L556<strong>467</strong><br />

DIMENSIONS IN MILLIMETRES<br />

(DIMENSIONS IN INCHES)<br />

THIRD ANGLE<br />

"ALL DIMENSIONS AND DESIGN CRITERIA PROJECTION<br />

SUBJECT TO CHANGE WITHOUT NOTICE" PAGE 1 OF 4<br />

FILE NO. <strong>177</strong>-<strong>467</strong> REV. 5<br />

CALL 1-800-999-3600<br />

922<br />

31<br />

")<br />

16<br />

5<br />

(36<br />

")<br />

4<br />

1<br />

(1<br />

A<br />

B<br />

C<br />

D<br />

891<br />

")<br />

16<br />

1<br />

(35<br />

OPTIONAL CONSUMER BAR<br />

CODE SCANNER<br />

(SEE "CAUTION" LABEL<br />

ON PAGE 2 OF 4)<br />

13<br />

1<br />

( 2")<br />

470<br />

R<br />

1<br />

(18 2")<br />

794<br />

1<br />

(31 4")<br />

768<br />

1<br />

(30 4")<br />

PLAN VIEW<br />

794<br />

1<br />

(31 4")<br />

13<br />

1<br />

( 2")<br />

324<br />

3<br />

(12 4")<br />

OPTEVA 720 ADVANCED FUNCTION LOBBY ATM<br />

REAR LOAD<br />

795<br />

1594<br />

")<br />

16<br />

5<br />

(31<br />

19<br />

")<br />

4<br />

3<br />

(62<br />

95<br />

890<br />

")<br />

4<br />

3<br />

(<br />

1613<br />

")<br />

16<br />

1<br />

(35<br />

")<br />

4<br />

3<br />

(3<br />

")<br />

2<br />

1<br />

(63<br />

fi<br />

9<br />

5 HIGH WITH 40mm (1 16")<br />

SAFE<br />

E<br />

CONSULT WITH DIEBOLD INSTALLATION/SERVICE<br />

BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.<br />

PLEASE SEE PLANNING AND SITE PREPARATION GUIDE<br />

TP-820717-001.<br />

AIR VENTS<br />

3<br />

(4 8")<br />

3<br />

(4 8")<br />

FRONT ELEVATION SIDE ELEVATION<br />

A<br />

B<br />

C<br />

E<br />

CONSUMER ACCESS DIMENSIONS<br />

TOP OF MONITOR<br />

TOP FUNCTION KEY<br />

RECEIPT PRINTER<br />

D ADVANCED FUNCTION DISPENSER<br />

CARD READER<br />

111<br />

1613<br />

111<br />

")<br />

2<br />

1<br />

(63<br />

217<br />

9<br />

(8 16")<br />

906<br />

11<br />

(35 16")<br />

3<br />

(13 8")<br />

795<br />

5<br />

(31 16")<br />

906<br />

795<br />

5<br />

(31 16")<br />

340<br />

11<br />

(35 16")<br />

238<br />

3<br />

(9 8")<br />

HEIGHT<br />

1284mm<br />

1<br />

(50 2")<br />

1200mm<br />

1<br />

(47 4")<br />

1001mm<br />

7<br />

(39 16")<br />

811mm<br />

7<br />

(31 8")<br />

1001mm<br />

7<br />

(39 16")<br />

105<br />

1410<br />

")<br />

8<br />

1<br />

(4<br />

")<br />

2<br />

1<br />

(55<br />

79<br />

")<br />

8<br />

1<br />

(3<br />

795<br />

799<br />

DEPTH<br />

198mm<br />

13<br />

(7 16")<br />

146mm<br />

3<br />

(5 4")<br />

111mm<br />

3<br />

(4 8")<br />

HEIGHT - FROM BOTTOM OF SAFE<br />

DEPTH - FROM FRONT EDGE OF BEZEL<br />

")<br />

16<br />

5<br />

(31<br />

")<br />

16<br />

7<br />

(31<br />

0<br />

( 0")<br />

111mm<br />

3<br />

(4 8")<br />

1594<br />

19<br />

")<br />

4<br />

3<br />

(62<br />

")<br />

4<br />

3<br />

(<br />

1613<br />

")<br />

2<br />

1<br />

(63


DIMENSIONS IN MILLIMETRES<br />

(DIMENSIONS IN INCHES)<br />

THIRD ANGLE<br />

PROJECTION<br />

PAGE 2 OF 4<br />

SUBJECT TO CHANGE WITHOUT NOTICE"<br />

"ALL DIMENSIONS AND DESIGN CRITERIA<br />

FILE NO. <strong>177</strong>-<strong>467</strong> REV. 5<br />

1<br />

2<br />

3<br />

4<br />

5<br />

CONDUIT AND JUNCTION BOX REQUIREMENTS<br />

NOTE:<br />

SIGNAL CABLE RUN CONSTRAINTS<br />

THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS<br />

OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND<br />

ELECTRICAL EQUIPMENT CABLE RUN.<br />

TYPE OF ELECTRICAL RUN<br />

FLUORESCENT, NEON OR INCANDESCENT<br />

LIGHTING FIXTURES<br />

UNSHIELDED POWER LINE OR<br />

ELECTRICAL EQUIPMENT<br />

CONDUIT<br />

19<br />

")<br />

4<br />

3<br />

(<br />

1613<br />

1<br />

(63 2")<br />

1594<br />

25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET<br />

1<br />

JUNCTION BOX TO 102mm (4") SQ. X 54mm (2 8")<br />

DEEP JUNCTI0N<br />

BOX (ALL BY OWNER’S E.C.). DIEBOLD TO PROVIDE FLAT COVER<br />

WITH TAMPER SWITCH.<br />

WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED TO<br />

3<br />

THE ATM, OWNER’S E.C. TO RUN 19mm ( 4")<br />

METAL CONDUIT FROM<br />

1<br />

102mm (4") SQ. X 54mm (2 8")<br />

DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY.<br />

3<br />

OWNER’S E.C. TO RUN 19mm ( 4")<br />

LIQUID TIGHT FLEX METAL<br />

3<br />

CONDUIT OR 19mm ( 4")<br />

RIGID CONDUIT FROM JUNCTION BOX<br />

TO CABLE CONNECTION PLATE.<br />

3<br />

19mm ( 4")<br />

METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY<br />

1<br />

TO 102mm (4") SQ. X 54mm (2 8")<br />

DEEP JUNCTION BOX WITH<br />

RECEPTACLE WITHIN 2210mm (87") OF SIDE CONNECTING PLATE.<br />

BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY<br />

(ALL BY OWNER’S E.C.) (SEE POWER REQUIREMENTS).<br />

OWNER’S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY<br />

SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD<br />

LENGTH 2184mm (86") FROM SIDE OF UNIT.<br />

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF<br />

CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE<br />

PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA.<br />

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR<br />

NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH<br />

EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.<br />

UNSHIELDED POWER LINES OR<br />

ELECTRICAL EQUIPMENT WITH<br />

SIGNAL CABLES ENCLOSED IN<br />

GROUNDED CONDUIT<br />

POWER LINES IN GROUNDED CONDUIT<br />

WITH SIGNAL CABLES IN GROUNDED<br />

SIGNAL CABLE INSTALLATION CONSTRAINTS:<br />

RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE<br />

POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION<br />

AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION.<br />

21<br />

")<br />

16<br />

13<br />

(<br />

40<br />

")<br />

4<br />

3<br />

(62<br />

")<br />

16<br />

9<br />

(1<br />

63<br />

1<br />

(2 2")<br />

1533<br />

")<br />

8<br />

3<br />

(60<br />

13<br />

1<br />

( 2")<br />

BELOW 2 KVA 2-5 KVA ABOVE 5 KVA<br />

679<br />

3<br />

(26 4")<br />

768<br />

1<br />

(30 4")<br />

794<br />

1<br />

(31 4")<br />

13<br />

1<br />

( 2")<br />

BACK ELEVATION<br />

SEPARATION FROM OTHER CABLES<br />

127mm (5") 127mm (5") 127mm (5")<br />

127mm (5") 305mm (1’-0") 610mm (2’-0")<br />

1<br />

64mm (2 2")<br />

152mm (6") 305mm (1’-0")<br />

3<br />

30mm (1 16")<br />

76mm (3") 152mm (6")<br />

51<br />

(2")<br />

AIR VENTS<br />

4<br />

1<br />

2<br />

4<br />

1<br />

5<br />

3<br />

POWER REQUIREMENTS:<br />

THE ATM REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE.<br />

WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT<br />

GROUND IS NOT ACCEPTABLE). THE ATM WILL PROVIDE A POWER CORD WITH A COUNTRY<br />

SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW.<br />

100-127 VAC (+6%, -10%) AT 50 (–1%) Hz, SINGLE-PHASE<br />

100-127 VAC (+6%, -10%) AT 60 (–1%) Hz, SINGLE-PHASE<br />

200-240 VAC (–10%) AT 50 (–1%) Hz, SINGLE-PHASE<br />

200-240 VAC (–10%) AT 50 (–1%) Hz, SINGLE-PHASE<br />

POWER TO THE ATM IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A SAFETY<br />

QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT THE<br />

ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER)<br />

MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.<br />

100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES<br />

200-240 VAC (–10%) SERVICE, DISCONNECT AT 10 AMPERES<br />

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE<br />

POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO<br />

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.<br />

POWER USAGE:<br />

MACHINE STATUS<br />

IDLE (NO TRANSACTION)<br />

TRANSACTION (DISPENSE<br />

OR BULK NOTE) IN PROGRESS<br />

RAPID PROCESSING<br />

TRANSACTION IN PROGRESS<br />

CONFIGURATION:<br />

1<br />

2<br />

RAPID PROCESSING - SYSTEMS CONFIGURED FOR SIMULTANEOUS IDM (INTELLIGENT<br />

DEPOSITORY MODULE) AND ENA (ENHANCED NOTE ACCEPTOR) OR IDM AND BNA (BULK<br />

NOTE ACCEPTOR) OPERATIONS.<br />

1<br />

2<br />

971 BTU/HR DISPENSING<br />

648 BTU/HR IDLE<br />

1,875 BTU/HR RAPID PROCESSING<br />

781 BTU/HR IDLE<br />

2,094 BTU/HR RAPID PROCESSING<br />

OPERATING ENVIRONMENT:<br />

SAFE LOCATION<br />

104<br />

79<br />

")<br />

8<br />

1<br />

(4<br />

")<br />

8<br />

1<br />

(3<br />

AIR VENTS<br />

POWER CORD<br />

1 2<br />

190 WATTS<br />

285 WATTS<br />

550 WATTS 614 WATTS<br />

10” C TO 38” C (50” F TO 100” F)<br />

RELATIVE HUMIDITY (NON-CONDENSING)<br />

20 TO 80% AT 32” C (90” F),<br />

20 TO 55% AT 38” C (100” F)<br />

238<br />

3<br />

(9 8")<br />

378<br />

7<br />

(14 8")<br />

38<br />

1<br />

(1 2")<br />

229 WATTS<br />

349 WATTS<br />

PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL<br />

PRINTER, 80mm THERMAL RECEIPT PRINTER, STANDARD DEPOSITORY AND 5 HIGH AFD.<br />

PROCESSOR, SVD LCD CONSUMER DISPLAY, MOTORIZED CARD READER, JOURNAL PRINTER,<br />

80mm THERMAL RECEIPT PRINTER, IDM, 5 HIGH AFD, AND BULK NOTE ACCEPTOR.<br />

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN<br />

THE ATM, AND THE TYPE OF TRANSACTION THE ATM IS PERFORMING.<br />

HEAT OUTPUT CONFIGURATION:<br />

1,190 BTU/HR BULK NOTE ACCEPTING<br />

WEIGHT OF UNIT:<br />

1,000 kg (2,200 LBS.)<br />

CAUTION LABEL<br />

340<br />

3<br />

(13 8")<br />

795<br />

5<br />

(31 16")<br />

379<br />

217<br />

1<br />

(8 2")<br />

15<br />

(14 16")<br />

SIDE ELEVATION


THIRD ANGLE<br />

DIMENSIONS IN MILLIMETRES<br />

"ALL DIMENSIONS AND DESIGN CRITERIA<br />

PAGE 3 OF 4<br />

PROJECTION<br />

(DIMENSIONS IN INCHES)<br />

SUBJECT TO CHANGE WITHOUT NOTICE"<br />

FILE NO. <strong>177</strong>-<strong>467</strong> REV. 5<br />

CALL 1-800-999-3600<br />

NOTE:<br />

R<br />

SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND<br />

SERVICE. THESE DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO<br />

IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE<br />

RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE<br />

TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL<br />

BUILDING CONDITIONS.<br />

RECOMMENDED SERVICE AREA<br />

MINIMUM SERVICE AREA<br />

ALL ELECTRICAL AND DATA CABLES<br />

MUST ENTER UNIT IN THIS AREA<br />

fi<br />

OPTEVA 720 ADVANCED FUNCTION LOBBY ATM<br />

REAR LOAD<br />

1946<br />

2206<br />

9<br />

5 HIGH WITH 40mm ( 1 16")<br />

SAFE<br />

")<br />

8<br />

5<br />

(76<br />

")<br />

8<br />

7<br />

(86<br />

903<br />

891<br />

152<br />

1163<br />

891<br />

152<br />

")<br />

16<br />

9<br />

(35<br />

")<br />

16<br />

1<br />

(35<br />

(6")<br />

")<br />

16<br />

13<br />

(45<br />

")<br />

16<br />

1<br />

(35<br />

(6")<br />

321<br />

152<br />

418<br />

321<br />

152<br />

418<br />

")<br />

8<br />

5<br />

(12<br />

(6")<br />

")<br />

16<br />

7<br />

(16<br />

")<br />

8<br />

5<br />

(12<br />

(6")<br />

")<br />

16<br />

7<br />

(16<br />

543<br />

3<br />

(21 8")<br />

51<br />

(2")<br />

1413<br />

5<br />

(55 8")<br />

PLAN VIEW<br />

(SINGLE UNIT)<br />

(MINIMUM SERVICE AREA)<br />

543<br />

3<br />

(21 8")<br />

51<br />

(2")<br />

1413<br />

5<br />

(55 8")<br />

PLAN VIEW<br />

794<br />

1<br />

(31 4")<br />

794<br />

1<br />

(31 4")<br />

(SINGLE UNIT)<br />

(MINIMUM SERVICE AREA)<br />

76<br />

(3")<br />

76<br />

(3")


DIMENSIONS IN MILLIMETRES<br />

(DIMENSIONS IN INCHES)<br />

THIRD ANGLE<br />

PROJECTION<br />

PAGE 4 OF 4<br />

SUBJECT TO CHANGE WITHOUT NOTICE"<br />

"ALL DIMENSIONS AND DESIGN CRITERIA<br />

FILE NO. <strong>177</strong>-<strong>467</strong> REV. 5<br />

38<br />

")<br />

2<br />

1<br />

(1<br />

378<br />

379<br />

60<br />

")<br />

8<br />

7<br />

(14<br />

")<br />

16<br />

15<br />

(14<br />

3<br />

(2 8")<br />

1<br />

2<br />

1946<br />

")<br />

8<br />

5<br />

(76<br />

1<br />

1<br />

903<br />

891<br />

152<br />

")<br />

16<br />

9<br />

(35<br />

")<br />

16<br />

1<br />

(35<br />

(6")<br />

321<br />

152<br />

418<br />

5<br />

(18 16")<br />

")<br />

8<br />

5<br />

(12<br />

(6")<br />

")<br />

16<br />

7<br />

(16<br />

465<br />

768 SAFE<br />

1<br />

(30 4")<br />

541<br />

2<br />

CABLE ENTRY OPENING<br />

(SEE NOTE)<br />

1<br />

648<br />

1<br />

(25 2")<br />

5<br />

(21 16")<br />

51<br />

(2")<br />

940<br />

(37")<br />

303<br />

15<br />

(11 16")<br />

PLAN/SECTION SAFE FLOOR<br />

9<br />

(5) 40mm (1 16")<br />

DIA. RECESS<br />

3<br />

18mm ( 4")<br />

RECESS DEPTH<br />

7<br />

22mm ( 8")<br />

DIA. THROUGH-HOLE<br />

9<br />

(1) 65mm (2 16")<br />

DIA. RECESS<br />

3<br />

18mm ( 4")<br />

RECESS DEPTH<br />

7<br />

22mm ( 8")<br />

DIA. THROUGH-HOLE<br />

RECESS FOR SNAP OFF DETECTOR<br />

1<br />

1<br />

794<br />

1<br />

(31 4")<br />

174<br />

400<br />

222<br />

60<br />

")<br />

8<br />

7<br />

(6<br />

")<br />

4<br />

3<br />

(15<br />

")<br />

4<br />

3<br />

(8<br />

3<br />

(2 8")<br />

ANCHOR NOTES:<br />

5<br />

1. RECOMMENDED ANCHOR BOLT SIZE - M16 ( 8")<br />

(NOT SUPPLIED WITH ATM).<br />

99<br />

597<br />

99<br />

2. A CONCRETE OR MASONRY FLOOR AT LEAST 152mm (6") THICK IS RECOMMENDED.<br />

")<br />

8<br />

7<br />

(3<br />

")<br />

16<br />

9<br />

(23<br />

")<br />

8<br />

7<br />

(3<br />

943<br />

1<br />

(37 8")<br />

150<br />

SAFE<br />

795<br />

7<br />

(5 8")<br />

")<br />

16<br />

5<br />

(31<br />

3299<br />

7<br />

(129 8")<br />

794<br />

1<br />

(31 4")<br />

PLAN VIEW<br />

(ADJACENT UNITS)<br />

(MINIMUM SERVICE AREA)<br />

CABLE ENTRY NOTE:<br />

ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH<br />

A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES<br />

ENTERING THE CASH DISPENSER PASS THROUGH THE POWER<br />

CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE<br />

SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN ENTER<br />

FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH<br />

DISPENSER. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE<br />

OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH<br />

DISPENSER.<br />

POWER CABLE PLATE<br />

1<br />

(37 8")<br />

150<br />

943<br />

7<br />

(5 8")<br />

794<br />

1<br />

(31 4")<br />

1<br />

29mm (1 8")<br />

DIA. HOLE FOR<br />

ALARM CABLES (SIDE ENTRY)<br />

OPENING FOR POWER CORD<br />

AND DATA CABLES<br />

(SIDE ENTRY)<br />

473<br />

5<br />

(18 8")<br />

76<br />

(3")