2013 Michael Phelps Swim Spa RX Owner's Manual - Master Spas
2013 Michael Phelps Swim Spa RX Owner's Manual - Master Spas
2013 Michael Phelps Swim Spa RX Owner's Manual - Master Spas
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SPA TROUBLE-SHOOTING GUIDE<br />
WARNING - Service and repair shall only be performed by a qualified technician. Customer shall<br />
not attempt to repair serviceable or non serviceable parts.<br />
Exceptions:<br />
• Clean/replace filter cartridge<br />
• Replenish chemical feed system as directed by service professional<br />
Propulsion System<br />
Breaker trips when turning the propulsion system on/off<br />
1. Verify that the G.F.C.I. installed on the input power line to the propulsion system is protected<br />
by the factory supplied G.F.C.I.<br />
2. Verify that only 1 G.F.C.I. is installed on the input power line to the propulsion system.<br />
3. Verify sufficient voltage at G.F.C.I. and propulsion system (240V +- 10%)<br />
4. Replace motor<br />
5. Replace VFD<br />
6. Replace G.F.C.I. / Breaker assembly<br />
Press “SPEED UP/ON” and nothing happens<br />
1. Verify voltage to VFD (240V +- 10%)<br />
2. Verify no error codes on VFD display<br />
3. Verify good connection on all VFD wires<br />
4. Verify that control panel is plugged in firmly<br />
5. Replace topside control panel<br />
6. Replace VFD<br />
Press “SPEED UP/ON” and display indicators come on, but no water flow from propulsion unit<br />
1. Verify proper wiring between VFD and motor<br />
2. Check voltage from VFD to motor<br />
a. If no voltage from VFD to motor, replace VFD<br />
b. If sufficient voltage to motor, replace motor<br />
Display indicates system is on, sounds like motor is running,<br />
but no water flow from propulsion system<br />
1. Verify that belt/pulley system is intact and moving<br />
2. Remove prop and inspect for failure<br />
WARNING - NEVER remove propulsion grates without first powering down at the breaker.<br />
Loud squealing noise coming from propulsion system<br />
1. Verify belt tension<br />
2. Replace bearing assembly<br />
Propulsion system will not shut all the way down<br />
1. Hold down the “SPEED DOWN/OFF” button for 7 seconds<br />
Jet pumps will not turn on<br />
1. Verify that E-stop is not tripped<br />
2. Turn timer<br />
3. Check voltage to jet pump contactors<br />
4. Verify that contactor coil(s) are getting the appropriate voltage when E-stop and timer are active<br />
39