L571 191<br />
DIMENSIONS IN MILLIMETRES<br />
( DIMENSIONS IN FEET-INCHES )<br />
THIRD ANGLE<br />
PROJECTION<br />
"ALL DIMENSIONS AND DESIGN CRITERIA<br />
SUBJECT TO CHANGE WITHOUT NOTICE." PAGE 1 OF 4<br />
FILE NO. 186-191 REV. 2<br />
CALL 1-800-999-3600<br />
0<br />
0<br />
9mm X 76mm ( 3/8 " X 3")<br />
SHOE PROVIDED AND<br />
INSTALLED BY DIEBOLD<br />
0<br />
0<br />
0<br />
0<br />
64 (2 1/2 ")<br />
WALL PANEL<br />
0<br />
216<br />
(8 1/2 ")<br />
0<br />
0<br />
279<br />
( 1 1")<br />
0<br />
0 0<br />
G.C. TO PROVIDE AND INSTALL<br />
13mm X 559mm X 1600mm<br />
( 1/2 " X 1’-10" X 5’-3") BED<br />
PLATE WITH #5 ROD FOR<br />
ANCHORING (TYPICAL FOUR<br />
CORNERS)<br />
INTERIOR WALL FINISH<br />
AS REQUIRED<br />
OPTIONAL<br />
HORIZONTAL<br />
HANDLE KIT<br />
41-018968-000A<br />
559 (1’-10")<br />
BED PLATE<br />
OPTIONAL ROUND<br />
WHEEL HANDLE KIT<br />
41-018969-000A<br />
(FIELD INSTALLED)<br />
0<br />
0<br />
0<br />
0<br />
R<br />
0<br />
0<br />
38 (1 1/2 ")<br />
210<br />
(8 1/4 ")<br />
CL<br />
0<br />
0<br />
SWING OF DAYGATE<br />
(LEFT HAND SHOWN)<br />
914 (3’-0")<br />
WALL OPENING<br />
1028 (3’-4 1/2 ")<br />
CL C.O. & W.O.<br />
0<br />
000 000000<br />
613 ( 2’-0 1/8 ")<br />
0 0 0 0<br />
198 1063 (3’-5 7/8 ") DOOR<br />
198<br />
(7 13/16 " )<br />
1524 (5’-0")<br />
1448 (4’-9") VESTIBULE STAINLESS TRIM<br />
EMERGENCY <strong>VAULT</strong><br />
VENTILATOR<br />
0 0<br />
0<br />
730 (2’-4 3/4 ")<br />
730 (2’-4 3/4 ")<br />
0 0<br />
1460 (4’-9 1/2 ") JAMB TRIM<br />
0C.O.<br />
0 0<br />
1758 (5’-9 1/4 ")<br />
0<br />
<strong>PLAN</strong> <strong>VIEW</strong><br />
<strong>FRONT</strong> <strong>ELEVATION</strong><br />
38 (1 1/2 ")<br />
0<br />
210<br />
(8 1/4 ")<br />
0<br />
0<br />
0<br />
(7 13/16 " )<br />
1600 (5’-3") BED PLATE0<br />
0<br />
0<br />
0<br />
1295 (4’-3")<br />
0 0<br />
1460 (4’-9 1/2 ") JAMB TRIM<br />
EMERGENCY <strong>VAULT</strong><br />
VENTILATOR<br />
TM<br />
<strong>AMERICAN</strong> <strong>VAULT</strong> DOOR<br />
#154-82 CLASS 1 WITH RAISED SILL<br />
DETAILS FOR (5) SIDED CLASS I SUPER STRENGTH MVS<br />
0<br />
2205 (7’-2 13/16 " ) JAMB TRIM<br />
01600 (5’-3") BED PLATE<br />
0<br />
0 0<br />
83<br />
(3 1/4 ")<br />
RIGHT SWING<br />
DOOR SHOWN<br />
749 (2’-5 1/2 ")<br />
1 146<br />
(3’-9 1/8 " R.)<br />
0<br />
0<br />
0<br />
0<br />
0<br />
32<br />
(1 1/4 ")<br />
1 1 1<br />
( 4 3/8 ")<br />
MAX.<br />
13<br />
( 1/2 ")<br />
0<br />
0 0000000<br />
0<br />
0<br />
125 MINIMUM DOOR SWING FOR<br />
FULL 914mm (3’-0") CLEAR OPENING<br />
WEIGHT OF <strong>VAULT</strong> DOOR AND<br />
VESTIBULE 2040 (4,500 LBS)<br />
00-015482-R/L00C<br />
DOOR STOP<br />
(BY DIEBOLD)<br />
TOP OF ROUGH FLOOR<br />
0<br />
0<br />
TOP OF FLOOR COVERING<br />
0<br />
1 133 (3’-8 5/8 " )<br />
92 (3 5/8 ")<br />
0298<br />
(1 1 3/4 " )<br />
391<br />
(1’-3 3/8 " )<br />
NOTE:<br />
FINISHED FLOOR LEVELS INSIDE AND<br />
OUTSIDE <strong>VAULT</strong> MUST BE THE SAME.<br />
13 ( 1/2 ") TO 25 ( 1" )<br />
0<br />
0 0<br />
1 1 1 (4 3/8 " ) WALL<br />
FINISH SHOWN<br />
G.C. TO PROVIDE AND INSTALL 13mm X 559mm X 1600mm<br />
( 1/2 " X 1’-10" X 5’-3") BED PLATE WITH #5 ROD FOR<br />
ANCHORING (TYPICAL FOUR CORNERS)<br />
WALL FINISH APPLIED AFTER<br />
<strong>VAULT</strong> DOOR IS INSTALLED,<br />
GROUTED AND TRIMMED<br />
1 1 1 mm (4 3/8 ") WALL FINISH<br />
SHOWN<br />
STANDARD SPOKED HANDLE<br />
(SHOWN)<br />
0<br />
64<br />
2 1/2 ")<br />
<strong>VAULT</strong> DOOR LOCATION<br />
38mm X 76mm X 2244mm<br />
( 1 1/2 " X 3" X 7’-4 3/8 ")<br />
CHANNEL WELDED TO WALL PANEL<br />
0<br />
0<br />
WALL PANEL<br />
0<br />
76<br />
(3")<br />
0<br />
9mm X 76mm ( 3/8 " X 3")<br />
SHOE PROVIDED AND<br />
INSTALLED BY DIEBOLD<br />
WALL FINISH APPLIED AFTER <strong>VAULT</strong> DOOR IS INSTALLED,<br />
GROUTED AND TRIMMED 1 1 1 mm (4 3/8 ") WALL FINISH SHOWN<br />
0<br />
0
DIMENSIONS IN MILLIMETRES<br />
( DIMENSIONS IN FEET-INCHES )<br />
THIRD ANGLE<br />
PROJECTION<br />
"ALL DIMENSIONS AND DESIGN CRITERIA<br />
R<br />
SUBJECT TO CHANGE WITHOUT NOTICE." PAGE 2 OF 4 R<br />
FILE NO. 186-191 REV. 2<br />
0<br />
0<br />
A<br />
B<br />
FINISH FLOOR<br />
THICKNESS<br />
TOP OF FLOOR COVERING<br />
SHIM THICKNESS<br />
13 ( 1/2 ") TO 25 ( 1" )<br />
TOP OF ROUGH FLOOR<br />
SEE DETAIL #1<br />
WALL FINISH APPLIED AFTER<br />
<strong>VAULT</strong> DOOR IS INSTALLED,<br />
GROUTED AND TRIMMED<br />
1 1 1 mm (4 3/8 ") WALL FINISH<br />
SHOWN<br />
GENERAL CONTRACTOR NOTE<br />
IT IS "MANDATORY" THAT THE OWNERS GENERAL CONTRACTOR GROUT<br />
IN THE SPACE BETWEEN VESTIBULE AND CONCRETE WALL PANEL<br />
AFTER <strong>VAULT</strong> DOOR IS INSTALLED AND APPROVED BY DIEBOLD. GROUT<br />
TO CONSIST OF CLEAN SAND AND CEMENT USING FORMULATION TO<br />
PROVIDE AT LEAST 3,000 P. S. I. ( EQUIVALENT TO 6 BAG MIX ).<br />
CAUTION: GROUTING USING MECHANICAL OR HYDRAULIC METHODS<br />
MAY RESULT IN DAMAGE TO THE <strong>VAULT</strong> DOOR.<br />
NOTE:<br />
0<br />
13 ( 1/2 ") BEDPLATE<br />
0 0<br />
2244 (7’-4 3/8 ")<br />
0<br />
SEE DETAIL #2 AND #3<br />
WALL FINISH APPLIED AFTER <strong>VAULT</strong> DOOR IS INSTALLED 1 1 1mm (4 3/8 ") WALL FINISH SHOWN<br />
LC<br />
EMERGENCY <strong>VAULT</strong><br />
VENTILATOR<br />
WALL OPENING 0<br />
13 ( 1/2 ")<br />
0 (0")<br />
0<br />
2205 (7’-2 13/16 " ) JAMB TRIM<br />
0<br />
124 (4 7/8 ")<br />
24 ( 15/16 " )<br />
0<br />
0<br />
DOOR<br />
2057 (6’-9")<br />
0<br />
0<br />
1460 (4’-9 1/2 ") JAMB TRIM<br />
16 ( 5/8 ") 19 ( 3/4 ") 22 ( 7/8 ") 25 ( 1")<br />
3 ( 1/8 ") 6 ( 1/4 ") 10 ( 3/8 ") 13 ( 1/2 ")<br />
0<br />
171<br />
(6 3/4 ")<br />
0<br />
1988 (6’-6 1/4 ") VESTIBULE CLEAR OPENING<br />
0<br />
SECTION<br />
19 ( 3/4 ")<br />
0<br />
2197 (7’-2 1/2 ") VESTIBULE STAINLESS TRIM<br />
0<br />
E.C. TO PROVIDE AND<br />
INSTALL JUNCTION BOXES<br />
FOR POWER AND ALARM<br />
AT CONDUIT PENETRATIONS<br />
IN DOOR HEADER PANEL<br />
DAYGATE<br />
DAYGATE IN<br />
"OPEN POSITION"<br />
G.C. TO PROVIDE AND INSTALL 13mm X 559mm X 1600mm<br />
( 1/2 " X 1’-10" X 5’-3") BED PLATE WITH #5 ROD FOR<br />
ANCHORING (TYPICAL FOUR CORNERS)<br />
GROUT (SEE GENERAL<br />
CONTRACTOR NOTE)<br />
0<br />
CONCRETE<br />
VESTIBULE<br />
SETTING DETAIL FOR 1 1 1 mm (4 3/8 ") WALL FINISH SHOWN<br />
OWNER’S G.C. TO VERIFY FLOOR COVERING THICKNESS TO BE<br />
APPLIED INSIDE AND OUTSIDE <strong>VAULT</strong>. OWNER’S G.C. TO PREPARE<br />
FLOOR AS REQUIED SO FINISHED FLOOR HEIGHT MEETS OR IS<br />
FEATHERED TO EDGE OF <strong>VAULT</strong> DOOR SILL HEIGHT, BUT DOES NOT<br />
EXCEED TOP OF SILL PLATE<br />
300 ( 1 1 13/16 ")<br />
FINISH FLOOR MATERIAL INSIDE AND OUTSIDE<br />
<strong>VAULT</strong> SHOULD MEET OR BE FEATHERED TO<br />
THIS EDGE OF <strong>VAULT</strong> DOOR SILL PLATE<br />
FINISH<br />
FLOOR<br />
A<br />
0<br />
TOP OF<br />
ROUGH FLOOR<br />
0<br />
0 0<br />
13 ( 1/2 ") BED<br />
PLATE<br />
0<br />
13 ( 1/2 ")<br />
0 0<br />
DETAIL #3<br />
0<br />
1 14<br />
(4 1/2 ")<br />
0<br />
1448 (4’-9") VESTIBULE STAINLESS TRIM<br />
0 0<br />
EMERGENCY <strong>VAULT</strong><br />
VENTILATOR<br />
INTERIOR <strong>ELEVATION</strong><br />
0<br />
2244 (7’-4 3/8 ")<br />
WALL OPENING<br />
DETAIL #2<br />
0<br />
2205 (7’-2 13/16 ")<br />
JAMB TRIM<br />
DOOR SILL<br />
PLATE<br />
13 ( 1/2 ")<br />
0<br />
0<br />
DETAIL #1<br />
LIFT FOR AIR<br />
1600 (5’-3") BED PLATE0<br />
0 0<br />
0<br />
19 ( 3/4 ")<br />
STEEL SILL<br />
SHIM<br />
B THICKNESS<br />
0<br />
2197 (7’-2 1/2 ") VESTIBULE STAINLESS TRIM<br />
0
DIMENSIONS IN MILLIMETRES<br />
( DIMENSIONS IN FEET-INCHES )<br />
THIRD ANGLE<br />
PROJECTION<br />
PAGE 3 OF 4<br />
"ALL DIMENSIONS AND DESIGN CRITERIA<br />
SUBJECT TO CHANGE WITHOUT NOTICE."<br />
FILE NO. 186-191 REV. 2<br />
0<br />
0<br />
64 (2 1/2 ")<br />
WALL PANEL<br />
CALL 1-800-999-3600<br />
0<br />
216<br />
(8 1/2 ")<br />
0<br />
0<br />
279<br />
( 1 1")<br />
0<br />
13mm ( 1/2 ") BED PLATE<br />
0<br />
9mm ( 3/8 ") SHOE<br />
0<br />
559 (1’-10")<br />
BED PLATE<br />
0<br />
0<br />
0<br />
2244 (7’-4 3/8 ") WALL OPENING<br />
0<br />
R<br />
00<br />
1524 (5’-0") WALL OPENING 00<br />
0<br />
INSIDE <strong>VAULT</strong><br />
38 (1 1/2 ") 38 (1 1/2 ")<br />
1600 (5’-3") BED PLATE<br />
<strong>PLAN</strong> <strong>VIEW</strong><br />
00 1524 (5’-0") WALL OPENING 00<br />
38 (1 1/2 ")<br />
0 1600 (5’-3") BED PLATE<br />
0<br />
<strong>FRONT</strong> <strong>ELEVATION</strong><br />
<strong>AMERICAN</strong> <strong>VAULT</strong> DOOR<br />
#154-82 CLASS 1 WITH RAISED SILL WALL OPENING<br />
DETAILS FOR (5) SIDED CLASS I SUPER STRENGTH MVS<br />
GENERAL CONTRACTOR NOTE<br />
38 (1 1/2 ")<br />
0<br />
0<br />
0<br />
9mm X 76mm ( 3/8 " X 3")<br />
SHOE PROVIDED AND<br />
INSTALLED BY DIEBOLD<br />
G.C. TO PROVIDE AND INSTALL<br />
13mm X 559mm X 1600mm<br />
( 1/2 " X 1’-10" X 5’-3") BED<br />
PLATE WITH #5 ROD FOR<br />
ANCHORING (TYPICAL FOUR<br />
CORNERS)<br />
DIEBOLD IS NOT RESPONSIBLE FOR STRUCTURAL DESIGN OF THE BUILDING FLOOR BELOW THE MODULAR <strong>VAULT</strong>.<br />
DIEBOLD RECOMMENDS THE PURCHASER HIRE A LICENSED STRUCTRUAL ENGINEER/ARCHITECT FOR EXACT FLOOR<br />
SPECIFICATIONS AND CONSTRUCTION METHODS IN THE AREA SUPPORTING DIEBOLD MODULAR <strong>VAULT</strong>.<br />
THE GENERAL CONTRACTOR (G.C.) SHALL PROVIDE A FLOOR TO SUPPORT THE WEIGHT OF MODULAR <strong>VAULT</strong> AND<br />
<strong>VAULT</strong> DOOR. IF <strong>VAULT</strong> IS USED FOR STORAGE OF S. D. BOXES ALLOW 500 LBS. PER SQ. FT. (LIVE LOAD).<br />
FLOOR SHOULD PROVIDE THE SAME SECURITY AS DIEBOLD <strong>VAULT</strong> PANELS (CLASS 1 ) AND COMPLY WITH THE<br />
ASTM DESIGNATION F 1090-87 ( 305 (12") REINFORCED CONCRETE; 3 ROWS RE-BAR GRID, 102 (4") ON CENTER OR<br />
2 ROWS EXPANDED WIRE MESH - ISO 5R)<br />
G.C. SHALL ALSO LOCATE, PROVIDE AND INSTALL BED PLATE 13mm X 559mm X 1600mm ( 1/2 " X 1’-10" X 5’-3")<br />
FLUSH WITH TOP OF ROUGH FLOOR AT EACH <strong>VAULT</strong> DOOR.<br />
C LWALL OPENING<br />
78 (7")<br />
0 0 0 0 0<br />
78 (7") 89 (3 1/2 ")<br />
0 0<br />
1524 (5’-0") WALL OPENING<br />
0<br />
0<br />
102 (4")<br />
TM<br />
NOTE:<br />
WALL FINISH APPLIED AFTER<br />
<strong>VAULT</strong> DOOR IS INSTALLED,<br />
GROUTED AND TRIMMED<br />
1 1 1 mm (4 3/8 ") WALL FINISH<br />
SHOWN<br />
<strong>VAULT</strong> HEADER PANEL<br />
G.C. TO PROVIDE AND INSTALL<br />
13mm X 559mm X 1600mm<br />
( 1/2 " X 1’-10" X 5’-3") BED<br />
PLATE WITH #5 ROD FOR<br />
ANCHORING (TYPICAL FOUR<br />
CORNERS)<br />
0<br />
0<br />
0<br />
0<br />
9mm X 76mm ( 3/8 " X 3")<br />
SHOE PROVIDED AND<br />
INSTALLED BY DIEBOLD<br />
WALL FINISH<br />
AS REQUIRED<br />
(4) 25mm (1") DIA. CONDUITS PROVIDED IN <strong>VAULT</strong> HEADER<br />
PANEL (STANDARD LOCATION). OPTIONAL CONDUIT<br />
LOCATION CAN BE IN CEILING OR WALL PANEL<br />
(1) 25mm (1") DIA. CONDUIT FOR ELECTRICAL REQUIREMENTS WITHIN<br />
<strong>VAULT</strong>, INCLUDING <strong>VAULT</strong> DOOR EMERGENCY <strong>VAULT</strong> VENTILATOR,<br />
ALARM CONTROL CABINET, LIGHT FIXTURES AND ANY OTHER<br />
ELECTRICAL REQUIREMENTS. <strong>VAULT</strong> DOOR EMERGENCY <strong>VAULT</strong><br />
VENTILATOR AND ALARM CONTROL CABINET REQUIRE SEPARATE<br />
120 VAC, 60Hz, 20 AMP BRANCH CIRCUIT ( UNSWITCHED) WITH<br />
GREEN WIRE GROUND.<br />
(3) 25mm (1") DIA. CONDUITS FOR LOW VOLTAGE ALARM AND<br />
COMMUNICATION CABLES.<br />
NOTE:<br />
FINISHED FLOOR LEVELS INSIDE AND<br />
OUTSIDE <strong>VAULT</strong> MUST BE THE SAME.
DIMENSIONS IN MILLIMETRES<br />
( DIMENSIONS IN FEET-INCHES )<br />
THIRD ANGLE<br />
PROJECTION<br />
"ALL DIMENSIONS AND DESIGN CRITERIA<br />
SUBJECT TO CHANGE WITHOUT NOTICE."<br />
R<br />
PAGE 4 OF 4<br />
FILE NO. 186-191 REV. 2<br />
140 (5 1/2 ") HEADER PANEL<br />
WALL FINISH APPLIED AFTER<br />
<strong>VAULT</strong> DOOR IS INSTALLED,<br />
GROUTED AND TRIMMED<br />
1 1 1 mm (4 3/8 ") WALL FINISH<br />
SHOWN<br />
FLOOR FINISH<br />
13 ( 1/2 ") TO 25 ( 1" )<br />
0<br />
2244 (7’-4 3/8 ") WALL OPENING<br />
0 0 0<br />
64mm (2 1/2 ")<br />
WALL PANEL<br />
0<br />
0<br />
279 (1 1")<br />
0<br />
0<br />
0<br />
0<br />
0<br />
0<br />
0<br />
0<br />
559 (1’-10")<br />
BED PLATE<br />
0<br />
0<br />
0<br />
235<br />
(8 1/2 ")<br />
0<br />
0<br />
0 0<br />
102<br />
(4")<br />
GENERAL CONTRACTOR NOTE<br />
IT IS "MANDATORY" THAT THE OWNERS GENERAL CONTRACTOR GROUT IN THE SPACE BETWEEN VESTIBULE AND<br />
CONCRETE WALL PANELS AFTER <strong>VAULT</strong> DOOR IS INSTALLED AND APPROVED BY DIEBOLD. GROUT TO CONSIST OF<br />
CLEAN SAND AND CEMENT USING FORMULATION TO PROVIDE AT LEAST 3,000 P. S. I. ( EQUIVALENT TO 6 BAG MIX ).<br />
CAUTION: GROUTING USING MECHANICAL OR HYDRAULIC METHODS MAY RESULT IN DAMAGE TO THE <strong>VAULT</strong> DOOR.<br />
NOTE:<br />
FINISHED FLOOR LEVELS INSIDE AND<br />
OUTSIDE <strong>VAULT</strong> MUST BE THE SAME.<br />
G.C. TO PROVIDE AND INSTALL<br />
0<br />
0<br />
13mm X 559mm X 1600mm<br />
( 1/2 " X 1’-10" X 5’-3") BED<br />
PLATE WITH #5 ROD FOR<br />
ANCHORING (TYPICAL FOUR<br />
CORNERS)<br />
WALL FINISH APPLIED AFTER<br />
<strong>VAULT</strong> DOOR IS INSTALLED,<br />
GROUTED AND TRIMMED<br />
1 1 1 mm (4 3/8 ") WALL FINISH<br />
SHOWN<br />
25mm ( 1 ")<br />
MAXIMUM FLOOR<br />
FINISH<br />
0<br />
0<br />
E.C. TO PROVIDE AND INSTALL JUNCTION BOXES<br />
AT (4) 25mm (1") DIA. CONDUIT PENETRATIONS IN<br />
<strong>VAULT</strong> HEADER PANEL<br />
WALL FINISH AS REQUIRED<br />
INSIDE <strong>VAULT</strong><br />
9mm X 76mm ( 3/8 " X 3")<br />
SHOE PROVIDED AND<br />
INSTALLED BY DIEBOLD<br />
76mm (3") CHANNEL<br />
38mm X 76mm X 2235mm<br />
( 1 1/2 " X 3" X 7’-4")<br />
CHANNEL WELDED TO WALL PANEL<br />
0<br />
9 ( 3/8 ") SHOE<br />
64 (2 1/2 ") WALL PANELS<br />
0<br />
G.C. TO PROVIDE AND INSTALL<br />
13mm X 559mm X 1600mm<br />
( 1/2 " X 1’-10" X 5’-3") BED<br />
PLATE WITH #5 ROD FOR<br />
ANCHORING (TYPICAL FOUR<br />
CORNERS)<br />
13 ( 1/2 ") BEDPLATE<br />
0<br />
64mm (2 1/2 ")<br />
WALL PANEL<br />
279 (1 1")<br />
FLOOR FINISH<br />
13 ( 1/2 ") TO 25 ( 1" )<br />
0<br />
0<br />
0<br />
0<br />
SEE DETAIL "A"<br />
SECTION PERSPECTIVE<br />
0<br />
0<br />
559 (1’-10") BED PLATE<br />
DETAIL "A"<br />
0<br />
0<br />
0<br />
216 (8 1/2 ")<br />
WALL FINISH AS REQUIRED<br />
76mm (3") CHANNEL<br />
0<br />
0<br />
0 0<br />
0<br />
0<br />
9mm ( 3/8 ") SHOE<br />
INSIDE <strong>VAULT</strong><br />
0<br />
0<br />
9mm X 76mm ( 3/8 " X 3")<br />
SHOE PROVIDED AND<br />
13mm ( 1/2 ") BED PLATE<br />
INSTALLED BY DIEBOLD<br />
FLOOR FINISH<br />
13 ( 1/2 ") TO 25 ( 1" )<br />
0<br />
0<br />
76 (3") CEILING PANELS<br />
9mm X 76mm ( 3/8 " X 3")<br />
SHOE PROVIDED AND<br />
INSTALLED BY DIEBOLD