Intera<strong>to</strong>m Safety Analysis of <strong>HTR</strong>-<strong>Module</strong> (2)<br />
• <strong>Application</strong> of so-called Trumpet Curve for coated particle failure fraction<br />
1.0E-03<br />
Co oated particle<br />
failure frac ction<br />
1.0E-04<br />
Fresh fuel element<br />
Fuel element (50% target burnup)<br />
Fuel element (100% target burnup)<br />
1.0E-05<br />
1000 1100 1200 1300 1400 1500 1600<br />
Fuel temperature [°C]<br />
A. Xhonneux Technical Meeting on Re-evaluation of Maximum Operating Temperatures <strong>and</strong> Accident Conditions for<br />