MAGNETIC FLOAT LEVEL TRANSMITTER
MAGNETIC FLOAT LEVEL TRANSMITTER
MAGNETIC FLOAT LEVEL TRANSMITTER
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Magnetic Float Level Transmitter / PFA coated<br />
1001<br />
Electrical connection<br />
~125<br />
~105<br />
82<br />
13 ~30<br />
75 x 80<br />
~30<br />
~85<br />
64 x 58<br />
~25<br />
L = ... ~145<br />
~130<br />
100<br />
L = ...<br />
L = ... ~60<br />
34<br />
~40<br />
~155<br />
~90<br />
110<br />
~135<br />
16 82<br />
14 ~25<br />
80 x 75<br />
~105<br />
~25<br />
95<br />
~135<br />
10 ~30<br />
L = ... ~80<br />
~45<br />
L = ...<br />
~135<br />
~80<br />
57<br />
84<br />
L = ... ~80<br />
~45<br />
55<br />
Connection type: APA / APB ( Ex )<br />
Material quality: Polyester<br />
Cable entry: M20 x 1.5<br />
Ingress protection class: IP 65<br />
Ambient temperature: -10°C ... 100°C<br />
Connection type: ALE<br />
Material quality: Aluminium coated RAL 7001<br />
Cable entry: M20 x 1.5<br />
Ingress protection class: IP 65<br />
Ambient temperature: -40°C ... 100°C<br />
Connection type: AVA / AVDA ( Exd )<br />
Material quality: Stainless steel A4 ( SS316 )<br />
Cable entry: M20 x 1.5<br />
Ingress protection class: IP 67 / ( Exd / IP68 )<br />
Ambient temperature: -40°C ... 85°C<br />
Connection type: DAALA<br />
Material quality: Aluminium<br />
Cable entry: M20 x 1.5<br />
Ingress protection class: IP 65<br />
Ambient temperature: -40°C ... 60°C<br />
Connection type: ALF<br />
Material quality: Aluminium coated RAL 7001<br />
Cable entry: M20 x 1.5<br />
Ingress protection class: IP 65<br />
Ambient temperature: -40°C ... 100°C<br />
Connection type: ALDA ( Exd )<br />
Material quality: Aluminium coated RAL 9006<br />
Cable entry: M20 x 1.5<br />
Ingress protection class: IP 68<br />
Ambient temperature: -40°C ... 100°C<br />
Approvals / Certificates<br />
ATEX*<br />
II 1/2G<br />
II 1/2G<br />
Ex ia c IIC T6 - T4<br />
Ex d ia c IIC T6 - T4<br />
Liquid temperature Exia max. 180°C / Exd max. 120°C<br />
II 1/2G<br />
II 2D<br />
Type of protection intrinsic safety Ex ia IIC switch bzw. temperature switch<br />
Type of protection intrinsic safety Ex ia IIC temperature probe<br />
Type of protection intrinsic safety Ex ia IIC with option /N ( NAMUR EN 60947 )<br />
Type of protection „moulding“<br />
Type of protection „moulding“ with option /N ( NAMUR EN 60947 )<br />
Type of protection „moulding“ with option /R22 ( resistor )<br />
Ex ia c IIC T6 - T3 bzw. Ex d ia c IIC T6 - T4<br />
Ex tD A21 c IP6* T80°C - T190°C bzw. T125<br />
I i<br />
U N<br />
U N<br />
≤ 100 mA<br />
≤ 15 VDC<br />
≤ 250 VDC/AC<br />
II 2G<br />
Ex d c IIC T6 - T4<br />
U i<br />
≤ 28 V<br />
I i<br />
≤ 100 mA<br />
P i<br />
≤ 700 mW<br />
U i<br />
≤ 15 VDC<br />
I i<br />
≤ 60 mA<br />
U N<br />
≤ 250 VDC/AC<br />
P SN<br />
≤ 50 W/VA<br />
P FN<br />
≤ 700 mW<br />
I N<br />
I N<br />
≤ 60 mA<br />
≤ 100 mA<br />
Further electrical connections page 52 - 54<br />
Further process connection according to type key page 10<br />
Further floats page 48 - 51<br />
The magnetic float level transmitter are based on a modular design and can be arranged individually.<br />
Type key page 10 - 13<br />
* = The approval is dependent on the equipment combination<br />
40<br />
KFG Level AG<br />
Ruessenstrasse 4 | CH-6341 Baar | Phone +41 (0)41 766 62 82 | Fax +41 (0)41 766 62 83 | E-Mail info@kfg-level.com | Internet www.kfg-level.com