PRODUCT INFORMATION<br />
GRASSO SCREW COMPRESSORS<br />
<strong>Types</strong> C ... <strong>XF</strong><br />
COMPRESSOR DESIGN CRITERIA<br />
(0) at 2940 min-1 (50 Hz-mains; for 60 Hz multiply by 1.2<br />
The values of the swept volume flow refer to the standard design of the compressor,<br />
when the frame size and the swept volume have the identical letter (see data sheet<br />
model designation )Chapter 3, page 12<br />
(1) ZM numbers of lobes, male rotor<br />
ZF<br />
numbers of lobes, female rotor<br />
(2) PS parallel slide system, PS 0 : infinitely variable Vi adjustment<br />
PS 2 : 2-stage Vi- adjustment<br />
TS tandem slide system TS 0 : infinitely variable Vi adjustment<br />
ES single slide ES 0 : infinitely variable Vi adjustment<br />
(3) A standard configuration with solenoid valve blocks for capacity and Vi-adjustment of the<br />
compressor;<br />
B<br />
C<br />
D<br />
E<br />
special design without solenoid valve blocks,<br />
solenoid valve blocks, suction filter *) , check valve on the suction side *) , oil pump on the<br />
compressor *) ;<br />
Solenoid valve blocks, suction filter *) , check valves (suction and pressure side) *) , oil<br />
pump on compressor *) *) **)<br />
, overflow valve<br />
flanged solenoid valves for Vi-adjustment<br />
(4) W antifriction bearings<br />
G<br />
sleeve bearings<br />
(5) O compressor operation with flanged oil pump for capacity control<br />
M<br />
N<br />
compressor operation with external oil pump<br />
compressor operates without oil pump<br />
(6) F flange motor<br />
E<br />
motor and compressor installed separately<br />
(7) at 6000 min -1<br />
with *) labeled components are optional. For <strong>compressors</strong> without oil pump on the compressor, an external oil<br />
pump is needed.<br />
**) The overflow valve operates based on the differential pressure. Overflow valves are available for various pressure<br />
differentials. The selection is made independent of the suction pressure and permitted discharge pressure of<br />
each operation.<br />
18 _101011_pi_sc_gbr_2_.doc <strong>GEA</strong> Refrigeration Germany GmbH<br />
23.03.2012