I hereby promulgate the Building Standard Law<br />
Enforcement Order.<br />
Signed: HIROHITO, Seal of the Emperor<br />
This sixteenth day of the eleventh month of<br />
the twenty-fifth year of Showa (November 16, 1950)<br />
Prime Minister<br />
YOSHIDA Shigeru<br />
Cabinet Order No. 338<br />
Building Standard Law Enforcement Order<br />
In accordance with the provisions of the Building<br />
Standard Law (Law No. 201 of 1950), the Cabinet<br />
establishes this Cabinet Order.<br />
Conten ts<br />
Chapter I General Provisions<br />
Section 1 Definition of Words Used and Methods<br />
of Calculation (Articles 1-2)<br />
Section 2 Examination of Qualification for<br />
Building Officials (Articles 3-9)<br />
Section 3 Fees for Application of the Confirmation<br />
(Articles 10-14)<br />
Section 4 Amount of Compensation (Articles<br />
15-18)<br />
Chapter II Structure in General<br />
Section 1 Openings Required for Taking in<br />
Light (Articles 19-20)<br />
Section 2 Ceiling Height, Height of Floor of<br />
Living Room and Methods of Dampproofing<br />
thereof (Articles 21*22)<br />
Section 3 Stairways (Articles 23-27)<br />
Section 4 Latrines and Sewers (Articles 28-35)<br />
Chapter III Strength of Structures<br />
Section 1 General Provisions (Article 36)<br />
Section 2 Structural Materials (Articles 37-39)<br />
Section 3 Wooden Construction (Articles 40-<br />
50)<br />
Section 4 Masonry Constructions (Articles 51-<br />
62)<br />
Section 5 Steel Prame Constructions (Articles<br />
63-70)<br />
Section 6 Reinforced Concrete Construction<br />
(Articles 71-79)<br />
Section 7 Plain Concrete Construction (Article<br />
80)<br />
Section 8 Structural Calculation<br />
_1_<br />
Clause 1 General Provisions (Articles 8182)<br />
Clause 2 Loads and External Forces (Articles<br />
83-88)<br />
Clause-3 Allowable Stress (Articles 89-93)<br />
Section 9 Special Provisions for Structural<br />
Calculation (Articles 94-106)<br />
Chapter IV Fireproof Construction, Fire-resisting'<br />
Construction, Fire-zone, etc.<br />
(Articles 107-116)<br />
Chapter V Facilities for Escape<br />
Section 1 Corridor, Escape Stairways and Exits<br />
(Articles 117-126) •E<br />
Section 2 Passages Necessary for Escape and<br />
Defense Against Fire within Building<br />
Site (Articles 127-129)<br />
Chapter VI Use Zone (Article 130)<br />
Chapter VII Height of Building (Articles 131-<br />
136)-<br />
Chapter VIII Miscellaneous Provisions (Articles<br />
137-143)<br />
Supplementary Provisions<br />
CHAPTER I General Provisions<br />
Section 1 Definition of Words Used and<br />
Methods of Calculation<br />
(Definition of Words Used)<br />
Article 1. In this Cabinet Order, the definition of<br />
the words used in the following items shall b3 as<br />
termed in each item concerned :<br />
(1) Building site: means a parcel of land where<br />
one or more than two buildings occupy which<br />
cannot be separated on account of the use;<br />
(2) Basement: means a story with its floor lower<br />
than ground level but the height from its floor<br />
to ground level is higher than 1/3 of the ceiling<br />
height of that story;<br />
(3) Principal structural parts: mean walls,<br />
columns, trusses, sills, bracings, (angle braces,<br />
materials for horizontal bracings or the like),<br />
or horizontal members of a building, (beams,<br />
girders, or the like) that sustain dead and live<br />
loads, snow load, wind load, earth pressure or<br />
water pressure or impact due to earthquake<br />
and other tremors and vibrations;<br />
(4) Waterproofed materials: mean the building<br />
materials with waterproofing quality such as<br />
brick, stone, artificial stone, concrete, asphalt<br />
chinaware, glass and other similar materials.
(Methods of Calculation of Area, Height, etc.) |<br />
Article 2. The methods of calculation of area,<br />
height and number of story mentioned in the<br />
following items shall be as determined in each<br />
item concerned :<br />
(1) Area of building site: to take the area of<br />
horizontal projection. However, the site in part<br />
between the line considered as the boundary line<br />
of the road and the road as provided for in the<br />
provisions of Article 42 paragraph 2 of the<br />
Building Standard Law (hereinafter referred to<br />
as "Law") shall not be included in the area of<br />
the site;<br />
(2) Building area: to be the area of horizontal<br />
projection of part surrounded by the center<br />
line (in caseN there is a projection exceeding<br />
one meter from the center line concerned as of<br />
eave, pent-roof, balcony, and other similar ones,<br />
the line measured back horizontally from the<br />
edge of the same, 1 meter of exterior walls or<br />
the columns taking place of these in a building<br />
(excluding a part of basement below imaginary<br />
line drawn 1 meter above the ground level) ;<br />
(3) Floor area: to be the area of horizontal<br />
projection of a part surrounded by center line<br />
of walls and other partitions in each floor or its<br />
part of a building;<br />
(4) Total floor area: to be the total of floorarea<br />
of each story of a building except that, in the<br />
case coming under Article 56 paragraph 3 of<br />
the Law, no floor area of basement shall be<br />
included ;<br />
(5) Height of building: to be the height above<br />
the ground level; however, in the case coming<br />
under any one of the following items, it shall<br />
be as provided for in each item concerned;<br />
(a) For calculation of height according to the<br />
provisions of Article 57 or Article 58 of the<br />
Law, it shall be measured from the road<br />
surface at center of the road in front;<br />
(b) In case the total area of horizontal projection<br />
of staircase, elevator towers, decorative<br />
towers, •Ewatch towers, dormer windows and<br />
other similar part above roof of a building is<br />
less than 1/8 of the building area, the height<br />
of that part shall not be counted in determining<br />
the height of building concerned up<br />
to 12 meters;<br />
(c) A part of crest, fire wall projecting above<br />
roof and other similar projections above roof<br />
shall not be counted in determining the height<br />
of the building concerned.<br />
(6) Height of eave: to be the height measured<br />
from ground level to the top of wall supporting<br />
roof truss or horizontal member taking its place;<br />
wall plate or columns;<br />
(7) Number of story: no elevator towers, decorative<br />
towers, watch towers (or a part above roof<br />
of other similar building or storerooms, machine<br />
-2<br />
room of basement and part of other similar<br />
building of which each total horizontal projected<br />
area is less than 1/8 of building area concerned)<br />
shall be counted in number of story, or in case<br />
a part of a building has open inner court, or in<br />
case building site is sloped or stepped and when<br />
number of story differs by parts of these stories,<br />
the longest one shall be taken.<br />
2 Ground level mentioned in preceding item (2),<br />
(5) or (6) means the horizontal face imagined to<br />
exist at the average height where the perimeter<br />
of the building comes in contact with the ground<br />
surface, while in case the location of contact has<br />
the difference of elevation more than 3 meters, it<br />
shall be the horizontal face in average height at<br />
all points where the difference of elevation is<br />
kept within 3 meters.<br />
3 The method of calculation of horizontal projection<br />
for the case coming under paragraph 1 item<br />
(5) (b) or item (7) shall follow the method of ^<br />
calculation of building area of item (2) of the<br />
same paragraph.<br />
Section 2 Examination of Qualification of<br />
Building Official<br />
(Standard for Examination of Qualification)<br />
Article 3. Examinations of qualification of building<br />
official (hereinafter referred to as "examination<br />
of qualification") prescribed in the provisions of<br />
Article 5 of the Law shall be conducted to test<br />
the knowledge and experience on technical matters<br />
of building and regarding laws and ordinance<br />
required for confirmation provided for in the<br />
provisions of Article 6 paragraph 1 of the Law<br />
with respect to all buildings.<br />
(Methods of Examining Qualification)<br />
Article 4. Examination of qualification shall be<br />
conducted based on deliberation of past records<br />
and test.<br />
2 The deliberation of past records mentioned in<br />
the preceding paragraph shall be conducted on<br />
the records of actual performance concerning the<br />
building administration or building construction<br />
work.<br />
3 The test mentioned in paragraph 1 shall be<br />
conducted on the subject matters given in the<br />
following items. However, for person qualified<br />
as first class architect, the test on subject given<br />
in the items (1) to (5) inclusive shall be exempted:<br />
(1) Designing of building;<br />
(2) Planning of building;<br />
(3) Structure of building;<br />
(4) Building materials;<br />
(5) Execution of building construction;<br />
(6) Building Standard Law and Orders based on<br />
Building Standard Law ; ^<br />
(7) Laws and Regulations relating to City Planning<br />
(Law No. 36 of 1919)and Fire Defence Law
(Law No. 186 of 1948) and outline of Orders<br />
based thereon ;<br />
(8) Necessary Knowledge on building administration<br />
other than that mentioned in the preceding<br />
two items.<br />
(Execution of Examination of Qualification)<br />
Article 5. Examination of qualification shall be<br />
executed more thah once every year.<br />
2 The date and time as well as place for taking<br />
examination of qualification shall be announced to<br />
the public by the Minister of Construction through<br />
the Official Gazette beforehand.<br />
(Granting of Certificate of Passing Examination)<br />
Article 6. Minister of Construction shall grant the<br />
certificate of passing the examination of qualification<br />
for building officials to those persons who<br />
have passed the examination of qualification.<br />
(Fixed Number of Members of Committee for<br />
Examination" of Qualification)<br />
Article 7. Number of members of the Committee<br />
for Examination of Qualification for building<br />
officials shall be not more than 10.<br />
(Duty and Service of Members of Committee for<br />
Examination of Qualification)<br />
Article 8. The members of Committee of Examination<br />
of Qualification shall be of part-time service.<br />
(Entrusting to Ministerial Ordinance) •E<br />
Article 9. The procedures regarding the application<br />
for examination of qualification shall be<br />
determined by Ministry of Construction Ordinance.<br />
Section 3 Fees for Application for Confirmation<br />
(Fees for Application for Confirmation regarding<br />
Buildings)<br />
Article 10. The amount of fees for application for<br />
confirmation provided for in the provisions of<br />
Article 6 paragraph 5 of the Law (including the<br />
case where this applies mutatis mutandis in<br />
Article 87 paragraph 1 of the Law) shall be as<br />
shown in the following table for each separate<br />
case of application for confirmation :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
_3-<br />
2 The total floor area mentioned in the Table of<br />
the preceding paragraph shall, in case of building<br />
a building, be calculated on the total floor area<br />
of the parts of building concerned, and in case<br />
of large scale repairing or remodelling or change<br />
of use of a building, it shall be calculated as 1/2<br />
of the total floor area of the part pertaining to<br />
repairing, remodelling or change of use concerned.<br />
(Fees for Application for Confirmation regarding<br />
Structures)<br />
Article ll. The amount of fee for application for<br />
confirmation of structure in accordance with the<br />
provisions of Article 138 shall be ¥500 for each<br />
case of application for confirmation of structure.<br />
(Fee for Confirmation in Case of Combined<br />
Application for Confirmation of Building and<br />
Structure)<br />
Article 12. The amount of fee for application for<br />
confirmation in case of the applications for confirmation<br />
for building and structure in one application<br />
for confirmation shall be determined in<br />
accordance with the amount of fee for application<br />
for confirmation as in the provisions of Article 10<br />
for building concerned,* however, in case its<br />
amount is less than ¥500, it shall be at ¥500.<br />
(Reduction of Fee for Application of Confirmation)<br />
Article 13. In case the administrative agency concerned<br />
deems it necessary for the sake of public<br />
interest due to disasters and other special reasons<br />
may, irrespective of the provisions of the preceding<br />
three Articles reduce the fee for application<br />
for confirmation as provided for by the regulations<br />
of the local public entity concerned.<br />
(Ways of Paying Fee for Application for Confirmation)<br />
Article 14. The ways of paying fee or application<br />
for Confirmation shall be determined by the<br />
regulation of the local public entity concerned.<br />
Section 4 Amount of Compensation<br />
(Application for Decision of Expropriation<br />
Council)<br />
Article 15. Person (hereinafter referred to as<br />
"applicant") who intends to request the decision<br />
of Expropriation Council in accordance with the<br />
provisions of Article ll paragraph 3 of the Law<br />
(including the case where this applies mutatis<br />
mutandis in Article 88 of the Law) shall submit<br />
to the Expropriation Council on application inscribed<br />
with the matters enumerated below through<br />
the hand of the governor of To, Do, Fu or prefecture<br />
where the building concerned is located :<br />
(1) Name and address of the applicant;<br />
(2) Place where the building is located;<br />
(3) Rights possessed by the applicant regarding<br />
the building concerned ;<br />
(4) Use and brief description of structure of the
uilding, plot plan, block plan and floor plan of<br />
each story; however, the items not concerned<br />
with the disposal ordered may be omitted ;<br />
(5) Disposal ordered by the Special Administrative<br />
Agency in accordance with the provision<br />
of Article ll paragraph 1 of the Law;<br />
(6) Notified amount of compensation and the<br />
date when the notice was received;<br />
(7) The objectionable reasons against the amount<br />
of the notified compensation and the amount<br />
that applicant requests and particulars thereof ;<br />
(8) Excluding the matters that the applicant<br />
deems necessary in addition to those enumerated<br />
in the preceding items.<br />
2 In case the applicant submits an application in<br />
accordance with the provisions of the preceding<br />
paragraph, one copy of the application mentioned<br />
in the said paragraph shall be submitted to the<br />
governor of To, Do, Fu or prefecture mentioned<br />
in the preceding paragraph.<br />
(Written Opinion Submitted)<br />
Article 16. When the governor of To, Do, Fu or<br />
prefecture receives the application in accordance<br />
with the provision of paragraph 2 of the preceding<br />
Article one of the copies shall be sent without<br />
delay to the head of city, town or village where<br />
the building concerned is located.<br />
2<br />
The head of city, town or village who receives<br />
a copy of application prescribed in the provision<br />
of the nrecedine paragraph shall, within 10 days<br />
from the date of receipt of the same, prepare his<br />
written opinion for the application concerned<br />
which shall be submitted to the Expropriation<br />
Council.<br />
(Expropriation Council in Session)<br />
Article 17. The governor of To, Do, Fu or prefecture<br />
shall, within the period of time reckoning<br />
two weeks after submitting of the application in<br />
accordance with the provision of Article 15 but<br />
not exceeding one month, call the meeting of<br />
Expropriation Council.<br />
(Sending of Attested Copy of Written Decision)<br />
Article 18. In case the governor of To, Do, Fu or<br />
prefecture receives the report of the decision<br />
from the Expropriation Council, the attested<br />
copies of the written decision shall be delivered<br />
to the applicant and the head of city, town or<br />
village where the building concerned is located.<br />
CHAPTER<br />
II<br />
Structure in General<br />
Section 1 Openings Required for Taking in<br />
Light<br />
(Taking in Light to Living Rooms of School,<br />
Hospital, Dormitory, etc.)<br />
Article 19. The ratio of area of part effective for<br />
taking in light by means of windows and other<br />
openings in living room of school, hospital,<br />
medical office, dormitory or lodging house, etc.<br />
prescribed by the provisions of Article 28 paragraph<br />
1 of the Law to the area of that floor shall<br />
be larger than that as specified by the following<br />
table for each case:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
(Method of Calculating Effective Area)<br />
Article 20. The effective area for lighting by means<br />
of windows and other openings (hereinafter referred<br />
to as "opening" in this Article) of living<br />
room prescribed in the provisions of Article 28<br />
paragraph 1 of the Law shall be calculated at the<br />
part of opening falling under each of the following<br />
items:<br />
(1) In respect to the part of "opening" facing<br />
the boundary line of adjacent lot or other<br />
building or other part of the building concerned<br />
within the same lot, the distance from each<br />
part directly above the opening in question of<br />
the building (if there is recession from perpendicular<br />
face directly above the opening, or<br />
projecting part to include such part, and if<br />
there is semi-transparent pent roof or other<br />
pent roof not obstructing for taking in light,<br />
such shall be excluded) measured horizontally<br />
to the boundary line of adjacent lot or to<br />
opposite part of the building or other part of<br />
building concerned in the same lot, and the<br />
ratio of the measured distance to the vertical<br />
distance from the part in question to the opening<br />
in question to be larger than that given in<br />
the following table :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
(2) In respect to the opening facing the boundary<br />
line of adjacent lot in a zone or district given<br />
in item (2) or item (3) of the table of the<br />
preceding item or other building or other part<br />
of building concerned in the same lot that the<br />
~-f<br />
4
horizontal distance prescribed in said item to<br />
be more than 5 meters;<br />
(3) Part of opening facing the road, (in cityplanning<br />
district, road under the provision of<br />
Article 42 of the Law; hereinafter the same)<br />
park, open space, river, or vacant lot or surface<br />
of water.<br />
2 Part of area of sky-light effective for light shall,<br />
in regard to the application of the provisions of<br />
Article 28 paragraph 1 of the Law, b3 taken as 3<br />
times the area of that part.<br />
3 In case there is on.the outside of an opening a<br />
verandah wider than 90 cm., or other of the<br />
similar construction (excluding open verandah or<br />
the like), the application of the provisions of<br />
Article 28 paragraph 1 of the Law regarding the<br />
effective area of lighting of that part shall be<br />
considered as 7/10 of area of that part.<br />
Section 2 Ceiling Height, Height of Floor<br />
and the Method of Damp-proofing<br />
thereof<br />
(Ceiling Height of Living Room)<br />
Article 21. Ceiling height of a living room shall<br />
be more than 2.1m.<br />
2 Class room of a school (excluding various schools<br />
and kinder gartens) which floor area exceeds.<br />
50 sq.m. the height of ceiling shall be 3m. or<br />
over irrespective of the provisions of the preceding<br />
paragraph.<br />
3 Where the floor area for seating space for<br />
theater, cinema, show-house, place of review,<br />
auditorium or meeting place exceeds 200 sq. m.<br />
the ceiling height shall be more than 4m. irrespective<br />
of the provision of paragraph 1, except<br />
in case there is mechanical ventilating devise<br />
installed.<br />
4 Ceiling height of each preceding paragraph shall<br />
be measured from the level of the room. Where<br />
there are several ceiling heights in the same<br />
room, average height shall be taken as its ceiling<br />
height.<br />
(Height of Floor of Living Room and"the Method<br />
of Damp-proofing)<br />
Article 22. Height of floor and the damp-proofing<br />
methods for the case where the floor of living<br />
room in the lowest story is built of wood, it<br />
shall be done according to the provisions of the<br />
following items, except in cases where plain<br />
concrete or Tataki or other means corresponding<br />
thereto of disposal effective for damp-proofing are<br />
placed below floor :<br />
(1) The height floor shall be more than 45cm.<br />
measured from ground level directly below and<br />
to the top of floor level;<br />
(2) In exterior walls below floor level, holes with<br />
area of 300sq. cm. or over for the purpose of<br />
ventilation shall be provided at every or less<br />
than 5m. measured along the length of wall,<br />
and they shall be provided with means to<br />
prevent rats from going there.<br />
Section 3 Stairways<br />
(Width of Stairways and of its Landing, as well<br />
as Dimension of Rise and Tread thereof)<br />
Article 23. The width of stairways and its landing,<br />
as well as the dimensions of rise and tread thereof<br />
shall be as shown in the following table.<br />
However, the width of exterior stairways shall be<br />
60 cm. or over, and stairways (excluding stairs in<br />
apartment for common use) for use of residence<br />
may have its rise 23cm.or less and tread 15cm.<br />
or over:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
2 The dimension of tread of part forming circular<br />
stairs shall be measured at point 30 cm. from the<br />
end with the least width of tread.<br />
(Location and Tread-length of Landing)<br />
Article 24. Stairways coming under item 1) or<br />
item 2) of the table given in paragraph1 of the<br />
-5
preceding Article, and having their height more<br />
than 3 meters shall be provided with landings so<br />
arranged to come at point less than 3 meters;<br />
other kind of stairs having height exceeding 4<br />
meters shall be provided with landings so arranged<br />
to come at point less than 4 meters.<br />
2 Tread-length of landing mentioned in the preceding<br />
paragraph for straight stairs in accordance<br />
with the preceding provision shall be 1.2 meters<br />
or over.<br />
(Railings for Stairways and Landings)<br />
Article 25. In case both sides of stairs and landings<br />
are not provided with side walls or with<br />
other means to take place thereof, they shall be<br />
provided with hand railings.<br />
2 For stairways with width exceeding 3 meters<br />
railing shall be provided running through preferably<br />
at middle except for stairs with rise less^<br />
than 15 cm. and tread more than 30cm.<br />
3 The provisions of the preceding two paragraphs<br />
shall not apply for a part of stairways of height<br />
less than 1 meter.<br />
(Ramp in Place of Stairs)<br />
Article 26. The ramp taking place of stairs shall<br />
satisfy the following requirements in each item:<br />
(1) Gradient.not to exceed 1 in 8;<br />
(2) Surface shall either be roughened or shall be<br />
finished with other materials not slippery.<br />
2 The provisions of the preceding 3 Articles (excluding<br />
part concerned with rise and tread) shall<br />
apply mutatis mutandis to the ramp mentioned<br />
in the preceding paragraph.<br />
(Stairways Solely for Special Use)<br />
Article 27. The provisions of Article 23 to Article<br />
25 inclusive shall not apply to the stairs for<br />
elevator machinery room, watch tower, and for<br />
others solely used for special purposes.<br />
Section 4 Latrines and Sewers<br />
-.6-<br />
(Light and Ventilation of Latrine)<br />
Article 28. Latrine shall have window opened<br />
directly to outside air for light and ventilation<br />
except for water closet which has means to take<br />
the place of window.<br />
(Construction of Bail-out Latrines)<br />
Article 29. Construction of bail-out latrines shall<br />
be as specified by the following items:<br />
(1) Soil pipe from urinal, tank for soil water<br />
and the periphery of upper mouth shall be<br />
constructed of waterproof materials, and in case<br />
it is to be constructed of waterproof materials<br />
of osmotic quality, the means to prevent water<br />
leaking shall be made the applying waterproof<br />
cement mortar or similar effective waterproof<br />
construction ;<br />
(2) Space below latrine shall be separated from<br />
other parts by finishing with waterproof materials;<br />
(3) Opening for bailing out shall not face directly<br />
a road with its lower part fixed at 10cm. of<br />
over above ground level, and it shall be provided<br />
with tight fitted door;<br />
(4) The space 30cm. to front and right and left<br />
sides of bail-out opening, the ground shall be<br />
covered with plain concrete, Tataki or other<br />
similar materials.<br />
(Structure of Privy Closet in Special Building and<br />
District)<br />
Article 30. In city planning section, the latrines<br />
for school, hospital, theater, cinema, showhouse,<br />
place for review, auditorium, meeting house,<br />
department store, hotel, Japanese hotel, dormitory,<br />
railroad station, and buildings for use specified<br />
by the local public entity by its regulations and<br />
public latrines shall be constructed as prescribed<br />
in the following items :<br />
(1) To provide with non-water-penetrating stand<br />
and urinals;<br />
(2) Urinal shall be connected with soil pipe of<br />
non-water-penetrating quality to the soil tank ;<br />
(3) Window and other ventilating opening in<br />
latrine (in case there is no tight closing door<br />
in, latrine, a privy-closet) shall have insect<br />
metallic wire net to keep out flies.<br />
2 In case the local public entity deems that bailout<br />
latrines for building for use given in the<br />
preceding paragraph or buildings in the district<br />
designated by by-law should be replaced by the<br />
improved cess-pool, "Kairyobenso" mentioned in<br />
Article 31 from standpoint of sanitation, and that<br />
it can be maintained effectively, it may require<br />
to install Kairyobenso instead by the same bylaw.<br />
(Construction of "Kairyobenso")<br />
Article 31. "Kairyobenso" shall be according to<br />
the requirements given in the following items,<br />
excepting those having special structural quality<br />
which the administrative agency concerned recognizes<br />
as having equivalent or superior effect<br />
from stand point of sanitation :<br />
(1) Soil tank will be tank composed of retaining<br />
chamber and bail-out chamber in combination;<br />
(2) Ceiling, bottom, side walls and partition<br />
walls of soil tank shall be constructed of water-<br />
•E proof materials and shall be finished with<br />
waterproof mortar or by similar equally effective<br />
waterproofing methods to prevent any<br />
water leakage ;<br />
(3) Retaining chambers shall be composed of<br />
two or more chambers with part to keep soil<br />
water at depth of 80cm. or more at the same<br />
time its volume to be more than 0.75 cu,m.,<br />
and so arranged that soil water may be retained<br />
over 100 days;<br />
(4) There shall be provided proper sized opening<br />
in the retaining chamber for purposes^of cleaning<br />
thereof, and it shall be installed as tight<br />
fit;<br />
V
(5) The end of soil pipe from urinal shall enter<br />
retaining chamber at a point 40cm. or more<br />
below the surface of retaining soil water.<br />
(Soil Disposal Tank for Water-closet)<br />
Article 32. Soil disposal tank under the provisions<br />
of Article 31 paragraph 2 of the Law shall be so<br />
constructed as required by each item given below<br />
which permits decomposition of the liquefied soil<br />
matters to the extent that it shall not be objectionable<br />
from stand point of sanitation, excepting<br />
those of special construction which the administrative<br />
agency concerned recognizes as having<br />
equivalent or superior clarifying effect as compared<br />
with other accepted ones : •E<br />
(1) Soil disposal tank shall be constructed by<br />
combining the orders of treatment by decomposing<br />
chamber, oxidizing chamber, and<br />
chlorination chamber ;<br />
(2) Ceiling, bottom, side walls, partition walls<br />
shall be constructed of waterproof materials,<br />
and shall be finished by waterproof mortar or<br />
by other equally effective waterproof finishing<br />
safe against any. water leaking ;<br />
(3) Manhole of size with inside diameter 45cm.<br />
or over shall be provided over decomposing<br />
chamber, oxidizing chamber and disinfecting<br />
chamber ;<br />
(4) Decomposing chamber shall be constructed<br />
composed of setting and separating chambers<br />
and primary filtration chamber ;<br />
(5) The depth of part of decomposing chamber<br />
where soil water is retained shall be 1.2 meters<br />
or over, its volume shall be0.75 cu. m., or over<br />
up to the capacity for 15 persons using the<br />
watercloset concerned, and the size to be<br />
enlarged to meet the increase in persons using<br />
proportionately ;<br />
(6) Oxidizing chamber shall be of distributing<br />
filtration type and shall be 'provided with<br />
ventilating equipment such as air drawing pipe<br />
and air supply pipe;<br />
(7) The distance from the bottom of water<br />
sprinkling trough of oxidization chamber to<br />
the top of crushed stone layer shall be more<br />
than 10 cm. the thickness of crushed stone<br />
layer shall be 90cm. or over: the volume of<br />
crushed stone layer shall be more than 1/2 the<br />
volume of part of decomposing chamber where<br />
soil water is retained: the distance from the<br />
bottom of the supporter of crushed stones and<br />
the bottom of the tank shall be 10cm. or over.<br />
(Test for Water Leakage)<br />
Article 33. Tank for Kairyobenso of Article 31 and<br />
soil disposal tank mentioned in the preceding<br />
Article shall be tested for leakage by filling the<br />
tank with water for more than 24 hours.<br />
(Distance from Closet to Well)<br />
Article 34. Tank for bail-out-latrine shall not be<br />
located at distance less than 5 meters from a<br />
-7-<br />
well. However, in enclosed type well which is<br />
covered with fill of 3m. or over below ground<br />
level with water drawing pipe made of water<br />
tight material, or in case of using outside casing<br />
of water tight pipe with inside diameter 25 cm.<br />
or less while water drawing pipe inside thereof<br />
is also made of water tight material, the distance<br />
may be 1.8m. or over.<br />
(Materials for Sewage Pipe, etc.)<br />
Article 35, Sewage pipe, sewage channel or catch<br />
basin and other similar facility prescribed by the<br />
provisions of Article 19 paragraph 3 of the Law<br />
shall be constructed of waterproof materials or<br />
cast iron.<br />
CHAPTER 111 Structural Calculation<br />
Section 1 General Provisions<br />
(Fundamental Principle of "Structural Designing)<br />
Article 36. In making structural designing for a<br />
building, columns, beams, floors, walls, etc. shall<br />
be arranged effectively and safe against dead load, •E<br />
live load, snow load, wind pressure, eartE pressure<br />
and water-pressure and impact of earthquake<br />
and vibrations of earthquake & others<br />
acting on a building according to the kind of its<br />
•Estructural composition.<br />
2 In case a wall as a principal structural part of<br />
a building is considered to resist against the<br />
horizontal force acting on building, such wall<br />
shall be arranged well balanced, so far as it<br />
serves the purpose of use.<br />
3 Principal structural parts of a building shall be<br />
designed as ridged to cause no distortion objectionable<br />
to purpose of use.<br />
4 Footing of a building shall be designed structurally<br />
against unbalanced settlement and freezing.<br />
Section 2 Structural Materials<br />
(Lasting Quality of Structural Materials)<br />
Article 37. A part of timber used in principal<br />
parts from standpoint of lasting quality of structure<br />
that comes in contact with bricks, concrete,<br />
earth or other similar materials of water absorbent<br />
quality (excluding part that comes in<br />
contact with Shinkabe or walls of Dozo construction)<br />
shall be coated with decay protective paint<br />
or make disposal for preventing rotting by effective<br />
means equal to or superior thereof.<br />
2 Part of wall of a building that comes in contact<br />
with earth directiy> excluding such cases as of<br />
gate, fence, storage house, shed or other similar<br />
classes of building shall be constructed of water<br />
proof materials.<br />
3 In case wood piles are used as foundation of a<br />
building, excluding those used for one story<br />
wooden building, they shall be driven down below<br />
the surface of normal level of the standing<br />
water.
(Prevention of Wearing out)<br />
Article 38. In structural part of a building, liable<br />
to get easily worn out, material that resists wear<br />
shall be used or that part shall be covered with<br />
wear resisting materials to prevent any objectionable<br />
trouble.<br />
(Keeping Curtain Wall and Roof Tiles in Place)<br />
Article 39. Curtain wall shall be fixed to the building<br />
frames.<br />
2 Roof tiles shall be so placed that each tile in<br />
two rows along eave and sides and one in every<br />
5 tiles in other parts are fixed to the groundstrips<br />
with copper wire, iron wire or nails, or by<br />
other ways equally effective or better for keeping<br />
them from falling down.<br />
3 Decorative stones, terra cotta and the like shall<br />
be fixed to frames or to walls with bolts, spikes<br />
and other iron wares.<br />
Section 3 Wooden Construction<br />
(Scope of Application)<br />
Article 40. The provisions of this Section shall<br />
apply to part of wooden construction in a wooden<br />
building or building constructed of wooden construction<br />
combined with masonry or other construction<br />
and others, excepting those buildings<br />
such as Chashitsu, Azumaya or the similar buildings,<br />
or storage, shed or the like with total<br />
floor area less than 10 sq.m.<br />
(Timbers or Lumber)<br />
Article 41. Quality of lumber to be used in principal<br />
structural parts shall be free from defects<br />
such as knot, rot, slope of grain, rounded corners,<br />
etc. affecting structural strength.<br />
(Sills)<br />
Article 42. For principal structural column used<br />
in lowest §tory, its base shall be placed on asill,<br />
except in the case where column is firmly tiedto<br />
footing or foot of column or in the case where<br />
one story house is fixed on a base.<br />
2 Sill shall be firmly tied to footing except forone<br />
story building with the total floor area less than<br />
50 sq.m.<br />
(Least Diameter of Column)<br />
Article 43. Least diameter of principal structural<br />
column shall be not less than the ratio shown in<br />
the following table against the perpendicular distance<br />
between each horizontal member of principal<br />
structural part such as sill, base, girt, beam,<br />
girder and other horizontal structural members<br />
that are connected thereto :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
-8-
2 In cases where, by regulation and in accordaic.3<br />
with the provisions of Article 41 of the Law,<br />
whole or part of the provision of Article 21 paragraph<br />
1 of the Law is not applicable or in cases<br />
where, the restrictions of the provision of the<br />
same paragraph are to be alleviated by the same<br />
regulation and by supplementing the provisions<br />
of the preceding paragraph, the ratio between<br />
the least diameter of column and the perpendicular<br />
distance of horizontal members shall be<br />
determined.<br />
3 In case more than 1/3 of required cross section<br />
of column calculated on the basis of least diameter<br />
mentioned in the provisions of the preceding<br />
two paragraphs is to be cut out, that part<br />
shall have to be properly rain forced.<br />
4 Corner columns of 2 story building or higher or<br />
columns acting as such shall be one continuous<br />
through-column unless they are properly reinforced<br />
at the joint to give the same or higher<br />
strength than one continuous through-columns.<br />
(Horizontal Members such as Beam, etc.)<br />
Article 44. No objectionable cut on tension side<br />
about the middle of beam, girder or in other<br />
horizontal members shall be allowed.<br />
(Bracing and Joints)<br />
Article 45. Bracing acting as tension member shall<br />
be wood of size larger than 1/5 of column with<br />
which it is in contact or steel far larger than<br />
9 mm. in diameter, or other steel members having<br />
equivalent strength.<br />
2 Bracing acting as compression member shall be<br />
wood of size larger than 1/3 of column with<br />
which it is in contact.<br />
3 Ends of bracing mentioned in the preceding two<br />
paragraphs shall be firmly connected near at the<br />
joints in column, beam or other horizontal member<br />
by means of holt, spike, nails or other irons.<br />
4 Bracing members shall not be cut out.<br />
(Framing Necessary for Strength)<br />
Article 46. In wooden buildings, walls, columns<br />
and horizontal members of principal parts necessary<br />
for structural strength in direction of spacing<br />
of beams and in direction of wall girders of<br />
each story, framings with wall or bracings shall<br />
be arranged well balanced to be safe against<br />
horizontal forces acting in all directions, except in<br />
the case where brackets, column buttress, wall<br />
buttress are provided propejly to stand against<br />
acting forces.<br />
2 In corners of floor frame and roof truss systems<br />
shall use horizontal bracing members and roof<br />
trusses shall be provided with vertical bracings.<br />
3 In wooden buildings of 2 or more stories or<br />
with total floor area exceeding 50 sq.m. the<br />
required length of framing with wall or bracings<br />
laid out in direction of span of beam as well as<br />
direction of side wall girders in each story according<br />
to the provisions of paragraph 1 shall be<br />
-9-<br />
not less than the respective value per 1 sq.m.<br />
of floor area of that story shown in the following<br />
table: However, in the case within the district<br />
where the special administrative agency<br />
designates the seismic constant for horizontal<br />
force at 0.3 or higher in accordance with the<br />
provisions of Article 88 paragraph 3, it shall be<br />
2 times that value.<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
More than half of the lengths of framing in accordance<br />
with the provisions of the preceding<br />
paragraph shall be framing with bracings in.<br />
The frames in the following table shall, in applying<br />
the provision of the preceding two para<br />
graphs, be considered as having the length<br />
obtained by multiplying each length with double<br />
the value as given in each item concerned:
6)<br />
Frame with wall effective a-<br />
gainst horizontal force such as<br />
earth-plaster wall, plaster on<br />
wooden lath and others<br />
7)<br />
Frame with bracings in item (1)<br />
Sum of<br />
to item (5) inclusive and wall<br />
value of<br />
each item<br />
in item (6) combined<br />
conce rned<br />
(Joints or Connections in Principal Structural<br />
Parts)<br />
Article 47. Connection or joint as principal structural<br />
part shall be tied properly to transmit full<br />
existing stress in that part by using bolts, spikes,<br />
pins or other similar methods.<br />
(Wooden School Building for Elementary or Middle<br />
School)<br />
Article 48. Walls, columns and horizontal members<br />
of wooden school building for elementary or<br />
lower secondary school shall be as prescribed in<br />
the following items except in the case where<br />
they accord with Article 12 of Japanese Building<br />
Specifications "Wooden elementary school (Building<br />
1302)" or with Article 13 of "Wooden lower<br />
secondary school (Building 1303)" as provided for by<br />
the competent Minister. However, school or class<br />
room built by special structural method or other<br />
schools of smaller type that the special administrative<br />
agency recognizes as having equal or<br />
higher strength as compared with those under<br />
these specifications or under the provisions in<br />
each item:<br />
(1) Bracings mentioned in Article 46 paragraph<br />
5 table item (3) shall be used in exterior walls;<br />
(2) In case the distance in direction of side wall<br />
girder is over 12 m. in direction of side wall<br />
girder at interval of 12 m. or less shall have<br />
through partition wall of property spaced bracings<br />
mentioned in Article 46 paragraph 5 table<br />
item (3) unless buttress-columns or buttresswalls<br />
of equal or higher strength are provided<br />
at<br />
(3)<br />
proper space;<br />
Columns beams and trusses shall ba arranged<br />
to be located at distance not exceeding 2 m. in<br />
direction of side wall girder (4 m. in indoor<br />
gymnasium or other large scale room) and columns<br />
and beams or trusses shall be tied firmly<br />
by using bracings of size larger than £ of column;<br />
(4) Column as principal structural part shall be<br />
15 cm. sq. or more or having equivalen<br />
strength. +<br />
(Disposal for Prevention of Rot in Interior of<br />
Exterior Walls)<br />
Article 49. In case whole or part of the exterior<br />
walls of wooden frame is to be finished with cement<br />
mortar on metal lath or ashlared stone<br />
facing and other construction that frames are<br />
easily eaten by rot, water-proofing paper shall be<br />
placed as ground for that part in addition to ap"<br />
plying creosote or other chemical to columns up<br />
0.5<br />
1 m. from ground level, bracings and sills in<br />
that part; provided that the interior of wall in<br />
that part is so constructed as to permit of air<br />
circulation.<br />
(Ashlaring)<br />
Article 50. In building construction with wooden<br />
frames to be faced with stones (including tile<br />
facing and the like, hereinafter the same in this<br />
Article), the thickness* of facing tiles shall be<br />
less than 5 cm. excepting the part up to 1 m.<br />
from the ground level.<br />
2 Facing stones of building mentioned in the preceding<br />
paragraph exceeding 1,5 cm. in thickness<br />
shall be tied to the framesby means of spikes,<br />
copper wire other similar non-corrosive metals to<br />
prevent them from falling off.<br />
Section 4 Masonry Construction<br />
10-<br />
(Scope of Application)<br />
Article 51. The provisions of this Section shall<br />
apply to part of masonry construction in masonry<br />
building such as brick construction, stone construction,<br />
concrete block construction and other<br />
masonry constructions, or part in building constructed<br />
of masonry construction combined with<br />
wooden construction or other. However, the<br />
provisions of this Section shall not apply to part<br />
reinforced by ferro-concrete or by steel shapes<br />
which proved to have equal or higher strength<br />
as compared with those satisfying the provisions<br />
of this Section by structural calculation or by<br />
experiment.<br />
2 The provisions of Article 55 paragraph 2 and<br />
Article 56 of this Section shall not apply to buildings<br />
lower than 4m and at the same time with<br />
its total floor area not over 20 sq.m.<br />
3 To structurally unimportant partition wall of<br />
less than 2 m. high, the provisions of this Section<br />
only from this Article to Article 53 inclusive,<br />
Article 55 paragraph 6 and Article 62 shall apply.<br />
(Execution of Masonry Constructions)<br />
Article 52. Brick, stones and concrete blocks and<br />
other masonry materials to be used in masonry<br />
construction shall be washed well before planning<br />
them.<br />
2 Masonry materials shall be placed so that cement<br />
mortar shall spread evenly over entire face<br />
of its joint.<br />
3 Mortar mentioned in the preceding paragraph<br />
shall be cement mortar, the mixture of cement<br />
and sandbyvolume shall be 1:3 or having<br />
strength equal or superior to this, and cement<br />
mortar with lime shall be in mixture of cement,<br />
lime and sand by volume in the proportion of<br />
1:2:5 or having strength equal or superior to<br />
this.<br />
4 Masonry construction shall be constructed to<br />
prevent straight joint.
(Foot i ng)<br />
Article 53. Footing to receive masonry wall shall<br />
be constructed of mass of plain concrete or reinforced<br />
concrete.<br />
(Length of Wall)<br />
Article 54. No masonry wall shall have its length<br />
over 10 m.<br />
2 Length of wall mentioned in this Section means<br />
the distance center to center of adjacent two<br />
walls measured at parts connected to that wall<br />
(including buttress whose length at part connected<br />
to footing is less than 1/3 of length of wallto<br />
which the buttresses are fixed. Hereinafter referred<br />
to in this Section, as "adjacent opposing<br />
walls").<br />
(Thickness of Wall)<br />
Article 55. Thickness of wall for masonry construction<br />
(not including the thickness of finishing<br />
materials ; hereinafter the same in this Section)<br />
shall bs not less than the value given in the following<br />
table in accordance with the number of<br />
story and the length of that wall (meaning the<br />
length of wall mentioned in paragraph 2 of the<br />
preceding Article) of that building respectively :<br />
(Unit in meter)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
2 Thickness of wall of masonry construction in<br />
each story shall be not less than 1/15 of the<br />
height of wall in that story.<br />
3 Thickness of wall for partition of masonry construction<br />
may be 10 cm. less than the thickness<br />
of walls prescribed in the provision of preceding<br />
two paragraphs, provided that the thickness of<br />
its wall is more than 20 cm.<br />
4 The thickness of wall constructed in combination<br />
of stones or stones and other masonry materials<br />
shall be not less than the value of the thickness<br />
of wall prescribed by the provisions of the preceding<br />
3 paragraphs increased by 2/10 of the<br />
thickness of that wall, excepting the steel framing<br />
stone construction.<br />
5 Regarding double-wall masonry building the provisions<br />
of the preceding 4 paragraphs shall apply<br />
to either one wall of that double-wall.<br />
6 Thickness of wall in each story of masonry<br />
building shall be not less than the thickness of<br />
respective upper walls bearing thereon.<br />
7 Regarding the thickness of curtain walls constructed<br />
of masonry in steel frame building, reinforced<br />
concrete construction or steel skeleton<br />
reinforced concrete construction, it shall be considered<br />
as partition upon application of the provision<br />
of this Article.<br />
(Wall Girder)<br />
Article 56. In the wall of masonry building, at the<br />
top of walls in each story (in cases where gable<br />
wall exists, top of wall of said gable) shall be<br />
placed the wall girder constructed of steel frame<br />
structure or reinforced concrete, except in cases<br />
where the reinforced concrete roof or slab etc.<br />
are placed over, or thickness of wall of one story<br />
building is more than 1/10 of height of wall, or<br />
where the length of wall is less than 5 m.<br />
-ll-<br />
(Openings)<br />
Article 57. Opening in walls of masonry building<br />
such as windows, exits, and others shall be as<br />
provided for in following items :<br />
(1) Total width of openings of each wall in<br />
section formed by adjacent-opposing-walls of<br />
each story shall be not more than 1/2 of the<br />
length of that wall;<br />
(2) Total width of openings in each story shall<br />
be not more than 1/3 of the total length of<br />
walls in that story;<br />
(3) Vertical distance from an opening to an,<br />
opening directly above shall be not less than<br />
60cm.<br />
2 Distance between openings in wall of each story<br />
in masonry building, or horizontal distance between<br />
opening and center line of adjacent-opposing-walls<br />
shall be more than twice the thickness<br />
of that wall,<br />
obopening is<br />
excepting<br />
reinforced<br />
the case where periphery<br />
with steel frame or reinforced<br />
concrete.<br />
3 At the top of opening wider than 1 m., reinforced<br />
concrete lintel shall be placed.<br />
4 Bay window or projected verandah of masonry<br />
construction shall be reinforced with stael skeleton<br />
or reinforced concrete.<br />
5 Masonry construction inside of wall fire-place<br />
shall have substantial footing to sustain the weight<br />
of fire-place and the chimney and its upper part<br />
shall not be stepped out. In case of wooden<br />
building it shall be reinforced by steel materials<br />
in addition.<br />
(Channel Cut in Walls)<br />
Article 58. In walls of masonry building, when<br />
vertical channel for continuous distance more<br />
than 3/4 of height of wall of that story is to be<br />
made, depth shall be less than 1/3 of the thick-
ness of the wall, and when horizontal channel is<br />
to be made, its depth shall bs less than 1/3 of<br />
the thickness of wall while the length shall not<br />
exceed 3 meters.<br />
(Wall of Wooden Frame Masonry Construction or<br />
Steel Frame Masonry Construction)<br />
Article 59. Part of masonry construction in the j<br />
wall of wooden frame or steel frame masonry<br />
construction shall be tied firmly into wooden<br />
frame or steel frame with bolts, spikes and other<br />
iron wares.<br />
(Hand Railing and Railing Wall)<br />
Article 60. Hand railing or railing wall shall no*t<br />
be constructed ©f masonry unless its top is tied<br />
by reinforced concrete wall girder.<br />
(Masonry Fence)<br />
Article 61. Masonry fence shall satisfy the following<br />
requirements :<br />
(1) Height shall not exceed 3 m.;<br />
(2) Thickness at any part of wall shall be more<br />
than 1/10 of the height, measured from that<br />
part to the top of that wall;<br />
(3) At every 4 m. or less of the length of wall,<br />
there shall be buttress walls (excluding wooden<br />
construction) projecting out of the face of wall<br />
more than 1.5 times its thickness, of that point<br />
unless the thickness of wall in that part is<br />
more than 1.5 of the wall thickness specified in<br />
the provisions of the preceding item.<br />
(Supports, etc. of Principal Structural Part for<br />
Structural Strength)<br />
Article 62. Principal masonry part shall not be<br />
supported by any part of wooden structure.<br />
Section 5 Steel Frame Construction<br />
(Scope of Application)<br />
Article 63. The provisions of this Section shall apply<br />
to part of steel construction in steel frame<br />
building, steel skeleton reinforced concrete building<br />
or building constructed of steel frame combined<br />
with other construction such as masonry,<br />
etc.<br />
(Materials)<br />
Article 64. No cast iron shall be used in part receiving<br />
stresses other than compression or stress<br />
caused by contact.<br />
(Effective Slenderness Ratio of Compression Member)<br />
Article 65. Effective slenderness ratio (ratio of<br />
buckling,length to the radius of gyration; hereinafter<br />
the same) of steel compression member<br />
(meaning material to take compressive stress;<br />
hereinafter the same) as principal part for structural<br />
strength shall not exceed 200 for column,<br />
250 for members other than column.<br />
(Foot of Column)<br />
Article 66. Foot of column as principal structural<br />
part shall be fixed to footing by anchor bolts<br />
-12-<br />
unless it is firmly fixed to footing by other special<br />
constructions or designed as pin support.<br />
(Joints)<br />
Article 67. Joints of steel shapes as principal<br />
structural part shall either be riveted or welded<br />
joint, except where bolts are permitted to be<br />
used as in the cases given in any of the follow-<br />
I<br />
I<br />
j<br />
i<br />
ing items:<br />
(1) In the case where total weight of steel<br />
shapes used in structural part of a building is<br />
less than 10 tons, and bolted part is embedded<br />
in concrete, or nuts are fixed by welding, or<br />
lock nuts are used so that bolts will not be<br />
loosened ;<br />
(2) In the case where the joint is extremely<br />
difficult for riveting or welding.<br />
2 Joints and connections as the principal structural<br />
part shall, by means of splice piece riveted<br />
or welding, be so constructed that entire stress<br />
existing at that point may be transmitted. In<br />
this case, the end of column shall be perfectly<br />
planed, and when no tension stress is not made<br />
to exist, by making the contact or joint good and<br />
tight, the structure may be considered as one of<br />
which that compression stress and bending<br />
moment at that point is transmitted up to 1/4<br />
(1/2 at foot of column).<br />
(Rivet and Bolt)<br />
Article 68. Spacing of rivet or bolt shallbe greater<br />
than 2.5 times its diameter center to center.<br />
2 Riveting shall be done so that rivet shall filland<br />
fit the hole perfectly tight.<br />
3 No holes for bolts shall be made larger than0.5<br />
mm.in diameter of bolt used.<br />
(Arrangement of Bracings, Walls, etc.)<br />
Article 69. Excluding the case where structures of<br />
upright framings, floor system and roof trusses are<br />
proved to be structurally safe through structural<br />
calculation, steel shape or bar bracings, or rein-<br />
forced concrete walls, roofslabor floor slabs shall<br />
be arranged to suit.<br />
(Prevention of Corrosion in Structural Materials)<br />
Article 70. Steel shapes used in principal structural<br />
"part shall be protected by non-corrosive<br />
paints or shall be embedded in concrete or in<br />
light protective concrete with no rust forming<br />
quality for steel.<br />
Section 6 Reinforced Concrete Construction<br />
(Scope of Application)<br />
Article 71. The provisions of this Section shall<br />
apply to part of reinforced concrete in reinforced<br />
concrete building, steel skeleton reinforced concrete<br />
building constructed of reinforced concrete<br />
combined with other construction such as mason"<br />
ry, etc.<br />
2 The provisions of Article 72, Article 75 and<br />
Article 79 of this Section only shall apply to
uildings of height less than 4 meters and with<br />
total floor area less than 30 sq.m., or to fence<br />
with height not over 3 meters.<br />
(Materials for Concrete)<br />
Article 72. Materials to be used for concrete in<br />
reinforced concrete buildings shall satisfy the<br />
requirements in the following items :<br />
(1) Sand, gravel, crushed stones and water shall<br />
be free from acids, salts, organic matters or<br />
particles of mud liable to cause rusting of steel<br />
or injurious to obstruct normal process of setting<br />
of concrete;<br />
(2) Gravel or crushed stones shall be hard and<br />
of size to go through easily between spaces in<br />
reinforcing bars and space between reinforcing<br />
bar and form.<br />
(Joints and Fixing of Reinforcing Bars)<br />
Article 73. Ends of reinforcing bars shall be hooked<br />
to prevent from slipping.<br />
2 Joint of main bar shall be at a partwhere<br />
tension stress acts least excepting the case of<br />
welding, the length of lap shall be more than 25<br />
times its diameter (in the case of making joints<br />
of main bars of different diameters, the smaller<br />
diameter; hereinafter the same in this Article).<br />
However, in case the joint may not be made at<br />
a point where tension is not working at full<br />
stress, then, the lap shall be more than 40 times<br />
the diameter or bars.<br />
3 Of the tension steel bars in beam framed with<br />
column, excepting the case of welding with main<br />
bars in column, the length of anchor shall benot<br />
less than 40 times its diameter.<br />
(Proportion of Concrete Mix)<br />
Article 74. Concrete to be used in reinforced concrete<br />
construction shall show compressive•E<br />
strength of more than 90 kg/cm2 at age of 28<br />
days.<br />
2 Water-Cement ratio of concrete shall be kept<br />
down from the value obtained by the following<br />
formula according to the required strength for<br />
structural purpose, except in cases where it is<br />
determined by the testing of strength by Japanese<br />
Industrial Standard A 1108 (Method of testing<br />
compression stress) :<br />
In case of<br />
Cement<br />
commonPortland<br />
In case of high early strength<br />
Portland Cement<br />
In case of slag cement or<br />
silica Cement<br />
0.85 K<br />
"F+0.64 IT<br />
0.47 K<br />
"F+0.05K<br />
1.4K<br />
"F+1.48K<br />
In above formula, F, K and x shall showthe<br />
following values respectively :<br />
F=Compressive strength of concrete at age<br />
of28 days given in table in Article 91.<br />
K=Compressive strength of mortar at age of<br />
28 days according to Japanese.<br />
Industrial Standard R 5210 for Portland<br />
Cement. However, in case the period of<br />
2 weeks after concrete is poured happens<br />
to fall on a month having average temperature<br />
for that month less than 10°C, the<br />
value of the stress to be decreased by 50<br />
kg/cm2.<br />
x-Water-Cement ratio<br />
3 Mixture of Concrete shall be determined so that<br />
the product shall be uniform, and compact.<br />
(Curing of Concrete)<br />
Article 75. Curing of concrete shall be done so as<br />
to keep the temperature of concrete above 2°C,<br />
while pouring and during the period of 5 days<br />
after concrete is poured and care shall be taken<br />
to prevent it from setting and hardening by dryout<br />
or vibration.<br />
(Removing of Supports of Forms)<br />
Article 76. Supports for forms for beams and slabs<br />
as principal structural part shall not be removed<br />
before 6 weeks (4 weeks in case of roof floor or<br />
in case of no floor bsing directly above).<br />
2 The provisions of the preceding paragraph shall<br />
not apply in case high early-strength Portland<br />
cement is used or other cement is used and in<br />
case } of the period of time or more mentioned<br />
in said paragraph has elapsed and only in case<br />
building official approves that he has no objection<br />
thereto from standpoint of structural strength<br />
due to favorable condition in respect to temperature,<br />
humidity and others.<br />
(Construction of Columns)<br />
Article 77. Construction of columns as principal<br />
structural part shall satisfy the structural requirements<br />
as provided for in the following items :<br />
(1) Main bars shall consist of more than 4 reinforcing<br />
bars with properly spaced ties ;<br />
(2) Spacing of ties shall be less than 30 cm.,<br />
and at the same time not over 15 times the<br />
diameter of smallest bars used ;<br />
(3) Least diameter of column shall be more<br />
than 1/15 of the distance between the main<br />
supports unless it is checked as safe in consideration<br />
of its slenderness ratio in structural<br />
calculation.<br />
(4) Sum of area of main bars shall be not less<br />
than 0.8% of the area of cross-section of concrete<br />
(if area of bar exceeds the area under<br />
the provision of the preceding paragraph or<br />
under the result of structural calculation, that<br />
required area,,<br />
(Construction of Beams)<br />
Article 78. Beam as principal part for structural<br />
strength shall be reinforced double, and shall<br />
have stirrups at space not exceeding 3/4 of the<br />
depth of a beam.<br />
(Thickness of Protection for Embedded Bars)<br />
Article 79. Thickness of concrete covering of the<br />
-13-
embedded bars shall be more than 2 cm. for<br />
walls not bearing wall, and slab, more than 3cm.<br />
for bearing walls, columns or beams (more than<br />
2 cm. for a part facing interior with effective<br />
finishing for protection of steel bars such as<br />
mortar, plaster, tiles or others) more than 4 cm.<br />
for walls, columns, slabs or beams which come<br />
in contact with earth directly, more than 6 cm.<br />
for footing not including the levelling concrete.<br />
Section 7 Plain Concrete Construction<br />
(Provisions of Section 4 and Section 6 which applies<br />
mutatis mutandis to Concrete Construction)<br />
Article 80. Regarding the structural part of plain<br />
concrete in plain concrete building or building<br />
constructed of plain concrete construction combined<br />
with other construction the provisions of<br />
Section 4 (excluding Article 52), and Article 71<br />
(except that part pertaining to Article 79), the<br />
provisions of Article 72 and Article 74 to Article<br />
76 inclusive in this Chapter shall apply mutatis<br />
mutandis.<br />
Section 8 Structural Calculation<br />
Clause 1 General Provisions<br />
(Application)<br />
Article 81. Structural calculation of buildings<br />
mentioned in the provisions of Article 20 paragraph<br />
2 of the Law shall be conducted according<br />
to the provisions of this Section excluding the<br />
case under the provision of Section 9, excepting<br />
the case where structural calculation is carried<br />
out by the accurate method of structural calculation<br />
recognized as equal or superior to that prescribed<br />
in the provisions of this Section by the<br />
Minister of Construction.<br />
(Principle of Structural Calculation)<br />
Article 82. Structural calculation under the preceding<br />
Article shall comply with the requirements<br />
of the following items:<br />
(1) Calculate the stress developed in principal<br />
part for structural strength of building caused<br />
by loads and external forces specified by the<br />
provisions of Clause 2;<br />
(2) Permanent and temporary stresses at principal<br />
part of structural strength mentioned in<br />
the preceding item shall be calculated by combining<br />
and summing up stresses by using the<br />
following table ;<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
-f<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
(3) To check and ascertain that the stresses of<br />
permanent and temporary stresses of preceding<br />
item do not exceed the allowable stress for<br />
permanent and temporary cases according to<br />
the provisions of Clause 3;<br />
(4) When necessary, to check and ascertain<br />
whether the determination of the principal<br />
structural part gives objectionable effect on the<br />
-14-<br />
use of building or not.<br />
Clause 2 Loads and External Forces<br />
(Kind of Load and External Force)<br />
Article 83. Loads and external force acting on a<br />
building shall be considered in accordance with<br />
those mentioned in the following items:<br />
(1) Dead load;
according to ttie actual condition of the building<br />
concerned.<br />
(Dead Loads)<br />
Article 84. Dead load of esch part of building<br />
shall be either values given in the following<br />
table or values obtained by figuring out according<br />
to the actual condition of the building concerned :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
-15-
(Live Loads)<br />
Article 85. Live load at each part of a building<br />
shall be determined according to actual condition<br />
of building concerned. However, live loads on<br />
floor given in this balow may be taken from the<br />
value as determined for each itsm concerned for<br />
calculation :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
auditorium, assembly hall<br />
and seatings or assembly<br />
room of similar use<br />
300 270<br />
160 Fixed seats<br />
Do, other than fixed seats<br />
360<br />
330<br />
210<br />
6) Garage and passageway<br />
for automobiles<br />
550<br />
400<br />
200<br />
7)<br />
8)<br />
Corridor, vestibule or<br />
stairways<br />
Open space on roof or<br />
balcony<br />
For room connected to those item (3) to item(5), the value of other<br />
cases of item (4)is to be taken<br />
Value of item(l) to be used. However, for buildings used as school<br />
or department store, take the value in item(4)<br />
16-
2 In the case of calculating compressive stress<br />
due to vertical loads on column or footing, the<br />
value of column (b) of the preceding paragraph<br />
may be reduced depending upon the number of<br />
floors it supports, down to the figure obtained by<br />
multiplying the value of the following table, excepting<br />
the floor-live loads for room mentioned in<br />
5) of the table in the same paragraph:<br />
<br />
<br />
<br />
3 If the live load for floor of commercial warehouse<br />
calculated according to actual condition by<br />
the provision of paragraph 1 is less than at kg.<br />
400 per sq.m., shall be taken at 400 kg. persq.m.<br />
(Snow Load)<br />
Article 86. Snow loads shall be figured by multiplying<br />
unit weight of snow with the deepest snow<br />
fall of the locality.<br />
2 Unit weight of snow in place as prescribed in<br />
the preceding paragraph, for one sq.m., be more<br />
than 3 kg. in heavy snow district and in other<br />
snow district 2, kg. or more.<br />
3 Maximum snow depth prescribed in paragraph 1<br />
shall be determined according to group of district<br />
under similar condition by referring to the past<br />
snow fall records, and the heavy snow district<br />
specified in the preceding paragraph shall be<br />
determined based on the standard arranged by<br />
the Minister of Construction in its regulation by<br />
the administrative agency concerned.<br />
4 Snow load on roof may, according to its slope,<br />
take the value obtained by multiplying the following<br />
value to the snow load in paragraph 1. However,<br />
if slope is steeper than 60 deg., it may be<br />
neglected. However, where there are strips to<br />
prevent snow from sliding down from roof, it<br />
shall be treated otherwise.<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
5 Snow load in heavy snow district prescribed in<br />
paragraph 3 treated as semi-permanent load may<br />
be reduced to 70% of the value obtained by calculating<br />
according to the provisions of the preceding<br />
four paragraphs and snow loads counted<br />
to act together with wind pressure or seismic<br />
force, it may be reduced to 35% thereof.<br />
6 If there is possibility of snow piling on roof in<br />
unbalanced way, its influence shall be considered<br />
in structural calculation.<br />
7 In locality where people are accustomed to removesnow<br />
from roof from time to time, even in<br />
case snow depth in that locality exceeds 1 m.,<br />
snow depth may be reduced, according, to the<br />
actual condition, to depth of 1 m. for calculation<br />
of snow load.<br />
(Wind Load)<br />
Article 87. Wind pressure shall be calculated by<br />
multiplying the coefficient of wind force to velocity<br />
pressure.<br />
2 Speed pressure of the preceding paragraph shall<br />
be calculated by the following formula ; however,<br />
the special administrative agency may designate<br />
the district by the regulation and may, on the<br />
-17-<br />
basis of the standard set forth by Minister of<br />
Construction in consideration of the wind condition<br />
of that locality, determines the speed pressure<br />
for that region within the sphere of 60% of<br />
that value, (40% in the snow country mentioned<br />
in the provision of paragraph 3 of the preceding<br />
Article) :<br />
q=60v/ h<br />
where h=Height above ground level in meter<br />
q=Speed pressure in kg. par sq. m.<br />
3 The velocity pressure against a building built in<br />
sea coast, river bank, up hill, over cliff, etc.<br />
where it directly exposes to strong wind, shall be<br />
taken at 300 kg. per 1 sq. m- or more.<br />
4 Where another building or wind defence forest<br />
or other similar facilities effective in protecting<br />
the building in the direction of wind, the value of<br />
velocity pressure in that direction may be reduced<br />
to 1/2 of the value specified in the provision<br />
of the preceding two paragraphs.<br />
5 The value of coefficient of wind "force in paragraph<br />
1 shall be as shown in the following diagrams<br />
according to sectional form of building or<br />
structure :
Form of plane<br />
board<br />
Type of structure |<br />
in closed form<br />
<br />
<br />
<br />
Type of structure<br />
open form<br />
in<br />
; open<br />
..<br />
-3 -5 -i^<br />
13<br />
x><br />
t^i<br />
Special administrative agency shall, on the basis<br />
of the standard set forth by Minister of Construetion,<br />
designate the district where ground is soft<br />
and bad as prescribed in 3) of the table in the<br />
preceding paragraph.<br />
Coefficient of seismic force acting on independent<br />
chimney away from building, or water tank and<br />
chimney projected from roof shall be 0.3 or over.<br />
However, for calculation of footing for independent<br />
chimney away from building may be reduced<br />
to0.2.<br />
Whereas building or independent chimney away<br />
from building, or water tank projected above roof<br />
or the like, is supported by solid foundation, and<br />
if proved that seismic force acting on the building<br />
is comparatively small, it may, regarding the<br />
building concerned, reduce the values of coefficient<br />
of seismic force in 1) or 2) of the table in<br />
paragraph 2 by 1/4 for each case on the basis of<br />
the standard set forth by the Minister of Construction.<br />
(Timber)<br />
Clause 3<br />
Allowable<br />
Stress<br />
Article 89. The values of allowable stress indirection<br />
of grain of timber shall be according to the<br />
following table :<br />
Species of timber<br />
Needle leaf<br />
trees<br />
Broad leaf<br />
trees<br />
Allowable<br />
stress<br />
Sugi, white fir, silver<br />
fir, Todomatsu (kind<br />
of fir), western red<br />
cedar, hemlock-spruce<br />
Swamp cypress,<br />
Beihi<br />
Hinoki,<br />
black<br />
red<br />
pine,<br />
pine,<br />
Tsuga,<br />
Oregon pine<br />
Chestnut, Nara, beech<br />
Keyaki (Japanese oak)<br />
Oak<br />
Allowable stress for permanent<br />
stress kg. per sq. cm.<br />
Allowable stress for temporary<br />
stress kg. per sq. cm.<br />
Compression]<br />
[Tension<br />
or bending<br />
Shearing<br />
2 times the allowable<br />
stress for permanent<br />
stress<br />
v<br />
|2 However, hard wood of special good grade to be<br />
used as Shachi, pin, key, etc. its allowable stress<br />
may double the value in above table in the preceding<br />
paragraph respectively.<br />
|3 In foundation water tank, bath room, and others<br />
of the similar condition where it is always damp<br />
Angle between direction of grain and applied<br />
force<br />
1) In case of less than 10 deg.<br />
2) In case of above 10 deg. up to 70 deg.<br />
3) In case of above 70 deg. up to 90 deg.<br />
5 Allowable buckling stress of compression member<br />
shall, according to its effective slenderness<br />
ratio, be calculated by the following formula :<br />
or wet, its allowable stress shall be 70% of that<br />
of table in paragraph 1 respectively.<br />
4 Allowable bearing stress of needle leaf timber<br />
shall, depending upon the angle of direction of its<br />
grain to the applied force, be in accordance with<br />
the value given in the following table :<br />
Allowable bearing stress<br />
Same as compressive stress given in table of<br />
paragraph 1<br />
Value obtained by interpolation of the values of<br />
1) and 3) as straight line<br />
1/5 of allowable compressive stress given in the<br />
table of paragraph 1 (Connection or joint of<br />
sill and column or similar cases where no objectional<br />
deformation by bearing liable to occur,<br />
1/4)<br />
when a^ IOO fK=fc (1-0.007)<br />
when<br />
\> 1QO<br />
f K=<br />
0.3fc<br />
/X\2<br />
\-=^\ \:,100/<br />
-19-
fK stands for allowable buckling stress<br />
kg/cm2<br />
fc stands for allowable compressive<br />
stress in direction of grain<br />
x stands for effective slenderness ratio<br />
(Steel Member)<br />
Article 90. The value of allowable unit stress as<br />
of steel and iron shall be in accordance with the<br />
value given in the following table :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
2 Allowable unit stress for buckling shall be calculated according to effective slenderness ratio :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
(Concrete)<br />
Article 91. The value of allowable stress par sq. cm. of concrete shall be in accordance with the value<br />
given in the following table :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
(Welding)<br />
Article 92. Allowable unit stress of the weld through throat shall be in accordance with the value given<br />
in the following table;<br />
20-
ing the case of determining by loading test be<br />
less than the value obtained by calculation under<br />
the following formulas for different cases respectively:<br />
-21-<br />
<br />
<br />
<br />
<br />
<br />
(Soil and piles)<br />
Article 93. Allowable bearing power of soil, excepting the case of determining by loading test, the<br />
values in the following table shall be used :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
2 Regarding kind of soil not shown in the table of<br />
preceding paragraph shall be determined according<br />
to the similar type of soil respectively.<br />
3 Bearing power of foundation pole shall, except-<br />
I<br />
Method of driving of pile<br />
By drop hammer<br />
Single acting steam hammer<br />
Double acting steam hammer<br />
Allowable bearing power for<br />
permanent load<br />
w<br />
p__0.18W(H-HQ<br />
S-S' W+P<br />
,, 0.225W(H-HQ<br />
W+P<br />
0^25 (F - F_') W<br />
S-S' * W+P<br />
Allowable bearing power for<br />
temporary load<br />
2 times the allowable bearing<br />
power for permanent load<br />
R=Bearing power of pile in ton<br />
W=Weight of hammer in ton<br />
p=Weight of pile in ton<br />
H=Height, hammer dropped from in cm.<br />
F=In case of double acting steam hammer, the energy of impact in ton-cm.<br />
S=Amount of last penetration of pile in cm.<br />
H'=Height of drop corresponding to least amount of penetration S' of pile, striking after S has<br />
been measured, in cm.<br />
F;=The energy of impact corresponding to least amount c£ penetration S; of pile in case of double<br />
acting steam hammer, striking after S has been taken, in ton-cm.<br />
S;=Penetration of pile in case of height of drop H' or hammering energy F' in cm.
-22-<br />
Bection 9 Special Provisions for Structural<br />
Calculation<br />
(Application)<br />
Article 94. Structural calculation of buildings<br />
prescribed in Article 20 paragraph 2 of the Law<br />
may be done according to the provisions of this<br />
Section excepting the case under the provision of<br />
the preceding Section.<br />
(Principle of Structural Calculation)<br />
Article 95. For making structural calculation for<br />
building in accordance with the provisions of the<br />
preceding Article, it shall be exercised to check<br />
so that the stress at principal structural part<br />
caused by loads mentioned in the provisions of<br />
Article 98 and seismic force and other external<br />
forces mentioned in Article 97 shall not exceed<br />
respectively allowable unit stress prescribed in<br />
the provisions of Article 98.<br />
(Loads)<br />
Article 96. Values of dead loads applied to various<br />
parts of building shall be not less than those<br />
given in the following table :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
2 Values of live loads over floors of a building<br />
shall not be less than the values obtained by<br />
calculation according to the following table :
A<br />
8 Specially heavy loads on floor, irrespective of<br />
the values in above items, to be determined according<br />
to actual condition.<br />
4 Live load on floor of workshop and the like that<br />
support operating machinery with accompanying<br />
impact and vibration, etc. shall be increased by<br />
more than 1/4 of the values of each item in the<br />
table given in paragraph 2.<br />
5 Live loads figured in accordance with the provisions<br />
of the preceding three paragraphs may, according<br />
to actual condition, reduce the load not<br />
exceeding 1/10 for beams, 2/10 for girders, not<br />
more than the proportion given in the following<br />
table in consideration of number of stories supported<br />
for compression stress on column or footing,<br />
and the value corresponding to not more<br />
than, 5/10 for seismic force, excepting for theater,<br />
cinema, showhouse, place for viewing, auditorium,<br />
assembly hall, seatings or assembly room of a<br />
building available for other similar use, storage<br />
room (warehouse), book storage room, and others<br />
of similar class:<br />
<br />
<br />
i&<br />
6 Floors for garage, passageway for automobiles,<br />
workshop and the like supporting heavy concentrated<br />
load, its influence shall be taken into<br />
consideration in calculation.<br />
(Seismic Force)<br />
Article 97. Coefficient of horizontal force of earthquake<br />
taken shall be not less than 0.1. However,<br />
special local administrative agency may, by<br />
regulations, increase the coefficient of horizontal<br />
force applied to kind and district determined in<br />
respect to height of high building or chimney and<br />
other structures, or buildings and structures built<br />
on extremely un firm soil.<br />
(Allowable Unit Stress)<br />
Article 98. Allowable unit stress for structural<br />
materials used in buildings shall be in accordance<br />
with the values given in the following table.<br />
However, the unit stress for rolled steel with<br />
yielding point at 3500 kg/cm2 or more, or rivet<br />
steel with tensile strength at 5000 kg/cm2 or<br />
more may not be in accordance with this table:
3 Compression stress for concrete at age of 28<br />
days given in the preceding paragraph shall not<br />
exceed the value obtained by calculation under<br />
following formula, provided that the stress of<br />
concrete to be used is tested:<br />
F=K(0.85X~0.64)<br />
where F stands for compressive unit strength of<br />
concrete in kg/cm2 at age of 28 days<br />
K stands for unit compressive strength in<br />
kg/cm2 of mortar test piece at age of<br />
28 days by JES-R 5210 (portland cement)<br />
X stands for cement water ratio by weight<br />
4 The ratio of Young's modulus for steel to Young's<br />
modulus for concrete shall be taken at 15 for<br />
calculating stresses of reinforced concrete construction.<br />
5 Bearing power of pile drivenby use of a drop<br />
hammer shall not exceed the value obtained by<br />
the following formula :<br />
P=WH/(5D+0.1)<br />
where P=bsaring power in ton<br />
W=weight of hammer in ton<br />
H=height that hammer drops in meter<br />
D=penetration in meter by last blow of<br />
hammer<br />
(Methods of Estimating Spans for Beams for<br />
Calculation of Reinforced Concrete Construction)<br />
Article 99. Span for beams or slab in reinforced<br />
concrete construction shall be measured from<br />
center to center of its supports. However, the<br />
span may be replaced by the distance between<br />
the inside face of supports plus the depth of<br />
beam or the thickness of slab.<br />
2 Span for beam or slab with haunches at its ends<br />
may be taken at distance between the points in<br />
the haunches equal to 0.5 of the depth of beam<br />
or the thickness of slab measured up from the<br />
bottom of haunches.<br />
(Reinforced Concrete T-beam)<br />
Article 100. In case beams and slabs are built as<br />
monolithic, the construction may be considered as<br />
T-beam. In this case, calculation shall be made,<br />
taking the width of its flange less than 1/4 of its<br />
span and at the same time not more than 12<br />
times the thickness of the beam or slab.<br />
(Loads on Reinforced Concrete Slab in Roof and<br />
Floors)<br />
Article 101. In reinforced concrete construction<br />
where reinforcement bars in rectangular<br />
-24<br />
beam or slab supported on all its four sides run<br />
on bothways, the share of distributed load by<br />
both spans may be estimated within the limit<br />
not less than the values obtained by calculation<br />
under the following formulas :<br />
W&=l4W/(l4+b4)<br />
W;=b4W/(l4+ b4)<br />
where W=Load to be distributed per unit area<br />
1 =Span in one direction<br />
b =Span perpendicular to direction of 1<br />
Wj=Distributed load to be shared by slab<br />
with span 1<br />
W&=Distributed load to be shared by slab<br />
with span b<br />
(Sectional Area of Materials for Compression<br />
Member)<br />
Article 102. Load on compression members shall<br />
not exceed the values obtained by calculation<br />
under the following formulas according to composed<br />
members and their sections :<br />
For steel members : P=Afc(l-Cl/r)<br />
For timber : P==Afc(l-0.021/d)<br />
For reinforced concrete : P=fc(Ac+15As)<br />
where P=Load<br />
A=Sectional area<br />
fc=Allowable compression unit stress in<br />
provision of Article 98<br />
l=Distance between principal supports<br />
d=Least diameter of section<br />
r=Least radius of gyration; however, in<br />
steel column restrained in the direction<br />
of deflection by structural condition,<br />
r for corresponding axis in the<br />
direction of deflection may be chosen<br />
C=0.003 for steel member (0.004 when<br />
both ends are hinged), 0.005 for cast<br />
iron<br />
Ac=Effective area of concrete included<br />
within the circumferential line outside<br />
of its main reinforcement bars<br />
A5=Total sectional area of main bars<br />
2 When compression member of reinforced concrete<br />
construction has proper spiral hoopings,<br />
the compression unit stress for concrete mentioned<br />
in paragraph 1 may be increased by not<br />
exceeding 2/10 of its stress, provided that the<br />
pitch of hooping spiral is less than 8 cm.<br />
3 When the distance center to center of principal<br />
supports of compression member of reinforced
concrete construction for structural strength<br />
exceeds 15 times the least diameter of the<br />
member, it shall not be calculated by the<br />
formula in paragraph 1.<br />
(Section of Member for Bending)<br />
Article 103. Bending moment in number for bending<br />
shall not exceed the value obtained by calculation<br />
under the following formula :<br />
M=f&S<br />
where M-Bending moment#<br />
f& =Allowable bending stress in the provision<br />
of Article 98<br />
S =Section modulus<br />
(Section with Compression and Bending acted in<br />
Combination at the Same Time)<br />
Article 104. Combined unit stress resulting from<br />
compression stress and bending moment occurring<br />
at same time shall be calculated under the following<br />
formula :<br />
fc = (M/S) + (P/A) (l/(l-Cl/r))<br />
where fc =Combined unit compressive stress<br />
M=Bending moment<br />
S =Section modulus<br />
P =Compression force<br />
A =Section area<br />
1 =Distance between principal supports<br />
r =Radius of gyration about neutral axis<br />
of section due to bending moment.<br />
However, the lumber the diameter of<br />
section in bending moment, perpendicular<br />
to neutral axis<br />
C =0.003 for steel (0.004 in case its support<br />
is hinged), for cast iron 0.005,<br />
for lumber 0.02<br />
2 Combined stress for preceding paragraph shall<br />
not exceed the allowable unit stress as prescribed<br />
in the provision of Article 98.<br />
(Rectangular or T-beam Section)<br />
Article 105. Bending moment in reinforced concrete<br />
rectangular beam with single reinforcement,<br />
or single reinforced T-beam with its<br />
neutral axis located within the slab shall not<br />
exceed the values obtained by calculation under<br />
the following formulas :<br />
M=ni(3 - m) fcbd2/6<br />
M=(3-m) ffbd2/3m<br />
where M=Bending moment<br />
ni=Neutral axis ratio<br />
fc =Allowable unit compressive stress in<br />
concrete in the provision of Article 98<br />
ft =2Allowable unit tensile stress of steel<br />
bar in the provision of Article 98<br />
m=Percentage of steel to concrete in<br />
sectional area<br />
b =Width of beam<br />
d =Depth of beam<br />
2 Ratio of neutral axis in the provisions of preceding<br />
paragraph shall be calculated under the<br />
-25-<br />
following formula :<br />
15<br />
ni= (Vl+2m/15-l)<br />
where ni=Ratio of neutral axis<br />
m=Percentage of steel to concrete in<br />
sectional area<br />
(Reinforced Concrete Construction Member with<br />
Shearing Stress)<br />
Article 106. In section with main reinforcement<br />
bars crossing, of reinforced concrete column,<br />
beam or roof slab or floor slab, unit stress in<br />
shearing figured by the following formula shall<br />
not exceed 1/2 of compressive strength of<br />
concrete at age of 28 days, and at the same<br />
time, it shall be less than 18 kg. per sq. cm.:<br />
f, = S/bj<br />
where fs=Unit shearing for concrete<br />
S=Shearing force<br />
b=Width of beam or slab; however, for<br />
T-beam the width of stem<br />
j =Distance from center of compressive<br />
stress to center of tensile stress<br />
2 In case unit stress in shearing mentioned in<br />
the preceding paragraph exceeds the allowable<br />
unit shearing given in the provision of Article 98<br />
paragraph 2, stirrups or hoopings shall be placed<br />
in that part in accordance with the provisions of<br />
the following items. However, where main bars<br />
are bent up, that part may be considered as<br />
provided with sMrrups or hoops :<br />
(1) Stirrups and hoopings shall be arranged<br />
properly to take care of shearing stress distribution,<br />
and the spacing shall be less than 2/3<br />
of depth of column, beam or roof slab or floor<br />
slab;<br />
(2) Stirrups shall go around outside of tension<br />
bars and shall be carried into near the edge of<br />
compression side and also, they shall be<br />
anchored appropriately.<br />
CHAPTER IV Fireproof Construction, Fireresisting<br />
Construction, Firezone,<br />
etc.<br />
(Fireproof Construction)<br />
Article 107. By fireproof constructions prescribed<br />
in the provisions Article 2 item (7) of the law<br />
means as described by the following terms, excluding<br />
those that the grounds for finishing or<br />
covering part of steel skeleton with metal lath<br />
concrete, metal lath mortar, concrete mortar or<br />
plaster given in (c) of items (1) to (4) inclusive<br />
are those columns and beams given in item (2)<br />
(a) or (b) with least diameter or width less than<br />
25 cm. However, covering or thickness mentioned<br />
in item (1) (c) or item (2) (c) includes<br />
respectively the thickness of finish such as<br />
mortar plaster and the like.<br />
(1) Pertaining to walls that come under one of<br />
the following items :
(a) Reinforced concrete construction or steel<br />
frame reinforced concrete construction ;<br />
(b) In steel frame concrete construction, the<br />
thickness of concrete protective covering being<br />
3 cm. or more;<br />
(c) Steel frame construction with steel<br />
skeletons both sides of witch are covered<br />
with protective coat of reinforced concrete<br />
or mortar or metal lath of thickness 3 cm.<br />
or over or covered with bricks, stones or<br />
concrete blocks ;<br />
(d) In brick, stone or concrete block constructions<br />
reinforced by steel members, the<br />
thickness of brick, stone or concrete protective<br />
finish or covering being 4 cm. or more.<br />
(2) Pertaining to columns that come under one<br />
of the following items:<br />
(a) Reinforced concrete construction or steel<br />
reinforced concrete construction ;<br />
(b) In steel frame concrete construction, the<br />
thickness of protective covering of concrete<br />
being 5 cm. ormore;<br />
(c) Steel skeleton protected by bricks, stones<br />
or concrete blocks of thickness not less than<br />
7cm.;<br />
(d) Plain concrete, brick, stone or concrete<br />
block construction ;<br />
(e) In brick, stone or concrete block construction<br />
reinforced by steel members, the<br />
thickness of brick, stone or concrete block<br />
protective finish or covering being 7 cm. or<br />
more.<br />
(3) Pertaining to floors that come under one of<br />
the following items :<br />
(a) Reinforced concrete construction, or steel<br />
frame reinforced concrete construction ;<br />
(b) Plain concrete, brick, stone or concrete<br />
block construction of thickness being 3 cm.<br />
or more;<br />
(c) In brick, stone or concrete block construction<br />
of thickness 3 cm. or more reinforced<br />
by steel members, the thickness of<br />
brick, stone, or concrete block finish or<br />
covering being 4 cm. or more, or those steel<br />
materials being covered by mortar on metal<br />
lath or plaster of thickness 3 cm. or more.<br />
(4) Pertaining to beams that come under one<br />
of the following items :<br />
(a) Reinforced concrete construction or steel<br />
frame reinforced concrete construction ;<br />
(b) In steel frame concrete construction the<br />
covering of concrete for steel skeleton being<br />
5 cm. or more;<br />
(c) Steel truss without ceiling directly below<br />
or, in case there is ceiling directly, below,<br />
that ceiling is to be built of mortar on metaj<br />
lath not less than 2cm., or plaster, or wired<br />
(5) Pertaining to roofs that come under the<br />
following items :<br />
(a) Reinforced concrete construction or steel<br />
frame-reinforced concrete construction ;<br />
(b) Plain concrete, brick, stone or concrete<br />
block construction ;<br />
(c) Brick, or concrete block construction reinforced<br />
with steel members;<br />
(d) Metal lath concrete or mortar on metal<br />
lath with the thickness of covering 3 cm. or<br />
more or covered with wired glass.<br />
(6) Pertaining to stairs that come under one of<br />
the following items :<br />
(a) Reinforced concrete construction or steel<br />
frame reinforced concrete construction ;<br />
(b) Plain concrete, brick, stone^or concrete<br />
block construction ;<br />
(c) Brick, stone or concrete block construction<br />
reinforced with steel members ;<br />
(d) Steel construction.<br />
(7) In addition to those given in the preceding<br />
items, that designated by the Minister of Construction<br />
upon hearing the opinion of Director<br />
of National Fire Defence Agency as having<br />
fireproof quality equal to or better than above<br />
mentioned.<br />
2 In beams and columns in 2 topmost floors of a<br />
building or in a building less than 4 stories<br />
where steel frame construction is used, if the<br />
steel skeleton has non-combustible ground, and<br />
finished with protective covering of concrete or<br />
mortar on metal lath of thickness 5 cm. or more<br />
shall be treated as fireproof construction.<br />
(Fire-resisting Construction)<br />
Article 108. Meaning of fire-resisting construction<br />
mentioned in the provisions of Article 2 item (8)<br />
of the Law shall be as described in either one of<br />
the following items :<br />
(1) Mortar finish on metal lath or plaster finish<br />
on wood lath of thickness 2 cm. or more;<br />
(2) Mortar or plaster finish over wood-fibrecement<br />
sheet of total thickness 2.5 cm. or<br />
more;<br />
(3) Cement mortar coating with tile finish of<br />
total thickness 2.5 cm. or more;<br />
(4) Cement mortar finish over cement sheet,<br />
magnesia-cement sheet or common tiles of<br />
total thickness 2.5 cm. or more;<br />
(5) Dozo construction (Japanese earth-vault construction)<br />
;<br />
(6) Earth-plaster wall (shinkabe) construction<br />
with back coating ;<br />
(7) In addition to those mentioned in above<br />
items, that designated by the Minister of Construction<br />
upon hearing the opinion of Director<br />
of National Fire Defence Agency as having<br />
fire-resisting quality equal to or better than<br />
above mentioned.<br />
26
4<br />
2 Exterior walls in one story building with framing<br />
constructed of non-combustible materials<br />
surface of which is applied with wood-fibercement<br />
sheet of thickness 1.5 cm. or more, or<br />
fire-protecting timber of thickness 0.9 cm. or<br />
more to receive the finishing of sheet metal shall<br />
be treated as fire-resisting construction.<br />
(Fire-door and Other Fire Protective Facilities)<br />
Article 109. By fire-door and other fire protective<br />
facilities mentioned in the provisions of Article<br />
64 of the Law shall mean any one of the items<br />
as described below :<br />
(1) Fire door A;<br />
(2) Fire door B;<br />
(3) Drencher installed in opening which has<br />
passed the inspection to be conducted by the<br />
National Fire Defence Agency.<br />
2 Fireproof- or fire-resisting exterior wall, wing wall<br />
and other similar construction that built cutting<br />
across an opening in a building or buildings and<br />
all parts of boundary line, center line of road<br />
and center line of exterior wall of each building<br />
constituting more than 2 houses within the same lot<br />
(building with total floor area less than 500 sq. m.<br />
considered as one house) located or separated at<br />
the distance 3 m. or less from the opening concerned<br />
in case of one story and 5 m., or less in<br />
2nd floor or above to the above mentioned center<br />
lines, shall be considered as the fire-facilities<br />
mentioned in the preceding paragraph.<br />
3 In ventilation opening of area 100 sq. cm. or<br />
less, the fire-resisting protection made of iron<br />
plate, mortar slab and other similar materials<br />
(including vent located in part 1 m. less from<br />
ground level protected by metal wire net of<br />
2 mm. mesh.) shall be considered as the firefacilities<br />
mentioned in paragraph 1.<br />
(Construction of Fire-door)<br />
Article 110. Fire door A mentioned in the preceding<br />
Article paragraph 1 item (1) shall mean one<br />
of the constructions describad in one.of the<br />
following items :<br />
(1) Frame shall be steel with steel plate of<br />
thickness 0.5 mm. or more applied on all faces;<br />
(2) Made of steel, with steel plate of thickness<br />
1.5 mm.or more;<br />
(3) Made of steel frame concrete or of reinforced<br />
concrete of thickness 3.5 cm. or more;<br />
(4) Door of dozo-construction *of thickness 15<br />
cm. or more;<br />
(5) That specified as having equal or superior<br />
fire-resisting quality by the Minister of Construction<br />
upon hearing the opinion of the<br />
Director of National Fire Defence Agency in<br />
addition to those given in the foregoing items.<br />
2 Fire-door B mentioned in the preceding Article<br />
paragraph 1 item (2) shall satisfy one of the<br />
following requirements in its construction :<br />
(1) Made of steel plate of thickness less than<br />
-27-<br />
1.5 mm.;<br />
(2) Made of steel frame concrete or reinforced<br />
concrete of thickness less than 3.5cm. ;<br />
(3) Door of dozo-construction of thickness less<br />
than 15 cm.;<br />
(4) Steel construction with wired glass inserted;<br />
(5) Fire-protecting timber frame with galvanized<br />
sheet iron applied on all faces;<br />
(6) Fire-protecting timber frame with interior<br />
faces applied with fire-protecting timber board<br />
of thickness 0.9 cm. or more, and its exterior<br />
face protected by application of galvanized<br />
iron sheet ;<br />
(7) That recognized as having equal or superior<br />
fire-resisting quality by the Minister of Construction<br />
upon hearing the opinion of the<br />
Director of National Fire Defence Agency and,<br />
in addition to those given in the foregoing<br />
items.<br />
3 Door for opening of 500sq.cm. or less in area<br />
made of fire-protecting timber frame insertion of<br />
wired-glass shall be considered as fire-door B in<br />
the preceding paragraph.<br />
4 The part of fire door coming in contact with<br />
frame or other fire door shall be of tongue and<br />
groove fit, or of, "jogibuchi" or door stop, so it<br />
shall be intact in place in case of fire, and shall<br />
be so installed that the hardware building fire<br />
door will not show where closed.<br />
5 Fire door mentioned in paragraph 1 item (1) or<br />
item (2), or paragraph 2 item (1) or item (4)<br />
shall be installed in opening where surrounding<br />
of opening (in case fixture is to be installed<br />
within 15cm. inside of fire door, that fixture<br />
shall be included) is constructed of non-combustible<br />
materials or fire-protecting timber.<br />
(Principal Important Materials for Fire Prevention)<br />
Article 111. Cement,metal lath, wire lath, wood-firecement<br />
sheet, fire-protecting timber, fire-protecting<br />
point, or other principal fire-resisting materials<br />
similar to them to be used in structural parts in<br />
addition to the principal parts of construction on<br />
the structural parts of fire-proof construction and<br />
fire-resisting construction or fire doors.<br />
(Fire-preventing Section)<br />
Article 112. Building that its principal part of<br />
construction is constructed of fireproof or noncombustible<br />
materials, and its floor area exceeding<br />
1500 sq. m. there shall be provided with fire<br />
fighting section at convenient part so that total<br />
floor area of part included in that section shall<br />
not exceed 1500 sq. m., and constituting either<br />
floor or wall of fireproof construction, or with<br />
fire door A. However, in the case of a part of<br />
building provided with sprinkler or in the indispensable<br />
case due to its use, such as seating<br />
room, theater, cinema, show house, place of review,<br />
auditorium or assembly hall, indoor sport
oom, factory or others of the similar cases shall<br />
be expected.<br />
2 In case apart of building coming under one of the<br />
items of Article 24 paragraph 1 of the Law that<br />
part and other parts shall be separated by wall<br />
made of fireproof construction or by wall with<br />
both faces made as fire-resisting construction, or<br />
provided with fire door A or fire door B (excluding<br />
the type mentioned in Article 110 paragraph<br />
2 item (3) and item (6). ><br />
3 In case a part of building coming under one of<br />
the items of Article 27 of the Law that part and<br />
other parts shall be separated by floor or wall<br />
made of fireproof construction and fire door A.<br />
(Fire Wall in Wooden Buildings, etc.)<br />
Article 113. Fire wall shall be constructed as required<br />
by the following items :<br />
(1) Self supporting structure of fireproof construction<br />
;<br />
(2) In wooden building, neither concrete construction<br />
nor masonry construction shall be<br />
allowed ;<br />
(3) Both ends and top of fire wall shall project<br />
out from exterior walls and roof not less than<br />
50cm. (in case exterior wall of a building<br />
located on both sides of fire wall and underneath<br />
of eave or ground for roof for distance<br />
of 1.8 m. or less are of fire-resisting construction,<br />
and at the same time there is no opening<br />
in the parts mentioned herein, that projecting<br />
part may be 10cm.). However, in case fireproof<br />
exterior wall or roof is of fire-resisting<br />
construction located at section of width 3.6 m.<br />
or more including fire wall, and at the same<br />
time there is no opening or the opening in that<br />
part is provided with fire door or sash window<br />
made of fire protecting timber with insertion<br />
of wired-glass is installed, that part shall be<br />
excepted ;<br />
(4) Opening in fire wall shall be less than 2.5<br />
m.sq. and it shall be provided with fire door A;<br />
(5) Space between fire wall and passing water<br />
pipe, electric wire conduct and other pipes shall<br />
be filled with mortar,<br />
(Principal Partition Wall, etc. for Building)<br />
Article 114. Partition wall between each unit of<br />
multifamily tenant housing or apartment house<br />
shall be built as fireproof or fire-resisting construction,<br />
and it shall be carried up to roof truss<br />
or ceiling space.<br />
2 Principal partitionwall in the part of a building<br />
used as school, hospital, medical office, (excluding<br />
those having no facilities for accommodation<br />
of patients), hotel, Japanese hotel, lodging house,<br />
dormitory or market as concerned in the matter,<br />
shall be built as fireproof or fire resisting con-<br />
-28-<br />
struction, and shall be carried up to roof truss or<br />
ceiling space.<br />
B When roof trusses of a building exceeding 300<br />
sq.m. in its building area are constructed of<br />
wood, a partition wall with its both sides built<br />
of fire-resisting construction shall be provided in<br />
roof truss space at points not exceeding 12 m.<br />
measured along the side wall girder.<br />
4 Passageway connecting two buildings of total<br />
floor area exceeding 200 sq. m., and of length 4m.<br />
or more with wooden trusses shall be provided<br />
with partition in roof truss space built of fireproof<br />
construction or fire-resisting construction<br />
on both faces.<br />
(Chimney built within Building)<br />
Article 115. Chimney built within building shall<br />
satisfy the structural requirements as described<br />
in the following items :<br />
(1) Vertical distance of projection of chimney<br />
built within a building to the face of roof shall<br />
not be less than 60cm.; however, in case of<br />
brick, stone or concrete block construction built<br />
without reinforcing steel members, the part<br />
projected up shall be not less than 90 cm;<br />
(2) In case there is a building at horizontal<br />
distance less than 1 meter from the top of a<br />
chimney, the chimney shall be carried up 60cm.<br />
or more above the eave of a building concerned;<br />
(3) Part of chimney built of metal or asbestos,<br />
going through roof truss space, ceiling space,<br />
floor space, etc., shall be covered with incombustible<br />
materials other than metal ;<br />
(4) Metal or asbestos chimney shall be built at<br />
least 15 cm. away from wooden or other combustible<br />
material, excepting that part covered<br />
with incombustible materials other than metals<br />
of thickness 10 cm. or more;<br />
(5) Part of chimney of fireplace built in with<br />
wall in a building that is in interior of house<br />
shall be constructed of reinforced concrete of<br />
thickness 15cm. or more, or plain concrete<br />
brick, stone or concrete block construction of<br />
thickness 25cm. or more, and in brick, stone<br />
or concrete block chimney shall be lined with<br />
earthenware pipes or with finish of cement<br />
mortar ;<br />
(6) In the case of fireplace built in with wall<br />
where bend is less than 120°, there shall be an<br />
opening at the bend ifor cleaning.<br />
(Quantity of Dangerous Materials)<br />
Article 116. Quantity of dangerous materials mentioned<br />
in Article 27 item (6) of the Law is as<br />
listed below :
29-
2 In case of temporary uses for engineering works<br />
and other enterprises, the limit of the quantity<br />
of dangerous materials permitted to.b#e stored<br />
for the purpose of carrying out the work, andthe<br />
limit of quantity of compressed gas or liquified<br />
gas of combustion-resisting or incombustible<br />
quality shall be unrestricted.<br />
3 In case more than two kinds of the dangerous<br />
materials given in the table of paragraph 1 are<br />
to be stored in the one building, the limit of the<br />
dangerous materials prescribed by paragraph 1<br />
shall be obtained by dividing the volume of<br />
quantity of dangerous material intended to be<br />
stored by the built of the value of the quantity<br />
of dangerous material in the column concerned,<br />
and the case the value of sum respective quotients<br />
istobe 1.<br />
30-<br />
CHAPTER V Facilities for Escape<br />
Section 1 Corridor, Escape Stairways and<br />
Exits<br />
(Scope of Application)<br />
Article 117. The provisions of this Section shall<br />
apply to special buildings mentioned in Article 35<br />
of the Law or to a building with total floor area<br />
of living rooms exceeding 1,000 sq. m. However,<br />
as to part partitioned fire-proof walls without any<br />
opening for living room with total area less than<br />
1,000 sq.m. which shall not be used as special<br />
building enumerated in said Article, they shall<br />
not apply.<br />
(Door in Exits to Audierxa Hall)<br />
Article 118. Doors installed in exits of audience<br />
hall of theatre, cinema, show house, place for<br />
viewing, or auditorium or assembly hall shall not<br />
be installed to open in.<br />
(Width of Corridor or Passageways)<br />
Article 119. Width of corridor or passageways<br />
shall be wider than the figures given in the<br />
following table :
(Distance by Walk to Stairways)<br />
Article 120. In floors other than escape-floor (floor<br />
with exits directly leading to ground, hereinafter<br />
, the same) of a building, a distance by walk from<br />
each part of living room to one of through stair<br />
ways leading directly to escape floor (including<br />
ramp; hereinafter the same) shall not exceed<br />
the values given in the following table :<br />
>s^<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
V<br />
(Providing Through Stairways and its Structure)<br />
Article 121. In case floors other than escape-floor<br />
of a building come under one of the following<br />
items, more than two through stairways beading<br />
from that story to escape-floor shall be provided.<br />
However, of those mentioned in from item (2) to<br />
item(4) inclusive, if its principal structural parts<br />
are constructed as fire-proof structure or constructed<br />
of incombustible materials, the provision<br />
of item 5 shall govern:<br />
(1) Use for theater, cinema, show house, place<br />
of viewing, auditorium, or department store or<br />
meeting place ;<br />
(2) Of floors for use as hospital or medical office,<br />
the floor in which the total floor area for<br />
patients use exceeds more than 50 sq.m.;<br />
(3) Of floors for use as hotel, Japanese hotel or<br />
lodging house, the floor in which the total floor<br />
area of bed room for guest is 100sq.m.; or of<br />
floors for use as apartment houss, the floor in<br />
which the total floor area of living room exceed<br />
100sq.m.; or of floors for use as dormitory,<br />
the floor in which the total floor area for sleeping<br />
rooms exceeds 100 sq.rn. or more;<br />
(4) Of floors other than those mentioned in<br />
preceding two items, floor in which the total<br />
31<br />
floor area of living rooms directly above or<br />
directly below escape-floor exceeds 200 sq. m.<br />
and of other floors, the floor in which total area<br />
floor exceed 100 sq. ;<br />
(5) Of floors of a building with its principal<br />
structural parts built as fireproof construction<br />
or with incombustible materials, the floor in<br />
which the total floor area of living rooms<br />
exceeds 400 sq. m.<br />
2 In case a building is divided into sections by<br />
means of fireproof partitions without any opening<br />
the provisions of preceding paragraphs shall apply<br />
to the respective sections.<br />
3 Through stairways under the provisions of paragraph<br />
1 that are provided outside, shall not be of<br />
wooden construction.<br />
(Providing Escape Stairways)<br />
Article 122. Through stairways leading to 5th floor<br />
or above in a building of 5 floors or more above<br />
ground level shall be escape stairways or special<br />
escape stairways in accordance with the provision<br />
of Article 123.<br />
2 In a building for use asdepartment store coming<br />
under the provisions of Article 27 item (4) of the<br />
Law, two or more through stairways shall ba<br />
provided leading to and from sales rooms of each
floor and open space in roof and they snail become<br />
escape-stairways or special escape stairways<br />
prescribed in Article 123.<br />
3 One of through stairways mentioned in the<br />
preceding paragraph that lead to or from sales<br />
room of 5th floor and above shall be special<br />
escape stairs prescribed in Article 123 paragraph<br />
3.<br />
4 In a part of a building above 5th floor used as<br />
department store with total floor area exceeding<br />
3,000sq.m. special escape stairs prescribed in<br />
Article 123 paragraph 3 one for every 3,000sq.m.<br />
of floor area shall be provided which will not<br />
serv6 for 4th floor and floors below 4th.<br />
(Structure of Escape and Special Escape Stairways)<br />
Article 123. Escape stairways to be installed inside<br />
a building shall be built in accordance with<br />
the construction described in the following items.<br />
However, for top floor, the provisions of item(l),<br />
item (3) or item (4) may not apply:<br />
(1) Stair-case shall be surrounded with fireproof<br />
walls excepting the part in direct contact with<br />
outside air part of the windows of item (3) or<br />
the exits of item (4) ;<br />
(2) Windows and other effective opening for<br />
taking in light or the illumination equipment<br />
with supplementary electric supply shall be<br />
* provided in staircase;<br />
(3) In case windows are to be provided inwalls<br />
of staircase facing inside house, area of each<br />
windows shall be less than 1 sq. m., and fixed<br />
steel sash window with wired glass shall be<br />
installed therein ;<br />
(4) Exits to stairways from inside of house shall<br />
be provided with automatic closing fire door A<br />
or steel door with wired glass which may be<br />
opened in case of necessity;<br />
(5) Door or its auxiliary exit door mentioned in<br />
the preceding item shall be installed to open<br />
toward direction of escaping;<br />
(6) Stairways shall be of fireproof construction,<br />
and it shall lead directly to escape-floor.<br />
2 Escape stairways to be provided outside of a<br />
house shall be constructed as required by the<br />
following items; however, as for top, provisions<br />
of item (1) or item (2) may not apply:<br />
(1) Stairways shall be provided at distance 2 m.<br />
or more away from the opening (excluding an<br />
opening 1 sq.m. or less in area with fixed steel<br />
sash window with wired glass in) other than<br />
the exit leading to those stairways from inside<br />
of house;<br />
(2) Exits for stairways connecting to or from<br />
inside of house shall be provided with automatic<br />
fire-door A or steel sash door with wired glass<br />
which may be operated at any time;<br />
(3) Door or auxiliary exit door in it mentioned<br />
in the preceding item shall be installed to open<br />
-32<br />
to direction of escaping ;<br />
(4) Stairways shall be of fireproof construction<br />
which shall lead directly to ground level.<br />
3 Special escape stairways shall be constructed in<br />
accordance with the requirements of the following<br />
items; however, as for top, provisions of item<br />
(1) item (2), item (4) or item (5) may not<br />
apply:<br />
(1) Either balcony or attached room with<br />
window open to outside air shall be provided,<br />
between inside of the house and stair-casa;<br />
(2) Excluding part of opening directly in contact<br />
with outside air or part of window of item (5),<br />
part in exits of item (7) or item (8), stair-case<br />
and attached room shall be surrounded by fireproof<br />
wall ;<br />
(3) Stair-case shall be provided with window<br />
facing attached room and other effective opening<br />
for taking in light or shall be installed illuminating<br />
equipment with extra source of<br />
electricity ;<br />
(4) Stair-case shall not be provided with opening<br />
*facing inside house except at parts facing<br />
balcony and attached room ;<br />
(5) In case window is provided in apart facing<br />
balcony or attached room of stair-case, sash<br />
window shall be fixed;<br />
(6) In balcony and attached room, no opening<br />
except exit in walls facing inside of the houss<br />
outside of stair-case shall be provided;<br />
(7) Exit leading from inside house to balcony<br />
or attached room shall be installed with automatic<br />
fire door A tjaat may be operated at any<br />
time;<br />
(8) Exit leading from balcony or attached room<br />
to staircase shall be provided with automatic<br />
door that may be operated at any time;<br />
(9) Door or its auxiliary door mentioned inthe<br />
preceding two items shall be so installed as to<br />
open to direction of escaping;<br />
(10) Stairways shall be constructed as fireproof<br />
and shall lead directly to escape floor.<br />
(Width of Escape Stairways, etc. in Department<br />
Store)<br />
Article 124. With respect to the escape stairs,<br />
special escape stairs and width of exits leading<br />
to these in a building used as department store,<br />
the requirements of the following items shall be<br />
observed :<br />
(1) Total of the widths of escape stairways and<br />
special escape stairways in each floor shall be<br />
not less than the values obtained by calculating<br />
by the following proportion in floors above<br />
ground level 6cm. per 100sq. m. of total floor<br />
area (part of floor used for department store,<br />
hereinafter the same in this Article and Article<br />
125) of each floor directly above that floor from<br />
which one is to take refuge by means of that<br />
escape stairways and special escape stairways
and at the same time more than 30cm. per<br />
100 sq. m. of floor area of that floor;<br />
(2) Total of widths of exits leading to or from<br />
escape stairs and special escape stairs in each<br />
floor shall be more than the values obtained by<br />
calculating by the following proportions per 100<br />
sq.m. of that floor in each floor: more than<br />
27 cm. in floors above ground level, more than<br />
36 cm. in ground floor.<br />
2 Regarding calculation of the required widths<br />
mentioned in the provisions of the preceding<br />
items, escape stairs and special escape stairways<br />
chiefly leading to escape-floor from one floor or<br />
two floors above ground level may be considered<br />
as those having the width of 1.5 times.<br />
3 In applying the provisions of tha preceding two<br />
paragraphs, open space in roof shall be considered<br />
same as other floors.<br />
(Exits to Outside of Building)<br />
Article 125. In escape-floor the walking distance<br />
leading from stairways to one of the exits to<br />
outside of a building shall be less than the value<br />
given in the provisions of Article 120.<br />
2 Doors in exits leading to outside of a building<br />
for use of audiences in theater, cinema, showhouse,<br />
place of viewing, or auditorium, or meeting<br />
place shall not be installed to open in.<br />
3 Total of widths of exits in escape-floor of department<br />
store leading to outside shall be more than<br />
the values obtained by calculation under the<br />
following proportion; 6 cm. per 100 sq. m. or<br />
total floor area of each floor, and at the same<br />
time more than 40cm. per 100 sq.m. in floor<br />
area of largest floor.<br />
4 The provisions of paragraph 3 of the preceding<br />
Article shall apply to the preceding paragraph<br />
mutatis<br />
mutandis.<br />
(Open Space in Roof)<br />
Article 126. Open space in roof shall be surrounded<br />
by parapet wall or wire fence of height 1.1 meters<br />
or more necessary for safety.<br />
2 In case the floors above 5th floor of a building<br />
are to be used as sales rooms of department<br />
store, an open space in roof available for refuge<br />
shall be provided.<br />
Section 2 Passages within Building Site<br />
Necessary for Escape and Defence<br />
against Fire<br />
(Scope of Application)<br />
Article 127. The provisions of this section shall<br />
aor-ly to the buildings mentioned in Article 35 of<br />
the Law.<br />
(Passageways within Building Site)<br />
Article 128. Building site shall be provided with<br />
passageways 1.5m. or more in width leading from<br />
outside escape stairways mentioned in Article 123<br />
paragraph 2, and with exits mentioned in Article<br />
-33-<br />
125 paragraph 1 to road, park, open space and<br />
other large vacant spaces.<br />
(Passageway in Site for large Scale Wooden<br />
Building) *-<br />
Article 129. If-a building with whole of its principal<br />
structural parts is constructed of wood and<br />
exceeding 1,000sq.m. in total floor* area or a<br />
part of principal structural part is wood construction<br />
when its total floor area (excluding<br />
floor area of the part, for which principal structural<br />
parts are fireproof and separated from other<br />
parts by means of fireproof walls and fire doors<br />
A if any; hereinafter the same in this Article)<br />
exceed 1,000 sq. m., it shall be surrounded by<br />
passage 3 m. wide or more (except the part<br />
bounded by a road). However, in- case the total<br />
floor area is less than 3,000 sq. m., the width of<br />
passageway along the boundary line of adjacent<br />
lot may be 1.5m. or more.<br />
2 In case there is a building composed of more<br />
than 2 houses or more in the same building site<br />
(excluding a building with its principal structural<br />
parts are either built or are of fireproof construction<br />
or with incombustible materials, and those<br />
with floor area exceeding 1,000 sq.m.), if its<br />
sum of total floor area exceeds 1,000 sq. m., the<br />
part constituting the total of total floor area over<br />
in 1,000 sq.m. shall be divided into section of<br />
building with total floor area kept within 1,000<br />
sq. m. and shall be surrounded by passageways 3<br />
m.or more in width (excluding parts bounded by<br />
road or boundary lines of adjacent lots.)<br />
B The exterior wall (if there are eaves, including<br />
underneath thereof) of fireproof construction and<br />
having fire floor at an opening liable to fire<br />
spread, if it is cut away effectively against fire<br />
door by means of buildings with total floor area<br />
kept within 1,000 sq. m. the provision of the<br />
preceding paragraph shall not apply to these<br />
buildings. However, in case the total of total<br />
floor of the building exceeds 3,000sq. m., the part<br />
constituting the total of that total floor area not<br />
exceeding 3,000 sq. m. shall be surrounded by<br />
passage (excluding the parts bounded by roads or<br />
boundary lines of adjacent lots) 3m. or more in<br />
width.<br />
4 Irrespective of the provisions of the preceding<br />
items, passageway may go through the corridor<br />
coming under the provisions of the following<br />
items. However, the passageway out through<br />
the corridor shall be more than 2.5m. in width<br />
and height :<br />
(1) Width not over 3 meters;<br />
(2) Not to be used except for passage or light<br />
transport.<br />
5 Passageways mentioned in each preceding paragraph<br />
shall lead and reach to the roads on which<br />
abuts the building site,
CHAPTER VI Use Zone<br />
(Moderation of Restrictions for Existing Buildings)<br />
Article 130. Permissible scope of enlargement, remodelling<br />
or change of usa of existing buildings<br />
not complying with provisions of Article 49 of the<br />
Law or Article 50 paragraph 2 or paragraph 4 of<br />
the Law shall be as provided for in. the following<br />
items with the standard at the time when the<br />
building concerned has come not to comply with<br />
these provisions (hereinafter referred to as<br />
"standardized time" in this Article) :<br />
(1) The enlargement or remodelling is to be<br />
done in the site at standardized time, and the<br />
area or total area of building for enlargement<br />
or remodelling is not to exceed the percentage<br />
against area of site at standardized time prescribed<br />
in the provisions respectively in Article<br />
55 of the Law or Article 56 of the Law;<br />
(2) After standardized time total floor area to<br />
be increased by extension (in case extension<br />
involves more than two houses or enlargement<br />
undergoes by several extension works, total of<br />
floor areas increased by these enlargement works)<br />
shall not exceed 1/2 of total floor at standardized<br />
time (in case there is a building constituting<br />
more than two houses in the same site, tota1<br />
floor area thereof) ;<br />
(3) Total floor area of part of a building (total<br />
of floor areas increased by these enlargement<br />
of change of use when several extensions or<br />
change of use take place) not appropriate for<br />
uses mentioned in the provisions of Article 49<br />
of the Law or Article 50 paragraph 2 or paragraph<br />
4 of the Law concerned with the increase<br />
through enlargement or change of use after<br />
standardized time shall not exceed 1/2 of the<br />
total of that floor area at standardized time;<br />
(4) In the case where the cause not complying<br />
with the provisions of Article 49 of the Law is<br />
due to horse power of motors or number of<br />
machineries, the total of horse power of motors<br />
or number of machineries increased by enlargement<br />
of building or change thereof after standardized<br />
time (in case enlargements take place<br />
at several occasions, the total of these enlargements)<br />
shall not exceed 1/2 of total of horse<br />
power or number of machineries at standardized<br />
time.<br />
CHAPTER VII Height of Building<br />
(Disposal about Moderation in Height)<br />
Article 131. Disposal about moderation of application<br />
of the provisions of Article 58 paragraph 1<br />
or paragraph 2 of the Law under the provisions<br />
of paragraph 3 of the same Article shall be as<br />
prescribed in this Chapter.<br />
2 In the case of area where land replotting has<br />
been executed as well as other areas where<br />
street blocks have been readjusted In like manner,<br />
the road on which abut the street blocks, subject<br />
to the designation of administrative agency concerned<br />
shall be treated as the front road.<br />
(In case of having more than two Front Roads)<br />
Article 132. In case more than two front roads to<br />
a building exist, regarding the area with horizontal<br />
distance from the boundary line of front road<br />
which is largest within the limit of twice the<br />
width of that road, or at the same time with the<br />
-distance within the limit of 35 and regarding the<br />
area with the horizontal distances from center<br />
line of other front roads exceeding 10m., the<br />
width of all front roads shall be treated as having<br />
the same width as the widest front road.<br />
2 With regard, out of the areas other than that<br />
mentioned in the preceding paragraph, to the<br />
area with horizontal distance from the boundary<br />
line of one front road within the limit of twice<br />
the width of that road and at the same time<br />
with the distance within the limit of 35m., the<br />
front road thereof only may be considered as the<br />
front road.<br />
3 With regard, out of the areas other than that<br />
mentioned in paragraph 1, to the area with<br />
horizontal distance from the boundary line of<br />
more than two roads within the limit of twice<br />
the widthof each road and at the same time<br />
with the distance within the limit of 35m., the<br />
narrowest road of the front roads thereof shall<br />
be considered as having the same width of the<br />
wider road.<br />
(When Site abuts on Park, Open Space, Body of<br />
Water, etc.)<br />
Article 133. In case a site of a building abuts on<br />
park, open space, body of water, or others of the<br />
similar nature, the height of each and all part of<br />
said building may be taken 1.5 times or less<br />
(1.25 times in residential zone) of the horizontal<br />
distance measured from the boundary line of the<br />
opposite side of the front road, and at the same<br />
time, it shall not exceed twice the width of front<br />
road (1.75 times in residential zone) increased<br />
by 8m., and it shall not exceed the width of said<br />
park, open space, body of water, or others of the<br />
same or similar nature.<br />
(In case Park, Open Space, Body of Water or the<br />
Like exists on the Opposite Side of Front Road)<br />
Article 134. In case park, open space, body of<br />
water or the like exists on the opposite side of<br />
front road, the height at any and all parts of said<br />
building shall be less than 1.5 times of the<br />
horizontal distance from that part or parts of<br />
building to the boundary line on opposite side of<br />
said park, open space, body of water or the like<br />
(1.25 times in residential zone), and at the same<br />
time, it does not exceed twice the width of front<br />
road (1.75 times in residential zone) plus 8 m.<br />
OA<br />
^^O*±<br />
*"""•E
(In Cass there is Wall-surface Line Designated in<br />
Opposite Site of Front Road)<br />
Article 135. In case there is wall-surface line<br />
receded front road boundary line is opposite front<br />
road, the height of each part of that building<br />
shall be 1.5 times (in residential zone 1.25 times)<br />
the distance measured horizontally from that<br />
part to that wall line, or less, and at the same<br />
time it shall not exceed the width equal to or<br />
less than 1.5 times the width of front road (1.25<br />
times in residential zone) plus 8 m.<br />
(In Case Level of Road and Building Site not at<br />
Same Height)<br />
Article 136. In case the level of building site is<br />
higher than front road by 1 m. or more, the front<br />
road shall be considered to exist at tbe level<br />
equal to 1/2 or the difference of levels or the<br />
ground and building sites and the front road<br />
minus one meter.<br />
2 In case the administrative agency concerned<br />
deems it extremely improper to apply the pro*<br />
cedures as prescribed in the provisions of the<br />
preceding paragraph by reason of the special<br />
character of feature of land, irrespective of the<br />
provisions of said paragraph, the height of the<br />
position of that road may, by regulation, be<br />
determined as deemed proper so long as the<br />
height is kept within the level of ground at the<br />
position and site prescribed by the provisions of<br />
the same paragraph.<br />
CHAPTER VIII Miscellaneous Provisions<br />
!<br />
(Similarity of Uses)<br />
Article 137. The mutual relation of similar uses<br />
as provided for in the proviso to Article 87 paragraph<br />
2 of the Law shall, in case of existing<br />
building, mean the mutuality of uses belonging to<br />
the same item in the following items:<br />
(1) Theater, cinema, show house, auditorium,<br />
meating place ;<br />
(2) Department store, market;<br />
(3) Hotel, Ryokan (Japanese hotel) ;<br />
(4) Apartment house, dormitory, lodging house,<br />
hospital, medical office (excepting that which<br />
has no accommodating facilities for patients).<br />
Regarding the application of the provisions of<br />
Article 49 of the Law or Article 50 paragraph 2<br />
or paragraph 4^ of the Law, irrespective of the<br />
preceding paragraph, and in the case of existing<br />
building, mean the mutual uses of the same item<br />
of each item (if there is any item separated by<br />
parenthesis within the item, meant by that item ;<br />
in paragraph (c) item 1 item (1), item (2), item<br />
(3), item (4) and item (12) where it says "manufacture"<br />
shall also include disposal as well as of<br />
annexed Table No. 1 of the Law (excluding parts<br />
concerning articles or things of paragraph (A)<br />
item 1 paragraph (B) item (1) and paragraph (C)<br />
item 2 item (1), item (2), item (3), item (4) and<br />
-35-<br />
i<br />
item (12)) and the each item of annexed Table<br />
No. 2 of the Law.<br />
3 Regarding the designation of similarity of uses<br />
provided for in the proviso to the same paragraph<br />
in case of applying mutatis mutandis of the<br />
provisions of the by-law given in the same paragraph<br />
in accordance with the provisions of Article<br />
87 paragraph 2 of the Law irrespective of the<br />
provision of paragraph 1, separate provision may<br />
be made by the same by-law.<br />
(Designation of Structures)<br />
Article 138. In accordance with the provisions of<br />
Article 88 paragraph 1 of tfie Law, the following<br />
items of structures (excluding those concerning<br />
operation, safety, etc., within the site of railway<br />
and tramway shall be designated :<br />
(1) Chimney exceeding 6m. in height (in case<br />
there is frame for support or stay lines, the<br />
same included and the stove-chimney excluded) ;<br />
(2) Reinforced concrete column, steel column,<br />
wooden column exceeding 15m. in height or<br />
other similar ones (excluding flag pole and<br />
transmission poles for electricity) ;<br />
(3) Advertisement tower, advertisement boanjn<br />
decoration tower, memorial tower, and other<br />
similar structures ;<br />
(4) Wooden elevated tank, silo and watch tower<br />
exceeding 8m. in height or other similar<br />
structures ;<br />
(5) Retaining walls exceeding 2m. in height,<br />
(Chimney and Stays at Chimney)<br />
Article 139. Regarding the chimney given in paragraph<br />
1 item (1), of the preceding Article in<br />
addition to applying mutatis mutandis the provisions<br />
of Article 36, Article 37, Article 40, Article<br />
41, Article 47, Article 51 paragraph 1, Article 52,<br />
Article 53, Section 5? Section 6 (excluding Article<br />
76 to Article 78 inclusive) and Section 7 (Article<br />
51 paragraph 1, Article 53, Article 71, Article 72,<br />
Article 74 and parts applying mutatis mutandis of<br />
Article 75 only) the following items shall apply<br />
respectively according to the structural requirement:<br />
(1) Chimney constructed of terra cotta pipes,<br />
concrete pipes or pipes of similar make shall<br />
use mortar with cement at each connection or<br />
joint, and it shall be tied firmly to the supporting<br />
frame, or supporting frame and stay wires.<br />
However, those exceeding 10 m. in height shall<br />
be built of self-supporting frames ;<br />
(2) Chimney of masonry construction shall be<br />
provided with steel frame to prevent it from<br />
falling down;<br />
(3) In reinforced concrete chimney, the thickness<br />
of concrete cover over steel bars shall be<br />
more than 5cm;<br />
(4) Chimney exceeding 16m. in height shall be<br />
of reinforced concrete construction which requires<br />
no stay wires.
2 Stay wires of achimney shall be fixed to areinforced<br />
concrete pile or to a building or structure<br />
free from getting rot or to a wooden pile treated<br />
with creosote or the like.<br />
(Reinforced Concrete Columns, etc.)<br />
Article 140. Regarding those given in Article 138<br />
item 2, the provisions of Article 36, Article 37,<br />
Article 40, Article 41, Article 47, Section 5 and<br />
Section 6 (excluding Article 76 to Article 78 inclusive)<br />
shall apply mutatis mutandis.<br />
(Advertisement Tower or Elevated Tank, etc.)<br />
Article 141. Regarding those given in Article 138<br />
item (3) or item (4), they shall be of construetion<br />
other than that of masonry or plain concrete<br />
structure.<br />
2 Regarding those given in the preceding paragraph,<br />
the provisions of Article 36, Article 37,<br />
Article 40 to Article 42 inclusive, Article 44,<br />
Article 46 paragraph 1, Article 47, Section 5 and<br />
Section 6 shall apply mutatis mutandis.<br />
(Retaining Walls)<br />
Article 142. Regarding the retaining walls mentioned<br />
in Article 138 item (5), in a addition to applying<br />
the provisions mutatis mutandis to the provisions<br />
which apply mutatis mutandis in Article<br />
36, Article 37 paragraph 3, Article 51 paragraph<br />
1, Article 62, Article 72 paragraph 1, Article 72,<br />
Article 73 paragraph 1, Article 74, Article 75,<br />
Article 79 and Section 7, the following items shall<br />
be required for their structures :<br />
(1) To be constructed of reinforced concrete,<br />
stone wall, and other constructions that use<br />
materials to resist decay;<br />
(2) Back of stone wall shall be consolidated with<br />
concrete, and joints between each stones shall<br />
be well cemented; <<br />
(3) Weep holes shall be placed to chain off<br />
water in back of retaining wall.<br />
(Moderation of Restrictions for Temporary<br />
Buildi ngs)<br />
Article 143. Regarding temporary buildings given<br />
in the first column of the following table the<br />
provisions of each column shall not apply :<br />
Kind of<br />
temporary<br />
building<br />
Temporary buildings<br />
prescribed<br />
in the provisions<br />
of Article 85<br />
paragraph 2<br />
Temporary<br />
ing under<br />
build-<br />
the<br />
provisions ot<br />
Article<br />
graph<br />
85 para-<br />
4 of the<br />
Law<br />
Provisions that do not apply<br />
The provisions of Article 22,<br />
Article 29, Article 30, Article<br />
35, Article- 37, Article 38,<br />
Article 46, Article 48, Article<br />
49, Article 67, Article 70,<br />
.article i±^, /irucie jl±** anu<br />
Chapter V to Chapter VII<br />
inclusive<br />
The provisions of Article 22,<br />
Article 29, Article 30, Article<br />
35, Article 37, Article 38,<br />
Article 46, Article 49, Article<br />
67, Article 70, Article 112,<br />
Article 114 and Chapter VI<br />
to Chapter VII<br />
-36<br />
Temporary building<br />
under the<br />
provisions of<br />
Article 85 paragraph<br />
5 of the<br />
Law<br />
The provisions of Article 22,<br />
Article 29, Article 30, Article<br />
35, Article 37, Article 38,<br />
Article 46, Article 49, Article<br />
67, Article 70 and Chapter<br />
VI and Chapter VII<br />
2 Of the structures given in Article 138 item (1)<br />
to item (4) inclusive, which with the period of<br />
temporary occupation ndt to exceed 2 years, the<br />
parts concerning the application mutatis mutandis<br />
of the provisions of Article 37, Article 67 and<br />
Article 70 mentioned In the provisions of Article<br />
139 to Article 141 inclusive shall not apply.<br />
Supplementary Provisions :<br />
(Date of Enforcement)<br />
1. In this Cabinet Order, the provisions of Chapter<br />
I Section2 shall come into force as from the day<br />
of its promulgation and other provisions, as from<br />
November 23, 1950.<br />
(Special Case of First Examination of Qualification<br />
after the Enforcement of the Law)<br />
2. In the first examination of qualification after<br />
the enforcement of the Law irrespective of the<br />
provisions of Article 4 paragraph 3, a person who<br />
had administrative experience for more than 10<br />
years regarding the former Urban Building Law<br />
(Law No. 37 of 1919) or execution of the Building<br />
Standard Law and who also, within five years<br />
previous to the day of enforcement of the said<br />
examination of qualification, had post as chief of<br />
bureau, division, or section concerned with building<br />
administration in To, Do, Fu or prefecture,<br />
or Reconstruction Board, Construction Board or<br />
Ministry of Construction for more than one year,<br />
or a person who is recognized as having the<br />
knowledge and actual and practical experience<br />
equal or superior to those mentioned above, the<br />
subjects given in item (6) to item (8) inclusive<br />
shall be exempted.<br />
(Temporary Examination of Qualification)<br />
3. Examination for qualification to be conducted<br />
within one year reckoning from the day of enforcement<br />
of the Law, in addition to the examination<br />
of qualification under the provisions of<br />
Article 3 and Article 4, temporary examination<br />
for qualification may be held in accordance with<br />
the provisions of paragraph 4 and.paragraph 5 of<br />
the Supplementary Provisions.<br />
4. Temporary examination for qualification shall<br />
be conducted to test the knowledge and experience<br />
concerning technics and Laws and Ordinances on<br />
buildings necessary for confirmation thereof in<br />
accordance with the provisions of Article 6 paragraph<br />
1 item (4) of the Law in respect to buildings.<br />
5. Temporary examination for qualification shall<br />
be conducted on deliberation of past records and<br />
by tests ; deliberation of past records pertains to
uilding administration or practical experiences<br />
respecting building execution while tests shall be<br />
made on the subjects given in the first column<br />
<br />
as may be required. However, persons coming<br />
under the second column shall be exempted from<br />
the subjects shown in the left:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
6. Temporary examination for qualification in<br />
accordance with the provisions of the preceding<br />
three paragraphs shall be effective for the period<br />
of 3 years only reckoning from the day of the<br />
enforcement of the Law.<br />
(Special Cases of Fire Doors)<br />
7. In case of providing fire door in accordance<br />
with the provision of Article 64 of the Law, the<br />
buildings to bi built within the period of one<br />
year from the day of the enforcement of this<br />
Cabinet Order in the district to be designated<br />
upon obtaining the consent of fire-chief of chief<br />
of fire-station in charge of the district concerned,<br />
if the administrative agency concerned deems it<br />
extremely difficult to provide the fire door and<br />
other fire prevention equipments, the simplified<br />
fire-door constructions mentioned in any of the<br />
following items may take place of the fire-door B<br />
prescribed by the provisions of the same Article.<br />
In this case the provision of Article 110 paragraph<br />
5 shall not apply:<br />
(1) Those made of sheet metal, asbestos sheet,<br />
magnesium-cement sheet, fire-resisting lumber,<br />
wired glass and others of the similar materials,<br />
not coming under the ways of construction<br />
mentioned in Article 110 paragraph 2 item (1)<br />
or item (4) to item (6) inclusive;<br />
(2) Those with wooden frames covered outside<br />
with sheet metal.<br />
(Partial Amendment of Enforcement Provisions<br />
of the Local Autonomy Law)<br />
8. The Enforcement Provisions of the Local Autonomy<br />
Law (Cabinet Order No. 19 of 1947) shall<br />
be partially amended as follows :<br />
Article 18 paragraph 1 item (10) shall be<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
amended as follows :<br />
10 Deleted.<br />
(Partial Amendment of Building Restriction<br />
Ordinance Executing Areas of War-Damage<br />
Rehabilitation Land Re-adjustment)<br />
9. The Building Restriction Ordinance in Execution<br />
Areas of War-Damage Rehabilitation Land Readjustment<br />
(Imperial Ordinance No. 389 of 1946)<br />
shall be partially amended as follows :<br />
In Article 1, "and Article 25 of the Urban<br />
Building Law" and "and Article 29-(2) of the<br />
Urban Building Law Enforcement Ordinance"<br />
shall be deleted.<br />
Minister of Construction<br />
MASUDA Kaneshichi<br />
Prime Minister<br />
YOSHIDA Shigeru<br />
MINISTERIAL<br />
ORDINANCE<br />
Ministry of Construction Ordinance<br />
No.40<br />
November 16, 1950<br />
I hereby establish the Building Standard Law<br />
Enforcement Regulations as follows in order to<br />
execute the Building Standard Law (Law No. 201 of<br />
1950) and the Building Standard Law Enforcement<br />
Order (Cabinet Order No. 338 of 1950) :<br />
Minister of Construction<br />
MASUDA Kaneshichi<br />
Building Standard Law Enforcement<br />
Regulations<br />
(Form of Application for Confirmation)<br />
Article JL Application for Confirmation in accord-<br />
3?-
ance with the provisions of Article 6 paragraph<br />
1 of the Building Standard Law (hereinafter<br />
called the "Law") shall be as given in annexed<br />
form No. 1 consisting of original and<br />
a copy accompanied by various drawings and<br />
documents according to respective building, or<br />
for buildings mentioned in item (4) of the same<br />
paragraph, the drawings and documents given in<br />
column (a) of the following table, for buildings in<br />
item (1) of the same paragraph the drawings and<br />
documents given in columns (a) and (b), for<br />
buildings in item (2) and item (3) of the same<br />
paragraph the drawings and documents given in<br />
columns (a), (b) and (c). However, the drawings<br />
and documents in column (a) may he combined<br />
into convenient form :<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
2 In case times to be shown in the table of the<br />
preceding paragraph are shown in other drawings<br />
and documents which are to be submitted with<br />
the application, irrespective of the provision of<br />
the same paragraph, it is not required to include<br />
in the drawings and documents concerned.<br />
3 When special administrative agency deems it<br />
specially necessary for giving confirmation that<br />
the building in the submitted application is properly<br />
prepared in accordance with the provisions<br />
of the regulation based on the provisions of<br />
Article 39 paragraph 2, Article 40, Article 43<br />
paragraph 2, Article 53 paragraph 3 and Article<br />
68 paragraph 3 of the Law, it may, by regulations<br />
in addition to the provisions provided in<br />
the same paragraph, establish necessary provisions<br />
respect to drawings and documents to be<br />
submitted together with the application.<br />
4 In case the plans for construction of the building<br />
in the application are drawings and documents<br />
prepared by architect, the special _administrative<br />
agency may, irrespective of the<br />
provision of the paragraph 1, by regulation,<br />
prescribe to the effect that it need not to submit<br />
whole or a part of the drawings and documents<br />
given in column (c) of the same Table.<br />
(Form of Notice of Confirmation)<br />
Article 2. The notice of confirmation in accordance<br />
with the provision of Article 6 paragraph 2<br />
of the Law shall be given by filling in the column<br />
of confirmation notice in a copy of application<br />
for confirmation mentioned in paragraph 1 of<br />
the preceding Article.<br />
2 The notice to the effect that it fails to satisfy<br />
the requirements of the provisions of Article 6<br />
paragraph 3 of the Law shall be done by the<br />
notice of Form No. 2 in annexed sheet accompanied<br />
with the copy of the application for confirmation<br />
of paragraph 1 of the preceding Article<br />
together with the accompanying drawings and<br />
documents in the application.<br />
3 The form of notice for notifying to the effect<br />
that no decision will be possible as to whether<br />
it satisfy or fails to satisfy the requirements of<br />
the provisions of Article 6 paragraph 3 of the<br />
Law shall be as shown in Form No.3 in annexed<br />
sheet.<br />
(Application for Confirmation of Structural and<br />
Form of Notice of Confirmation)<br />
Article 3. Application for confirmation to be submitted<br />
to the building official in case one intends<br />
to erect a structure given in Article 138 of the<br />
Building Standard Law Enforcement Ordinance<br />
(hereinafter called *Ordinance") shall be as<br />
shown in Annexed Form No. 4 original and copy<br />
together with accompaniment of the following<br />
drawings and documents.<br />
-38-
2 In case application for confirmation respect to<br />
structure is to be submitted in combination with<br />
the application for confirmation of building, in place<br />
of the application for confirmation of the preceding<br />
paragraph, the application for confirmation of<br />
Article 1 paragraph 1 accompanied with the documents<br />
inscribed with the required matters in the<br />
column "outline of structure" within the Annexed<br />
Form No. 4 and the drawings given in the Table<br />
of the preceding paragraph (sketch map of<br />
surroundings of site or plot plan may be left out<br />
in case the items to*be shown in sketch map of<br />
surroundings of site or in plot plan are shown in<br />
sketch map of surroundings of site or in the plot<br />
plan required in Article 1 paragraph 1) shall be<br />
submitted.<br />
3 In case the plans for construction of structure<br />
in the application are drawings, specifications<br />
and documents prepared by architect, the special<br />
administrative agency may, irrespective of the<br />
preceding two provisions and by regulations,<br />
prescribe to the effect that the structural details<br />
given in the Table of paragraph 1.<br />
4 The provisions of the preceding Article shall<br />
apply mutatis mutandis respect to the notice of<br />
confirmation of structure.<br />
(Report of Completion of Work and Form of Inspection<br />
Completed)<br />
Article 4. Annexed Form No. 5 and Form No. 6<br />
shall be used respectively for written report<br />
(report, work completed) on work completed in<br />
accordance with the provisions of Article 7<br />
paragraph 1 of the Law and for certificate of inspection<br />
completed in accordance with the<br />
provisions of paragraph 3 of the same Article.<br />
(Form of Certificate of Identification)<br />
Article 5. Annexed Form No.7shallbe used as the<br />
certificate of identification to be carried by the<br />
public officials of city, town or village, or To,<br />
Do, Fu or prefecture concerned who are ordered<br />
by building official or by special administrative<br />
agency or commissioned by building official in<br />
accordance with the provisions of Article 13 of<br />
the Law.<br />
(Report of Starting of Work and Report of<br />
Removal)<br />
Article 6. The report (report on work to start) to<br />
-39-<br />
the effect that the work onbuilding is to be started<br />
and report (report On removal) to the effect that<br />
the building has been removed as required bf<br />
the provision of Article 15 paragraph 1 of the<br />
Law, shall be submitted through the hands of building<br />
official by using the Annexed Form No. 8 and<br />
the Annexed Form No. 9 respectively.<br />
(Application for Designation of the Location of<br />
Road)<br />
Article 7. A person who wishes to be designated<br />
with the location of road as prescribed in the<br />
provision of Article 42 paragraph 1 item (5) of<br />
the Law shall submit two copies, original and<br />
copy, of application to the special administrative<br />
agency together with respective drawings given<br />
in the following table and the written consent of<br />
the owner of land to become the site of the road<br />
(hereinafter called "Land") or a person or persons<br />
holding the rights over the land or building or<br />
structure in the land:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
(Public Notice and Informing Designation of<br />
Location of Road)<br />
Article 8. When special administrative agency designates<br />
the location of road by basing on the<br />
application mentioned in the preceding Article<br />
paragraph 1, it shall give out public notice to<br />
the effect and at the same time, the notice to<br />
the effect shall be sent to the applicant.<br />
(Form of Sign Board for Confirmation on Working<br />
Site)<br />
Article 9. The form of sign for confirmation on<br />
working site in accordance with Article 89 paragraph<br />
1 of the Law shall be as shown in Annexed<br />
Form No. 10.<br />
(Application Form for Examination of Qualification)<br />
Article 10. Application form for examination of<br />
qualification of building officials in accordance<br />
with the provision of Article 9 of the Ordinance<br />
shall bs as shown in Annexed Form No. ll.<br />
Supplementary Provision :<br />
This Ministerial Ordinance shall come into force<br />
as from November 23, 1950.
No.<br />
No.<br />
Annexed Form No. 1<br />
Form No. 1 Original (B 5)<br />
(Original) Application for Confirmation (Building)<br />
(Note) Before filling in, read carefully the items to be noted<br />
in lower column of copy<br />
I hereby apply for confirmation in accordance with the provisions<br />
of Article 6 paragraph 1 of -Building Standard Law. This application<br />
and annexed drawings and documents are inscribed with<br />
matters and facts nothing but true.<br />
Name of applicant : (Seal)<br />
1. Name and address of Owner|<br />
-^Column for fee<br />
Tel. (<br />
2. Name and address of agent Tel. (<br />
3. Designer's qualification his<br />
name and address<br />
Class Architect Registered No. Tel. (<br />
o<br />
0<br />
4. Name and address of contractor<br />
or builder<br />
fi..<br />
.2 <br />
Date :<br />
14. Other matters if required<br />
a) Use<br />
d) _RoofingL materials)<br />
b) Kind of work<br />
e) Exterior wall |<br />
c) Structure<br />
f) Underneath eave<br />
a©<br />
Story of floor floor floor floor Total<br />
& £<br />
TO -W* Part applied<br />
CID Part not applied<br />
|fe £<br />
:s •EP Total<br />
h) Dimension of columns!<br />
1) Highest part(<br />
CO ow Spacing of horizontal<br />
m) Highest<br />
0)<br />
material<br />
eave height<br />
3a Height of story or<br />
n) Height of<br />
floor<br />
living room<br />
Ceiling height of liv-<br />
o) Latrine<br />
Water closet<br />
in8<br />
ing room<br />
Building equipment<br />
facility<br />
[^Column for receiving of file •E^Column for opinion<br />
of Fire Board<br />
bail out (kairyo)<br />
lolumn for Decisioni^olumn for Con-<br />
XlllllCtLiUlt<br />
nu.<br />
Date : i Date:<br />
Signed by :<br />
(Seal of person in charge)<br />
Signed by:<br />
(Seal of person<br />
in charge)<br />
-40-
Annexed Form No. 1 Copy (B 5)<br />
Copy Confirmation Notice (Building)<br />
o<br />
0<br />
^Column for Confirmation Notice :<br />
I thereby notify that this application and the plan and design of building and accompanied<br />
drawing and documents thereof as well as the prepared site for building and building<br />
equipments and facilities are confirmed as satisfying the requirements of the provisions<br />
of the Law and the Orders, Regulations based thereto.<br />
Confirmation No.<br />
Date of confirmation :<br />
1. Name and address of owner]<br />
2. Name and address of agent]<br />
3. Qualification of designer<br />
Name and address<br />
:<br />
4. Contractor or builder<br />
Name and address<br />
a) Name<br />
No. of<br />
of<br />
lot<br />
place and<br />
.2v<br />
OHW<br />
*1O<br />
16<br />
b) Use zone<br />
c) Fire zone<br />
6. Principal uses<br />
8. Area of site<br />
9. Building area<br />
10. Total floor area<br />
12. When work expectedstart | Date:<br />
14. Other matters deemed<br />
necessary<br />
a) Use<br />
03<br />
II<br />
"Is<br />
-n.2<br />
in.H<br />
b) Kind of work<br />
c) Structure<br />
According to story of<br />
floor<br />
Part applied for<br />
Part not applied<br />
Total<br />
h) Dimention of column<br />
i) Spacing of horizontal I<br />
members<br />
j<br />
j) Story height<br />
k) Ceiling height of<br />
living room<br />
Building Official (Name^ ___Seai<br />
Tel. (<br />
)..<br />
Tel. ( J_<br />
Class Architect Registration No. Tel (<br />
Construction Contractor's Registration No. Tel. (<br />
1^ d) Other<br />
district, zone,<br />
area<br />
7. Kind of<br />
work<br />
^^HSSiSa Total<br />
New, enlargement,<br />
remodel , removal ,<br />
change of use, large<br />
scale repair, large<br />
scale remodelling<br />
tio fc 3*0<br />
u_OS<br />
£To<br />
13. When work expected to complete | Date:<br />
d) Roofing<br />
materials<br />
e) Exterior<br />
wall<br />
f) Underneath<br />
eave<br />
floor floor floor Total<br />
1) Height<br />
highest<br />
of<br />
point<br />
m) Highest<br />
n)<br />
eave<br />
Floor height]<br />
of living room|<br />
o) Kind<br />
latrine<br />
of<br />
Residential. Commercial,<br />
Quasi-industrial,<br />
Industrial,not designated]<br />
Fire zone A, Fire zone<br />
B, not designated<br />
[Water closet<br />
bail<br />
(kairyo)<br />
out<br />
p) Kind of building<br />
equipment<br />
(Note) In case building in application constitute 2 or more houses, fill in column "brief description<br />
of building in application according to houses" in each separate paper for<br />
each separate house (excluding house with total ficor area of one house less than 10<br />
sq.m.) and to be attached.<br />
Where marked ^ applicant not to fill in. Column 4 to be left vacant if no confractor<br />
or builder is decided upon. Mark by ( ) the columns 5-b), c), 7, 15-c). Column6<br />
to be described distinctly and concretely by facts. If there any other items deemed<br />
appropriate to go in there, put in column 14. Columns 15 h), i) to be filled in for<br />
wooden structures only. Column 15-p) in separate sheet preferably. Numerals in<br />
Arabic and unit in meter preferred. Other item believed to belong here but not able<br />
to write may be written in separate sheet to be attached to this sheet.<br />
-41-
Annexed Form 1. Additional sheet on outline according to houses
I<br />
a§<br />
I<br />
o<br />
.2gft<br />
P<br />
s<br />
•EII<br />
cvi<br />
o<br />
a<br />
2*<br />
43 TJ<br />
bo<br />
c3 +* ft<br />
8SB<br />
0 *£><br />
3<<br />
Si<br />
P<br />
>3<br />
*<br />
%<br />
-s<br />
Ba<br />
o<br />
aa<br />
bfl<br />
ss<br />
I<br />
6<br />
8<br />
§<br />
Annexed Form No. 4<br />
Form No. 4 Original (B 5)<br />
(Original) Application for Confirmation (Structure)<br />
(Note) Before filling in, read note in bottom of sheet for copy •E^Column for fee<br />
I hereby submit application for confirmation in accordance with<br />
Article 88 paragraph 1 of the Building Standard Law.<br />
I certify that matters and facts given in this application and<br />
in annexed drawings and documents are true and nothing but<br />
true.'<br />
Name of Applicant<br />
(Seal)<br />
o<br />
1. Name and address of<br />
owner<br />
2. Name and address of<br />
agent<br />
3. Oiialifimtinn nf rlPiRiVnp.r<br />
and his name and ad- | Class Architect Registration No.<br />
dress !<br />
4. Name of contractor or<br />
builder and his address<br />
(Tel.)<br />
(Tel.)<br />
(Tel.)<br />
Construction Contractor, Registration No. (Tel.)<br />
5. Name of place of site<br />
and No.<br />
6. When expect to start<br />
work<br />
Date :<br />
7. When expect to<br />
complete work<br />
Date :<br />
8. Remarks<br />
a) Kind of structure<br />
b) Height of<br />
structure<br />
o<br />
9. Brief<br />
description<br />
of<br />
St ructure<br />
c) Construction<br />
of structure<br />
d) Scope of<br />
structure<br />
^•EColumn for receiving •E^Column for decision •E^•EColumn for confirmation No.<br />
Date : Date :<br />
No.<br />
Signed by : official in charge<br />
(Seal)<br />
No.<br />
Signed by: official in charge<br />
(Seal)<br />
44-
Form No. 4 Copy (B 5)<br />
Copy Notice for Confirmation (Structure)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
o<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
o<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
-45-
u<br />
is<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
o<br />
32te<br />
% 03C3<br />
8S-i<br />
T3<br />
I<br />
o<br />
°g1<br />
.<br />
5<br />
'o<br />
m<br />
o<br />
&<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
a<br />
3<br />
Ifi<br />
o<br />
<br />
<br />
<br />
<br />
-46-
Form No. 7 (front page)<br />
S.5cm<br />
Date : File No. (keep for 1 year)<br />
<br />
Entry<br />
Certificate<br />
to<br />
Building and Construction Site<br />
Seal<br />
''<br />
(Administrative Agency concerned)<br />
Form No. 7 (back page)<br />
Bearer of this certificate is authorized to exercise his duty of inspecting building or<br />
site of work in accordance with the provision of Article of the Building Standard Law<br />
concerned are as follows :<br />
Extracts from Building Standard Law :<br />
Article 12 paragraph 2:-In case the public official of To, Do, Fu or prefecture who<br />
has been ordered by the governor of To, Do, Fu or prefecture, or who has been delegated<br />
the power by the building official or building official intends to make confirmation,<br />
inspection or to give order under the provisions of Article 5 paragraph 2, Article \<br />
6 paragraph 2, Article 8 paragraph 1, Article 9 paragraph 1 or paragraph 1 of the<br />
preceding Article may enter the building concerned or the construction field thereof,<br />
and may test or inspect the building, building equipment, building materials, plans<br />
and specifications and other things concerned with the construction work. However,<br />
in case he enters the building actually used for the purpose of living place, he shall,<br />
in advance, obtain the consent of the resident thereof.<br />
Article 13. The public official of To, Do, Fu or prefecture who has been ordered by<br />
building official or the governor of To, Do, Fu or prefecture, or who has been delegated<br />
the power by the building official, in case he enters the building or construction<br />
field in accordance with the provision of paragraph 2 of the preceding.Article, he<br />
shall carry with him the certificate of identification and shall show him the same<br />
when requested by the person concerned.<br />
47-
Form No. 8<br />
Form No. 8 (B 5)<br />
Report for starting of work in accordance with the provision of Article 15<br />
paragraph 1 of the Building Standard Law<br />
Date<br />
To : , Governor<br />
Name and address of owner: Seal<br />
1. Building site<br />
2. When expect to<br />
start work<br />
Date :<br />
3. Time required to<br />
complete from<br />
years<br />
the day started<br />
:_<br />
months<br />
•E^•EColumnfor Organ through which<br />
this file is received<br />
Confirmation No. No.<br />
Day of Confirmation 1 Date:<br />
4. Kind of work New construction Enlargement Remodelling<br />
5. Principal uses<br />
21<br />
MO<br />
£!u<br />
'3 aj<br />
Q3^<br />
-"SS<br />
a) Use<br />
b) Structure<br />
c) Total area<br />
7. Appropriation for<br />
work<br />
.5 ,n<br />
2-3S<br />
'351<br />
|£'o5<br />
.a**<br />
\x^ **5
w5<br />
1 u<br />
p<br />
d<br />
55<br />
£<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
s<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
o<br />
<br />
<br />
8.5<br />
<br />
<br />
<br />
<br />
<br />
50-
51-