05.01.2014 Views

MAGNETIC FLOAT LEVEL TRANSMITTER

MAGNETIC FLOAT LEVEL TRANSMITTER

MAGNETIC FLOAT LEVEL TRANSMITTER

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Magnetic Float Level Transmitter / PFA coated<br />

1001<br />

Electrical connection<br />

~125<br />

~105<br />

82<br />

13 ~30<br />

75 x 80<br />

~30<br />

~85<br />

64 x 58<br />

~25<br />

L = ... ~145<br />

~130<br />

100<br />

L = ...<br />

L = ... ~60<br />

34<br />

~40<br />

~155<br />

~90<br />

110<br />

~135<br />

16 82<br />

14 ~25<br />

80 x 75<br />

~105<br />

~25<br />

95<br />

~135<br />

10 ~30<br />

L = ... ~80<br />

~45<br />

L = ...<br />

~135<br />

~80<br />

57<br />

84<br />

L = ... ~80<br />

~45<br />

55<br />

Connection type: APA / APB ( Ex )<br />

Material quality: Polyester<br />

Cable entry: M20 x 1.5<br />

Ingress protection class: IP 65<br />

Ambient temperature: -10°C ... 100°C<br />

Connection type: ALE<br />

Material quality: Aluminium coated RAL 7001<br />

Cable entry: M20 x 1.5<br />

Ingress protection class: IP 65<br />

Ambient temperature: -40°C ... 100°C<br />

Connection type: AVA / AVDA ( Exd )<br />

Material quality: Stainless steel A4 ( SS316 )<br />

Cable entry: M20 x 1.5<br />

Ingress protection class: IP 67 / ( Exd / IP68 )<br />

Ambient temperature: -40°C ... 85°C<br />

Connection type: DAALA<br />

Material quality: Aluminium<br />

Cable entry: M20 x 1.5<br />

Ingress protection class: IP 65<br />

Ambient temperature: -40°C ... 60°C<br />

Connection type: ALF<br />

Material quality: Aluminium coated RAL 7001<br />

Cable entry: M20 x 1.5<br />

Ingress protection class: IP 65<br />

Ambient temperature: -40°C ... 100°C<br />

Connection type: ALDA ( Exd )<br />

Material quality: Aluminium coated RAL 9006<br />

Cable entry: M20 x 1.5<br />

Ingress protection class: IP 68<br />

Ambient temperature: -40°C ... 100°C<br />

Approvals / Certificates<br />

ATEX*<br />

II 1/2G<br />

II 1/2G<br />

Ex ia c IIC T6 - T4<br />

Ex d ia c IIC T6 - T4<br />

Liquid temperature Exia max. 180°C / Exd max. 120°C<br />

II 1/2G<br />

II 2D<br />

Type of protection intrinsic safety Ex ia IIC switch bzw. temperature switch<br />

Type of protection intrinsic safety Ex ia IIC temperature probe<br />

Type of protection intrinsic safety Ex ia IIC with option /N ( NAMUR EN 60947 )<br />

Type of protection „moulding“<br />

Type of protection „moulding“ with option /N ( NAMUR EN 60947 )<br />

Type of protection „moulding“ with option /R22 ( resistor )<br />

Ex ia c IIC T6 - T3 bzw. Ex d ia c IIC T6 - T4<br />

Ex tD A21 c IP6* T80°C - T190°C bzw. T125<br />

I i<br />

U N<br />

U N<br />

≤ 100 mA<br />

≤ 15 VDC<br />

≤ 250 VDC/AC<br />

II 2G<br />

Ex d c IIC T6 - T4<br />

U i<br />

≤ 28 V<br />

I i<br />

≤ 100 mA<br />

P i<br />

≤ 700 mW<br />

U i<br />

≤ 15 VDC<br />

I i<br />

≤ 60 mA<br />

U N<br />

≤ 250 VDC/AC<br />

P SN<br />

≤ 50 W/VA<br />

P FN<br />

≤ 700 mW<br />

I N<br />

I N<br />

≤ 60 mA<br />

≤ 100 mA<br />

Further electrical connections page 52 - 54<br />

Further process connection according to type key page 10<br />

Further floats page 48 - 51<br />

The magnetic float level transmitter are based on a modular design and can be arranged individually.<br />

Type key page 10 - 13<br />

* = The approval is dependent on the equipment combination<br />

40<br />

KFG Level AG<br />

Ruessenstrasse 4 | CH-6341 Baar | Phone +41 (0)41 766 62 82 | Fax +41 (0)41 766 62 83 | E-Mail info@kfg-level.com | Internet www.kfg-level.com