Mechanical Testing Framework<br />

A –Procedure for laboratory testing<br />

1) Objective Test<br />

The purpose <strong>of</strong> this regulation is to obtain optimum quality <strong>of</strong> sport facilities<br />

implemented to good technical practice <strong>of</strong> judo. It specifically targets aspects <strong>of</strong><br />

security to prevent incidents <strong>and</strong> accidents that may affect <strong>the</strong> health <strong>of</strong> judokas.<br />

Seven parameters will be monitored:<br />

• Dimensions (length, width <strong>and</strong> thickness)<br />

• Uniformity<br />

• Absorption (maximum deceleration)<br />

• Energy <strong>of</strong> restitution (coefficient <strong>of</strong> restitution)<br />

• Friction (coefficient <strong>of</strong> friction <strong>of</strong> <strong>the</strong> base)<br />

• Friction characteristics <strong>of</strong> <strong>the</strong> upper surface<br />

• Static Stiffness<br />

The tests will be conducted in accordance with <strong>the</strong> requirements <strong>of</strong> st<strong>and</strong>ard NF EN<br />

12503-3 on <strong>the</strong> judo mat. Additive requirements (see part 5) have to be considered in<br />

compliance with this regulation.<br />

4) Performancs Requirements according to EN 12503-3<br />

4.1 Determination <strong>of</strong> basic characteristics (in cm)<br />

(According to appendix A <strong>of</strong> st<strong>and</strong>ard EN 12503-3)<br />

l1<br />

l2<br />

L1<br />

L3<br />

L2<br />

l3<br />

2) Procedure<br />

The test itself consists <strong>of</strong> six parts:<br />

Define <strong>the</strong> dimensions <strong>of</strong> <strong>the</strong> tatami (paragraph 4.1).<br />

Control <strong>the</strong> uniformity by performing a first set <strong>of</strong> impacts across <strong>the</strong> mat with an<br />

indentor <strong>of</strong> 78 mm in diameter <strong>and</strong> a drop height <strong>of</strong> 40 cm (paragraph 4.2).<br />

Determine <strong>the</strong> values <strong>of</strong> two parameters (maximum deceleration <strong>and</strong> coefficient <strong>of</strong><br />

restitution) by performing a second set <strong>of</strong> impacts using two indentors <strong>and</strong> two heights<br />

(paragraph 4.3).<br />

• Diameter <strong>of</strong> indentors: 43 mm <strong>and</strong> 116 mm<br />

• Height <strong>of</strong> drop: 20 cm <strong>and</strong> 60 cm<br />

Control <strong>the</strong> quality <strong>of</strong> <strong>the</strong> slip by making a skid test using <strong>the</strong> pendulum RRL<br />

(paragraph 4.4).<br />

Determine <strong>the</strong> top friction (paragraph 4.5).<br />

Determine <strong>the</strong> static stiffness (paragraph 4.6).<br />

3) Test conditions<br />

Conditioning air<br />

As provided in Chapter 6 <strong>of</strong> <strong>the</strong> st<strong>and</strong>ard EN 12503-4, <strong>the</strong> temperature condition <strong>of</strong><br />

<strong>the</strong> tests is: (21 +/- 3) °C.<br />

The length must be <strong>of</strong> 1 or 2 meters, <strong>the</strong> width must be <strong>of</strong> 1 meter <strong>and</strong> thickness<br />

must be 40, 50 or 60 mm. The tolerance on <strong>the</strong> length <strong>and</strong> width must be lower than<br />

0.5 cm <strong>and</strong> <strong>the</strong> tolerance <strong>of</strong> <strong>the</strong> thickness lower than 3%.<br />

The average value <strong>of</strong> each parameter will be expressed in test report with maximum<br />

value <strong>of</strong> tolerance.<br />

Any o<strong>the</strong>r size announced by <strong>the</strong> manufacturer must be made by an <strong>of</strong>ficial dem<strong>and</strong> to<br />

IFJ. The testing laboratory is able to participate in <strong>the</strong> decision <strong>of</strong> acceptability <strong>of</strong> this new<br />

size (measurement <strong>of</strong> performances <strong>and</strong> expert opinion) while maintaining its integrity <strong>and</strong><br />

independence. It will <strong>the</strong>n be possible to waive this requirement. If <strong>the</strong> applicant does not<br />

reply within a month, <strong>the</strong> new dimensions will be accepted by default.<br />

Results given in Report<br />

Mat reference Normative dimensions Tolerance on dimensions Measured dimensions<br />

Length (cm) Multiple <strong>of</strong> 1 ± 0,5 cm xx,x ± x,x cm<br />

Width (cm) Multiple <strong>of</strong> 1 ± 0,5 cm xx,x ± x,x cm<br />

Thickness (mm) 40 or 50 or 60 ± 3 % xx,x ± x,x mm<br />

Sample conform<br />