<strong>High</strong> <strong>Solid</strong> <strong>Cream</strong>-<strong>to</strong>-<strong>Powder</strong> <strong>Foundation</strong><br />

<strong>Cream</strong>y <strong>application</strong> <strong>with</strong> a velvet finish<br />

CC 1079-10<br />

%<br />

A Phenyl Trimethicone 14.00<br />

TEGOSOFT® OP 14.60<br />

Ethylhexyl Palmitate<br />

TEGOSOFT® CO 5.00<br />

Cetyl Ethylhexanoate<br />

Carnauba Wax 4.70<br />

ABIL® Wax 2434 4.00<br />

Stearoxy Dimethicone<br />

PVP/Eicosene Copolymer 1.00<br />

TEGOSOFT® SH 2.85<br />

Stearyl Heptanoate<br />

B Covabead LH 85 6.00<br />

Polymethylmethacrylates,<br />

Aerosil 200 0.25<br />

Silica, Degussa<br />

Zinc Oxide 7.00<br />

Talc Covasil 4.05 9.50<br />

Talc; Dimethicone; Trimethylsiloxysilicate,<br />

Polytrap Q5-6603 2.00<br />

Acrylates Copolymer,<br />

TEGOLON® 12-10 2.00<br />

Nylon-12<br />

Aluminum Starch Octenylsuccinate 9.50<br />

Iron Oxides 3.10<br />

Titanium Dioxide (and) Dimethicone 14.50<br />

Preparation:<br />

1. Heat phase A <strong>to</strong> 80 – 82 °C under stirring.<br />

2. Add Polymethyl Methacrylate, stir and homogenize for at least 10 minutes.<br />

3. Add the remaining ingredients one after one under stirring.<br />

4. Homogenize for 30 minutes at 80 – 82 °C.<br />

5. Pour in<strong>to</strong> packaging.<br />

Evonik Goldschmidt GmbH Goldschmidtstrasse 100 45127 ESSEN, GERMANY<br />

P.O. Box 45116 Essen TELEFON +49 201 173-2854 TELEFAX +49 201 173-1828<br />

personal-care@evonik.com www.evonik.com/personal-care<br />

This information and all further technical advice are based on Evonik Goldschmidt GmbH's present<br />

knowledge and experience.However, Evonik Goldschmidt GmbH assumes no liability for providing<br />

such information and advice including the extent <strong>to</strong> which such information and advice may relate <strong>to</strong> existing third party intellectual property rights, especially patent rights. In particular,<br />

Evonik Goldschmidt GmbH disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A<br />

PARTICULAR PURPOSE OR MERCHANTABILITY. EVONIK GOLDSCHMIDT GMBH SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES<br />

(INCLUDING LOSS OF PROFITS) OF ANY KIND. Evonik Goldschmidt GmbH reserves the right <strong>to</strong> make any changes according <strong>to</strong> technological progress or further developments. It is the<br />

cus<strong>to</strong>mer's responsibility and obligation <strong>to</strong> carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by<br />

qualified experts. It is the sole responsibility of the cus<strong>to</strong>mer <strong>to</strong> carry out and arrange for any such testing. Reference <strong>to</strong> trade names used by other companies is neither a recommendation,<br />

nor an endorsement of any product and does not imply that similar products could not be used. (Status: February, 2008)<br />

Page 1


<strong>High</strong> <strong>Solid</strong> <strong>Cream</strong>-<strong>to</strong>-<strong>Powder</strong> <strong>Foundation</strong><br />

<strong>Cream</strong>y <strong>application</strong> <strong>with</strong> a velvet finish<br />

CC 1079-10<br />

Remarks:<br />

Mineral Oil free<br />

Evonik Goldschmidt GmbH Goldschmidtstrasse 100 45127 ESSEN, GERMANY<br />

P.O. Box 45116 Essen TELEFON +49 201 173-2854 TELEFAX +49 201 173-1828<br />

personal-care@evonik.com www.evonik.com/personal-care<br />

This information and all further technical advice are based on Evonik Goldschmidt GmbH's present<br />

knowledge and experience.However, Evonik Goldschmidt GmbH assumes no liability for providing<br />

such information and advice including the extent <strong>to</strong> which such information and advice may relate <strong>to</strong> existing third party intellectual property rights, especially patent rights. In particular,<br />

Evonik Goldschmidt GmbH disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A<br />

PARTICULAR PURPOSE OR MERCHANTABILITY. EVONIK GOLDSCHMIDT GMBH SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES<br />

(INCLUDING LOSS OF PROFITS) OF ANY KIND. Evonik Goldschmidt GmbH reserves the right <strong>to</strong> make any changes according <strong>to</strong> technological progress or further developments. It is the<br />

cus<strong>to</strong>mer's responsibility and obligation <strong>to</strong> carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by<br />

qualified experts. It is the sole responsibility of the cus<strong>to</strong>mer <strong>to</strong> carry out and arrange for any such testing. Reference <strong>to</strong> trade names used by other companies is neither a recommendation,<br />

nor an endorsement of any product and does not imply that similar products could not be used. (Status: February, 2008)<br />