07.02.2014 Views

General Catalogue Components for solar systems 2013_ENG - Orkli

General Catalogue Components for solar systems 2013_ENG - Orkli

General Catalogue Components for solar systems 2013_ENG - Orkli

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

03<br />

Solar heating<br />

<strong>systems</strong><br />

energy<br />

efficiency<br />

Compact, "ALL-IN-ONE" <strong>solar</strong> system<br />

Solar panel <strong>for</strong> swimming pools<br />

Hydraulic components<br />

Drain-Unit: dual hydraulic unit with<br />

drain back system<br />

Drain-Unit: hydraulic unit with<br />

drain-back system<br />

Hydraulic units high efficiency<br />

Hydraulic pumping units with<br />

integrated control<br />

Hydraulic pumping units without regulation<br />

Hydraulic units <strong>for</strong> major installations<br />

OKFRESH - Fresh water station<br />

Indirect heat exchange <strong>solar</strong> kit<br />

Solar dhw kit<br />

Zone valves<br />

Safety valves<br />

Flowmeters<br />

Safety groups<br />

Compensation valves<br />

Drain valves/air separators<br />

Mixing valves<br />

Controls <strong>for</strong> <strong>solar</strong> heating installations<br />

Solar expansion vessels<br />

Accessories <strong>for</strong> expansion vessels<br />

Solar heating<br />

<strong>systems</strong><br />

03


SOLAR HEATING SYSTEMS<br />

COMPACT, "ALL-IN-ONE" SOLAR SYSTEM<br />

This is an ALL-IN-ONE <strong>solar</strong> system that uses <strong>solar</strong><br />

thermal energy to heat domestic water. It integrates<br />

the absorber, the pump-circulated system, and the<br />

150l tank. It uses a PV-driven circulating pump,<br />

which means it is a fully autonomous system that<br />

does not require any external power source.<br />

COMPONENTS<br />

All you need in just a single element<br />

Inlet.<br />

1 6<br />

Pump.<br />

2 7<br />

PV panel.<br />

3 8<br />

Methacrylate cover.<br />

4 9<br />

Insulator.<br />

Valve.<br />

Outlet.<br />

Exchanger.<br />

3<br />

4<br />

10<br />

5<br />

6<br />

9<br />

7<br />

8<br />

2sqm stainless steel<br />

collector featuring a blue<br />

selective surface.<br />

5 10<br />

150 litres tank made<br />

of corrosion-resistant<br />

composite materials.<br />

2<br />

1<br />

HOW DOES IT WORK?<br />

From sunrise till water is hot.<br />

85º<br />

STAGE 1<br />

Solar radiation reaches the<br />

collector, which concentrates<br />

the heat that is then<br />

transferred to the heat<br />

transfer fluid that circulates<br />

through the system.<br />

The selective treatment and<br />

the shape of the surface, it<br />

uses a large proportion of<br />

incident radiation. As it is<br />

filled with the heat transfer<br />

fluid, it can use 100% of<br />

the surface.<br />

STAGE 2<br />

The radiation on the surface<br />

is also received on the PV<br />

panel, which generates<br />

the power that drives the<br />

circulating pump.<br />

The pump gets the hot fluid<br />

into the exchanger.<br />

STAGE 3<br />

The heat is transferred to<br />

the tank because the hot<br />

fluid passes from the pump<br />

to the exchanger.<br />

The tank will get hot<br />

whenever there is sunlight<br />

up to the top limit set at<br />

85ºC.<br />

84<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


WHERE IS IT INSTALLED?<br />

It can be adapted to meet different installation needs<br />

The ALL-IN-ONE <strong>solar</strong> system can be placed anywhere requiring domestic hot water (homes, campsites,<br />

community vegetable gardens, country homes and hotels). The ALL-IN-ONE <strong>solar</strong> system can be placed in<br />

a wide variety of places, from a pitched roof (either built-in or not) to a flat surface, a garden or a wall.<br />

03<br />

Solar heating<br />

<strong>systems</strong><br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 85


SOLAR HEATING SYSTEMS<br />

ADVANTAGES<br />

15% CHEAPER<br />

THAN OTHER SYSTEMS OF THE MARKET<br />

Less components<br />

means<br />

less time to install<br />

less final price<br />

and more m 2 available at home.<br />

COMPONENTS TO INSTALL<br />

A SOLAR SYSTEM<br />

COMPONENTS<br />

SYSTEM<br />

DRAIN BACK<br />

SYSTEM<br />

OKSOL SYSTEM<br />

ORKLI ALL-IN-ONE<br />

MATERIAL<br />

Collector<br />

Hydraulic group<br />

Tank<br />

Solar tube<br />

Secondary tube<br />

ACCESSORIES<br />

ELECTRIC<br />

INSTALLATION<br />

Structure 45º<br />

Expansion tank<br />

Sanitary <strong>solar</strong> fluid<br />

Drain valves<br />

Electrical legalization<br />

Material and labor<br />

INSTALLATION TIME 25,5 h. 15,5 h. 9,5 h.<br />

COMPONENT SYSTEM<br />

OKSOL SYSTEM<br />

86 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


• Pump powered by photovoltaic cell.<br />

• Storage capacity: 150 litres.<br />

• Useful collection surface area: 1,95 m 2 .<br />

• Heat exchanger surface: 0,29 m 2 .<br />

• External dimensions:<br />

- Length: 2029 mm.<br />

- Width: 1020 mm.<br />

- Depth: 250 mm.<br />

- Empty weight including tank: 80 kg.<br />

• Structure on floor or flat terrace, structure, sloping roof top structure and wall structure, under request.<br />

03<br />

Solar heating<br />

<strong>systems</strong><br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Solar collector with integrated tank OKSOL-150 1<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 87


SOLAR HEATING SYSTEMS<br />

STRUCTURES<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Wall structure V-00396 1<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Roof-integrated structure V-00397 1<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Non-per<strong>for</strong>ating anchor kit V-01036 6<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Sloping roof top structure V-00395 1<br />

(Non-per<strong>for</strong>atin anchor kit not included)<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Structure on floor or flat terrace (legs) V-01035 1<br />

88 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


ACCESSORIES<br />

Protective awning<br />

Centrifugal pump<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Centrifugal pump V-01981 1<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Protective awning V-02521 1<br />

Non-return valve<br />

3-bar safety valve<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Non-return valve V-01982 1<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3-bar safety valve V-01983 1<br />

P+5 safety valve Heat-carrying fluid (16 litre tank)<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

P+T safety valve V-01984 1<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Heat-carrying fluid V-01985 1<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

89


SOLAR HEATING SYSTEMS<br />

SOLAR PANEL FOR SWIMMING POOLS<br />

Heated pool water almost all year round. An efficient, af<strong>for</strong>dable alternative.<br />

This is one of the most technically efficient, cost-effective applications <strong>for</strong> swimming pool<br />

water heating. Your pool season is extended by 2-3 months with this <strong>solar</strong> panel system,<br />

as the process involves heating large amounts of water to a relatively low temperature. A<br />

solution using <strong>solar</strong> power: a clean, free, inexhaustible power source to keep your pool water<br />

at just the right temperature.<br />

FEATURES<br />

Stainless steel <strong>solar</strong> collector.<br />

Collection surface area 2 m² and weight 15 Kg.<br />

3 hydraulic connections (Ø ¾) <strong>for</strong> any<br />

installation configuration.<br />

Dimensions 2000 x 1000 x 18.<br />

Sold in batches of 4 units.<br />

Panels guaranteed <strong>for</strong> 5 years.<br />

2000<br />

ISO G 3/4"<br />

1000<br />

90 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


HOW DOES IT WORK?<br />

03<br />

Solar heating<br />

<strong>systems</strong><br />

ADVANTAGES<br />

It extends the pool season by 2-3 months (at temperatures over 25ºC)<br />

The system is compatible with other auxiliary pool heating <strong>systems</strong>.<br />

Excess heat can be used <strong>for</strong> domestic hot water production, via a heat exchanger.<br />

Adaptable to all kinds of pool. The system is connected to the existing filter circuit using a heat exchanger<br />

or directly, depending on the type of filtering.<br />

Totally controllable via a central control unit. It enables the pool temperature to be controlled and the<br />

<strong>solar</strong> collector system to be switched off when the water reaches the desired temperature.<br />

A smaller heating surface area is required compared to other <strong>systems</strong> on the market.<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 91


SOLAR HEATING SYSTEMS<br />

SOLAR PANEL FOR SWIMMING POOLS<br />

• Absorber type: Stainless steel absorber with selective coating.<br />

• Dimensions: Length 2000 mm ± 1 mm, width 1000 mm ± 0.5 mm.<br />

• Surface: 2 m 2 .<br />

• Aperture surface: 1.95 m 2 .<br />

• Weight: 19 kg.<br />

• Interior volume: 32 litres.<br />

• Connection openings ISO G 3/4”.<br />

• Pressure control resistance: 6 bar.<br />

• Maximum working pressure: 3 bar.<br />

• Nominal flow: 90 l/h m 2 .<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Solar panel <strong>for</strong> swimming pools V-01850 1<br />

HYDRAULIC CHARACTERISTICS<br />

Pressure drop<br />

400<br />

350<br />

300<br />

250<br />

mmca<br />

200<br />

150<br />

100<br />

50<br />

0<br />

0 1 2<br />

3 4<br />

l/min<br />

92<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


ALL THE HYDRAULIC COMPONENTS<br />

REQUIRED FOR A SOLAR INSTALLATION<br />

Air vent valve<br />

with ball valve<br />

Solar hydraulic pump units<br />

(or Drain-back system)<br />

Collectors field<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

Solar<br />

expansion<br />

vessels<br />

Support system<br />

Boiler<br />

Swimming pool<br />

Zone<br />

valve<br />

Drain valves<br />

with air<br />

separators<br />

Solar DHW<br />

kit<br />

Hot water tank<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

93


SOLAR HEATING SYSTEMS<br />

DRAIN UNIT:<br />

HYDRAULIC UNIT WITH DRAIN-BACK SYSTEM<br />

A solution to prevent<br />

overheating and<br />

freezing.<br />

ADVANTAGES<br />

BIGGER SAVINGS simply select all the<br />

components you need<br />

COMPATIBLE with all the collectors, heat<br />

exchangers and regulators on the market<br />

For INSTALLATIONS with a larger number<br />

of collectors than other market alternatives<br />

HOW DOES IT WORK?<br />

System off -<br />

Collectors empty<br />

OFF<br />

Maximum<br />

temperatures<br />

OFF<br />

System off -<br />

Collectors empty<br />

(no danger of vaporisation)<br />

OFF<br />

OFF<br />

ON<br />

ON<br />

System start-up -<br />

Filling circuit<br />

temperatures -0ºC<br />

System off -<br />

Collectors empty<br />

(no danger of freezing)<br />

OFF<br />

OFF<br />

ON<br />

System running -<br />

Forced circulation<br />

OFF<br />

94<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


SELECTION GUIDE<br />

The Drain-Unit selection is determined by the height of the installation. Bear in mind the difference in height<br />

between the top of the collector array and the bottom part of the Drain-Unit positioning.<br />

N.b.: less pump power required if the Drain-Unit is installed just above the collector field.<br />

HEIGHT OF INSTALLATION* 3-5 metres 5-10 metres 10-15 metres 3- 10 metres 10-15 metres<br />

RECOMMENDED MODEL 6-metre pumps 6-metre + 6-metre pumps 11 + 6-metre pumps 11-metre pumps 11 + 6-metre pumps<br />

ECONOMY MODEL 6-metre pumps 11-metre pumps Unfit 11-metre pumps 11 + 6-metre pumps<br />

NUMBER OF COLLECTORS** 1-5 1-4 1-4 4-10 4-8<br />

*Height from the top of the <strong>solar</strong> collectors to the lowest point of the drain unit<br />

**Calculated <strong>for</strong> a collector capacity of 1.25 litres and tube 15 mm.<br />

It can be used with installations that have a larger number of collectors than other market alternatives.<br />

The volume of the circuit above the drain unit must not exceed 8 litres of working volume of the air<br />

separator in drain units with a single tank (or 16 litres <strong>for</strong> drain units with 2 tanks).<br />

Volume calculation in upper part: Volume Nº of collectors Volume of fluid<br />

= +<br />

+<br />

in collector<br />

Volume<br />

of pipes<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

DRAIN UNIT WITH INTEGRATED REGULATION<br />

• Maximum operating temperature: 110ºC.<br />

• Maximum peaks: 130ºC.<br />

• Safety valve calibration: 3 bar.<br />

• Flow indication range: 2-12 litres/min.<br />

• Maximum separation volume: 8 litres.<br />

• Connections: bicone nut <strong>for</strong> a Cu15mm o ½”M pipe.<br />

• Control options with pre-connections made.<br />

• Consult <strong>for</strong> adaptability to other regulations.<br />

TWO 6-metre PUMPS<br />

PUMPS REGULATION ARTICLE €<br />

6 metres + 6 metres Basic (3 sensors, 1 relay) 74110BA<br />

6 metres + 6 metres Vision (6 sensors, 3 relays) 74110VI<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

95


SOLAR HEATING SYSTEMS<br />

DRAIN UNIT WITH INTEGRATED REGULATION<br />

ONE 11-metre PUMP<br />

PUMPS REGULATION ARTICLE €<br />

11 metres Basic (3 sensors, 1 relay) 74200BA<br />

11 metres Vision (6 sensors, 3 relays) 74200VI<br />

ONE 6-metre PUMP<br />

PUMPS REGULATION ARTICLE €<br />

6 metres Basic (3 sensors, 1 relay) 74100BA<br />

6 metres Vision (6 sensors, 3 relays) 74100VI<br />

96 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


DRAIN UNIT WITH INTEGRATED REGULATION<br />

TWO 11+6-metre PUMPS<br />

03<br />

Solar heating<br />

<strong>systems</strong><br />

PUMPS REGULATION ARTICLE €<br />

11 metres + 6 metres Basic (3 sensors, 1 relay) 74210BA<br />

11 metres + 6 metres Vision (6 sensors, 3 relays) 74210VI<br />

DRAIN UNIT WITHOUT REGULATION<br />

• Maximum operating temperature: 110ºC.<br />

• Maximum peaks: 130ºC.<br />

• Safety valve calibration: 3 bar.<br />

• Flow indication range: 2-12 litres/min.<br />

• Maximum separation volume: 8 litres.<br />

• Connections: bicone nut <strong>for</strong> a Cu15mm o ½”M pipe.<br />

• Consult <strong>for</strong> adaptability to other regulations.<br />

• Recommended characteristics:<br />

• Solar regulation with a differential relay.<br />

• Maximum temperature function of collector 110ºC. (recommended).<br />

• Difference in activation temperature 10-15ºC.(recommended).<br />

PUMPS REGULATION ARTICLE €<br />

6 metres + 6 metres - 74110<br />

11 metres - 74200<br />

6 metres - 74100<br />

11 metres + 6 metres - 74210<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

97


SOLAR HEATING SYSTEMS<br />

For installations with twice as many <strong>solar</strong> collectors as the existing<br />

system.<br />

DRAIN UNIT: NEW HYDRAULIC UNIT WITH DRAIN BACK SYSTEM<br />

• Maximum operating temperature: 110ºC.<br />

• Maximum peaks: 130ºC.<br />

• Safety valve calibration: 3 bar.<br />

• Flow indication range: 2-12 litres/min.<br />

• Maximum separation volume: 16 litres.<br />

• Connections: bicone nut <strong>for</strong> a Cu15mm o ½”M pipe.<br />

• Control options with pre-connections made.<br />

• Consult <strong>for</strong> adaptability to other regulations.<br />

ONE 11-metre PUMPS<br />

• In case of no regulation options, the regulation must comply with<br />

the following characteristics:<br />

- Solar regulation with a differential relay.<br />

- Maximum temperature function of collector 110ºC.<br />

(recommended).<br />

- Difference in activation temperature 10-15ºC.(recommended).<br />

PUMPS REGULATION ARTICLE €<br />

11 metres Basic (3 sensors, 1 relay) 74200BADO<br />

11 metres Vision (6 sensors, 3 relays) 74200VIDO<br />

11 metres NO 74200DO<br />

98 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


DRAIN UNIT: NEW HYDRAULIC UNIT WITH DRAIN BACK SYSTEM<br />

TWO 11+6-metre PUMPS<br />

03<br />

Solar heating<br />

<strong>systems</strong><br />

PUMPS REGULATION ARTICLE €<br />

11 metres + 6 metres Basic (3 sensors, 1 relay) 74210BADO<br />

11 metres + 6 metres Vision (6 sensors, 3 relays) 74210VIDO<br />

11 metres + 6 metres NO 74210DO<br />

Drainback tank extension kit<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Tank V-00625 1<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 99


SOLAR HEATING SYSTEMS<br />

HYDRAULIC UNITS HIGH EFFICIENCY<br />

The optimum efficiency of the sun as a power source<br />

The Solar<strong>Orkli</strong> line opts <strong>for</strong> technologically innovative<br />

products contributing to smarter, more sustainable<br />

consumption of renewable energies. An example are<br />

the high-efficiency <strong>solar</strong> hydraulic units, which include<br />

components that can increase energy efficiency by<br />

almost 50%.<br />

100 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


HYDRAULIC UNITS HIGH EFFICIENCY<br />

• Maximum working temperature in flow branch: 120ºC.<br />

• Maximum working temperature in return branch: 100ºC.<br />

• Maximum working temperature of safety valve: 160ºC.<br />

• Safety valve calibration: 6 bar.<br />

• Thermometer temperature range: 0-120ºC.<br />

• Flow meter indication range: 2-12 l/min. (visual flow meter);<br />

2-40 l/min. (electronic).<br />

• High energy efficiency pump with cabling preconnection.<br />

• External PWM pump modulation.<br />

• Hydraulic unit <strong>for</strong> <strong>solar</strong> collector fields up to 16 m 2 .<br />

• Consult <strong>for</strong> adaptability to other regulations.<br />

• Pump consumption range: 4-60W.<br />

• Energy count option on models with electronic sensors.<br />

• Manometer scale: 0-10 bar.<br />

• Connections: 3/4"H.<br />

• Branch distance: 95 mm.<br />

• Regulation with connections made.<br />

• EPP insulation.<br />

+<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

HYDRAULICS PUMP CLIMATE CONTROL ELECTRONIC FLOW EXPANSION ARTICLE €<br />

BASIC HE TEMPERATURE AND VESSEL JOINT<br />

PRESSURE SENSORS ACCESSORIES<br />

Complete Yonos Para ST 15/7 PWM YES YES YES 73140BAHE<br />

Complete Yonos Para ST 15/7 PWM YES NO YES 73100BAHE<br />

Complete Yonos Para ST 15/7 PWM YES YES NO 73040BAHE<br />

Complete Yonos Para ST 15/7 PWM YES NO NO 73000BAHE<br />

Complete Yonos Para ST 15/7 PWM NO YES YES 73140HE<br />

Complete Yonos Para ST 15/7 PWM NO NO YES 73100HE<br />

Complete Yonos Para ST 15/7 PWM NO YES NO 73040HE<br />

Complete Yonos Para ST 15/7 PWM NO NO NO 73000HE<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 101


SOLAR HEATING SYSTEMS<br />

HYDRAULIC PUMPING UNITS WITH INTEGRATED CONTROL<br />

• Maximum operating temperature in flow branch: 160ºC<br />

• Flow indication range: 2-12 l/min.<br />

• Maximum operating temperature in return branch: 110ºC.<br />

• Manometer scale: 0-10 bar.<br />

• Maximum operating temperature in safety valve: 160ºC.<br />

• Connections: 3/4”H.<br />

• Hydraulic unit <strong>for</strong> collector fields of up to 16 m 2 .<br />

• Distance between branches: 95 mm.<br />

• Safety valve calibration: 6 bar<br />

• Control with connections made.<br />

• Thermometer temperature range: 0-120ºC.<br />

• Consult <strong>for</strong> adaptability to other regulations.<br />

+<br />

HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />

FLOW RETURN VESSEL JOINT<br />

BRANCH BRANCH ACCESSORIES<br />

Complete Complete ST 15/6eco Basic (3 inputs, 1 relay) NO 70000BA<br />

Complete Complete ST 15/6eco Vision (6 inputs, 3 relays) NO 70000VI<br />

Complete Complete ST 15/6eco Basic (3 inputs, 1 relay) YES 70100BA<br />

Complete Complete ST 15/6eco Vision (6 inputs, 3 relay) YES 70100VI<br />

Note: Consult pump curves.<br />

+<br />

Note: Consult pump curves.<br />

HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />

FLOW RETURN VESSEL JOINT<br />

BRANCH BRANCH ACCESSORIES<br />

NO Complete ST 15/6eco Basic (3 inputs, 1 relay) NO 70020BA<br />

NO Complete ST 15/6eco Vision (6 inputs, 3 relays) NO 70020VI<br />

NO Complete ST 15/6eco Basic (3 inputs, 1 relay) YES 70120BA<br />

NO Complete ST 15/6eco Vision (6 inputs, 3 relays) YES 70120VI<br />

102<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


HYDRAULIC PUMPING UNITS WITHOUT REGULATION<br />

• Maximum operating temperature in flow branch: 160ºC<br />

• Maximum operating temperature in return branch: 110ºC.<br />

• Maximum operating temperature in safety valve: 160ºC.<br />

• Hydraulic unit <strong>for</strong> collector fields of up to 16 m 2 .<br />

• Safety valve calibration: 6 bar.<br />

• Consult <strong>for</strong> adaptability to other regulations.<br />

• Thermometer temperature range: 0-120ºC.<br />

• Flow indication range: 2-12 l/min.<br />

• Manometer scale: 0-10 bar.<br />

• Connections: 3/4”H.<br />

• Distance between branches: 95 mm.<br />

+<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />

FLOW RETURN VESSEL JOINT<br />

BRANCH BRANCH ACCESSORIES<br />

Complete Complete ST 15/6eco NO NO 70000<br />

Complete Complete ST 15/6eco NO YES 70100<br />

Note: Consult pump curves.<br />

+<br />

HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />

FLOW RETURN VESSEL JOINT<br />

BRANCH BRANCH ACCESSORIES<br />

No Complete ST 15/6eco NO NO 70020<br />

No Complete ST 15/6eco NO YES 70120<br />

Note: Consult pump curves.<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

103


SOLAR HEATING SYSTEMS<br />

HYDRAULIC UNITS<br />

FOR MAJOR INSTALLATIONS<br />

FOR COLLECTOR FIELDS OF UP TO 50 M 2<br />

SAVINGS!<br />

70% SAVINGS ON LABOUR COSTS FOR COMPONENT INSTALLATION<br />

ALL HYDRAULIC COMPONENTS PRE-ASSEMBLED<br />

104 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


HYDRAULIC UNITS FOR MAJOR INSTALLATIONS<br />

• Maximum operating temperature in flow branch: 160ºC.<br />

• Maximum temperature in return branch: 110ºC.<br />

• Maximum temperature of safety valve: 160ºC.<br />

• Hydraulic unit <strong>for</strong> collector fields of up to 50 m 2 .<br />

• Safety valve calibration: 6 bar.<br />

• Thermometer temperature range: 0-120ºC.<br />

• Flow indication range: 5-40l/min.<br />

• Manometer scale: 0-10 bar.<br />

• Distance between branches: 125mm.<br />

• Connections: 1 1/4" <strong>for</strong> flexible pipe DN25 and bicone nut <strong>for</strong> a pipe Cu 28mm.<br />

• Connection <strong>for</strong> expansion vessel: ¾”M.<br />

• Consult <strong>for</strong> adaptability to other regulations.<br />

03<br />

Solar heating<br />

<strong>systems</strong><br />

PUMP PIPE Cu28 JOINT ACCESSORIES ARTICLE €<br />

TOP S 25-13 (13 metres) NO 75000<br />

TOP S 25-13 (13 metres) YES 75100<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

105


SOLAR HEATING SYSTEMS<br />

HYDRAULIC CHARACTERISTICS<br />

HYDRAULIC UNITS HIGH EFFICIENCY<br />

External control via PWM<br />

H/m<br />

p/kPa<br />

4660/≤5 PWM1 /≥95 PWM2<br />

Wilo-Yonos PARA ST<br />

7<br />

6 4178/15 PWM1 /85 PWM2<br />

15/7.0, 25/7.0, 30/7.0<br />

1~230 V - Rp ½, Rp 1, Rp 1 ¼<br />

n-1/min/%PWM 1/% PWM 2<br />

70<br />

60<br />

5<br />

3695/25 PWM1 /75 PWM2<br />

50<br />

4<br />

3213/35 PWM1 /65 PWM2<br />

40<br />

3 30<br />

2730/45 PWM1 /55 PWM2<br />

max.<br />

2 20<br />

2248/55 PWM1 /45 PWM2<br />

1765/65 PWM1 /35 PWM2<br />

1 10<br />

1283/75 PWM1 /25 PWM2<br />

0 0<br />

0 0,5 1,0 1,5 2,0 2,5 3,0<br />

Q/m 3 /h<br />

0<br />

0.2 0.4 0.6 0.8<br />

0 2 4 6 8 10<br />

Q/l/s<br />

Q/lgpm<br />

p 1<br />

/W<br />

40<br />

max.<br />

20<br />

0<br />

0<br />

0,5<br />

800/85 PWM1 /15 PWM2 Q/m 3 /h<br />

1,0<br />

1,5<br />

2,0<br />

2,5<br />

3,0<br />

Tolerances of each curve according to EN 1151-1:2006<br />

106<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


ST15/6 ECO<br />

6<br />

5<br />

Head (m)<br />

4<br />

3<br />

Solar heating<br />

<strong>systems</strong><br />

2<br />

03<br />

1<br />

0<br />

0,5<br />

1 1,5 2 2,5 3 3<br />

Water flow (m 3 /h)<br />

Top S-25-13<br />

Flow height<br />

(m)<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

min.<br />

máx.<br />

0 0,4 0,8 1,2 1,6 2 2,4 2,8 3,2 (m 3 /h)<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 107


SOLAR HEATING SYSTEMS<br />

OKFRESH - Fresh Water Station<br />

Instant hot water whenever you need it<br />

The Fresh Water Station is a system that guarantees instant hot water whenever it is required,<br />

at just the right temperature. This system guarantees coverage of your domestic hot water<br />

needs, avoiding any hygiene or power loss problems connected with domestic hot water storage.<br />

With its instant hot water principle, <strong>Orkli</strong>'s Fresh Water Station is the ideal system <strong>for</strong> use in<br />

homes, residences or sports complexes, and it is perfect <strong>for</strong> use with renewable energy heating<br />

installations. It is simple to install and can be easily adapted to the users' requirements.<br />

COMPONENTS<br />

DCW inlet<br />

Primary circuit outlet<br />

DHW circulation system<br />

Flow switch in DCW inlet. (To activate the<br />

pump when DHW is demanded)<br />

Plate heat exchanger<br />

Heating circulation HE pump<br />

DHW outlet<br />

temperature sensor<br />

Primary circuit intlet<br />

Mixing 3 ways valve (It<br />

controlles DHW outlet<br />

temperature, using a distance<br />

sensor that acts on the<br />

primary water circuit)<br />

DHW outlet<br />

108 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


• Instantaneous domestic hot water production.<br />

• Stainless steel 90 kW heat exchanger.<br />

• Domestic hot water production capacity 30 l/min. or 20 l/min.<br />

(depending on the number of heat exchanger plates).<br />

• Flow meter activation = 2 l/min.<br />

• DHW temperature controlled by a thermostatic valve acting on the<br />

primary circuit's 3-way mixing valve to regulate the heat exchanger<br />

flow.<br />

• Ensures a low return temperature of the water in the primary circuit<br />

(to aid stratification).<br />

• Connection <strong>for</strong> an optional DHW circulating system available.<br />

• The highest temperature is concentrated in the component in the<br />

lowest location so that the heat is naturally transferred to the top part<br />

of the heat exchanger, cooling down the hot zone and preventing<br />

problems with scale.<br />

Available in July<br />

03<br />

Solar heating<br />

<strong>systems</strong><br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Fresh Water Station S40000003 1<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

109


SOLAR HEATING SYSTEMS<br />

INDIRECT HEAT EXCHANGE<br />

SOLAR KIT<br />

The indirect heat exchange <strong>solar</strong> kit is designed <strong>for</strong> centralised <strong>solar</strong> heating installations with<br />

distributed back-up power. Each home has an individual back-up power source and its own<br />

interior distribution circuit supplying domestic water.<br />

This kit regulates the recirculation inlet to the home from the circuit previously heated by the<br />

<strong>solar</strong> collector. If the kit detects that a tap has been turned on and hot water is required, the<br />

flow to the heat exchanger is opened to preheat the domestic water inlet. When the hot water<br />

tap is turned off, the 3-way valve opens the bypass again and shuts off the flow to the heat<br />

exchanger. The shut-off valves allow the central recirculation system to be completely blocked<br />

off at all the inlets.<br />

Fastening template<br />

Heat exchanger<br />

Heating<br />

output<br />

Heating<br />

input<br />

HWR<br />

input<br />

HWR<br />

output<br />

3 ways valves Hydraulic<br />

valve<br />

110 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


did you know…?<br />

that if you wish you may complete the totally regulated installation with the <strong>solar</strong> domestic water kit?<br />

If there is no DHW demand:<br />

If there is DHW demand:<br />

Heating<br />

output<br />

Heating<br />

input<br />

HWR<br />

output<br />

HWR<br />

input<br />

Heating<br />

output<br />

Heating<br />

input<br />

HWR<br />

output<br />

HWR<br />

input<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

• Dimensions: 350 x 308 x 115 mm.<br />

• Heat exchanger power: 35KW.<br />

• Activation flow: 2L/min.<br />

• Maximum HWR operating flow: 15L/min.<br />

• Maximum heating operating flow: 20L/min.<br />

• Maximum HWR pressure: 15bar.<br />

• Maximum heating temperature: 70ºC.<br />

• Connections: ¾”M.<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Solar Kit S40000002 1<br />

HYDRAULIC CHARACTERISTICS<br />

Hot water circuit<br />

Heating<br />

1000 500<br />

H (m)<br />

800 400<br />

600 300<br />

400 200<br />

200 100<br />

H (m)<br />

0 0<br />

0 200 400 600 800 0 200 400 600 800 1000<br />

Flow (L/h)<br />

Flow (L/h)<br />

Hot water circuit<br />

Circuit bypass<br />

Circuit heat exchanger<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 111


SOLAR HEATING SYSTEMS<br />

SOLAR DHW KIT<br />

A universal kit <strong>for</strong> connecting a <strong>solar</strong> hot water tank to a<br />

conventional domestic hot water source<br />

Unit <strong>for</strong> connection to the auxiliary domestic water heating units installed between the <strong>solar</strong><br />

water tank and this back-up power source, normally an instant water heater or a gas or<br />

electric water heater. It includes a 3-way valve, which determines whether the water from the<br />

<strong>solar</strong> water tank should be conveyed via the back-up power source or can be directly sent on<br />

<strong>for</strong> consumption, and a mixing valve regulating the outlet temperature of the domestic hot<br />

water in the <strong>solar</strong> heating + conventional back-up system.<br />

Solar hot water tank<br />

Domestic<br />

hot water<br />

outlet<br />

From the <strong>solar</strong><br />

collector field<br />

Mains water<br />

connection<br />

Return to the<br />

<strong>solar</strong> collector<br />

field<br />

112 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


Hydraulic diagram:<br />

If water in <strong>solar</strong> hot water tank >48ºC<br />

If water in <strong>solar</strong> hot water tank 48ºC<br />

Domestic hot<br />

water outlet<br />

Mains water<br />

connection<br />

From the <strong>solar</strong><br />

hot water tank<br />


SOLAR HEATING SYSTEMS<br />

ZONE VALVES<br />

• To be used in <strong>solar</strong> system primary circuits.<br />

• Fluid: water with glicol up to 50%.<br />

2 ways - Without run-end<br />

micro: 3 wires<br />

improvements<br />

• More robust transmission<br />

• Fluid temperature -20ºC - 160ºC.<br />

• Normally closed in A.<br />

2 ways - With run-end<br />

micro: 5 wires<br />

improvements<br />

• More robust transmission<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

1/2" 30112200 10<br />

3/4" 30212200 10<br />

1" 30312200 10<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

1/2" 30122200 10<br />

3/4" 30222200 10<br />

1" 30322200 10<br />

3 ways - Without run-end<br />

micro: 3 wires<br />

improvements<br />

• More robust transmission<br />

3 ways - With run-end<br />

micro: 5 wires<br />

improvements<br />

• More robust transmission<br />

DESCRIPTION ARTICLE PIECES/BOX € DESCRIPTION ARTICLE PIECES/BOX €<br />

1/2" 40112200 10<br />

1/2" 40122200 10<br />

3/4" 40212200 10<br />

3/4" 40222200 10<br />

1" 40312200 10<br />

1" 40322200 10<br />

M-M SOLAR ZONE VALVES<br />

2 ways - Without run-end<br />

micro: 3 wires M-M<br />

improvements<br />

• More robust transmission<br />

2 ways - With run-end<br />

micro: 5 wires M-M<br />

improvements<br />

• More robust transmission<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3/4" 30612200 10<br />

1" 30712200 10<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

1" 30722200 10<br />

3 ways - Without run-end<br />

micro: 3 wires M-M<br />

improvements<br />

• More robust transmission<br />

3 ways - With run-end<br />

micro: 5 wires M-M<br />

improvements<br />

• More robust transmission<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3/4" 40612200 10<br />

1" 40712200 10<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

1" 40722200 10<br />

Note: Same discount as zone valves section.<br />

114 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


SAFETY VALVES<br />

• Safety valve <strong>for</strong> <strong>solar</strong> installation primary circuits.<br />

• Suitable <strong>for</strong> working with 50% water-glycol mixture.<br />

• Maximum operating temperature: 160ºC.<br />

• Solar safety valve certification: TÜV SV 07 2012 • SOL • 50<br />

• Consult <strong>for</strong> other setting options.<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

Note: Same discount as valves and safety groups section.<br />

FLOWMETERS<br />

• Flow indication range:5/40 l/m y 2-12 l/m.<br />

• Includes: filling/emptying tap.<br />

• Maximum operating temperature: 110ºC.<br />

• Flow regulation.<br />

• Vertical installation.<br />

• Suitable <strong>for</strong> use with 50% water/glycol mix.<br />

1/2"F - 3/4"F (3 bar) 17175-00 50<br />

1/2"F - 3/4"F (4 bar) 17176-00 50<br />

1/2"F - 3/4"F (6 bar) 17177-00 50<br />

1/2"F - 3/4"F (8 bar) 17178-00 50<br />

1/2"F - 3/4"F (10 bar) 17179-00 50<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3/4" F - 1" F (loose nut) / 2-12 l/m E-23045 1<br />

3/4" F - 1 1/2" F (loose nut) / 2-12 l/m E-23046 1<br />

1 1/4" M - 1 1/2" F (loose nut) / 5-40 l/m E-25292 1<br />

SAFETY GROUPS<br />

• Set a 7 bar.<br />

• Featuring:<br />

- Locking tap.<br />

- Purging or vacuum device.<br />

- Antireturn device.<br />

• To be used in <strong>solar</strong> system primary circuits.<br />

Straight orientation<br />

• AISI 302 stainless steel valve spring.<br />

• Chemical-nickel treated brass valve shaft.<br />

• To be assembled outside.<br />

• Special plastic omponents <strong>for</strong> UV rays.<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3/4" 24170 20<br />

3/4" with adaptor to 1/2" 24470 20<br />

Note: Same discount as valves and safety groups section.<br />

COMPENSATION VALVES<br />

• Designed to work outdoors.<br />

• Stainless steel spring.<br />

• Plastic lever adapted to resist UV rays.<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

1/2" - 7K 10576 120<br />

3/4" - 7K 10577 90<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

115


SOLAR HEATING SYSTEMS<br />

DRAIN VALVES/AIR SEPARATORS<br />

Automatic drain valve<br />

• Maximum operating temperature 150ºC.<br />

• Suitable <strong>for</strong> working with water-glycol mixture.<br />

• Maximum operating pressure 6 bar.<br />

Air separator<br />

• Maximum operating temperature 150ºC.<br />

• Suitable <strong>for</strong> working with water-glycol mixture.<br />

• Maximum operating pressure 6 bar.<br />

• To be installed in horizontal lines.<br />

DESCRIPTION ARTICLE PIECES/BOX € DESCRIPTION ARTICLE PIECES/BOX €<br />

3/8" (to be installed with ball valve) E-22721 1<br />

3/8” with accessories <strong>for</strong> 22 mm Cu pipe E-22723 1<br />

3/8" air vent valve with ball valve E-22722 1<br />

MIXING VALVES<br />

Thermostatic mixing valves <strong>for</strong><br />

domestic water<br />

• Include two filters and two antireturns at the<br />

inlet and outlet.<br />

• Kv 1,5 m 3 /h.<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3/4" M E-19806 1<br />

1/2" M without nuts E-19809 1<br />

1/2" H without nuts, 2 ball valves E-19810 1<br />

CONTROLS FOR SOLAR HEATING INSTALLATIONS<br />

• Controls <strong>for</strong> <strong>solar</strong> heating installation primary circuits.<br />

• Temperature sensors included.<br />

• 3 inputs, 1 relay.<br />

• 6 inputs, 3 relays.<br />

Diagrams with:<br />

- Two collector fields, 2 pumps.<br />

- 1 Pump + zone valve; two accumulators.<br />

- 1 Pump + zone valve; two collector fields.<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3 inputs, 1 relay and temperature limitation E-22724 1<br />

6 inputs, 3 relays and temperature limitation E-22725 1<br />

SOLAR EXPANSION VESSELS<br />

• Maximum operating temperature 130ºC.<br />

• Suitable <strong>for</strong> working with water-glycol mixture.<br />

• Connection 3/4”.<br />

• Connection 1"M.<br />

DESCRIPTION ARTICLE PIECES/BOX € DESCRIPTION ARTICLE PIECES/BOX €<br />

12 liters E-22726 1<br />

35 liters E-24891 1<br />

18 liters E-22727 1<br />

50 liters E-24892 1<br />

24 liters E-22728 1<br />

80 liters E-24893 1<br />

116 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com


ACCESSORIES FOR EXPANSION VESSELS<br />

• Includes: Wall fixing plate, 3-piece connector, flexible hose, rawlplugs, screws.<br />

DESCRIPTION ARTICLE PIECES/BOX €<br />

3/4" F connection E-23051 1<br />

Solar heating<br />

<strong>systems</strong><br />

03<br />

Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />

117