SPA TROUBLE-SHOOTING GUIDE<br />

WARNING - Service and repair shall only be performed by a qualified technician. Customer shall<br />

not attempt to repair serviceable or non serviceable parts.<br />

Exceptions:<br />

• Clean/replace filter cartridge<br />

• Replenish chemical feed system as directed by service professional<br />

Propulsion System<br />

Breaker trips when turning the propulsion system on/off<br />

1. Verify that the G.F.C.I. installed on the input power line to the propulsion system is protected<br />

by the factory supplied G.F.C.I.<br />

2. Verify that only 1 G.F.C.I. is installed on the input power line to the propulsion system.<br />

3. Verify sufficient voltage at G.F.C.I. and propulsion system (240V +- 10%)<br />

4. Replace motor<br />

5. Replace VFD<br />

6. Replace G.F.C.I. / Breaker assembly<br />

Press “SPEED UP/ON” and nothing happens<br />

1. Verify voltage to VFD (240V +- 10%)<br />

2. Verify no error codes on VFD display<br />

3. Verify good connection on all VFD wires<br />

4. Verify that control panel is plugged in firmly<br />

5. Replace topside control panel<br />

6. Replace VFD<br />

Press “SPEED UP/ON” and display indicators come on, but no water flow from propulsion unit<br />

1. Verify proper wiring between VFD and motor<br />

2. Check voltage from VFD to motor<br />

a. If no voltage from VFD to motor, replace VFD<br />

b. If sufficient voltage to motor, replace motor<br />

Display indicates system is on, sounds like motor is running,<br />

but no water flow from propulsion system<br />

1. Verify that belt/pulley system is intact and moving<br />

2. Remove prop and inspect for failure<br />

WARNING - NEVER remove propulsion grates without first powering down at the breaker.<br />

Loud squealing noise coming from propulsion system<br />

1. Verify belt tension<br />

2. Replace bearing assembly<br />

Propulsion system will not shut all the way down<br />

1. Hold down the “SPEED DOWN/OFF” button for 7 seconds<br />

Jet pumps will not turn on<br />

1. Verify that E-stop is not tripped<br />

2. Turn timer<br />

3. Check voltage to jet pump contactors<br />

4. Verify that contactor coil(s) are getting the appropriate voltage when E-stop and timer are active<br />