Optionally, you can design the<br />

connecting reinforcement for<br />

rising concrete walls.<br />

Under permanent load, no gaping<br />

joint must occur and under<br />

the total load, gaping of the<br />

foundation joint is only allowed<br />

up to the centre of gravity.<br />

The permissible soil pressure<br />

refers to a partial surface A'<br />

with the load application point<br />

in its center.<br />

The bending design is performed<br />

in accordance with the<br />

kh-method. The design moment<br />

for the bending design is calculated<br />

in the wall axis with masonry<br />

walls and at the face with<br />

concrete walls.<br />

The shear reinforcement is<br />

located at a distance equal to<br />

h/2 from the left and right wall<br />

edge. Outputs are:<br />

the shear force at the design<br />

section, Tau0,<br />

Tau (including the shear<br />

zone-specific reduction) and<br />

the shear reinforcement resulting<br />

from Tau.<br />

According to DIN 1045, no<br />

shear reinforcement is required<br />

if the following applies:<br />

max Tau0 < k1 . Tau0ll