www.dell.com | support.dell.com<br />
redundancy force-failover rpm<br />
This command causes an RPM failover to fail over to the Stack Standby RPM rather than the Chassis<br />
Standby RPM.<br />
Syntax redundancy force-failover rpm<br />
Command Mode EXEC Privilege<br />
Command<br />
History<br />
Example <strong>Force10</strong># redundancy force-failover rpm<br />
System configuration has been modified. Save? [yes/no]: yes<br />
Oct 28 14:34:59.289: %STKUNIT0-M-RPM0-P:CP %FILEMGR-5-FILESAVED: Copied<br />
running-config to startup-config in flash by default<br />
Synchronizing data to peer RPM<br />
!!!!!!<br />
Proceed with RPM hot failover [confirm yes/no]:yes<br />
reset stack-unit<br />
ex Reset a stack-unit within the Virtual Stack.<br />
Syntax reset stack-unit number {hard}<br />
Parameters<br />
Defaults<br />
Command Mode EXEC<br />
Command<br />
History<br />
Example <strong>Force10</strong>#reset stack-unit 1 hard<br />
Proceed with reset? [yes/no]: yes<br />
6 | VirtualScale Getting Started <strong>Commands</strong><br />
Version 8.4.4.0 Introduce support for VirtualScale<br />
number Enter the Stack ID number.<br />
Range 0-1<br />
hard Enter the keyword hard to reset the unit.<br />
Version 8.4.4.0 Introduced