03<br />
Solar heating<br />
<strong>systems</strong><br />
energy<br />
efficiency<br />
Compact, "ALL-IN-ONE" <strong>solar</strong> system<br />
Solar panel <strong>for</strong> swimming pools<br />
Hydraulic components<br />
Drain-Unit: dual hydraulic unit with<br />
drain back system<br />
Drain-Unit: hydraulic unit with<br />
drain-back system<br />
Hydraulic units high efficiency<br />
Hydraulic pumping units with<br />
integrated control<br />
Hydraulic pumping units without regulation<br />
Hydraulic units <strong>for</strong> major installations<br />
OKFRESH - Fresh water station<br />
Indirect heat exchange <strong>solar</strong> kit<br />
Solar dhw kit<br />
Zone valves<br />
Safety valves<br />
Flowmeters<br />
Safety groups<br />
Compensation valves<br />
Drain valves/air separators<br />
Mixing valves<br />
Controls <strong>for</strong> <strong>solar</strong> heating installations<br />
Solar expansion vessels<br />
Accessories <strong>for</strong> expansion vessels<br />
Solar heating<br />
<strong>systems</strong><br />
03
SOLAR HEATING SYSTEMS<br />
COMPACT, "ALL-IN-ONE" SOLAR SYSTEM<br />
This is an ALL-IN-ONE <strong>solar</strong> system that uses <strong>solar</strong><br />
thermal energy to heat domestic water. It integrates<br />
the absorber, the pump-circulated system, and the<br />
150l tank. It uses a PV-driven circulating pump,<br />
which means it is a fully autonomous system that<br />
does not require any external power source.<br />
COMPONENTS<br />
All you need in just a single element<br />
Inlet.<br />
1 6<br />
Pump.<br />
2 7<br />
PV panel.<br />
3 8<br />
Methacrylate cover.<br />
4 9<br />
Insulator.<br />
Valve.<br />
Outlet.<br />
Exchanger.<br />
3<br />
4<br />
10<br />
5<br />
6<br />
9<br />
7<br />
8<br />
2sqm stainless steel<br />
collector featuring a blue<br />
selective surface.<br />
5 10<br />
150 litres tank made<br />
of corrosion-resistant<br />
composite materials.<br />
2<br />
1<br />
HOW DOES IT WORK?<br />
From sunrise till water is hot.<br />
85º<br />
STAGE 1<br />
Solar radiation reaches the<br />
collector, which concentrates<br />
the heat that is then<br />
transferred to the heat<br />
transfer fluid that circulates<br />
through the system.<br />
The selective treatment and<br />
the shape of the surface, it<br />
uses a large proportion of<br />
incident radiation. As it is<br />
filled with the heat transfer<br />
fluid, it can use 100% of<br />
the surface.<br />
STAGE 2<br />
The radiation on the surface<br />
is also received on the PV<br />
panel, which generates<br />
the power that drives the<br />
circulating pump.<br />
The pump gets the hot fluid<br />
into the exchanger.<br />
STAGE 3<br />
The heat is transferred to<br />
the tank because the hot<br />
fluid passes from the pump<br />
to the exchanger.<br />
The tank will get hot<br />
whenever there is sunlight<br />
up to the top limit set at<br />
85ºC.<br />
84<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
WHERE IS IT INSTALLED?<br />
It can be adapted to meet different installation needs<br />
The ALL-IN-ONE <strong>solar</strong> system can be placed anywhere requiring domestic hot water (homes, campsites,<br />
community vegetable gardens, country homes and hotels). The ALL-IN-ONE <strong>solar</strong> system can be placed in<br />
a wide variety of places, from a pitched roof (either built-in or not) to a flat surface, a garden or a wall.<br />
03<br />
Solar heating<br />
<strong>systems</strong><br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 85
SOLAR HEATING SYSTEMS<br />
ADVANTAGES<br />
15% CHEAPER<br />
THAN OTHER SYSTEMS OF THE MARKET<br />
Less components<br />
means<br />
less time to install<br />
less final price<br />
and more m 2 available at home.<br />
COMPONENTS TO INSTALL<br />
A SOLAR SYSTEM<br />
COMPONENTS<br />
SYSTEM<br />
DRAIN BACK<br />
SYSTEM<br />
OKSOL SYSTEM<br />
ORKLI ALL-IN-ONE<br />
MATERIAL<br />
Collector<br />
Hydraulic group<br />
Tank<br />
Solar tube<br />
Secondary tube<br />
ACCESSORIES<br />
ELECTRIC<br />
INSTALLATION<br />
Structure 45º<br />
Expansion tank<br />
Sanitary <strong>solar</strong> fluid<br />
Drain valves<br />
Electrical legalization<br />
Material and labor<br />
INSTALLATION TIME 25,5 h. 15,5 h. 9,5 h.<br />
COMPONENT SYSTEM<br />
OKSOL SYSTEM<br />
86 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
• Pump powered by photovoltaic cell.<br />
• Storage capacity: 150 litres.<br />
• Useful collection surface area: 1,95 m 2 .<br />
• Heat exchanger surface: 0,29 m 2 .<br />
• External dimensions:<br />
- Length: 2029 mm.<br />
- Width: 1020 mm.<br />
- Depth: 250 mm.<br />
- Empty weight including tank: 80 kg.<br />
• Structure on floor or flat terrace, structure, sloping roof top structure and wall structure, under request.<br />
03<br />
Solar heating<br />
<strong>systems</strong><br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Solar collector with integrated tank OKSOL-150 1<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 87
SOLAR HEATING SYSTEMS<br />
STRUCTURES<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Wall structure V-00396 1<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Roof-integrated structure V-00397 1<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Non-per<strong>for</strong>ating anchor kit V-01036 6<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Sloping roof top structure V-00395 1<br />
(Non-per<strong>for</strong>atin anchor kit not included)<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Structure on floor or flat terrace (legs) V-01035 1<br />
88 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
ACCESSORIES<br />
Protective awning<br />
Centrifugal pump<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Centrifugal pump V-01981 1<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Protective awning V-02521 1<br />
Non-return valve<br />
3-bar safety valve<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Non-return valve V-01982 1<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3-bar safety valve V-01983 1<br />
P+5 safety valve Heat-carrying fluid (16 litre tank)<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
P+T safety valve V-01984 1<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Heat-carrying fluid V-01985 1<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
89
SOLAR HEATING SYSTEMS<br />
SOLAR PANEL FOR SWIMMING POOLS<br />
Heated pool water almost all year round. An efficient, af<strong>for</strong>dable alternative.<br />
This is one of the most technically efficient, cost-effective applications <strong>for</strong> swimming pool<br />
water heating. Your pool season is extended by 2-3 months with this <strong>solar</strong> panel system,<br />
as the process involves heating large amounts of water to a relatively low temperature. A<br />
solution using <strong>solar</strong> power: a clean, free, inexhaustible power source to keep your pool water<br />
at just the right temperature.<br />
FEATURES<br />
Stainless steel <strong>solar</strong> collector.<br />
Collection surface area 2 m² and weight 15 Kg.<br />
3 hydraulic connections (Ø ¾) <strong>for</strong> any<br />
installation configuration.<br />
Dimensions 2000 x 1000 x 18.<br />
Sold in batches of 4 units.<br />
Panels guaranteed <strong>for</strong> 5 years.<br />
2000<br />
ISO G 3/4"<br />
1000<br />
90 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
HOW DOES IT WORK?<br />
03<br />
Solar heating<br />
<strong>systems</strong><br />
ADVANTAGES<br />
It extends the pool season by 2-3 months (at temperatures over 25ºC)<br />
The system is compatible with other auxiliary pool heating <strong>systems</strong>.<br />
Excess heat can be used <strong>for</strong> domestic hot water production, via a heat exchanger.<br />
Adaptable to all kinds of pool. The system is connected to the existing filter circuit using a heat exchanger<br />
or directly, depending on the type of filtering.<br />
Totally controllable via a central control unit. It enables the pool temperature to be controlled and the<br />
<strong>solar</strong> collector system to be switched off when the water reaches the desired temperature.<br />
A smaller heating surface area is required compared to other <strong>systems</strong> on the market.<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 91
SOLAR HEATING SYSTEMS<br />
SOLAR PANEL FOR SWIMMING POOLS<br />
• Absorber type: Stainless steel absorber with selective coating.<br />
• Dimensions: Length 2000 mm ± 1 mm, width 1000 mm ± 0.5 mm.<br />
• Surface: 2 m 2 .<br />
• Aperture surface: 1.95 m 2 .<br />
• Weight: 19 kg.<br />
• Interior volume: 32 litres.<br />
• Connection openings ISO G 3/4”.<br />
• Pressure control resistance: 6 bar.<br />
• Maximum working pressure: 3 bar.<br />
• Nominal flow: 90 l/h m 2 .<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Solar panel <strong>for</strong> swimming pools V-01850 1<br />
HYDRAULIC CHARACTERISTICS<br />
Pressure drop<br />
400<br />
350<br />
300<br />
250<br />
mmca<br />
200<br />
150<br />
100<br />
50<br />
0<br />
0 1 2<br />
3 4<br />
l/min<br />
92<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
ALL THE HYDRAULIC COMPONENTS<br />
REQUIRED FOR A SOLAR INSTALLATION<br />
Air vent valve<br />
with ball valve<br />
Solar hydraulic pump units<br />
(or Drain-back system)<br />
Collectors field<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
Solar<br />
expansion<br />
vessels<br />
Support system<br />
Boiler<br />
Swimming pool<br />
Zone<br />
valve<br />
Drain valves<br />
with air<br />
separators<br />
Solar DHW<br />
kit<br />
Hot water tank<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
93
SOLAR HEATING SYSTEMS<br />
DRAIN UNIT:<br />
HYDRAULIC UNIT WITH DRAIN-BACK SYSTEM<br />
A solution to prevent<br />
overheating and<br />
freezing.<br />
ADVANTAGES<br />
BIGGER SAVINGS simply select all the<br />
components you need<br />
COMPATIBLE with all the collectors, heat<br />
exchangers and regulators on the market<br />
For INSTALLATIONS with a larger number<br />
of collectors than other market alternatives<br />
HOW DOES IT WORK?<br />
System off -<br />
Collectors empty<br />
OFF<br />
Maximum<br />
temperatures<br />
OFF<br />
System off -<br />
Collectors empty<br />
(no danger of vaporisation)<br />
OFF<br />
OFF<br />
ON<br />
ON<br />
System start-up -<br />
Filling circuit<br />
temperatures -0ºC<br />
System off -<br />
Collectors empty<br />
(no danger of freezing)<br />
OFF<br />
OFF<br />
ON<br />
System running -<br />
Forced circulation<br />
OFF<br />
94<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
SELECTION GUIDE<br />
The Drain-Unit selection is determined by the height of the installation. Bear in mind the difference in height<br />
between the top of the collector array and the bottom part of the Drain-Unit positioning.<br />
N.b.: less pump power required if the Drain-Unit is installed just above the collector field.<br />
HEIGHT OF INSTALLATION* 3-5 metres 5-10 metres 10-15 metres 3- 10 metres 10-15 metres<br />
RECOMMENDED MODEL 6-metre pumps 6-metre + 6-metre pumps 11 + 6-metre pumps 11-metre pumps 11 + 6-metre pumps<br />
ECONOMY MODEL 6-metre pumps 11-metre pumps Unfit 11-metre pumps 11 + 6-metre pumps<br />
NUMBER OF COLLECTORS** 1-5 1-4 1-4 4-10 4-8<br />
*Height from the top of the <strong>solar</strong> collectors to the lowest point of the drain unit<br />
**Calculated <strong>for</strong> a collector capacity of 1.25 litres and tube 15 mm.<br />
It can be used with installations that have a larger number of collectors than other market alternatives.<br />
The volume of the circuit above the drain unit must not exceed 8 litres of working volume of the air<br />
separator in drain units with a single tank (or 16 litres <strong>for</strong> drain units with 2 tanks).<br />
Volume calculation in upper part: Volume Nº of collectors Volume of fluid<br />
= +<br />
+<br />
in collector<br />
Volume<br />
of pipes<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
DRAIN UNIT WITH INTEGRATED REGULATION<br />
• Maximum operating temperature: 110ºC.<br />
• Maximum peaks: 130ºC.<br />
• Safety valve calibration: 3 bar.<br />
• Flow indication range: 2-12 litres/min.<br />
• Maximum separation volume: 8 litres.<br />
• Connections: bicone nut <strong>for</strong> a Cu15mm o ½”M pipe.<br />
• Control options with pre-connections made.<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
TWO 6-metre PUMPS<br />
PUMPS REGULATION ARTICLE €<br />
6 metres + 6 metres Basic (3 sensors, 1 relay) 74110BA<br />
6 metres + 6 metres Vision (6 sensors, 3 relays) 74110VI<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
95
SOLAR HEATING SYSTEMS<br />
DRAIN UNIT WITH INTEGRATED REGULATION<br />
ONE 11-metre PUMP<br />
PUMPS REGULATION ARTICLE €<br />
11 metres Basic (3 sensors, 1 relay) 74200BA<br />
11 metres Vision (6 sensors, 3 relays) 74200VI<br />
ONE 6-metre PUMP<br />
PUMPS REGULATION ARTICLE €<br />
6 metres Basic (3 sensors, 1 relay) 74100BA<br />
6 metres Vision (6 sensors, 3 relays) 74100VI<br />
96 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
DRAIN UNIT WITH INTEGRATED REGULATION<br />
TWO 11+6-metre PUMPS<br />
03<br />
Solar heating<br />
<strong>systems</strong><br />
PUMPS REGULATION ARTICLE €<br />
11 metres + 6 metres Basic (3 sensors, 1 relay) 74210BA<br />
11 metres + 6 metres Vision (6 sensors, 3 relays) 74210VI<br />
DRAIN UNIT WITHOUT REGULATION<br />
• Maximum operating temperature: 110ºC.<br />
• Maximum peaks: 130ºC.<br />
• Safety valve calibration: 3 bar.<br />
• Flow indication range: 2-12 litres/min.<br />
• Maximum separation volume: 8 litres.<br />
• Connections: bicone nut <strong>for</strong> a Cu15mm o ½”M pipe.<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
• Recommended characteristics:<br />
• Solar regulation with a differential relay.<br />
• Maximum temperature function of collector 110ºC. (recommended).<br />
• Difference in activation temperature 10-15ºC.(recommended).<br />
PUMPS REGULATION ARTICLE €<br />
6 metres + 6 metres - 74110<br />
11 metres - 74200<br />
6 metres - 74100<br />
11 metres + 6 metres - 74210<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
97
SOLAR HEATING SYSTEMS<br />
For installations with twice as many <strong>solar</strong> collectors as the existing<br />
system.<br />
DRAIN UNIT: NEW HYDRAULIC UNIT WITH DRAIN BACK SYSTEM<br />
• Maximum operating temperature: 110ºC.<br />
• Maximum peaks: 130ºC.<br />
• Safety valve calibration: 3 bar.<br />
• Flow indication range: 2-12 litres/min.<br />
• Maximum separation volume: 16 litres.<br />
• Connections: bicone nut <strong>for</strong> a Cu15mm o ½”M pipe.<br />
• Control options with pre-connections made.<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
ONE 11-metre PUMPS<br />
• In case of no regulation options, the regulation must comply with<br />
the following characteristics:<br />
- Solar regulation with a differential relay.<br />
- Maximum temperature function of collector 110ºC.<br />
(recommended).<br />
- Difference in activation temperature 10-15ºC.(recommended).<br />
PUMPS REGULATION ARTICLE €<br />
11 metres Basic (3 sensors, 1 relay) 74200BADO<br />
11 metres Vision (6 sensors, 3 relays) 74200VIDO<br />
11 metres NO 74200DO<br />
98 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
DRAIN UNIT: NEW HYDRAULIC UNIT WITH DRAIN BACK SYSTEM<br />
TWO 11+6-metre PUMPS<br />
03<br />
Solar heating<br />
<strong>systems</strong><br />
PUMPS REGULATION ARTICLE €<br />
11 metres + 6 metres Basic (3 sensors, 1 relay) 74210BADO<br />
11 metres + 6 metres Vision (6 sensors, 3 relays) 74210VIDO<br />
11 metres + 6 metres NO 74210DO<br />
Drainback tank extension kit<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Tank V-00625 1<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 99
SOLAR HEATING SYSTEMS<br />
HYDRAULIC UNITS HIGH EFFICIENCY<br />
The optimum efficiency of the sun as a power source<br />
The Solar<strong>Orkli</strong> line opts <strong>for</strong> technologically innovative<br />
products contributing to smarter, more sustainable<br />
consumption of renewable energies. An example are<br />
the high-efficiency <strong>solar</strong> hydraulic units, which include<br />
components that can increase energy efficiency by<br />
almost 50%.<br />
100 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
HYDRAULIC UNITS HIGH EFFICIENCY<br />
• Maximum working temperature in flow branch: 120ºC.<br />
• Maximum working temperature in return branch: 100ºC.<br />
• Maximum working temperature of safety valve: 160ºC.<br />
• Safety valve calibration: 6 bar.<br />
• Thermometer temperature range: 0-120ºC.<br />
• Flow meter indication range: 2-12 l/min. (visual flow meter);<br />
2-40 l/min. (electronic).<br />
• High energy efficiency pump with cabling preconnection.<br />
• External PWM pump modulation.<br />
• Hydraulic unit <strong>for</strong> <strong>solar</strong> collector fields up to 16 m 2 .<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
• Pump consumption range: 4-60W.<br />
• Energy count option on models with electronic sensors.<br />
• Manometer scale: 0-10 bar.<br />
• Connections: 3/4"H.<br />
• Branch distance: 95 mm.<br />
• Regulation with connections made.<br />
• EPP insulation.<br />
+<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
HYDRAULICS PUMP CLIMATE CONTROL ELECTRONIC FLOW EXPANSION ARTICLE €<br />
BASIC HE TEMPERATURE AND VESSEL JOINT<br />
PRESSURE SENSORS ACCESSORIES<br />
Complete Yonos Para ST 15/7 PWM YES YES YES 73140BAHE<br />
Complete Yonos Para ST 15/7 PWM YES NO YES 73100BAHE<br />
Complete Yonos Para ST 15/7 PWM YES YES NO 73040BAHE<br />
Complete Yonos Para ST 15/7 PWM YES NO NO 73000BAHE<br />
Complete Yonos Para ST 15/7 PWM NO YES YES 73140HE<br />
Complete Yonos Para ST 15/7 PWM NO NO YES 73100HE<br />
Complete Yonos Para ST 15/7 PWM NO YES NO 73040HE<br />
Complete Yonos Para ST 15/7 PWM NO NO NO 73000HE<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 101
SOLAR HEATING SYSTEMS<br />
HYDRAULIC PUMPING UNITS WITH INTEGRATED CONTROL<br />
• Maximum operating temperature in flow branch: 160ºC<br />
• Flow indication range: 2-12 l/min.<br />
• Maximum operating temperature in return branch: 110ºC.<br />
• Manometer scale: 0-10 bar.<br />
• Maximum operating temperature in safety valve: 160ºC.<br />
• Connections: 3/4”H.<br />
• Hydraulic unit <strong>for</strong> collector fields of up to 16 m 2 .<br />
• Distance between branches: 95 mm.<br />
• Safety valve calibration: 6 bar<br />
• Control with connections made.<br />
• Thermometer temperature range: 0-120ºC.<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
+<br />
HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />
FLOW RETURN VESSEL JOINT<br />
BRANCH BRANCH ACCESSORIES<br />
Complete Complete ST 15/6eco Basic (3 inputs, 1 relay) NO 70000BA<br />
Complete Complete ST 15/6eco Vision (6 inputs, 3 relays) NO 70000VI<br />
Complete Complete ST 15/6eco Basic (3 inputs, 1 relay) YES 70100BA<br />
Complete Complete ST 15/6eco Vision (6 inputs, 3 relay) YES 70100VI<br />
Note: Consult pump curves.<br />
+<br />
Note: Consult pump curves.<br />
HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />
FLOW RETURN VESSEL JOINT<br />
BRANCH BRANCH ACCESSORIES<br />
NO Complete ST 15/6eco Basic (3 inputs, 1 relay) NO 70020BA<br />
NO Complete ST 15/6eco Vision (6 inputs, 3 relays) NO 70020VI<br />
NO Complete ST 15/6eco Basic (3 inputs, 1 relay) YES 70120BA<br />
NO Complete ST 15/6eco Vision (6 inputs, 3 relays) YES 70120VI<br />
102<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
HYDRAULIC PUMPING UNITS WITHOUT REGULATION<br />
• Maximum operating temperature in flow branch: 160ºC<br />
• Maximum operating temperature in return branch: 110ºC.<br />
• Maximum operating temperature in safety valve: 160ºC.<br />
• Hydraulic unit <strong>for</strong> collector fields of up to 16 m 2 .<br />
• Safety valve calibration: 6 bar.<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
• Thermometer temperature range: 0-120ºC.<br />
• Flow indication range: 2-12 l/min.<br />
• Manometer scale: 0-10 bar.<br />
• Connections: 3/4”H.<br />
• Distance between branches: 95 mm.<br />
+<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />
FLOW RETURN VESSEL JOINT<br />
BRANCH BRANCH ACCESSORIES<br />
Complete Complete ST 15/6eco NO NO 70000<br />
Complete Complete ST 15/6eco NO YES 70100<br />
Note: Consult pump curves.<br />
+<br />
HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE €<br />
FLOW RETURN VESSEL JOINT<br />
BRANCH BRANCH ACCESSORIES<br />
No Complete ST 15/6eco NO NO 70020<br />
No Complete ST 15/6eco NO YES 70120<br />
Note: Consult pump curves.<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
103
SOLAR HEATING SYSTEMS<br />
HYDRAULIC UNITS<br />
FOR MAJOR INSTALLATIONS<br />
FOR COLLECTOR FIELDS OF UP TO 50 M 2<br />
SAVINGS!<br />
70% SAVINGS ON LABOUR COSTS FOR COMPONENT INSTALLATION<br />
ALL HYDRAULIC COMPONENTS PRE-ASSEMBLED<br />
104 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
HYDRAULIC UNITS FOR MAJOR INSTALLATIONS<br />
• Maximum operating temperature in flow branch: 160ºC.<br />
• Maximum temperature in return branch: 110ºC.<br />
• Maximum temperature of safety valve: 160ºC.<br />
• Hydraulic unit <strong>for</strong> collector fields of up to 50 m 2 .<br />
• Safety valve calibration: 6 bar.<br />
• Thermometer temperature range: 0-120ºC.<br />
• Flow indication range: 5-40l/min.<br />
• Manometer scale: 0-10 bar.<br />
• Distance between branches: 125mm.<br />
• Connections: 1 1/4" <strong>for</strong> flexible pipe DN25 and bicone nut <strong>for</strong> a pipe Cu 28mm.<br />
• Connection <strong>for</strong> expansion vessel: ¾”M.<br />
• Consult <strong>for</strong> adaptability to other regulations.<br />
03<br />
Solar heating<br />
<strong>systems</strong><br />
PUMP PIPE Cu28 JOINT ACCESSORIES ARTICLE €<br />
TOP S 25-13 (13 metres) NO 75000<br />
TOP S 25-13 (13 metres) YES 75100<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
105
SOLAR HEATING SYSTEMS<br />
HYDRAULIC CHARACTERISTICS<br />
HYDRAULIC UNITS HIGH EFFICIENCY<br />
External control via PWM<br />
H/m<br />
p/kPa<br />
4660/≤5 PWM1 /≥95 PWM2<br />
Wilo-Yonos PARA ST<br />
7<br />
6 4178/15 PWM1 /85 PWM2<br />
15/7.0, 25/7.0, 30/7.0<br />
1~230 V - Rp ½, Rp 1, Rp 1 ¼<br />
n-1/min/%PWM 1/% PWM 2<br />
70<br />
60<br />
5<br />
3695/25 PWM1 /75 PWM2<br />
50<br />
4<br />
3213/35 PWM1 /65 PWM2<br />
40<br />
3 30<br />
2730/45 PWM1 /55 PWM2<br />
max.<br />
2 20<br />
2248/55 PWM1 /45 PWM2<br />
1765/65 PWM1 /35 PWM2<br />
1 10<br />
1283/75 PWM1 /25 PWM2<br />
0 0<br />
0 0,5 1,0 1,5 2,0 2,5 3,0<br />
Q/m 3 /h<br />
0<br />
0.2 0.4 0.6 0.8<br />
0 2 4 6 8 10<br />
Q/l/s<br />
Q/lgpm<br />
p 1<br />
/W<br />
40<br />
max.<br />
20<br />
0<br />
0<br />
0,5<br />
800/85 PWM1 /15 PWM2 Q/m 3 /h<br />
1,0<br />
1,5<br />
2,0<br />
2,5<br />
3,0<br />
Tolerances of each curve according to EN 1151-1:2006<br />
106<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
ST15/6 ECO<br />
6<br />
5<br />
Head (m)<br />
4<br />
3<br />
Solar heating<br />
<strong>systems</strong><br />
2<br />
03<br />
1<br />
0<br />
0,5<br />
1 1,5 2 2,5 3 3<br />
Water flow (m 3 /h)<br />
Top S-25-13<br />
Flow height<br />
(m)<br />
13<br />
12<br />
11<br />
10<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
min.<br />
máx.<br />
0 0,4 0,8 1,2 1,6 2 2,4 2,8 3,2 (m 3 /h)<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 107
SOLAR HEATING SYSTEMS<br />
OKFRESH - Fresh Water Station<br />
Instant hot water whenever you need it<br />
The Fresh Water Station is a system that guarantees instant hot water whenever it is required,<br />
at just the right temperature. This system guarantees coverage of your domestic hot water<br />
needs, avoiding any hygiene or power loss problems connected with domestic hot water storage.<br />
With its instant hot water principle, <strong>Orkli</strong>'s Fresh Water Station is the ideal system <strong>for</strong> use in<br />
homes, residences or sports complexes, and it is perfect <strong>for</strong> use with renewable energy heating<br />
installations. It is simple to install and can be easily adapted to the users' requirements.<br />
COMPONENTS<br />
DCW inlet<br />
Primary circuit outlet<br />
DHW circulation system<br />
Flow switch in DCW inlet. (To activate the<br />
pump when DHW is demanded)<br />
Plate heat exchanger<br />
Heating circulation HE pump<br />
DHW outlet<br />
temperature sensor<br />
Primary circuit intlet<br />
Mixing 3 ways valve (It<br />
controlles DHW outlet<br />
temperature, using a distance<br />
sensor that acts on the<br />
primary water circuit)<br />
DHW outlet<br />
108 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
• Instantaneous domestic hot water production.<br />
• Stainless steel 90 kW heat exchanger.<br />
• Domestic hot water production capacity 30 l/min. or 20 l/min.<br />
(depending on the number of heat exchanger plates).<br />
• Flow meter activation = 2 l/min.<br />
• DHW temperature controlled by a thermostatic valve acting on the<br />
primary circuit's 3-way mixing valve to regulate the heat exchanger<br />
flow.<br />
• Ensures a low return temperature of the water in the primary circuit<br />
(to aid stratification).<br />
• Connection <strong>for</strong> an optional DHW circulating system available.<br />
• The highest temperature is concentrated in the component in the<br />
lowest location so that the heat is naturally transferred to the top part<br />
of the heat exchanger, cooling down the hot zone and preventing<br />
problems with scale.<br />
Available in July<br />
03<br />
Solar heating<br />
<strong>systems</strong><br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Fresh Water Station S40000003 1<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
109
SOLAR HEATING SYSTEMS<br />
INDIRECT HEAT EXCHANGE<br />
SOLAR KIT<br />
The indirect heat exchange <strong>solar</strong> kit is designed <strong>for</strong> centralised <strong>solar</strong> heating installations with<br />
distributed back-up power. Each home has an individual back-up power source and its own<br />
interior distribution circuit supplying domestic water.<br />
This kit regulates the recirculation inlet to the home from the circuit previously heated by the<br />
<strong>solar</strong> collector. If the kit detects that a tap has been turned on and hot water is required, the<br />
flow to the heat exchanger is opened to preheat the domestic water inlet. When the hot water<br />
tap is turned off, the 3-way valve opens the bypass again and shuts off the flow to the heat<br />
exchanger. The shut-off valves allow the central recirculation system to be completely blocked<br />
off at all the inlets.<br />
Fastening template<br />
Heat exchanger<br />
Heating<br />
output<br />
Heating<br />
input<br />
HWR<br />
input<br />
HWR<br />
output<br />
3 ways valves Hydraulic<br />
valve<br />
110 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
did you know…?<br />
that if you wish you may complete the totally regulated installation with the <strong>solar</strong> domestic water kit?<br />
If there is no DHW demand:<br />
If there is DHW demand:<br />
Heating<br />
output<br />
Heating<br />
input<br />
HWR<br />
output<br />
HWR<br />
input<br />
Heating<br />
output<br />
Heating<br />
input<br />
HWR<br />
output<br />
HWR<br />
input<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
• Dimensions: 350 x 308 x 115 mm.<br />
• Heat exchanger power: 35KW.<br />
• Activation flow: 2L/min.<br />
• Maximum HWR operating flow: 15L/min.<br />
• Maximum heating operating flow: 20L/min.<br />
• Maximum HWR pressure: 15bar.<br />
• Maximum heating temperature: 70ºC.<br />
• Connections: ¾”M.<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Solar Kit S40000002 1<br />
HYDRAULIC CHARACTERISTICS<br />
Hot water circuit<br />
Heating<br />
1000 500<br />
H (m)<br />
800 400<br />
600 300<br />
400 200<br />
200 100<br />
H (m)<br />
0 0<br />
0 200 400 600 800 0 200 400 600 800 1000<br />
Flow (L/h)<br />
Flow (L/h)<br />
Hot water circuit<br />
Circuit bypass<br />
Circuit heat exchanger<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com 111
SOLAR HEATING SYSTEMS<br />
SOLAR DHW KIT<br />
A universal kit <strong>for</strong> connecting a <strong>solar</strong> hot water tank to a<br />
conventional domestic hot water source<br />
Unit <strong>for</strong> connection to the auxiliary domestic water heating units installed between the <strong>solar</strong><br />
water tank and this back-up power source, normally an instant water heater or a gas or<br />
electric water heater. It includes a 3-way valve, which determines whether the water from the<br />
<strong>solar</strong> water tank should be conveyed via the back-up power source or can be directly sent on<br />
<strong>for</strong> consumption, and a mixing valve regulating the outlet temperature of the domestic hot<br />
water in the <strong>solar</strong> heating + conventional back-up system.<br />
Solar hot water tank<br />
Domestic<br />
hot water<br />
outlet<br />
From the <strong>solar</strong><br />
collector field<br />
Mains water<br />
connection<br />
Return to the<br />
<strong>solar</strong> collector<br />
field<br />
112 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
Hydraulic diagram:<br />
If water in <strong>solar</strong> hot water tank >48ºC<br />
If water in <strong>solar</strong> hot water tank 48ºC<br />
Domestic hot<br />
water outlet<br />
Mains water<br />
connection<br />
From the <strong>solar</strong><br />
hot water tank<br />
SOLAR HEATING SYSTEMS<br />
ZONE VALVES<br />
• To be used in <strong>solar</strong> system primary circuits.<br />
• Fluid: water with glicol up to 50%.<br />
2 ways - Without run-end<br />
micro: 3 wires<br />
improvements<br />
• More robust transmission<br />
• Fluid temperature -20ºC - 160ºC.<br />
• Normally closed in A.<br />
2 ways - With run-end<br />
micro: 5 wires<br />
improvements<br />
• More robust transmission<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
1/2" 30112200 10<br />
3/4" 30212200 10<br />
1" 30312200 10<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
1/2" 30122200 10<br />
3/4" 30222200 10<br />
1" 30322200 10<br />
3 ways - Without run-end<br />
micro: 3 wires<br />
improvements<br />
• More robust transmission<br />
3 ways - With run-end<br />
micro: 5 wires<br />
improvements<br />
• More robust transmission<br />
DESCRIPTION ARTICLE PIECES/BOX € DESCRIPTION ARTICLE PIECES/BOX €<br />
1/2" 40112200 10<br />
1/2" 40122200 10<br />
3/4" 40212200 10<br />
3/4" 40222200 10<br />
1" 40312200 10<br />
1" 40322200 10<br />
M-M SOLAR ZONE VALVES<br />
2 ways - Without run-end<br />
micro: 3 wires M-M<br />
improvements<br />
• More robust transmission<br />
2 ways - With run-end<br />
micro: 5 wires M-M<br />
improvements<br />
• More robust transmission<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3/4" 30612200 10<br />
1" 30712200 10<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
1" 30722200 10<br />
3 ways - Without run-end<br />
micro: 3 wires M-M<br />
improvements<br />
• More robust transmission<br />
3 ways - With run-end<br />
micro: 5 wires M-M<br />
improvements<br />
• More robust transmission<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3/4" 40612200 10<br />
1" 40712200 10<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
1" 40722200 10<br />
Note: Same discount as zone valves section.<br />
114 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
SAFETY VALVES<br />
• Safety valve <strong>for</strong> <strong>solar</strong> installation primary circuits.<br />
• Suitable <strong>for</strong> working with 50% water-glycol mixture.<br />
• Maximum operating temperature: 160ºC.<br />
• Solar safety valve certification: TÜV SV 07 2012 • SOL • 50<br />
• Consult <strong>for</strong> other setting options.<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
Note: Same discount as valves and safety groups section.<br />
FLOWMETERS<br />
• Flow indication range:5/40 l/m y 2-12 l/m.<br />
• Includes: filling/emptying tap.<br />
• Maximum operating temperature: 110ºC.<br />
• Flow regulation.<br />
• Vertical installation.<br />
• Suitable <strong>for</strong> use with 50% water/glycol mix.<br />
1/2"F - 3/4"F (3 bar) 17175-00 50<br />
1/2"F - 3/4"F (4 bar) 17176-00 50<br />
1/2"F - 3/4"F (6 bar) 17177-00 50<br />
1/2"F - 3/4"F (8 bar) 17178-00 50<br />
1/2"F - 3/4"F (10 bar) 17179-00 50<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3/4" F - 1" F (loose nut) / 2-12 l/m E-23045 1<br />
3/4" F - 1 1/2" F (loose nut) / 2-12 l/m E-23046 1<br />
1 1/4" M - 1 1/2" F (loose nut) / 5-40 l/m E-25292 1<br />
SAFETY GROUPS<br />
• Set a 7 bar.<br />
• Featuring:<br />
- Locking tap.<br />
- Purging or vacuum device.<br />
- Antireturn device.<br />
• To be used in <strong>solar</strong> system primary circuits.<br />
Straight orientation<br />
• AISI 302 stainless steel valve spring.<br />
• Chemical-nickel treated brass valve shaft.<br />
• To be assembled outside.<br />
• Special plastic omponents <strong>for</strong> UV rays.<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3/4" 24170 20<br />
3/4" with adaptor to 1/2" 24470 20<br />
Note: Same discount as valves and safety groups section.<br />
COMPENSATION VALVES<br />
• Designed to work outdoors.<br />
• Stainless steel spring.<br />
• Plastic lever adapted to resist UV rays.<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
1/2" - 7K 10576 120<br />
3/4" - 7K 10577 90<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
115
SOLAR HEATING SYSTEMS<br />
DRAIN VALVES/AIR SEPARATORS<br />
Automatic drain valve<br />
• Maximum operating temperature 150ºC.<br />
• Suitable <strong>for</strong> working with water-glycol mixture.<br />
• Maximum operating pressure 6 bar.<br />
Air separator<br />
• Maximum operating temperature 150ºC.<br />
• Suitable <strong>for</strong> working with water-glycol mixture.<br />
• Maximum operating pressure 6 bar.<br />
• To be installed in horizontal lines.<br />
DESCRIPTION ARTICLE PIECES/BOX € DESCRIPTION ARTICLE PIECES/BOX €<br />
3/8" (to be installed with ball valve) E-22721 1<br />
3/8” with accessories <strong>for</strong> 22 mm Cu pipe E-22723 1<br />
3/8" air vent valve with ball valve E-22722 1<br />
MIXING VALVES<br />
Thermostatic mixing valves <strong>for</strong><br />
domestic water<br />
• Include two filters and two antireturns at the<br />
inlet and outlet.<br />
• Kv 1,5 m 3 /h.<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3/4" M E-19806 1<br />
1/2" M without nuts E-19809 1<br />
1/2" H without nuts, 2 ball valves E-19810 1<br />
CONTROLS FOR SOLAR HEATING INSTALLATIONS<br />
• Controls <strong>for</strong> <strong>solar</strong> heating installation primary circuits.<br />
• Temperature sensors included.<br />
• 3 inputs, 1 relay.<br />
• 6 inputs, 3 relays.<br />
Diagrams with:<br />
- Two collector fields, 2 pumps.<br />
- 1 Pump + zone valve; two accumulators.<br />
- 1 Pump + zone valve; two collector fields.<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3 inputs, 1 relay and temperature limitation E-22724 1<br />
6 inputs, 3 relays and temperature limitation E-22725 1<br />
SOLAR EXPANSION VESSELS<br />
• Maximum operating temperature 130ºC.<br />
• Suitable <strong>for</strong> working with water-glycol mixture.<br />
• Connection 3/4”.<br />
• Connection 1"M.<br />
DESCRIPTION ARTICLE PIECES/BOX € DESCRIPTION ARTICLE PIECES/BOX €<br />
12 liters E-22726 1<br />
35 liters E-24891 1<br />
18 liters E-22727 1<br />
50 liters E-24892 1<br />
24 liters E-22728 1<br />
80 liters E-24893 1<br />
116 Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com
ACCESSORIES FOR EXPANSION VESSELS<br />
• Includes: Wall fixing plate, 3-piece connector, flexible hose, rawlplugs, screws.<br />
DESCRIPTION ARTICLE PIECES/BOX €<br />
3/4" F connection E-23051 1<br />
Solar heating<br />
<strong>systems</strong><br />
03<br />
Tel.: +34 943 80 94 80 Fax: +34 943 80 52 41 www.orkli.com<br />
117