ATEX<br />

Static Electricity<br />

The pump needs to be sufficiently grounded so as to avoid any electrostatic<br />

charging. This is attained when properly connecting the electric ground conductor<br />

to the motor. During normal operation no hazardous generation of<br />

charges will occur on the plastic coupling or the fan (for further information<br />

relating to the hazards caused by static electricity, see CENELEC report<br />

CLC/TR 50404: 2003 Electrostatics - Code of practice for the avoidance of<br />

hazards due to static electricity).<br />

Only original <strong>Leybold</strong> oil filters and gas inlet filters must be used since these<br />

have been designed such that proper connection to ground is ensured. Dust<br />

on the surfaces must only be removed using a moist piece of cloth so as to<br />

exclude the possibility of generating sparks.<br />

Chemical Reactions<br />

The pump must not be used in connection with reactive or corrosive gases,<br />

which might result in an exothermal chemical reaction.<br />

Additional Safety Measures<br />

Overheating the pump can give rise to temperatures which exceed the maximum<br />

permitted surface temperature.<br />

In order to prevent overheating, installation and maintenance need to be<br />

done in accordance with the information provided in these Operating<br />

Instructions. Especially the correct oil level needs to be maintained.<br />

The oil must be exchanged within the recommended interval or earlier if contaminated<br />

by the process gas.<br />

Additional Maintenance Requirements<br />

In those cases where dust can deposit itself on the pump or the motor surfaces,<br />

measures must be introduced which ensure that such deposits are<br />

removed on a regular basis.<br />

In order to ensure that the defined safety level is complied with, use only original<br />

<strong>Leybold</strong> spare parts.<br />

In addition to the maintenance work described in the Operating Instructions<br />

every 15.000 operating hours or every three years a complete refurbishment<br />

of the pump including a replacement of the bearings and the couplings<br />

should be scheduled.<br />