30.10.2012 Views

Photovoltaic Solar Inverter Series ES - Effekta

Photovoltaic Solar Inverter Series ES - Effekta

Photovoltaic Solar Inverter Series ES - Effekta

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Photovoltaic</strong> <strong>Solar</strong> <strong>Inverter</strong> <strong>Series</strong> <strong>ES</strong> Status diagnosis and troubleshooting<br />

LCD<br />

display<br />

Description Explanation Troubleshooting<br />

Er24 Output current<br />

sense defect<br />

Er25 BOOSTER_A<br />

over-current<br />

Er26 BOOSTER_B<br />

over-current<br />

Er29 PV inverter<br />

output DC current<br />

over spec.<br />

Error in the output current<br />

reading.<br />

The current in the DC<br />

mains is higher than expected.<br />

DC current at output of<br />

solar inverter is too high.<br />

Er06 EPO The PV solar inverter is in<br />

the emergency power off<br />

mode.<br />

Er09 PV inverter<br />

over-current<br />

Er11 PV inverter<br />

over-load<br />

Er13 PV inverter<br />

short-circuit<br />

Er14 PV inverter<br />

PLL defect<br />

Er10 PV inverter<br />

over temperature<br />

Er18 Heatsink<br />

over temperature<br />

Over-current on the AC<br />

side. The current in the AC<br />

mains is higher than expected.<br />

Over-load on the AC side.<br />

The mains load in the AC<br />

mains is higher than expected.<br />

Short circuit on the<br />

AC side.<br />

The PV solar inverter is<br />

not in phase with the<br />

mains electricity.<br />

The internal temperature<br />

is too high.<br />

The temperature on the<br />

cooling element is too<br />

high.<br />

switches off, reinsert<br />

all the connections<br />

and check it again.<br />

4. If the error still occurs,<br />

please contact your<br />

dealer.<br />

1. Detach the connection<br />

at the EPO con-<br />

nection.<br />

2. If the error still occurs,<br />

please contact your<br />

dealer.<br />

1. Turn off the AC current<br />

switch; check the<br />

peripheral AC current<br />

system configurations<br />

and the mains condi-<br />

tions.<br />

2. If the error still occurs,<br />

please contact your<br />

dealer.<br />

1. Try to reduce the<br />

surrounding tempera-<br />

<strong>ES</strong> series 49<br />

ture.<br />

2. Install the solar inverter<br />

in a cooler<br />

place.<br />

3. If the error still occurs,<br />

please contact your<br />

dealer.