<strong>YCW</strong> <strong>750</strong> <strong>OG</strong> <strong>Curtain</strong> <strong>Wall</strong> <strong>System</strong><br />

STEP 3<br />

FABRICATE VERTICAL MULLIONS<br />

FRAME FABRICATION<br />

-Mullion hole locations for shear blocks, shear clips, and “J” anchors are shown below.<br />

-Drill 0.213” dia. (#3 drill bit) holes for shear block/clip attachment at the locations indicated.<br />

Drill 0.281” dia. (#9/32 drill bit) holes for “J” anchor attachment at the sill.<br />

See Detail 2.<br />

Note: Hole locations for shear clips, E1-1213 & E1-1214, are not the same as for<br />

shear blocks and “J” anchors.<br />

Detail 2<br />

Effective Date: July 15, 2004 Page-9