08.02.2014 Views

Pfannenberg Catalogue

Pfannenberg Catalogue

Pfannenberg Catalogue

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Audible signaling devices<br />

Connection diagrams<br />

SON 2 DS 5 / DS 10 AC version DS 5 / DS 10 DC version<br />

External tone control<br />

tone 2: terminal 2 connected to ‘-‘<br />

tone 3: terminal 1 connected to ‘-‘<br />

Operating voltage<br />

connection<br />

Optional:<br />

volume control for<br />

DS 5<br />

Operating voltage<br />

connection<br />

(double pole)<br />

Tone selection<br />

(see table on<br />

page 131 for tone<br />

selection switch<br />

settings)<br />

115 V<br />

230 V<br />

AC<br />

L<br />

N<br />

PE<br />

X1<br />

Code switch for setting the tone<br />

Optional: programming mode<br />

for external tone selection<br />

L<br />

N<br />

PE<br />

Optional:<br />

external tone selection<br />

stage 2, 3 and 4<br />

12-48V DC<br />

24V AC<br />

X1<br />

for the supply of additional<br />

sounders; max. 10 of type<br />

DS 10 or max. 15 of type<br />

DS 5<br />

PA 130<br />

Connecting terminals (removable)<br />

Audio input<br />

0 dB 600 Ω<br />

Temperature sensor<br />

Code switch II<br />

1: audio:<br />

switch 1 to ON: activation of the terminal resistor<br />

(120 Ω) for cable monitoring<br />

- audio input 0 dB 600 Ω<br />

2: not used (normally set to OFF)<br />

3: cable monitoring<br />

switch 3 to ON: activation of the resistor (4K7) for<br />

cable monitoring (DC devices only)<br />

4: auxiliary relay<br />

switch 4 to ON: malfunction message output<br />

switch 4 to OFF: activation of additional devices<br />

Malfunction message-/<br />

aux. relay NO/NC<br />

Operating voltage<br />

24 V (48 V DC)<br />

External tone selection<br />

L3-L5<br />

L3<br />

L4<br />

L5<br />

L6<br />

Tone<br />

selection<br />

Code switch I<br />

Self-test:<br />

switch 7 to OFF:<br />

activation of the<br />

self-test every 24 hrs<br />

(operating voltage,<br />

amplifier, driver, tone<br />

test - duration 2 s)<br />

LED‘s - OFF during troule-free operation<br />

operating voltage failure<br />

overheating<br />

driver not operating<br />

not used<br />

Normally<br />

set to ON<br />

Connecting<br />

terminals<br />

AC version<br />

Examples for external tone selection<br />

Setting of code<br />

switch I according<br />

to line 59<br />

Customer application<br />

Relay energised during trouble-free operation<br />

NO<br />

Factory setting<br />

Connecting<br />

terminals<br />

NC<br />

tone SW1 SW2 SW3 SW4<br />

-<br />

51 x<br />

52 x<br />

53 x<br />

54 x<br />

audio x x<br />

55 x x<br />

– x x<br />

56 x x<br />

x = closed<br />

150<br />

www.pfannenberg.com