1.3.1 Motor Related Data<br />

Part No. LN-No. 1 ph or 3 ph Nominal voltage (V) Frequency Voltage Power (kW) Nominal (A) Size Region<br />

(Hz) ± 5% range (V) current<br />

140 220 E 110 002 715 95-120 / 190-252 50/60 +/- 5% 0.55 13.0 / 7.5 90 World<br />

1 ph 95-120 / 190-242 0.66 10.0 / 5.0<br />

140 231,<br />

140 232, 140 233, E 110 002 716 218-242 50/60 +/- 5% 0.45/0.55 5.0 / 5.5 90 Euro<br />

140 234, 140 235 1 ph<br />

140 241 E 110 002 717 95-105 50 +/- 5% 0.55 9.5 90 Japan/US<br />

1 ph 95-120 60 +/- 5% 0.66 10.0<br />

140 221,<br />

140 222, 140 223, E 110 002 712 200-240 / 380-415 50 +/- 10% 0.55 3.1-4.0 /1.5-1.6 90 World<br />

140 224, 140 225 3 ph 200-240 / 380-460 60 +/- 10% 0.66 3.1 /1.6<br />

Related electrical equipment<br />

If the pump has been approved for use in explosion hazard areas, then all<br />

electrical equipment like motor, valves, sensors, for example, is approved for<br />

operation in these areas (the same conditions as for the pump apply).<br />

Compliance with the enclosed operating information provided by the manufacturer<br />

of the electric motor needs to be ensured. When using other<br />

motors, these must be rated as follows:<br />

<strong>Pump</strong>ing speed / m 3 16 / 25 16 / 25<br />

Frequency / Hz 50 60<br />

Speed / min 1500 1800<br />

Power / W 750 750<br />

20 130002780_002_A0 - 12/2008 - © <strong>Oerlikon</strong> <strong>Leybold</strong> <strong>Vacuum</strong>