Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - Europe<br />

1.<br />

SAFETY DATA SHEET<br />

IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE<br />

COMPANY/UNDERTAKING<br />

Product name<br />

:<br />

Product type :<br />

Emergency telephone number<br />

(with hours of operation)<br />

<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Date of issue : 16/06/2009 Version : 2<br />

Identification of the substance or preparation<br />

<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Liquid.<br />

Component : 288197<br />

Use of the<br />

: <strong>Cleaning</strong> solutions.<br />

substance/preparation<br />

Company/undertaking identification<br />

Manufacturer<br />

: <strong>Hycor</strong>, An Agilent Technologies Division<br />

Pentlands Science Park<br />

Bush Loan, Penicuik EH26 OPL<br />

United Kingdom<br />

e-mail address of person<br />

responsible for this SDS<br />

2.<br />

HAZARDS IDENTIFICATION<br />

: pdl-msds_author@agilent.com<br />

:<br />

Contact your local Poison Center<br />

Tel: +44 131 440 7111(08:00 to 16:00 GMT)<br />

Fax: +44 131 440 7112<br />

The preparation is classified as dangerous according to Directive 1999/45/EC and its amendments.<br />

Classification<br />

: C; R34<br />

Human health hazards : Causes burns.<br />

See section 11 for more detailed information on health effects and symptoms.<br />

3.<br />

COMPOSITION/INFORMATION ON INGREDIENTS<br />

Substance/preparation<br />

Ingredient name<br />

:<br />

Preparation<br />

CAS<br />

number<br />

% EC number Classification<br />

Sodium hydroxide 1310-73-2 1 - 5 215-185-5 C; R35 [1] [2]<br />

Sodium hypochlorite 7681-52-9 1 - 5 231-668-3 C; R34<br />

R31<br />

N; R50<br />

[1]<br />

See section 16 for the full text of the R-phrases<br />

declared above<br />

There are no ingredients or additional ingredients present which, within the current knowledge of the supplier<br />

and in the concentrations applicable, are classified as hazardous to health or the environment and hence require<br />

reporting in this section.<br />

4.<br />

FIRST AID MEASURES<br />

Inhalation :<br />

Ingestion<br />

Skin contact<br />

:<br />

:<br />

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is<br />

difficult, give oxygen. Get medical attention if adverse health effects persist or are<br />

severe.<br />

Do not induce vomiting unless directed to do so by medical personnel. Never give<br />

anything by mouth to an unconscious person. Get medical attention if adverse health<br />

effects persist or are severe.<br />

In case of contact, immediately flush skin with plenty of water for at least 15 minutes<br />

while removing contaminated clothing and shoes. Wash clothing before reuse.<br />

Clean shoes thoroughly before reuse. Get medical attention if adverse health effects<br />

persist or are severe.<br />

Date of issue/Date of revision: 16/06/2009 GB MSDS 057A.03<br />

1/7


<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Product name<br />

Company/undertaking<br />

identification<br />

Emergency telephone<br />

number<br />

Part No. : 288197<br />

4. FIRST AID MEASURES<br />

: <strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

: <strong>Hycor</strong>, An Agilent Technologies Division<br />

Pentlands Science Park<br />

Bush Loan, Penicuik EH26 OPL<br />

United Kingdom<br />

: Contact your local Poison Center<br />

Tel: +44 131 440 7111(08:00 to 16:00 GMT)<br />

Fax: +44 131 440 7112<br />

Eye contact : In case of contact, immediately flush eyes with plenty of water for at least 15 minutes.<br />

Get medical attention if adverse health effects persist or are severe.<br />

Protection of first-aiders : No action shall be taken involving any personal risk or without suitable training. If it is<br />

suspected that fumes are still present, the rescuer should wear an appropriate mask<br />

or self-contained breathing apparatus. It may be dangerous to the person providing<br />

aid to give mouth-to-mouth resuscitation. Wash contaminated clothing thoroughly<br />

with water before removing or wear gloves.<br />

Notes to physician<br />

Specific treatments<br />

:<br />

:<br />

No specific treatment. Treat symptomatically. Contact poison treatment specialist<br />

immediately if large quantities have been ingested or inhaled.<br />

Not available.<br />

See section 11 for more detailed information on health effects and symptoms.<br />

5.<br />

FIRE-FIGHTING MEASURES<br />

Extinguishing media<br />

Suitable :<br />

Not suitable :<br />

Hazardous combustion :<br />

products<br />

Special protective<br />

equipment for fire-fighters<br />

6. ACCIDENTAL RELEASE MEASURES<br />

Personal precautions<br />

Environmental precautions<br />

Small spill :<br />

:<br />

:<br />

Use an extinguishing agent suitable for the surrounding fire.<br />

Not applicable.<br />

Decomposition products may include the following materials:<br />

halogenated compounds<br />

metal oxide/oxides<br />

Fire-fighters should wear appropriate protective equipment and self-contained<br />

breathing apparatus (SCBA) with a full face-piece operated in positive pressure<br />

mode.<br />

: No action shall be taken involving any personal risk or without suitable training.<br />

Evacuate surrounding areas. Keep unnecessary and unprotected personnel from<br />

entering. Do not touch or walk through spilt material. Avoid breathing vapour or mist.<br />

Provide adequate ventilation. Wear appropriate respirator when ventilation is<br />

inadequate. Put on appropriate personal protective equipment (see section 8).<br />

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains<br />

and sewers. Inform the relevant authorities if the product has caused environmental<br />

pollution (sewers, waterways, soil or air).<br />

Stop leak if without risk. Move containers from spill area. Dilute with water and mop<br />

up if water-soluble or absorb with an inert dry material and place in an appropriate<br />

waste disposal container. Dispose of via a licensed waste disposal contractor.<br />

7.<br />

HANDLING AND STORAGE<br />

Handling<br />

Storage<br />

Packaging materials<br />

Recommended<br />

Specific uses<br />

:<br />

:<br />

Do not get in eyes, on skin or on clothing. Keep container closed. Use only with<br />

adequate ventilation. Do not breathe vapour or mist. Wash thoroughly after handling.<br />

Storage temperature: 2 to 8°C (35.6 to 46.4°F). Store in accordance with local<br />

regulations. Store in original container protected from direct sunlight in a dry, cool and<br />

well-ventilated area, away from incompatible materials (see section 10) and food and<br />

drink. Separate from acids. Keep container tightly closed and sealed until ready for<br />

use. Containers that have been opened must be carefully resealed and kept upright<br />

to prevent leakage. Do not store in unlabelled containers. Use appropriate<br />

containment to avoid environmental contamination.<br />

: Use original container.<br />

: <strong>Cleaning</strong> solutions.<br />

Date of issue/Date of revision: 16/06/2009 GB MSDS 057A.03<br />

2/7


<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Product name<br />

Company/undertaking<br />

identification<br />

Emergency telephone<br />

number<br />

Part No. : 288197<br />

Exposure limit values<br />

: <strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

: <strong>Hycor</strong>, An Agilent Technologies Division<br />

Pentlands Science Park<br />

Bush Loan, Penicuik EH26 OPL<br />

United Kingdom<br />

: Contact your local Poison Center<br />

Tel: +44 131 440 7111(08:00 to 16:00 GMT)<br />

Fax: +44 131 440 7112<br />

8. EXPOSURE CONTROLS/PERSONAL PROTECTION<br />

Ingredient name<br />

Occupational exposure limits<br />

Sodium hydroxide ACGIH TLV (United States, 1/2008).<br />

C: 2 mg/m³<br />

Recommended monitoring<br />

procedures<br />

Exposure controls<br />

Occupational exposure<br />

controls<br />

Hygiene measures :<br />

Respiratory protection :<br />

Hand protection<br />

Eye protection<br />

Skin protection<br />

Environmental exposure<br />

controls<br />

:<br />

:<br />

:<br />

If this product contains ingredients with exposure limits, personal, workplace<br />

atmosphere or biological monitoring may be required to determine the effectiveness<br />

of the ventilation or other control measures and/or the necessity to use respiratory<br />

protective equipment. Reference should be made to European Standard EN 689 for<br />

methods for the assessment of exposure by inhalation to chemical agents and<br />

national guidance documents for methods for the determination of hazardous<br />

substances.<br />

: If user operations generate dust, fumes, gas, vapour or mist, use process enclosures,<br />

local exhaust ventilation or other engineering controls to keep worker exposure to<br />

airborne contaminants below any recommended or statutory limits.<br />

Wash hands, forearms and face thoroughly after handling chemical products, before<br />

eating, smoking and using the lavatory and at the end of the working period.<br />

Appropriate techniques should be used to remove potentially contaminated clothing.<br />

Wash contaminated clothing before reusing. Ensure that eyewash stations and safety<br />

showers are close to the workstation location.<br />

Use a properly fitted, air-purifying or air-fed respirator complying with an approved<br />

standard if a risk assessment indicates this is necessary. Respirator selection must<br />

be based on known or anticipated exposure levels, the hazards of the product and the<br />

safe working limits of the selected respirator.<br />

Chemical-resistant, impervious gloves complying with an approved standard should<br />

be worn at all times when handling chemical products if a risk assessment indicates<br />

this is necessary.<br />

Safety eyewear complying with an approved standard should be used when a risk<br />

assessment indicates this is necessary to avoid exposure to liquid splashes, mists,<br />

gases or dusts.<br />

: Personal protective equipment for the body should be selected based on the task<br />

being performed and the risks involved and should be approved by a specialist before<br />

handling this product.<br />

: Emissions from ventilation or work process equipment should be checked to ensure<br />

they comply with the requirements of environmental protection legislation. In some<br />

cases, fume scrubbers, filters or engineering modifications to the process equipment<br />

will be necessary to reduce emissions to acceptable levels.<br />

9.<br />

PHYSICAL AND CHEMICAL PROPERTIES<br />

General information<br />

Appearance<br />

Physical state<br />

Colour<br />

Solubility<br />

Liquid.<br />

Clear.<br />

Important health, safety and environmental information<br />

pH<br />

: 12 to 14 [Basic.]<br />

:<br />

:<br />

:<br />

Easily soluble in the following materials: cold water and hot water.<br />

Date of issue/Date of revision: 16/06/2009 GB MSDS 057A.03<br />

3/7


<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Product name<br />

Company/undertaking<br />

identification<br />

Emergency telephone<br />

number<br />

Part No. : 288197<br />

: <strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

: <strong>Hycor</strong>, An Agilent Technologies Division<br />

Pentlands Science Park<br />

Bush Loan, Penicuik EH26 OPL<br />

United Kingdom<br />

: Contact your local Poison Center<br />

Tel: +44 131 440 7111(08:00 to 16:00 GMT)<br />

Fax: +44 131 440 7112<br />

10. STABILITY AND REACTIVITY<br />

Stability<br />

Conditions to avoid :<br />

Materials to avoid :<br />

Hazardous decomposition<br />

products<br />

:<br />

:<br />

The product is stable. Under normal conditions of storage and use, hazardous<br />

polymerisation will not occur.<br />

No specific data.<br />

Reactive or incompatible with the following materials: organic materials, acids and<br />

moisture.<br />

Slightly reactive or incompatible with the following materials: metals.<br />

Under normal conditions of storage and use, hazardous decomposition products<br />

should not be produced.<br />

11. TOXICOLOGICAL INFORMATION<br />

Potential acute health effects<br />

Inhalation<br />

Ingestion<br />

Skin contact<br />

Eye contact<br />

Potential chronic health effects<br />

Chronic toxicity<br />

Chronic effects :<br />

Carcinogenicity :<br />

: May give off gas, vapor or dust that is very irritating or corrosive to the respiratory<br />

system.<br />

: May cause burns to mouth, throat and stomach.<br />

: Corrosive to the skin. Causes burns. May cause sensitisation by skin contact.<br />

: Corrosive to eyes. Causes burns.<br />

Acute toxicity<br />

Product/ingredient name Result Species Dose Exposure<br />

Sodium hypochlorite LD50 Oral Rat 5000 mg/kg -<br />

Conclusion/Summary<br />

Conclusion/Summary<br />

Carcinogenicity<br />

Conclusion/Summary<br />

Mutagenicity<br />

Conclusion/Summary<br />

Teratogenicity<br />

Conclusion/Summary<br />

Reproductive toxicity<br />

Conclusion/Summary<br />

: Not available.<br />

: Not available.<br />

: Not available.<br />

: Not available.<br />

: Not available.<br />

: Not available.<br />

No known significant effects or critical hazards.<br />

No known significant effects or critical hazards.<br />

Mutagenicity : No known significant effects or critical hazards.<br />

Teratogenicity : No known significant effects or critical hazards.<br />

Developmental effects : No known significant effects or critical hazards.<br />

Fertility effects<br />

: No known significant effects or critical hazards.<br />

Over-exposure signs/symptoms<br />

Inhalation<br />

: No specific data.<br />

Ingestion<br />

Skin<br />

:<br />

:<br />

Adverse symptoms may include the following:<br />

stomach pains<br />

Adverse symptoms may include the following:<br />

pain or irritation<br />

redness<br />

blistering may occur<br />

Date of issue/Date of revision: 16/06/2009 GB MSDS 057A.03<br />

4/7


<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Product name<br />

Company/undertaking<br />

identification<br />

Emergency telephone<br />

number<br />

Part No. : 288197<br />

: <strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

: <strong>Hycor</strong>, An Agilent Technologies Division<br />

Pentlands Science Park<br />

Bush Loan, Penicuik EH26 OPL<br />

United Kingdom<br />

: Contact your local Poison Center<br />

Tel: +44 131 440 7111(08:00 to 16:00 GMT)<br />

Fax: +44 131 440 7112<br />

11. TOXICOLOGICAL INFORMATION<br />

Eyes<br />

Target organs<br />

12. ECOLOGICAL INFORMATION<br />

Environmental effects<br />

Biodegradability<br />

Other adverse effects<br />

: Adverse symptoms may include the following:<br />

pain<br />

watering<br />

redness<br />

:<br />

Contains material which may cause damage to the following organs: lungs, upper<br />

respiratory tract, skin, eye, lens or cornea.<br />

Aquatic ecotoxicity<br />

Product/ingredient name Test Result<br />

Species<br />

Sodium hydroxide - Acute EC50<br />

40.38 to 47.13<br />

mg/L Fresh water<br />

Daphnia<br />

- Acute LC50 Fish<br />

125000 ug/L<br />

Fresh water<br />

Sodium hypochlorite - Acute EC50 0.04 Daphnia<br />

to 0.044 ppm<br />

Fresh water<br />

- Acute LC50 32 to Daphnia<br />

36 ug/L Fresh<br />

water<br />

- Acute LC50 23 to Fish<br />

52 ug/L Marine<br />

water<br />

Conclusion/Summary<br />

: Not available.<br />

13. DISPOSAL CONSIDERATIONS<br />

Methods of disposal<br />

Hazardous waste :<br />

14. TRANSPORT INFORMATION<br />

: May be harmful to the environment if released in large quantities.<br />

: No known significant effects or critical hazards.<br />

:<br />

Exposure<br />

48 hours<br />

96 hours<br />

48 hours<br />

48 hours<br />

96 hours<br />

The generation of waste should be avoided or minimised wherever possible. Dispose<br />

of surplus and non-recyclable products via a licensed waste disposal contractor.<br />

Disposal of this product, solutions and any by-products should at all times comply with<br />

the requirements of environmental protection and waste disposal legislation and any<br />

regional local authority requirements. Avoid dispersal of spilt material and runoff and<br />

contact with soil, waterways, drains and sewers.<br />

The classification of the product may meet the criteria for a hazardous waste.<br />

International transport regulations<br />

Regulatory<br />

information<br />

ADR Class<br />

UN number Proper shipping name Classes PG* Label<br />

UN3266<br />

CORROSIVE LIQUID,<br />

BASIC, INORGANIC,<br />

N.O.S. (Sodium<br />

hydroxide, Sodium<br />

hypochlorite)<br />

8 II<br />

Additional<br />

information<br />

Hazard identification<br />

number<br />

80<br />

Limited quantity<br />

LQ22<br />

CEFIC Tremcard<br />

Date of issue/Date of revision: 16/06/2009 GB MSDS 057A.03<br />

5/7


<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Product name<br />

Company/undertaking<br />

identification<br />

Emergency telephone<br />

number<br />

Part No. : 288197<br />

: <strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

: <strong>Hycor</strong>, An Agilent Technologies Division<br />

Pentlands Science Park<br />

Bush Loan, Penicuik EH26 OPL<br />

United Kingdom<br />

: Contact your local Poison Center<br />

Tel: +44 131 440 7111(08:00 to 16:00 GMT)<br />

Fax: +44 131 440 7112<br />

14. TRANSPORT INFORMATION<br />

80GC5-II+III<br />

IMDG Class<br />

UN3266<br />

CORROSIVE LIQUID,<br />

BASIC, INORGANIC,<br />

N.O.S. (Sodium<br />

hydroxide, Sodium<br />

hypochlorite)<br />

8 II<br />

Emergency<br />

schedules (EmS)<br />

F-A, S-B<br />

IATA Class UN3266 Corrosive liquid, basic,<br />

inorganic, n.o.s.<br />

(Sodium hydroxide,<br />

Sodium hypochlorite)<br />

8 II<br />

Passenger and Cargo<br />

Aircraft<br />

Quantity limitation: 1 L<br />

Packaging instructions:<br />

808<br />

Cargo Aircraft Only<br />

Quantity limitation: 30 L<br />

Packaging instructions:<br />

812<br />

Limited Quantities -<br />

Passenger Aircraft<br />

Quantity limitation: 0.5<br />

L<br />

Packaging instructions:<br />

Y808<br />

PG* : Packing group<br />

15. REGULATORY INFORMATION<br />

EU regulations<br />

Classification and labeling have been determined according to EU Directives 67/548/EEC and 1999/45/EC<br />

(including amendments) and take into account the intended product use.<br />

Hazard symbol or symbols<br />

Risk phrases<br />

Safety phrases<br />

Contains<br />

Product use<br />

Europe inventory<br />

16. OTHER INFORMATION<br />

Full text of R-phrases<br />

referred to in sections 2 and<br />

3 - Europe<br />

Full text of classifications<br />

referred to in sections 2 and<br />

3 - Europe<br />

History<br />

Date of issue / Date of<br />

revision<br />

:<br />

:<br />

:<br />

:<br />

C - Corrosive<br />

R34- Causes burns.<br />

S26- In case of contact with eyes, rinse immediately with plenty of water and seek<br />

medical advice.<br />

S36/37/39- Wear suitable protective clothing, gloves and eye/face protection.<br />

S45- In case of accident or if you feel unwell, seek medical advice immediately (show<br />

the label where possible).<br />

Sodium hydroxide 215-185-5<br />

: Industrial applications.<br />

: Europe inventory: All components are listed or exempted.<br />

:<br />

:<br />

:<br />

R34- Causes burns.<br />

R35- Causes severe burns.<br />

R31- Contact with acids liberates toxic gas.<br />

R50- Very toxic to aquatic organisms.<br />

C - Corrosive<br />

N - Dangerous for the environment<br />

16/06/2009<br />

Date of issue/Date of revision: 16/06/2009 GB MSDS 057A.03<br />

6/7


<strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

Product name<br />

Company/undertaking<br />

identification<br />

Emergency telephone<br />

number<br />

Part No. : 288197<br />

16. OTHER INFORMATION<br />

Date of previous issue<br />

Version<br />

: <strong>HYTEC</strong> <strong>Probe</strong> <strong>Cleaning</strong> <strong>Solution</strong><br />

: <strong>Hycor</strong>, An Agilent Technologies Division<br />

Pentlands Science Park<br />

Bush Loan, Penicuik EH26 OPL<br />

United Kingdom<br />

: Contact your local Poison Center<br />

Tel: +44 131 440 7111(08:00 to 16:00 GMT)<br />

Fax: +44 131 440 7112<br />

: 22/01/2009<br />

: 2<br />

Notice to reader<br />

DISCLAIMER: This information is based on our present state of knowledge. It should not therefore be construed<br />

as guaranteeing the suitability of the Product for a particular application.<br />

Date of issue/Date of revision: 16/06/2009 GB MSDS 057A.03<br />

7/7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!