System 8500<br />

MPS 854<br />

The System 8500 power supply program offers the Ultrastable Power Supply 854 specially<br />

designed for powering magnets in MRI applications.<br />

With this power supply we have achieved not only the ultimate regarding stability - the 0.1<br />

ppm class - but also introduced new standards regarding extremely low ripple and filtering<br />

technology.<br />

Major parts of the power supply 854 are constructed from standard modules of the system<br />

8500 power supply program. The modular concept is the industrial approach towards easy<br />

and fast service.<br />

The power supply can be delivered for either full current range or limited “window” with 1 ppm<br />

resolution. For sub ppm resolutions a separate control input port is available. The basic concept<br />

is designed for easy adaption to customer designed interfaces. The attached specifications<br />

describe the performance data of the power supply 854.<br />

If you are working in the field of MRI and have a need for ultrastable power supplies please<br />

consult Danfysik.<br />

We have the expertise in current stabilized power supplies and a continuously on-going development<br />

program will be your guarantee for a “state of the art” power supply for MRI equipment of<br />

tomorrow.<br />

The power supply features<br />

• Power range from 5-50 kW<br />

• Current range from 50 to 2000 A<br />

• 0.1 ppm stability class<br />

• Incorporates Ultrastab Current Transducer<br />

• Very low noise output<br />

• Very high immunity against EMI<br />

• Modular concept<br />

Applications<br />

• Resistive magnets for MRI<br />

• Callibration and reference current source<br />

• Ultrastable supply for spectrometers<br />

Danfysik A/S • Møllehaven 31 • DK-4040 Jyllinge • Denmark<br />

Tel. +45 4679 0000 • Fax +45 4679 0001 • danfysik@danfysik.dk • www.danfysik.com


Specifications<br />

DC Output ratings<br />

Power range<br />

Standard current range<br />

Voltage range<br />

: 5 - 50 kW<br />

: 50 - 2000 A<br />

: 5 - 200 V<br />

Performance<br />

All drift and regulation data are given for max. current output.<br />

Warm up time (cold start)<br />

Warm up time (from stand <strong>by</strong>)<br />

Drift<br />

Short term 3 min. (fwhm)<br />

Long term 8 hours (fwhm)<br />

: 60 min.<br />

: 15 min.<br />

: < 0.3 ppm<br />

: < 2 ppm<br />

Line regulation<br />

+/- 10% slow, T > 1 min. : < 0.1 ppm<br />

+/- 1% fast, T > 3 m sec. : < 0.1 ppm<br />

Load regulation<br />

+/- 10% resistance change : < 0.2 ppm<br />

Ripple<br />

AC Voltage ripple 50 - 60 Hz<br />

: < 5 mVpp<br />

300 - 360 Hz : < 15 mVpp<br />

Output filtering<br />

Filter design according to customer specifications<br />

Temperature coefficient<br />

Ambient<br />

Cooling water<br />

DC output isolation resistance<br />

Output polarity<br />

Current setting resolution<br />

either<br />

With total current range (100% window)<br />

or<br />

With window current range (6% window)<br />

Current readback resolution<br />

Standard<br />

Optional<br />

: 0.2 ppm/°C<br />

: 0.05 ppm/°C<br />

: > 1 Mohm<br />

: Unipolar<br />

: 18 bit (4 ppm)<br />

: 16 bit (15 ppm)<br />

: 8 bit (3906 ppm)<br />

: 16 bit (15 ppm)


Standard Operator Control Panel<br />

Current setting <strong>by</strong> knob control with a digital bit generator. Three resolution ranges for the control of 1/10, 1/1000, and<br />

1/100,000 per rev. of full scale.<br />

LCD display - with push-button selection of:<br />

Preset current (%)<br />

Actual current (%)<br />

Output voltage (%)<br />

Transistor passbank voltage<br />

Interlock status text string<br />

Regulation system status readback (Ready LED)<br />

Control system status readback:<br />

Polarity (LED)<br />

Local remote (LED)<br />

Local operator control panel, removeable<br />

Optional Operator Control Panel<br />

Designed according ti customer specifications<br />

Standard Computer Interface<br />

RS 232C/RS 422<br />

Optional Computer Interface<br />

IEEE-488 (GPIB)<br />

Customer specified interface<br />

Steel Cabinet<br />

Dimensions<br />

Operator Control Panel<br />

W x H x D<br />

: ≤ 12 kW, 615 x 800 x 1400 mm<br />

≤ 24 kW, 615 x 800 x 1800 mm<br />

≤ 50 kW, 1230 x 800 x 1800 mm<br />

: 19 inch x 88 x 75 mm<br />

Temperature ratings<br />

Operating<br />

Ambient : 15 to 35°C<br />

Water : 15 to 35°C<br />

Storage : -20 to 50°C<br />

Main cooling<br />

: Water<br />

FACT.Sys8500.MPS854.0605.A • Specifications are subject to change without notice.<br />

Cooling water pressure:<br />

Minimum diff.<br />

Max. absolute<br />

Test pressure<br />

Flow 5 - 50 kW<br />

AC Input<br />

Control Voltage,<br />

: 3 bar<br />

: 12 bar<br />

: 20 bar<br />

: Figures are very dependent on load conditions, window<br />

size and output power<br />

single phase, 50-60 Hz, standard : Europe 220 V (+/- 10%) & USA 115 V (+/- 10%)<br />

available on request<br />

: 110 V & 240 V<br />

Main voltage,<br />

3 phase, 3 or 4 wire, 50-60 Hz, standard : Europe 380 V (+/- 10%) & USA 480 V (+/- 10%)<br />

available on request<br />

: 208 V & 415 V & 565 V