<strong>SL4238ML</strong>-<strong>L1</strong><br />
2. Absolute Maximum Ratings<br />
Systems Technology Inc.<br />
<strong>Bar</strong> <strong>LCM</strong> <strong>Specification</strong><br />
The following items are maximum values which, if exceeded, may cause faulty operation or damage to the<br />
LCD module.<br />
Table 1. Absolute maximum ratings<br />
Driver Control Voltage<br />
Storage Humidity<br />
Parameter<br />
Power Input Voltage<br />
Operating Temperature<br />
Storage Temperature<br />
Panel Front Temperature<br />
Operating Ambient Humidity<br />
-NOTE<br />
1. Ambient temperature condition (Ta = 25 ± 2 °C )<br />
2. Temperature and relative humidity range are shown in the figure below.<br />
Wet bulb temperature should be Max 39°C, and no condensation of water.<br />
3. Gravity mura can be guaranteed below 40°C condition.<br />
4. The maximum operating temperatures is based on the test condition that the surface temperature<br />
of display area is less than or equal to 68°C with LCD module alone in a temperature controlled chamber.<br />
Thermal management should be considered in final product design to prevent the surface temperature of<br />
display area from being over 68℃. The range of operating temperature may degraded in case of<br />
improper thermal management in final product<br />
-20<br />
Wet Bulb<br />
Temperature [℃]<br />
0<br />
0<br />
LCD Circuit<br />
Driver<br />
Brightness<br />
T-Con Option Selection Voltage<br />
10<br />
20<br />
30<br />
Symbol<br />
VLCD<br />
VBL<br />
EXTVBR-B<br />
V LOGIC<br />
T OP<br />
T ST<br />
T SUR<br />
H OP<br />
H ST<br />
40<br />
Document No.: 1101-4238540<strong>L1</strong> Version 0.1<br />
90%<br />
10 20 30 40 50 60 70 80<br />
Dry Bulb Temperature [℃]<br />
50<br />
60<br />
Min<br />
-0.3<br />
-0.3<br />
0.0<br />
-0.3<br />
0<br />
-20<br />
-<br />
10<br />
10<br />
Value<br />
Max<br />
+14.0<br />
+27.0<br />
+5.5<br />
+4.0<br />
+50<br />
+60<br />
+68<br />
90<br />
90<br />
60%<br />
40%<br />
10%<br />
Humidity [(%)RH]<br />
Unit<br />
VDC<br />
VDC<br />
ON / OFF VOFF / VON -0.3 +5.5 VDC<br />
1<br />
VDC<br />
VDC<br />
°C<br />
°C<br />
°C<br />
%RH<br />
%RH<br />
Storage<br />
Operation<br />
Remarks<br />
2 , 3<br />
4<br />
2 , 3<br />
Page 4 of 32