177-467 rev. 5 - Diebold
177-467 rev. 5 - Diebold
177-467 rev. 5 - Diebold
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
DIMENSIONS IN MILLIMETRES<br />
(DIMENSIONS IN INCHES)<br />
THIRD ANGLE<br />
PROJECTION<br />
PAGE 4 OF 4<br />
SUBJECT TO CHANGE WITHOUT NOTICE"<br />
"ALL DIMENSIONS AND DESIGN CRITERIA<br />
FILE NO. <strong>177</strong>-<strong>467</strong> REV. 5<br />
38<br />
")<br />
2<br />
1<br />
(1<br />
378<br />
379<br />
60<br />
")<br />
8<br />
7<br />
(14<br />
")<br />
16<br />
15<br />
(14<br />
3<br />
(2 8")<br />
1<br />
2<br />
1946<br />
")<br />
8<br />
5<br />
(76<br />
1<br />
1<br />
903<br />
891<br />
152<br />
")<br />
16<br />
9<br />
(35<br />
")<br />
16<br />
1<br />
(35<br />
(6")<br />
321<br />
152<br />
418<br />
5<br />
(18 16")<br />
")<br />
8<br />
5<br />
(12<br />
(6")<br />
")<br />
16<br />
7<br />
(16<br />
465<br />
768 SAFE<br />
1<br />
(30 4")<br />
541<br />
2<br />
CABLE ENTRY OPENING<br />
(SEE NOTE)<br />
1<br />
648<br />
1<br />
(25 2")<br />
5<br />
(21 16")<br />
51<br />
(2")<br />
940<br />
(37")<br />
303<br />
15<br />
(11 16")<br />
PLAN/SECTION SAFE FLOOR<br />
9<br />
(5) 40mm (1 16")<br />
DIA. RECESS<br />
3<br />
18mm ( 4")<br />
RECESS DEPTH<br />
7<br />
22mm ( 8")<br />
DIA. THROUGH-HOLE<br />
9<br />
(1) 65mm (2 16")<br />
DIA. RECESS<br />
3<br />
18mm ( 4")<br />
RECESS DEPTH<br />
7<br />
22mm ( 8")<br />
DIA. THROUGH-HOLE<br />
RECESS FOR SNAP OFF DETECTOR<br />
1<br />
1<br />
794<br />
1<br />
(31 4")<br />
174<br />
400<br />
222<br />
60<br />
")<br />
8<br />
7<br />
(6<br />
")<br />
4<br />
3<br />
(15<br />
")<br />
4<br />
3<br />
(8<br />
3<br />
(2 8")<br />
ANCHOR NOTES:<br />
5<br />
1. RECOMMENDED ANCHOR BOLT SIZE - M16 ( 8")<br />
(NOT SUPPLIED WITH ATM).<br />
99<br />
597<br />
99<br />
2. A CONCRETE OR MASONRY FLOOR AT LEAST 152mm (6") THICK IS RECOMMENDED.<br />
")<br />
8<br />
7<br />
(3<br />
")<br />
16<br />
9<br />
(23<br />
")<br />
8<br />
7<br />
(3<br />
943<br />
1<br />
(37 8")<br />
150<br />
SAFE<br />
795<br />
7<br />
(5 8")<br />
")<br />
16<br />
5<br />
(31<br />
3299<br />
7<br />
(129 8")<br />
794<br />
1<br />
(31 4")<br />
PLAN VIEW<br />
(ADJACENT UNITS)<br />
(MINIMUM SERVICE AREA)<br />
CABLE ENTRY NOTE:<br />
ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH<br />
A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES<br />
ENTERING THE CASH DISPENSER PASS THROUGH THE POWER<br />
CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE<br />
SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN ENTER<br />
FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH<br />
DISPENSER. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE<br />
OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH<br />
DISPENSER.<br />
POWER CABLE PLATE<br />
1<br />
(37 8")<br />
150<br />
943<br />
7<br />
(5 8")<br />
794<br />
1<br />
(31 4")<br />
1<br />
29mm (1 8")<br />
DIA. HOLE FOR<br />
ALARM CABLES (SIDE ENTRY)<br />
OPENING FOR POWER CORD<br />
AND DATA CABLES<br />
(SIDE ENTRY)<br />
473<br />
5<br />
(18 8")<br />
76<br />
(3")