Bar LCM Specification SL4238ML-L1
Bar LCM Specification SL4238ML-L1
Bar LCM Specification SL4238ML-L1
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>SL4238ML</strong>-<strong>L1</strong><br />
3.6. Power Sequence<br />
3.6.1. LCD Driving circuit<br />
Table 8. POWER SEQUENCE<br />
Parameter<br />
T1<br />
T2<br />
T3<br />
T4<br />
T5<br />
T6<br />
T7<br />
T8<br />
Min<br />
0.5<br />
0<br />
200<br />
200<br />
1.0<br />
-<br />
0.5<br />
100<br />
Systems Technology Inc.<br />
Value<br />
Typ<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
<strong>Bar</strong> <strong>LCM</strong> <strong>Specification</strong><br />
Document No.: 1101-4238540<strong>L1</strong> Version 0.1<br />
Max<br />
20<br />
-<br />
-<br />
-<br />
-<br />
-<br />
T2<br />
-<br />
ms<br />
ms<br />
ms<br />
ms<br />
s<br />
ms<br />
s<br />
ms<br />
Remarks<br />
Note :<br />
1. Please avoid floating state of interface signal at invalid period.<br />
2. When the power supply for LCD (VLCD) is off, be sure to pull down the valid and invalid data to 0V.<br />
3. The T3 / T4 is recommended value, the case when failed to meet a minimum specification,<br />
abnormal display would be shown. There is no reliability problem.<br />
4. If the on time of signals (Interface signal and user control signals) precedes the on time of Power (VLCD),<br />
it will be happened abnormal display. When T6 is NC status, T6 doesn’t need to be measured.<br />
5. T5 should be measured after the Module has been fully discharged between power off and on<br />
period.<br />
6. It is recommendation specification that T8 has to be 100ms as a minimum value.<br />
Unit<br />
4<br />
3<br />
3<br />
5<br />
4<br />
6<br />
Page 16 of 32