29.03.2014 Views

BiSoft1131 - Binar Elektronik

BiSoft1131 - Binar Elektronik

BiSoft1131 - Binar Elektronik

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2005-02-07<br />

PAGE 1 (3)<br />

<strong>BiSoft1131</strong><br />

UPDATES AND RELEASE NOTES<br />

ver 1.21.08 RELEASE DATE: 2005-02-07<br />

Updates<br />

• Supports more than 25 IP addresses.<br />

• Problems causing timers to hang after 24 days fixed.<br />

Software part of the release:<br />

SoftControl: ver 2.3.56c<br />

BiFas lib: ver 1.13<br />

Standard lib: ver 1.21.05<br />

Help system: ver 1.11<br />

NetEdit: ver 2.01.04<br />

ver 1.21.06 RELEASE DATE: 2004-02-10<br />

Updates<br />

• Release notes accessible from the Start menu.<br />

• The On-line mode was not accessible if the Seek dialog was open. Fixed.<br />

• The following functions now work properly:<br />

E_TIME_TO_DINT, E_DINT_TO_TIME, E_ADD, E_MAX, E_MIN, TON,<br />

E_TON, TOF, E_TOF, TP and E_TP.<br />

• String handling improved. However, be cautious not to use strings longer<br />

than 32 characters in length! If done, the variable stored in the next<br />

memory position will be overwritten.<br />

• Help System updated (now version 1.11).<br />

• NetEdit updated (now version 2.01.04).<br />

• From now on the standard library gets the same version number as the <strong>BiSoft1131</strong> release.<br />

• BiFas Library updated (now version 1.13).<br />

• The following function blocks added:<br />

MotionMultiAxes Multi axes motion control block for one to five axes.<br />

MotionSingleAxis Single axis motion with possibility to get feedback from an extern encoder.<br />

AnalogServoInit Initiates a servo drive with an analog input –10V to +10V via BiEnc.<br />

AnalogServoPos Positions a servo drive with an analog input –10V to +10V via BiEnc.<br />

CamTableGenerat Generates a CAM table (replacement for older block “Profilegenerator”).<br />

CamTableInsParam Used for entering parameters into the parameter list “mdParamList”.<br />

CamTableInsPoint Used for entering positioning points into the point list “mdPointList”.<br />

CamTableSeek Used for finding the table positioning point closest to the actual position.<br />

CamTableMotion Reads CAM tables and sends positioning data to the servo every 5 ms.<br />

FilterFirAdj Adjustable FIR filter.<br />

RotationCheck RotationCheck<br />

BiDispSend Sends data to the industrial display BiDisp via a BRSC CAN-Serial converter.<br />

• The following function blocks are updated:<br />

BIMError<br />

BIMInit<br />

FiterFir<br />

SEWMdsPos<br />

SEWMdvPos<br />

SEWDriver<br />

OneAxisMotion<br />

SEWMdsPos<br />

SEWMdvPos<br />

SewDriver<br />

Alarmhandler<br />

Output for communication alarm added<br />

No longer blocks re-initiation<br />

Causes less system load<br />

Can now be calibrated in simulated mode also.<br />

Sensor resolution can be defined. EN and ENO pins are removed.<br />

Alarms no longer freezes the Is-position.<br />

An output is set if alarm exists.<br />

Software part of the release:<br />

SoftControl: ver 2.3.56c<br />

BiFas lib: ver 1.13<br />

Standard lib: ver 1.21.05<br />

Help system: ver 1.11<br />

NetEdit: ver 2.01.04


2005-02-07<br />

PAGE 2 (3)<br />

<strong>BiSoft1131</strong><br />

UPDATES AND RELEASE NOTES<br />

ver 1.21.04 RELEASE DATE: 2002-08-30<br />

Updates<br />

• Improved error handling in on-line mode.<br />

• Improved program download procedure.<br />

• Improved serial communication.<br />

• NetEdit updated (now version 2.0.4.4).<br />

• Editing an existing node will no longer create a new one.<br />

• Now runs on Windows2000.<br />

• Help System updated (now version 1.10).<br />

• Standard Library updated (now version 1.28).<br />

• Function blocks for the following new BRIOS2 terminals added:<br />

750-346 Fieldbus coupler DeviceNet, (Economy)<br />

750-411 2-Channel Digital input module, 24VDC, 0.2ms<br />

750-419 2-Channel Digital input module, 24VDC, 3.0ms, with diagnostics<br />

750-423 4-Channel Digital input module, 24VAC/DC, 50ms, with jumper contacts<br />

750-425 2-Channel Digital input module, NAMUR proximity switch<br />

750-430 8-Channel Digital input module, 24VDC, 3.0ms<br />

750-431 8-Channel Digital input module, 24VDC, 0.2ms<br />

750-472 2-Channel Analog input module, 0-20mA, 16-bit single-ended<br />

750-474 2-Channel Analog input module, 4-20mA, 16-bit single-ended<br />

750-476 2-Channel Analog input module, 0-10V, 16-bit single-ended<br />

750-478 2-Channel Analog input module, +-10V, 16-bit single-ended<br />

750-491 1-Channel Analog input module, Resistor bridge<br />

750-507 2-Channel Digital output module, 24VDC, 2.0A, short-circuit protected, with diagnostics<br />

750-517 2-Channel Relay output module, 230VAC, 300VDC, 1.0A, changeover contacts<br />

750-522 2-Channel Digital output module, 230VAC, with solid state relay 3A for 30 sec<br />

750-530 8-Channel Digital output module, 24VDC, 0.5A, short-circuit protected<br />

750-621 Seperation module with power jumper contacts<br />

750-637 Incremental encoder interface, with cam outputs<br />

• Boundry checks added to the following functions:<br />

TAN, ASIN, ACOS, LN LOG and SQRT<br />

TAN(-π/2 (±10 -6 )) = 0; TAN(π/2 (±10 -6 )) = 0<br />

ACOS(1) = 0<br />

ASIN(1) = π/2<br />

LN(


2005-02-07<br />

PAGE 3 (3)<br />

<strong>BiSoft1131</strong><br />

UPDATES AND RELEASE NOTES<br />

ver 1.20.26 RELEASE DATE: 2001-12-13<br />

Updates<br />

• A database repair tool has been included.<br />

• Help System updated (version 1.09).<br />

• BiFas Library version 1.11 now included.<br />

• Applicable BiFas function blocks are updated with the parameter<br />

“ParServiceId”. This makes it possible to choose whether servo<br />

parameters are written to the RAM or the EEPROM memory area of the<br />

MOVIDRIVE servo amplifier.<br />

• A new version of NetEdit is included.<br />

(directory path to NetEdit now stored in the Windows System register)<br />

• Problems associated with setting Normal Task execution interval fixed.<br />

• Roll-over problems in the TON, TOF, E_TON and E_TOF functions fixed.<br />

Software part of the release:<br />

SoftControl: ver 2.3.56c<br />

BiFas lib: ver 1.11<br />

Standard lib: ver 1.26<br />

Help system: ver 1.09<br />

NetEdit: ver 2.0.4.2<br />

ver 1.20.24 RELEASE DATE: 2001-09-21<br />

Updates<br />

• This version fixes problems which could occur in the On-line driver. Large<br />

application files now are properly downloaded and switched in.<br />

• The Senitel hardware protection device is no longer needed.<br />

• New low-level functions in the IO_Misc Library.<br />

Software part of the release:<br />

SoftControl: ver 2.3.56c<br />

BiFas lib: ver 1.10<br />

Standard lib: ver 1.24<br />

Help system: ver 1.07<br />

NetEdit: ver -