Determination o f h e i g h t<br />
Determination of height can easily be done by eans of the <strong>Dyna</strong> healing<br />
abutments. There is a choice in different types depending on the<br />
type of construction that has been chosen. By means of the markings<br />
the height of the definitive abutments can be determined simpler.<br />
So accurately measure the Gingiva<br />
Height (GH) after the healing period<br />
= distance between the upper side<br />
of the implant and the gingiva<br />
The standard healing abutment ø 4mm has height markings on 2 and<br />
4mm and has a total height of 6mm (82HE6).<br />
82HE6<br />
4<br />
2<br />
6 mm<br />
Imp r e s s i o n ta k i n g<br />
To guarantee an optimal impression at implant level when using<br />
open tray technique, the following options are available:<br />
Impression coping octa (without octa) incl. screw (82IC2)<br />
Impression coping octa short (without octa) incl. screw (81IC0)<br />
Impression coping octa (with octa) incl. screw (81IC2)<br />
Impression coping octa short (with octa) incl. screw (81IC1)<br />
12,25 mm<br />
9,25 mm<br />
81IS2<br />
81IS1<br />
82IC2<br />
81IC0<br />
81IC2<br />
81IC1<br />
30Ncm<br />
Torque<br />
Re m o v a b l e prosthetics<br />
For removable prosthetics different abutment systems are available.<br />
Each has its own indication area and unique characteristics.<br />
The use of a Torq wrench (30Ncm for all abutments, but 35Ncm for<br />
extension abutments) in combination with the <strong>Dyna</strong> Octalock connection<br />
prevents loosening of the abutments.<br />
Looking at hygiene aspects, the following heights above<br />
the gingiva are recommended:<br />
Magnetic abutment<br />
82MG...<br />
3, 4, 5mm<br />
84MG1<br />
~1.5mm<br />
Available in 3, 4 and 5mm height for <strong>Dyna</strong> Helix DC/ST (82MG3,<br />
82MG4, 82MG5) and 1mm height for <strong>Dyna</strong> Helix TM (84MG1).<br />
Ball abutment<br />
~0.5 - 1.0mm<br />
I.A. Bar en SFI Bar abutment<br />
Extension abutment<br />
0, 1, 2, 3, 4, 5, 6mm<br />
~0.5 - 1.0mm<br />
Two types of completely prefabricated titanium bar systems. Both<br />
systems used extension abutments of 0 till 5 mm (+6mm for IA Bar)<br />
(I.A.Bar 82IE0 till 82IE6, SFI Bar 82SF0 till 82SF5). Info about the<br />
bars can be found in the pricelist and manuals.<br />
Heights untill the bar then are respectively 1.5<br />
(H0), 2.5 (H1), 3.5 (H2), 4.5 (H3), 5.5 (H4), 6.5 (H5)<br />
and 7.5mm (H6) using an implant with a Ø4.0mm<br />
platform<br />
82IE...<br />
82SF...<br />
~0.5 - 1.0mm<br />
An extension abutment of 5mm (82EO5) has the same internal connection<br />
as an implant and is available for increasing the height of<br />
excisting abutments<br />
Besides that there is also a range of extension abutments with the<br />
name Extension level extension abutments, available in the heights<br />
2, 3, 4, 5 and 6mm (82EL2 till 82EL6). These abutments can be used<br />
on implant level and in combination with special abutments. Extension<br />
level abutments 0mm are available for magnet (82EM0), ball<br />
(82EB0C), cementable bar (89BR0), bar goldcylinder (89BG0) and<br />
bar POM cylinder (89BP0). In the bar sets a special extension level<br />
abutment screw (82ES0) is enclosed. This screw is also available in<br />
a longer version (82ES1).<br />
<strong>Dyna</strong> Helix ® DC/ST implants are, first of all, designed for two-phase<br />
surgery. Under special circumstances, when all conditions are met,<br />
these can also be used in one-phase surgery. For these situations<strong>Dyna</strong><br />
fabricated special tulip shaped healing abutments that make stitching<br />
of the mucosa under the abutment possible. These abutments<br />
are available in the heights 3.5mm, 4.5mm and 5.5mm (83HE35,<br />
83HE45, 83HE55). These healing abutments also have heightmarkings<br />
at 2 and 4 mm.<br />
5,5 mm<br />
4,5 mm<br />
3,5 mm<br />
83HE35<br />
2<br />
83HE45<br />
2<br />
83HE55<br />
The healing abutments ø 5mm for fixed constructions are available<br />
in the heights 2mm, 4mm and 6mm (81HE2, 81HE4, 81HE6). Height<br />
markings are available at 2, 3 and 4mm. The healing abutment ø<br />
6mm (81HA6) only has a marking at 3mm and is used for preparing<br />
the sulcus on using the <strong>Dyna</strong> Angled and Straight XL abutments.<br />
4<br />
2<br />
When no transfer of the internal octagon is needed, the closed<br />
tray technique can be used:<br />
Impression coping octa CIT (closed tray technique) (82EI0)<br />
Impression coping octa CIT H8 (closed tray technique) (82EI08)<br />
82EI0<br />
5 mm<br />
82EI08<br />
8 mm<br />
For a transfer of the intra oral situation to the model in the laboratory<br />
several implant analogues are available:<br />
<strong>Implant</strong> Analog octa (81IA0)<br />
<strong>Implant</strong> Analog Helix TM octa (83IA0)<br />
IA Bar <strong>Implant</strong> Analog (02IA0)<br />
Extension Level <strong>Implant</strong> Analog (82IA0)<br />
Ball Laboratory Patrix (5767C)<br />
Verkrijgbaar in 0, 1, 2, 3, 4, 5 en 6mm (82BL0C t/m 82BL6C).<br />
Bar Constructions<br />
82BL3C<br />
0, 1, 2, 3, 4, 5, 6mm<br />
~0.5 - 1.0mm<br />
Several types of abutments are availabe for fabricating a bar construction.<br />
Goldcylinder octa (82BG0)<br />
POM cylinder octa (82BP0)<br />
Titanium cylinder octa H10 (82BT10)<br />
Universal (cast to) abutment octa (no octa) (81UA0)<br />
Universal (cast to) abutment octa (with octa) (81UA1)<br />
Universal (castable) plastic abutment octa (81UP1)<br />
(Alle abutments worden in het implantaat vastgezet door middel<br />
van een universele abutment screw (81AS0)).<br />
81AS0<br />
82EM0<br />
82EO5<br />
82EB0C<br />
5mm<br />
<strong>Dyna</strong> Locator abutment<br />
89BR0<br />
82EL...<br />
82LC1<br />
82ES0<br />
89BG0<br />
82ES1<br />
2, 3, 4, 5, 6mm<br />
89BP0<br />
Available in 1.5, 3, 4, 5 and 6mm (82LC1, 82LC3 t/m 82LC6)<br />
~0.5 - 1.0mm<br />
1.5, 3, 4, 5, 6mm<br />
6 mm<br />
4 mm<br />
2 mm<br />
10 mm<br />
5 mm 12 mm<br />
<strong>Dyna</strong> Temporary abutment<br />
81HE2<br />
81HE4<br />
81HE6<br />
81HA6<br />
81IA0<br />
83IA0<br />
02IA0<br />
82IA0<br />
5767C<br />
82BG0<br />
82BP0<br />
82BT10<br />
81UA0<br />
81UA1<br />
81UP1<br />
Available without octa (81TA0) or<br />
with octa (81TA1)<br />
81TA0<br />
81TA1