Psi value<br />

Psi value = U factor * length <strong>of</strong> 2D model<br />

– sum <strong>of</strong> U values * length <strong>of</strong> flanking elements<br />

Psi value = 0.3922 - 0.12x2 - 0.10x2.324 = -0.0802W/mK<br />

Assumptions built into model:<br />

• C sections have not been included<br />

• Ceiling filler has not been included<br />

<strong>Scottish</strong> <strong>Energy</strong> <strong>Systems</strong> <strong>Group</strong><br />