Technical Information<br />

<strong>TI</strong> <strong>RecRead</strong>_e_12.07<br />

888<br />

Instruktor<br />

900<br />

Veritas<br />

1000<br />

4000<br />

Veritas<br />

5000<br />

Fuel flow<br />

Master<br />

6000<br />

Swissline<br />

FS<br />

Board<br />

Computer<br />

+<br />

Totalizer<br />

Data<br />

Logger<br />

and<br />

Software<br />

SOFTWARE<br />

<strong>RecRead</strong><br />

Record and Visualise with your<br />

computer your engine or vehicle<br />

testing<br />

<strong>RecRead</strong> Software has been developed<br />

to be a simple to use software. You will<br />

be able to visualise and record live your<br />

fuel consumption related to the vehicle<br />

speed and distance.<br />

This Windows based software can be<br />

installed on any computer or laptop.<br />

A USB serial input connected to the<br />

DL4044 Light gives you the link to the<br />

software and the configuration menu.<br />

Application<br />

• Specifically made for testing<br />

application for the automotive<br />

industry.<br />

SYSTEMS AG<br />

Automotive Information and Control <strong>Systems</strong><br />

Switzerland


Features<br />

Software description<br />

Instantaneous fuel<br />

consumption<br />

Resetable totalizer for<br />

fuel consumed<br />

Temporarily stops<br />

the fuel and<br />

distance totalizer<br />

Average fuel<br />

consumed<br />

(constantly updated)<br />

Overall fuel totalizer<br />

Software configuration<br />

Connection<br />

A complete measuring system<br />

consists of :<br />

• Data Logger DL4044 Light +<br />

cables<br />

• <strong>RecRead</strong> Software<br />

• PC or Laptop<br />

System and Units setting<br />

Green live line for test<br />

running proof<br />

Configure your system language.<br />

FR for French (metric system)<br />

DE for German (metric system)<br />

GB for English (metric system)<br />

US for English (US system MPG)<br />

IMPORTANT: after changing unit and / or language it is<br />

necessary to re-start the program.<br />

Configure as per your best computer settings the serial<br />

communication port.<br />

Options:<br />

Serial Port: select between 1 to 12 the connected one<br />

Baud rate: select between 300 to 19200<br />

Select your data bit, stop bit or Parity further settings.<br />

2<br />

<strong>AIC</strong> <strong>RecRead</strong><br />

Software<br />

Scope of supply of <strong>RecRead</strong> Software<br />

Instantaneous<br />

speed<br />

Resetable totalizer<br />

for distance driven<br />

Reset to zero the both fuel<br />

and distance totalizers<br />

Average speed<br />

(constantly updated)<br />

Overall fuel totalizer


Software configuration (continuing)<br />

How to calibrate your distance factor ?<br />

Data export<br />

Sensor administration<br />

Configure as per your <strong>AIC</strong> fuel flow meter the pulse rate<br />

Exp. <strong>AIC</strong> 4008 VERITAS will be 800 ppl<br />

Configure as per your vehicle odometer specification or<br />

calibrate yourself the exact distance driven. (see hereafter<br />

how to do this specific calibration)<br />

Transfer the factors settings to the Data Logger i.e.<br />

DL4044 Light.<br />

Eventually reset completely the memory of the fuel and/or<br />

the distance totalizer.<br />

Choose your drive and directory where the CSV data shall<br />

be stored.<br />

Furthermore, choose your posting time period, between 1<br />

and 60 sec.<br />

Your data is ready to be read and stored into your<br />

computer.<br />

First find a street or highway section where the distance between two points is well known:<br />

i.e. 10,0 km<br />

Set a figure into the distance factor field: i.e. 10000 ppk (pulses per kilometre).<br />

Reset the distance totalizer to zero.<br />

Drive your 10,0 km point to point exactly. Important try to drive this distance to a reasonable speed and constantly (i.e. 50 km/h).<br />

Stop and read the distance driven: i.e. 9,876 km, and correct the initial factor to 10124 ppk and restart your test distance to the same speed.<br />

After testing a second time you shall be knowing now what the exact ppk your odometer is giving.<br />

Notice also that if car or truck tires are worn after 20’000 km or if you change tires, start the distance calibration procedure to compensate the wheel diameter change.<br />

Visualisation of results<br />

The basic documents are created under a .csv (Comma Separated Value) and can be opened with any<br />

spreadsheet software. By using the designated software you can create and display as per your demand the<br />

document you like to have.<br />

MS Excel Spreadsheet and drawing sample<br />

Test realised on August 2007—Car BMW 330 d<br />

3


PC minimal configuration<br />

• Windows 98, 2…, XP<br />

• Intel Pentium 1GHz<br />

• 256 Mo RAM<br />

• No specific graphic card required<br />

• 4 Mb available for Software installation<br />

• CD / DVD drive<br />

• 1 free USB Serial input (USB 1.0 or USB 2.0)<br />

Remark:<br />

storing data on your computer for a long test run many days, can require a large CSV file (several Mb).<br />

Allow on your PC a minimum of 10 Mb available room for data storage.<br />

Ordering structure<br />

Model Type<br />

Data logging Software<br />

<strong>RecRead</strong> software<br />

Accessories<br />

DL4044 Light<br />

Extension USB cable<br />

Power supply adapter<br />

RS232 - USB cable<br />

Document ref. <strong>TI</strong> <strong>RecRead</strong>_e_12.07<br />

Designation<br />

Software for live data recording of your tests in your vehicle or<br />

at your laboratory.<br />

Data Logger box for real time fuel consumption and distance -<br />

speed.<br />

Includes:<br />

- Power supply cable (2.5m)<br />

- RS232 - USB connection cable (0.3m) + Software<br />

1 m extension connection<br />

12 VDC, with cigarette lighter car connector<br />

Vout : 15 - 24 VDC<br />

Pmax = 120 W<br />

RS232 - USB adapting cable + Software<br />

4<br />

Order code<br />

SRS.00<br />

S4044L.00<br />

5550.01<br />

1421.0<br />

5550.00<br />

<strong>AIC</strong> SYSTEMS Ltd.<br />

P.O. Box 341<br />

Ringstrasse 9,<br />

CH - 4123 Allschwil<br />

Switzerland<br />

T +41 61 481 84 39<br />

F +41 61 481 84 40<br />

M +41 79 212 28 31<br />

www.flowmeter-aic.com<br />

aic@bluewin.ch<br />

SYSTEMS AG<br />

Automotive Information and Control <strong>Systems</strong><br />

Switzerland