HYDRAULIC PUMPING UNITS WITHOUT REGULATION<br />
• Maximum operating temperature in flow branch: 160ºC<br />
• Maximum operating temperature in return branch: 110ºC.<br />
• Maximum operating temperature in safety valve: 160ºC.<br />
• Hydraulic unit <strong>for</strong> collector fields of up to 16 m 2 .<br />
• Safety valve calibration: 6 bar.<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
• Thermometer temperature range: 0-120ºC.<br />
• Flow indication range: 2-12 l/min.<br />
• Manometer scale: 0-10 bar.<br />
• Connections: 3/4”H.<br />
• Distance between branches: 95 mm.<br />
+<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />
FLOW RETURN VESSEL JOINT<br />
BRANCH BRANCH ACCESSORIES<br />
Complete Complete ST 15/6eco NO NO 70000<br />
Complete Complete ST 15/6eco NO YES 70100<br />
Note: Consult pump curves.<br />
+<br />
HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />
FLOW RETURN VESSEL JOINT<br />
BRANCH BRANCH ACCESSORIES<br />
No Complete ST 15/6eco NO NO 70020<br />
No Complete ST 15/6eco NO YES 70120<br />
Note: Consult pump curves.<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
103