DIMENSIONS IN MILLIMETRES<br />

( DIMENSIONS IN FEET-INCHES )<br />

THIRD ANGLE<br />

PROJECTION<br />

"ALL DIMENSIONS AND DESIGN CRITERIA<br />

R<br />

SUBJECT TO CHANGE WITHOUT NOTICE." PAGE 2 OF 4 R<br />

FILE NO. 186-191 REV. 2<br />

0<br />

0<br />

A<br />

B<br />

FINISH FLOOR<br />

THICKNESS<br />

TOP OF FLOOR COVERING<br />

SHIM THICKNESS<br />

13 ( 1/2 ") TO 25 ( 1" )<br />

TOP OF ROUGH FLOOR<br />

SEE DETAIL #1<br />

WALL FINISH APPLIED AFTER<br />

<strong>VAULT</strong> DOOR IS INSTALLED,<br />

GROUTED AND TRIMMED<br />

1 1 1 mm (4 3/8 ") WALL FINISH<br />

SHOWN<br />

GENERAL CONTRACTOR NOTE<br />

IT IS "MANDATORY" THAT THE OWNERS GENERAL CONTRACTOR GROUT<br />

IN THE SPACE BETWEEN VESTIBULE AND CONCRETE WALL PANEL<br />

AFTER <strong>VAULT</strong> DOOR IS INSTALLED AND APPROVED BY DIEBOLD. GROUT<br />

TO CONSIST OF CLEAN SAND AND CEMENT USING FORMULATION TO<br />

PROVIDE AT LEAST 3,000 P. S. I. ( EQUIVALENT TO 6 BAG MIX ).<br />

CAUTION: GROUTING USING MECHANICAL OR HYDRAULIC METHODS<br />

MAY RESULT IN DAMAGE TO THE <strong>VAULT</strong> DOOR.<br />

NOTE:<br />

0<br />

13 ( 1/2 ") BEDPLATE<br />

0 0<br />

2244 (7’-4 3/8 ")<br />

0<br />

SEE DETAIL #2 AND #3<br />

WALL FINISH APPLIED AFTER <strong>VAULT</strong> DOOR IS INSTALLED 1 1 1mm (4 3/8 ") WALL FINISH SHOWN<br />

LC<br />

EMERGENCY <strong>VAULT</strong><br />

VENTILATOR<br />

WALL OPENING 0<br />

13 ( 1/2 ")<br />

0 (0")<br />

0<br />

2205 (7’-2 13/16 " ) JAMB TRIM<br />

0<br />

124 (4 7/8 ")<br />

24 ( 15/16 " )<br />

0<br />

0<br />

DOOR<br />

2057 (6’-9")<br />

0<br />

0<br />

1460 (4’-9 1/2 ") JAMB TRIM<br />

16 ( 5/8 ") 19 ( 3/4 ") 22 ( 7/8 ") 25 ( 1")<br />

3 ( 1/8 ") 6 ( 1/4 ") 10 ( 3/8 ") 13 ( 1/2 ")<br />

0<br />

171<br />

(6 3/4 ")<br />

0<br />

1988 (6’-6 1/4 ") VESTIBULE CLEAR OPENING<br />

0<br />

SECTION<br />

19 ( 3/4 ")<br />

0<br />

2197 (7’-2 1/2 ") VESTIBULE STAINLESS TRIM<br />

0<br />

E.C. TO PROVIDE AND<br />

INSTALL JUNCTION BOXES<br />

FOR POWER AND ALARM<br />

AT CONDUIT PENETRATIONS<br />

IN DOOR HEADER PANEL<br />

DAYGATE<br />

DAYGATE IN<br />

"OPEN POSITION"<br />

G.C. TO PROVIDE AND INSTALL 13mm X 559mm X 1600mm<br />

( 1/2 " X 1’-10" X 5’-3") BED PLATE WITH #5 ROD FOR<br />

ANCHORING (TYPICAL FOUR CORNERS)<br />

GROUT (SEE GENERAL<br />

CONTRACTOR NOTE)<br />

0<br />

CONCRETE<br />

VESTIBULE<br />

SETTING DETAIL FOR 1 1 1 mm (4 3/8 ") WALL FINISH SHOWN<br />

OWNER’S G.C. TO VERIFY FLOOR COVERING THICKNESS TO BE<br />

APPLIED INSIDE AND OUTSIDE <strong>VAULT</strong>. OWNER’S G.C. TO PREPARE<br />

FLOOR AS REQUIED SO FINISHED FLOOR HEIGHT MEETS OR IS<br />

FEATHERED TO EDGE OF <strong>VAULT</strong> DOOR SILL HEIGHT, BUT DOES NOT<br />

EXCEED TOP OF SILL PLATE<br />

300 ( 1 1 13/16 ")<br />

FINISH FLOOR MATERIAL INSIDE AND OUTSIDE<br />

<strong>VAULT</strong> SHOULD MEET OR BE FEATHERED TO<br />

THIS EDGE OF <strong>VAULT</strong> DOOR SILL PLATE<br />

FINISH<br />

FLOOR<br />

A<br />

0<br />

TOP OF<br />

ROUGH FLOOR<br />

0<br />

0 0<br />

13 ( 1/2 ") BED<br />

PLATE<br />

0<br />

13 ( 1/2 ")<br />

0 0<br />

DETAIL #3<br />

0<br />

1 14<br />

(4 1/2 ")<br />

0<br />

1448 (4’-9") VESTIBULE STAINLESS TRIM<br />

0 0<br />

EMERGENCY <strong>VAULT</strong><br />

VENTILATOR<br />

INTERIOR <strong>ELEVATION</strong><br />

0<br />

2244 (7’-4 3/8 ")<br />

WALL OPENING<br />

DETAIL #2<br />

0<br />

2205 (7’-2 13/16 ")<br />

JAMB TRIM<br />

DOOR SILL<br />

PLATE<br />

13 ( 1/2 ")<br />

0<br />

0<br />

DETAIL #1<br />

LIFT FOR AIR<br />

1600 (5’-3") BED PLATE0<br />

0 0<br />

0<br />

19 ( 3/4 ")<br />

STEEL SILL<br />

SHIM<br />

B THICKNESS<br />

0<br />

2197 (7’-2 1/2 ") VESTIBULE STAINLESS TRIM<br />

0