26.10.2012 Views

Cleaning, disinfection and sterilization - BERCHTOLD GmbH & Co. KG

Cleaning, disinfection and sterilization - BERCHTOLD GmbH & Co. KG

Cleaning, disinfection and sterilization - BERCHTOLD GmbH & Co. KG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Inhaltsverzeichnis<br />

2011-02-09<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

Single <strong>and</strong> combination lights<br />

CHROMOPHARE ® generation D <strong>and</strong> E<br />

Read the instructions before beginning any work.


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

General cleaning <strong>and</strong> <strong>disinfection</strong><br />

2<br />

The cleaning <strong>and</strong> <strong>disinfection</strong> of the operating light shall only be<br />

made by a hygiene specialist or the person who is instructed by<br />

the hygiene specialist.<br />

Only chemicals which have been tested in terms of material<br />

compatibility <strong>and</strong> released by <strong>BERCHTOLD</strong> shall be used. Special<br />

care is necessary for the choice of the chemical product as well<br />

as their concentration.<br />

If the each current list, which can be viewed on the internet <strong>and</strong> is<br />

also available on request, does not include a disinfectant or<br />

detergent, it shall not be used, since functional components can<br />

be modified or damaged.<br />

Prior to actual <strong>disinfection</strong>, perform a thorough cleaning to<br />

remove any visible impurities, such as blood, etc.<br />

Do not use any sharp, pointed or abrasive objects during<br />

cleaning, as there is always a risk of damaging the surface.<br />

Damaged surfaces become exposed to chemical substances<br />

during subsequent cleaning or <strong>disinfection</strong>. This damages the<br />

surface.<br />

Therefore, only a soft brush <strong>and</strong> a mild cleaning agent (or a<br />

cleaning disinfectant) are allowed for cleaning heavy <strong>and</strong><br />

stubborn impurities. When all visible impurities are gone,<br />

<strong>disinfection</strong> is performed.<br />

NOTE!<br />

Any implied warranty claim terminates when these<br />

guidelines are ignored.<br />

NOTE!<br />

The implied warranty is only valid for undamaged<br />

surfaces!


Recommended cleaners <strong>and</strong><br />

disinfectants<br />

Wet <strong>disinfection</strong> instructions for<br />

support system, light head <strong>and</strong> wall<br />

control unit<br />

Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

NOTE!<br />

Current recommendations:<br />

� Surface disinfectants <strong>and</strong> detergents for<br />

manual preparation<br />

� Disinfectants <strong>and</strong> detergents for automatic<br />

preparation<br />

can be viewed on the internet <strong>and</strong> are also<br />

available on request.<br />

NOTE!<br />

The operator should refer to recognized<br />

st<strong>and</strong>ards for hygiene <strong>and</strong> <strong>disinfection</strong>.<br />

When cleaning, only a thin liquid film may be applied.<br />

After wiping, a thin, coherent, moisturizing film is - from the<br />

perspective of microbiological efficiency - sufficient; the surface<br />

does not have to be "drenched".<br />

In order to prevent a build-up of disinfectant material, clean<br />

regularly with a mild all purpose cleaner.<br />

Regularity depends on the frequency of the treatment. We<br />

recommend that cleansing be performed at least once a month.<br />

Clean the surgical lights with a damp cloth only, not a wet cloth.<br />

3


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

4<br />

CAUTION!<br />

Improper use of <strong>disinfection</strong> products can lead<br />

to product damage!<br />

Not following or adhering to the information <strong>and</strong><br />

instructions in this chapter can result in product<br />

damage!<br />

It also voids any implied warranty claims!<br />

Therefore:<br />

– When cleaning <strong>and</strong> disinfecting, make sure<br />

that no liquid penetrates the light head or<br />

support system components.<br />

– The surface disinfectants may only be used in<br />

the concentration prescribed by the<br />

manufacturer.<br />

– The use of NATRONLAUGE can cause surface<br />

changes on coated aluminum components<br />

<strong>and</strong> impair the service life of the product.<br />

– If the surface disinfectant is used incorrectly,<br />

such that a large amount of liquid remains on<br />

the surface, it will cause increased coating<br />

dissolution because the product is continually<br />

"shifted" around the surface but never<br />

removed. In case of an increased layer<br />

composition of surface disinfectant, it must be<br />

thoroughly cleansed.


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

– Due to possible damage to the materials, no<br />

solutions are suitable that are based on<br />

halogen-splitting bonds, strong organic acids<br />

<strong>and</strong> oxygen-splitting bonds, solvents, fuel or<br />

other.<br />

– In order to avoid damages to the stainless steel<br />

parts, only use disinfectants without chlorides or<br />

halogenoids.<br />

– Avoid contact between aldehyde <strong>and</strong> amino<br />

products.<br />

Therefore, especially if an amino-based<br />

product was used previously, before applying<br />

the aldehyde-based disinfectant for the first<br />

time, an intermediate cleaning step has to be<br />

performed. This is very important because<br />

disregarding this step may result in residue no<br />

longer being able to be removed.<br />

– With regard to the microbiological<br />

effectiveness, please contact the<br />

manufacturer of the disinfectant.<br />

5


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

Recommended cleaners <strong>and</strong><br />

disinfectants<br />

6<br />

The following cleaners <strong>and</strong> disinfectants are recommended for<br />

manual cleaning:<br />

Manufacturer Name<br />

BODE Dismozon ® pur<br />

BODE Kohrsolin ® FF<br />

BODE Kohrsolin ® extra<br />

BODE Mikrobac ® forte (only for E series)<br />

Dr. Weigert neoform MED AF<br />

Dr. Weigert neoform MED FF<br />

Dr. Weigert neoform D extra<br />

ECOLAB Incidin Extra N<br />

ECOLAB Incidin plus<br />

ECOLAB Incidin ® Rapid<br />

ECOLAB Incidin ® Liquid<br />

ECOLAB Incidur ® Spray<br />

ECOLAB Incidur ®<br />

Merz Hygiene<br />

<strong>GmbH</strong><br />

Pursept- A Xpress<br />

Schülke&Mayr Perform ®<br />

Schülke&Mayr Terralin ® Protect (only for E series)<br />

Schülke&Mayr mikrozid ® sensitive Wipes<br />

Schülke&Mayr mikrozid ® sensitive Liquid<br />

STERIS <strong>Co</strong>verage ® Spray HB Plus<br />

STERIS <strong>Co</strong>verage ® Spray TB Plus<br />

STERIS <strong>Co</strong>verage ® Plus Germicidal Surface Wipes<br />

Lysoform Aldasan ® 2000


Recommended cleaners <strong>and</strong><br />

disinfectants<br />

Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

Manufacturer Name<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

Lysoform Lysoformin ® spezial<br />

Lysoform Lysoformin ® Plus<br />

Tana-Chemie<br />

<strong>GmbH</strong><br />

Tana-Chemie<br />

<strong>GmbH</strong><br />

Apesin ® AP 100<br />

Apesin ® rapid<br />

7


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

H<strong>and</strong>le sleeves,<br />

manual <strong>disinfection</strong><br />

H<strong>and</strong>le sleeves,<br />

thermal preparation<br />

8<br />

Disinfect the h<strong>and</strong>le sleeves as follows:<br />

� Alcohol, QAV or aldehyde-based disinfectant.<br />

� After cleaning, make sure to completely rinse the sleeve with<br />

water to remove any residue.<br />

CAUTION!<br />

Incorrect manual <strong>disinfection</strong> causes product<br />

damages!<br />

Not following or adhering to the instructions listed<br />

can result in product damage!<br />

It also voids any implied warranty claims!<br />

Therefore:<br />

– Avoid dipping in enzyme-based cleaner for<br />

long periods.<br />

The h<strong>and</strong>le sleeves are made of heat- <strong>and</strong> impact-resistant<br />

plastic.<br />

Prepare the h<strong>and</strong>le sleeves as follows:<br />

� Use alkaline-based cleaner without active chlorine<br />

� Neutralize with acidic neutralizer<br />

The h<strong>and</strong>le sleeves can be machine cleaned via<br />

thermo<strong>disinfection</strong> at temperatures of up to 93° C for 10 minutes.


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

H<strong>and</strong>le sleeves, sterilizing Clean <strong>and</strong> disinfect h<strong>and</strong>le sleeves in the usual way before<br />

<strong>sterilization</strong>.<br />

The h<strong>and</strong>le sleeves are placed in a suitable <strong>sterilization</strong> packaging<br />

(one-time <strong>sterilization</strong> packaging, e.g. film/paper <strong>sterilization</strong> bags;<br />

single or double packaging) <strong>and</strong> sterilized.<br />

The h<strong>and</strong>le sleeves can be steam sterilized. The recommended<br />

parameters are:<br />

� 121°C/1.3 bar; 25 to 30 minutes (st<strong>and</strong>ard)<br />

� 134°C/ ca. 3 bar; 3 minutes (st<strong>and</strong>ard)<br />

� 134 °C/2-3 bar; 18 minutes (special cases)<br />

When loading the autoclave, make sure the open end of the<br />

sleeve is pointing down. Allow sufficient space around each<br />

h<strong>and</strong>le sleeve <strong>and</strong> do not allow them to come in contact with<br />

any other items being sterilized.<br />

CAUTION!<br />

Incorrect use of disinfectants can cause product<br />

damages!<br />

Not following or adhering to the instructions listed<br />

can result in product damage!<br />

It also voids any implied warranty claims!<br />

Therefore:<br />

– Hot air, ethylene oxide, formaldehyde <strong>and</strong> lowtemperature<br />

plasma <strong>sterilization</strong> are not<br />

permitted.<br />

9


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

Recommended cleaners <strong>and</strong><br />

disinfectants<br />

10<br />

The following cleaners <strong>and</strong> disinfectants are recommended for<br />

machine cleaning:<br />

Manufacturer Name<br />

Dr. Weigert neodisher ® MediClean forte<br />

Dr. Weigert neodisher ® FA<br />

ECOLAB Sekumatic ® MultiClean<br />

ECOLAB Sekumatic ® FNZ<br />

Merz Hygiene<br />

<strong>GmbH</strong><br />

Merz Hygiene<br />

<strong>GmbH</strong><br />

Mucapur – AF (0,5% - 55°C)<br />

Mucapur – Z (0,1% - 55°C)<br />

Bode Dismoclean ® 25 acid<br />

Bode Dismoclean ® 24 vario<br />

Schülke&Mayr Thermosept ® NKZ<br />

Schülke&Mayr Thermosept ® RKF<br />

Schülke&Mayr Thermosept ® alka clean Forte<br />

CAUTION!<br />

Limited warranty on h<strong>and</strong>les!<br />

Sterilizable h<strong>and</strong>les are subject to natural wear.<br />

Therefore:<br />

– It must be pointed out that a normal life time of<br />

approx 100 cleaning cycles is possible.<br />

– Damaged h<strong>and</strong>les must not be used.<br />

July 28 th , 2011


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

11


Single <strong>and</strong> combination lights CHROMOPHARE ® generation D <strong>and</strong> E<br />

<strong>Cleaning</strong>, <strong>disinfection</strong> <strong>and</strong> <strong>sterilization</strong><br />

For Seit more mehr than als 80 85 Jahren years, <strong>BERCHTOLD</strong> gehört <strong>BERCHTOLD</strong> has been zu one den of weltweit the world's führenleading<br />

developers den Entwicklern <strong>and</strong> manufacturers und Herstellern of hochwertiger high-quality chirurgischer surgical equipment. As a<br />

specialist Ausrüstungen. for OR Als equipment, Spezialist für we die offer OP-Ausstattung best-in-class bieten products, wir many Best-in-years<br />

of Class experience Produkte, in langjährige planning <strong>and</strong> Erfahrung project in management, Planung und as well as personalized<br />

service. Projektmanagement We measure our und success Service by mit the einer quality persönlichen of our Note.<br />

relationships Unseren Erfolg with messen customers wir an <strong>and</strong> der employees. Qualität unserer Kunden- und<br />

Mitarbeiterbeziehungen.<br />

Our products <strong>and</strong> services<br />

• Unsere CHROMOPHARE Produkte und Dienstleistungen...<br />

• CHROMOPHARE® Operations- und Untersuchungsleuchten<br />

• ChromoVision® Kamerasysteme<br />

• ChromoView Monitorarme<br />

• OPERON® OP-Tische und Zubehör<br />

• ORICS® Telemedizin<br />

• SUPERSUITE® maßgeschneiderte Komplettlösungen für den OP<br />

• Service und Installation durch eigens geschulte Spezialisten<br />

• Entwicklung, Beratung, Projektmanagement und Kundenbetreuung<br />

® surgical <strong>and</strong> examination lights<br />

• ChromoVision ® camera systems<br />

• ChromoView monitor arms<br />

• TELETOM ® ceiling mounted systems<br />

• OPERON ® surgical tables <strong>and</strong> accessories<br />

• ORICS ® Telemedicine<br />

• SUPERSUITE ® custom-designed OR solutions<br />

• 3D-OR Design Software<br />

• Service <strong>and</strong> installation by our own trained specialists<br />

• Development, consulting, project management <strong>and</strong> customer support<br />

We Wir look freuen forward uns auf to Ihre hearing Anfrage from und you begleiten <strong>and</strong> would Sie be gerne happy bei to der help you<br />

with Planung, the planning, Auslegung design, und Installation <strong>and</strong> installation Ihrer nächsten of your next OP-Ausstattung.<br />

OR suite.<br />

<strong>BERCHTOLD</strong> <strong>BERCHTOLD</strong> <strong>GmbH</strong> <strong>GmbH</strong> & <strong>Co</strong>. <strong>Co</strong>. <strong>Co</strong>. <strong>Co</strong>.<strong>KG</strong> <strong>KG</strong><br />

<strong>KG</strong><br />

Ludwigstaler Straße 25 25<br />

78532 Tuttlingen/Germany<br />

Tel. +49 (0) 74 61/181-0<br />

Fax +49 (0) 74 61/181-200<br />

Info@<strong>BERCHTOLD</strong>.biz<br />

www.<strong>BERCHTOLD</strong>.biz<br />

www.<strong>BERCHTOLD</strong>.de<br />

Reprints, even of excerpts, prohibited.<br />

We reserve the right to make changes in technology <strong>and</strong> design.<br />

12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!