<br />
galvanization<br />
IG 50 / surged<br />
Frequency<br />
modulation<br />
FM / 7 - 14 Hz<br />
Incontinence<br />
30.0 50.0 18 12.5 70 70<br />
50.0 70.0 0.3 8.3 70 70<br />
0.5 70.9 – 142.4 0.4 7 - 14 70 70<br />
0.02 - 100 0.5 - 100 0 10 - 90 70 70<br />
Diagnostic currents<br />
Rheobase 1000 2000 33 0.33 35<br />
Chronaxy 0.02 - 2000 2000 - 0.2 – 0.5 70<br />
Accommodability 1000 2000 16.5 0.33 70<br />
I/T Curve Recording 1000 2000 max. 33 0.33 70<br />
Faradic current 1 19 2.6 0.33 70<br />
<strong>Universal</strong> Diagnosis 0.02 - 2000 0.5 ms – 10 s max.<br />
4.5<br />
0.1 - 2000 70<br />
Middle Frequency<br />
Test<br />
300 - 0 - 70<br />
1) In case of using the suction electrodes the maximum current is reduced to 20 mA.<br />
Tel.: +49(0)6253/808-0<br />
Fax: +49(0)6253/808-245<br />
e-mail: Info@gbo-med.de<br />
internet: www.gbo-med.de