No. &date 74<br />

DATE : 29 / 8 / 2011<br />

SCOPE To be used for generating smoke in fire fighters training<br />

-Technical offers should explain each item required in our form below in details<br />

(Comply, provided, refer to ….etc) comments are not acceptable at all.<br />

-Technical offers will be studied according to the answers and comments, which have to be filled in our<br />

specification form below.<br />

- Technical offer should include product catalogue.<br />

Page 1 of 3


Required Specification<br />

1 Ability to control the smoke density.<br />

Mechanism of controlling the smoke density<br />

and density range should be described.<br />

2 Ability to adjust smoke quantity.<br />

Mechanism of adjusting the smoke quantity<br />

and quantity range should be described.<br />

3 Ability to regulate evaporation ratio.<br />

4 Two heating elements, could be switch on<br />

independently.<br />

5 Warm up time: to be mentioned.<br />

6 Fluid inlet pressure : to be specified.<br />

7 Power consumption: to be specified.<br />

8 Different operating modes: to be described.<br />

9 Light weight : weight to be specified.<br />

10 Easy to handle and transport, mechanism to<br />

be specified.<br />

11 Electronic control panel and display should<br />

be described.<br />

12 Tank capacity and fluid consumption to be<br />

mentioned<br />

13 The generated smoke should be free of toxic<br />

and oil materials, and doesn’t leave any<br />

harmful residue.<br />

14 Particle size: to be mentioned.<br />

Detail<br />

Tender’s Specification<br />

Brand<br />

Name<br />

Model No.<br />

Origin<br />

Page 2 of 3


15 Fluid spare quantity:<br />

Supplying of fluid quantity to be enough to<br />

operate the smoke generator for 50 hours at<br />

maximum discharge ratio, life shelf time for<br />

fluid to be specified.<br />

General<br />

1 The unit should be approved by international<br />

standard<br />

2 Catalogs for use, maintenance and spare<br />

parts for each component should be<br />

provided.<br />

3 List of recommended spare parts should be<br />

provided.<br />

4 Training of use and maintenance on CD .<br />

5 The supplier should guarantee spare parts<br />

supplying for both the smoke generator and<br />

fluid for minimum of ten years.<br />