Setting :<br />
Normal : 124V +/- 0.5 V at 19 Amp.<br />
And at 1500 RPM<br />
Facility available for setting:<br />
120V,122V & 124V<br />
Load Current : 42 Amp (Maximum)<br />
Battery charging current: 24 Amp (Max.)<br />
3.3 Main Components <strong>of</strong> ERRU :<br />
The main components <strong>of</strong> the ERRU are as follows<br />
• Terminal Box<br />
• Power Unit<br />
• Universal Voltage Controller (UVC)<br />
• Static Over Voltage Protection (OVP)<br />
• Emergency Field Extension with interface<br />
• High Reliable Components<br />
1. Half Effect Sensor.<br />
2. ISOPACK Power Diodes.<br />
3.4 Detail <strong>of</strong> various components <strong>of</strong> Electronic Regulator<br />
(i) TERMINAL BOX :<br />
The terminal box <strong>of</strong> the ERRU is having terminals like the conventional two<br />
number DC+ and DC-. The wiring in the coach has to be modified as per the<br />
drawing No. ER25-050-RIV.2 for 25 kW and ER4.5-W-001 for 4.5 kW, enclosed<br />
GENERAL SERVICES : TRAIN LIGHTING 31