Simple Energy Saving <strong>Solutions</strong> - Metering<br />

As the saying goes “if you do<br />

not measure it - you can not<br />

improve it”. Kilowatt hours<br />

meters measure the active<br />

energy used in an electric<br />

installation. This allows the<br />

separate measurement of<br />

energy consumption in<br />

different areas of a large<br />

facility, with the purpose of<br />

allocating energy usage to<br />

different cost centres. The<br />

initial readings can be used<br />

as a baseline for<br />

determining energy usage,<br />

and the subsequent readings<br />

can be useful in identifying<br />

energy saving or wastage.<br />

These values can also be<br />

important for calculating<br />

payback times. The range<br />

includes meters with pulsed<br />

output for remote<br />

indication or linking into an<br />

energy management system.<br />

Kwh meters can be used for<br />

local metering or monitoring<br />

of power consumption in<br />

individual machines.<br />

Part References<br />

Single phase direct measure<br />

EC050 EC051 EC110 EC111 EC112 EC120 EC121<br />

Accuracy acc IEC1036 Class 1 (1%) 0.02 to 32A~ Class 2 (2%) 0.32 to 32A~ Class 2 (2%)<br />

I max 32A ~ direct 32A ~ direct C.T. 100 / 5A<br />

Network Single phase 230V ~ 50Hz Single phase 230V~ 50 / 60Hz<br />

Counter<br />

Total without reset<br />

Total<br />

without<br />

reset<br />

Total + partial with reset<br />

Single phase 230V~ 50 /<br />

60Hz<br />

Total + partial with reset<br />

Width 1 mod 3 mod 3 mod<br />

Part References<br />

Three phase direct measure<br />

Three phase direct measure via CT<br />

EC310 EC311 EC320 EC321<br />

Accuracy acc IEC1036 Class 2 (2%) Class 2 (2%)<br />

I max 80A ~ direct C.T. 50 at 1500 / 5A<br />

Network<br />

Three phase Tri / 500V 50 / 60Hz<br />

with or without N<br />

3 x C.T. / 1 x C.T. 400V ~<br />

Tri / Tri + N 400V ~ 2 phase<br />

Counter Total + partial with reset Total + partial with reset<br />

Width 7 mod 4 mod<br />

EC051 - Single Phase Kwh<br />

Meter<br />

EC320 - Three Phase Kwh<br />

Meter<br />

SR300 - Current Transformer