Cleaning, disinfection and sterilization - BERCHTOLD GmbH & Co. KG
Cleaning, disinfection and sterilization - BERCHTOLD GmbH & Co. KG
Cleaning, disinfection and sterilization - BERCHTOLD GmbH & Co. KG
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Inhaltsverzeichnis<br />
2011-02-09<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
Single <strong>and</strong> combination lights<br />
CHROMOPHARE ® generation D <strong>and</strong> E<br />
Read the instructions before beginning any work.
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
General cleaning <strong>and</strong> <strong>disinfection</strong><br />
2<br />
The cleaning <strong>and</strong> <strong>disinfection</strong> of the operating light shall only be<br />
made by a hygiene specialist or the person who is instructed by<br />
the hygiene specialist.<br />
Only chemicals which have been tested in terms of material<br />
compatibility <strong>and</strong> released by <strong>BERCHTOLD</strong> shall be used. Special<br />
care is necessary for the choice of the chemical product as well<br />
as their concentration.<br />
If the each current list, which can be viewed on the internet <strong>and</strong> is<br />
also available on request, does not include a disinfectant or<br />
detergent, it shall not be used, since functional components can<br />
be modified or damaged.<br />
Prior to actual <strong>disinfection</strong>, perform a thorough cleaning to<br />
remove any visible impurities, such as blood, etc.<br />
Do not use any sharp, pointed or abrasive objects during<br />
cleaning, as there is always a risk of damaging the surface.<br />
Damaged surfaces become exposed to chemical substances<br />
during subsequent cleaning or <strong>disinfection</strong>. This damages the<br />
surface.<br />
Therefore, only a soft brush <strong>and</strong> a mild cleaning agent (or a<br />
cleaning disinfectant) are allowed for cleaning heavy <strong>and</strong><br />
stubborn impurities. When all visible impurities are gone,<br />
<strong>disinfection</strong> is performed.<br />
NOTE!<br />
Any implied warranty claim terminates when these<br />
guidelines are ignored.<br />
NOTE!<br />
The implied warranty is only valid for undamaged<br />
surfaces!
Recommended cleaners <strong>and</strong><br />
disinfectants<br />
Wet <strong>disinfection</strong> instructions for<br />
support system, light head <strong>and</strong> wall<br />
control unit<br />
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
NOTE!<br />
Current recommendations:<br />
� Surface disinfectants <strong>and</strong> detergents for<br />
manual preparation<br />
� Disinfectants <strong>and</strong> detergents for automatic<br />
preparation<br />
can be viewed on the internet <strong>and</strong> are also<br />
available on request.<br />
NOTE!<br />
The operator should refer to recognized<br />
st<strong>and</strong>ards for hygiene <strong>and</strong> <strong>disinfection</strong>.<br />
When cleaning, only a thin liquid film may be applied.<br />
After wiping, a thin, coherent, moisturizing film is - from the<br />
perspective of microbiological efficiency - sufficient; the surface<br />
does not have to be "drenched".<br />
In order to prevent a build-up of disinfectant material, clean<br />
regularly with a mild all purpose cleaner.<br />
Regularity depends on the frequency of the treatment. We<br />
recommend that cleansing be performed at least once a month.<br />
Clean the surgical lights with a damp cloth only, not a wet cloth.<br />
3
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
4<br />
CAUTION!<br />
Improper use of <strong>disinfection</strong> products can lead<br />
to product damage!<br />
Not following or adhering to the information <strong>and</strong><br />
instructions in this chapter can result in product<br />
damage!<br />
It also voids any implied warranty claims!<br />
Therefore:<br />
– When cleaning <strong>and</strong> disinfecting, make sure<br />
that no liquid penetrates the light head or<br />
support system components.<br />
– The surface disinfectants may only be used in<br />
the concentration prescribed by the<br />
manufacturer.<br />
– The use of NATRONLAUGE can cause surface<br />
changes on coated aluminum components<br />
<strong>and</strong> impair the service life of the product.<br />
– If the surface disinfectant is used incorrectly,<br />
such that a large amount of liquid remains on<br />
the surface, it will cause increased coating<br />
dissolution because the product is continually<br />
"shifted" around the surface but never<br />
removed. In case of an increased layer<br />
composition of surface disinfectant, it must be<br />
thoroughly cleansed.
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
– Due to possible damage to the materials, no<br />
solutions are suitable that are based on<br />
halogen-splitting bonds, strong organic acids<br />
<strong>and</strong> oxygen-splitting bonds, solvents, fuel or<br />
other.<br />
– In order to avoid damages to the stainless steel<br />
parts, only use disinfectants without chlorides or<br />
halogenoids.<br />
– Avoid contact between aldehyde <strong>and</strong> amino<br />
products.<br />
Therefore, especially if an amino-based<br />
product was used previously, before applying<br />
the aldehyde-based disinfectant for the first<br />
time, an intermediate cleaning step has to be<br />
performed. This is very important because<br />
disregarding this step may result in residue no<br />
longer being able to be removed.<br />
– With regard to the microbiological<br />
effectiveness, please contact the<br />
manufacturer of the disinfectant.<br />
5
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
Recommended cleaners <strong>and</strong><br />
disinfectants<br />
6<br />
The following cleaners <strong>and</strong> disinfectants are recommended for<br />
manual cleaning:<br />
Manufacturer Name<br />
BODE Dismozon ® pur<br />
BODE Kohrsolin ® FF<br />
BODE Kohrsolin ® extra<br />
BODE Mikrobac ® forte (only for E series)<br />
Dr. Weigert neoform MED AF<br />
Dr. Weigert neoform MED FF<br />
Dr. Weigert neoform D extra<br />
ECOLAB Incidin Extra N<br />
ECOLAB Incidin plus<br />
ECOLAB Incidin ® Rapid<br />
ECOLAB Incidin ® Liquid<br />
ECOLAB Incidur ® Spray<br />
ECOLAB Incidur ®<br />
Merz Hygiene<br />
<strong>GmbH</strong><br />
Pursept- A Xpress<br />
Schülke&Mayr Perform ®<br />
Schülke&Mayr Terralin ® Protect (only for E series)<br />
Schülke&Mayr mikrozid ® sensitive Wipes<br />
Schülke&Mayr mikrozid ® sensitive Liquid<br />
STERIS <strong>Co</strong>verage ® Spray HB Plus<br />
STERIS <strong>Co</strong>verage ® Spray TB Plus<br />
STERIS <strong>Co</strong>verage ® Plus Germicidal Surface Wipes<br />
Lysoform Aldasan ® 2000
Recommended cleaners <strong>and</strong><br />
disinfectants<br />
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
Manufacturer Name<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
Lysoform Lysoformin ® spezial<br />
Lysoform Lysoformin ® Plus<br />
Tana-Chemie<br />
<strong>GmbH</strong><br />
Tana-Chemie<br />
<strong>GmbH</strong><br />
Apesin ® AP 100<br />
Apesin ® rapid<br />
7
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
H<strong>and</strong>le sleeves,<br />
manual <strong>disinfection</strong><br />
H<strong>and</strong>le sleeves,<br />
thermal preparation<br />
8<br />
Disinfect the h<strong>and</strong>le sleeves as follows:<br />
� Alcohol, QAV or aldehyde-based disinfectant.<br />
� After cleaning, make sure to completely rinse the sleeve with<br />
water to remove any residue.<br />
CAUTION!<br />
Incorrect manual <strong>disinfection</strong> causes product<br />
damages!<br />
Not following or adhering to the instructions listed<br />
can result in product damage!<br />
It also voids any implied warranty claims!<br />
Therefore:<br />
– Avoid dipping in enzyme-based cleaner for<br />
long periods.<br />
The h<strong>and</strong>le sleeves are made of heat- <strong>and</strong> impact-resistant<br />
plastic.<br />
Prepare the h<strong>and</strong>le sleeves as follows:<br />
� Use alkaline-based cleaner without active chlorine<br />
� Neutralize with acidic neutralizer<br />
The h<strong>and</strong>le sleeves can be machine cleaned via<br />
thermo<strong>disinfection</strong> at temperatures of up to 93° C for 10 minutes.
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
H<strong>and</strong>le sleeves, sterilizing Clean <strong>and</strong> disinfect h<strong>and</strong>le sleeves in the usual way before<br />
<strong>sterilization</strong>.<br />
The h<strong>and</strong>le sleeves are placed in a suitable <strong>sterilization</strong> packaging<br />
(one-time <strong>sterilization</strong> packaging, e.g. film/paper <strong>sterilization</strong> bags;<br />
single or double packaging) <strong>and</strong> sterilized.<br />
The h<strong>and</strong>le sleeves can be steam sterilized. The recommended<br />
parameters are:<br />
� 121°C/1.3 bar; 25 to 30 minutes (st<strong>and</strong>ard)<br />
� 134°C/ ca. 3 bar; 3 minutes (st<strong>and</strong>ard)<br />
� 134 °C/2-3 bar; 18 minutes (special cases)<br />
When loading the autoclave, make sure the open end of the<br />
sleeve is pointing down. Allow sufficient space around each<br />
h<strong>and</strong>le sleeve <strong>and</strong> do not allow them to come in contact with<br />
any other items being sterilized.<br />
CAUTION!<br />
Incorrect use of disinfectants can cause product<br />
damages!<br />
Not following or adhering to the instructions listed<br />
can result in product damage!<br />
It also voids any implied warranty claims!<br />
Therefore:<br />
– Hot air, ethylene oxide, formaldehyde <strong>and</strong> lowtemperature<br />
plasma <strong>sterilization</strong> are not<br />
permitted.<br />
9
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
Recommended cleaners <strong>and</strong><br />
disinfectants<br />
10<br />
The following cleaners <strong>and</strong> disinfectants are recommended for<br />
machine cleaning:<br />
Manufacturer Name<br />
Dr. Weigert neodisher ® MediClean forte<br />
Dr. Weigert neodisher ® FA<br />
ECOLAB Sekumatic ® MultiClean<br />
ECOLAB Sekumatic ® FNZ<br />
Merz Hygiene<br />
<strong>GmbH</strong><br />
Merz Hygiene<br />
<strong>GmbH</strong><br />
Mucapur – AF (0,5% - 55°C)<br />
Mucapur – Z (0,1% - 55°C)<br />
Bode Dismoclean ® 25 acid<br />
Bode Dismoclean ® 24 vario<br />
Schülke&Mayr Thermosept ® NKZ<br />
Schülke&Mayr Thermosept ® RKF<br />
Schülke&Mayr Thermosept ® alka clean Forte<br />
CAUTION!<br />
Limited warranty on h<strong>and</strong>les!<br />
Sterilizable h<strong>and</strong>les are subject to natural wear.<br />
Therefore:<br />
– It must be pointed out that a normal life time of<br />
approx 100 cleaning cycles is possible.<br />
– Damaged h<strong>and</strong>les must not be used.<br />
July 28 th , 2011
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
11
Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />
<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />
For Seit more mehr than als 80 85 Jahren years, <strong>BERCHTOLD</strong> gehört <strong>BERCHTOLD</strong> has been zu one den of weltweit the world's führenleading<br />
developers den Entwicklern <strong>and</strong> manufacturers und Herstellern of hochwertiger high-quality chirurgischer surgical equipment. As a<br />
specialist Ausrüstungen. for OR Als equipment, Spezialist für we die offer OP-Ausstattung best-in-class bieten products, wir many Best-in-years<br />
of Class experience Produkte, in langjährige planning <strong>and</strong> Erfahrung project in management, Planung und as well as personalized<br />
service. Projektmanagement We measure our und success Service by mit the einer quality persönlichen of our Note.<br />
relationships Unseren Erfolg with messen customers wir an <strong>and</strong> der employees. Qualität unserer Kunden- und<br />
Mitarbeiterbeziehungen.<br />
Our products <strong>and</strong> services<br />
• Unsere CHROMOPHARE Produkte und Dienstleistungen...<br />
• CHROMOPHARE® Operations- und Untersuchungsleuchten<br />
• ChromoVision® Kamerasysteme<br />
• ChromoView Monitorarme<br />
• OPERON® OP-Tische und Zubehör<br />
• ORICS® Telemedizin<br />
• SUPERSUITE® maßgeschneiderte Komplettlösungen für den OP<br />
• Service und Installation durch eigens geschulte Spezialisten<br />
• Entwicklung, Beratung, Projektmanagement und Kundenbetreuung<br />
® surgical <strong>and</strong> examination lights<br />
• ChromoVision ® camera systems<br />
• ChromoView monitor arms<br />
• TELETOM ® ceiling mounted systems<br />
• OPERON ® surgical tables <strong>and</strong> accessories<br />
• ORICS ® Telemedicine<br />
• SUPERSUITE ® custom-designed OR solutions<br />
• 3D-OR Design Software<br />
• Service <strong>and</strong> installation by our own trained specialists<br />
• Development, consulting, project management <strong>and</strong> customer support<br />
We Wir look freuen forward uns auf to Ihre hearing Anfrage from und you begleiten <strong>and</strong> would Sie be gerne happy bei to der help you<br />
with Planung, the planning, Auslegung design, und Installation <strong>and</strong> installation Ihrer nächsten of your next OP-Ausstattung.<br />
OR suite.<br />
<strong>BERCHTOLD</strong> <strong>BERCHTOLD</strong> <strong>GmbH</strong> <strong>GmbH</strong> & <strong>Co</strong>. <strong>Co</strong>. <strong>Co</strong>. <strong>Co</strong>.<strong>KG</strong> <strong>KG</strong><br />
<strong>KG</strong><br />
Ludwigstaler Straße 25 25<br />
78532 Tuttlingen/Germany<br />
Tel. +49 (0) 74 61/181-0<br />
Fax +49 (0) 74 61/181-200<br />
Info@<strong>BERCHTOLD</strong>.biz<br />
www.<strong>BERCHTOLD</strong>.biz<br />
www.<strong>BERCHTOLD</strong>.de<br />
Reprints, even of excerpts, prohibited.<br />
We reserve the right to make changes in technology <strong>and</strong> design.<br />
12