24.01.2014 Views

Bus cables (PDF)

Bus cables (PDF)

Bus cables (PDF)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GigE<br />

TPE<br />

12,5 x d<br />

Chainflex ® CF BUS GigE<br />

● GigE cable<br />

● Ethernet special cable for mechanically heavy-duty use<br />

● Oil-resistant<br />

● Flame-retardant<br />

Especially bendingresistant<br />

fine-wire<br />

stranded conductor<br />

[ϒC]<br />

Temperature range<br />

R<br />

moved<br />

-35 °C to +70 °C, Bending radius 12,5 x d<br />

[ϒC ]<br />

Temperature range<br />

R<br />

fixed<br />

-40 °C to +70 °C, Bending radius 7,5 x d<br />

Cores and paires<br />

stranded with an<br />

especially short<br />

pitch length<br />

[V]<br />

[a]<br />

R<br />

V max.<br />

unsupported/gliding<br />

10 m/s, 6 m/s<br />

R<br />

a max. 100 m/s 2<br />

UV<br />

UV-resistant<br />

Medium<br />

V<br />

Nominal voltage<br />

30 V<br />

Testing voltage<br />

500 V<br />

Gusset-filled<br />

extruded<br />

Oil<br />

Oil-resistant (according to DIN EN 60811-2-1), bio-oil-resistant<br />

oil<br />

(according to VDMA 24568)<br />

Flame-retardant<br />

According IEC 332-1, CEI 20-35, FT1.<br />

Extremely bendingresistant,<br />

tinned<br />

copper shield<br />

Silicon-free<br />

Free from silicon which can affect paint adhesion<br />

(in compliance with PV 3.10.7 – status 1992).<br />

Conductor<br />

Fine-wire stranded conductor in especially bending-resistant<br />

version consisting of bare copper wires (according to EN 60228).<br />

Pressure extruded,<br />

flame-retard TPE<br />

blend<br />

Core insulation<br />

Mechanically high-quality PP mixture.<br />

Core stranding<br />

2 cores each stranded in pairs with short pitch lengths<br />

core pairs also stranded with short pitch lengths.<br />

Core identification Colour code in accordance with DIN 47100<br />

Inner jacket TPE mixture adapted to suit the requirements in Energy Chains ® .<br />

GigE<br />

10<br />

RoHS<br />

Overall shield Extremely bending-resistant, tinned braided copper shield.<br />

Coverage approx. 70% linear, approx. 90% optical.<br />

Outer jacket<br />

Low-adhesion mixture on the basis of TPE, especially abrasion-resistant<br />

and highly flexible, adapted to suit the requirements<br />

in Energy Chains ® .<br />

Colour: violet (similar to RAL 4001)<br />

UL/CSA Style 1589 and 21371, 30 V, 80 °C<br />

... no minimum order quantity