Former Approach for FP Release Calculation<br />

• FRESCO-II: Fission product release calculation for one or<br />

several representative fuel element(s)<br />

• Time averaged release rate of sphere is multiplied with <strong>the</strong><br />

<strong>to</strong>tal number of fuel elements <strong>to</strong> determine core release rate<br />

„x“ cor re passes<br />

‣ Conservative approach<br />

‣ No spatial distribution of fission product release<br />

‣ More detailed calculation method necessary<br />

(Fuel temperature [°C]<br />

<strong>HTR</strong>-<strong>Module</strong>, VSOP)<br />

A. Xhonneux Technical Meeting on Re-evaluation of Maximum Operating Temperatures <strong>and</strong> Accident Conditions for<br />

5<br />

<strong>HTR</strong> Fuel <strong>and</strong> Structural Materials, Vienna,10-12 June 2013