Determination o f h e i g h t<br />

Determination of height can easily be done by eans of the <strong>Dyna</strong> healing<br />

abutments. There is a choice in different types depending on the<br />

type of construction that has been chosen. By means of the markings<br />

the height of the definitive abutments can be determined simpler.<br />

So accurately measure the Gingiva<br />

Height (GH) after the healing period<br />

= distance between the upper side<br />

of the implant and the gingiva<br />

The standard healing abutment ø 4mm has height markings on 2 and<br />

4mm and has a total height of 6mm (82HE6).<br />

82HE6<br />

4<br />

2<br />

6 mm<br />

Imp r e s s i o n ta k i n g<br />

To guarantee an optimal impression at implant level when using<br />

open tray technique, the following options are available:<br />

Impression coping octa (without octa) incl. screw (82IC2)<br />

Impression coping octa short (without octa) incl. screw (81IC0)<br />

Impression coping octa (with octa) incl. screw (81IC2)<br />

Impression coping octa short (with octa) incl. screw (81IC1)<br />

12,25 mm<br />

9,25 mm<br />

81IS2<br />

81IS1<br />

82IC2<br />

81IC0<br />

81IC2<br />

81IC1<br />

30Ncm<br />

Torque<br />

Re m o v a b l e prosthetics<br />

For removable prosthetics different abutment systems are available.<br />

Each has its own indication area and unique characteristics.<br />

The use of a Torq wrench (30Ncm for all abutments, but 35Ncm for<br />

extension abutments) in combination with the <strong>Dyna</strong> Octalock connection<br />

prevents loosening of the abutments.<br />

Looking at hygiene aspects, the following heights above<br />

the gingiva are recommended:<br />

Magnetic abutment<br />

82MG...<br />

3, 4, 5mm<br />

84MG1<br />

~1.5mm<br />

Available in 3, 4 and 5mm height for <strong>Dyna</strong> Helix DC/ST (82MG3,<br />

82MG4, 82MG5) and 1mm height for <strong>Dyna</strong> Helix TM (84MG1).<br />

Ball abutment<br />

~0.5 - 1.0mm<br />

I.A. Bar en SFI Bar abutment<br />

Extension abutment<br />

0, 1, 2, 3, 4, 5, 6mm<br />

~0.5 - 1.0mm<br />

Two types of completely prefabricated titanium bar systems. Both<br />

systems used extension abutments of 0 till 5 mm (+6mm for IA Bar)<br />

(I.A.Bar 82IE0 till 82IE6, SFI Bar 82SF0 till 82SF5). Info about the<br />

bars can be found in the pricelist and manuals.<br />

Heights untill the bar then are respectively 1.5<br />

(H0), 2.5 (H1), 3.5 (H2), 4.5 (H3), 5.5 (H4), 6.5 (H5)<br />

and 7.5mm (H6) using an implant with a Ø4.0mm<br />

platform<br />

82IE...<br />

82SF...<br />

~0.5 - 1.0mm<br />

An extension abutment of 5mm (82EO5) has the same internal connection<br />

as an implant and is available for increasing the height of<br />

excisting abutments<br />

Besides that there is also a range of extension abutments with the<br />

name Extension level extension abutments, available in the heights<br />

2, 3, 4, 5 and 6mm (82EL2 till 82EL6). These abutments can be used<br />

on implant level and in combination with special abutments. Extension<br />

level abutments 0mm are available for magnet (82EM0), ball<br />

(82EB0C), cementable bar (89BR0), bar goldcylinder (89BG0) and<br />

bar POM cylinder (89BP0). In the bar sets a special extension level<br />

abutment screw (82ES0) is enclosed. This screw is also available in<br />

a longer version (82ES1).<br />

<strong>Dyna</strong> Helix ® DC/ST implants are, first of all, designed for two-phase<br />

surgery. Under special circumstances, when all conditions are met,<br />

these can also be used in one-phase surgery. For these situations<strong>Dyna</strong><br />

fabricated special tulip shaped healing abutments that make stitching<br />

of the mucosa under the abutment possible. These abutments<br />

are available in the heights 3.5mm, 4.5mm and 5.5mm (83HE35,<br />

83HE45, 83HE55). These healing abutments also have heightmarkings<br />

at 2 and 4 mm.<br />

5,5 mm<br />

4,5 mm<br />

3,5 mm<br />

83HE35<br />

2<br />

83HE45<br />

2<br />

83HE55<br />

The healing abutments ø 5mm for fixed constructions are available<br />

in the heights 2mm, 4mm and 6mm (81HE2, 81HE4, 81HE6). Height<br />

markings are available at 2, 3 and 4mm. The healing abutment ø<br />

6mm (81HA6) only has a marking at 3mm and is used for preparing<br />

the sulcus on using the <strong>Dyna</strong> Angled and Straight XL abutments.<br />

4<br />

2<br />

When no transfer of the internal octagon is needed, the closed<br />

tray technique can be used:<br />

Impression coping octa CIT (closed tray technique) (82EI0)<br />

Impression coping octa CIT H8 (closed tray technique) (82EI08)<br />

82EI0<br />

5 mm<br />

82EI08<br />

8 mm<br />

For a transfer of the intra oral situation to the model in the laboratory<br />

several implant analogues are available:<br />

<strong>Implant</strong> Analog octa (81IA0)<br />

<strong>Implant</strong> Analog Helix TM octa (83IA0)<br />

IA Bar <strong>Implant</strong> Analog (02IA0)<br />

Extension Level <strong>Implant</strong> Analog (82IA0)<br />

Ball Laboratory Patrix (5767C)<br />

Verkrijgbaar in 0, 1, 2, 3, 4, 5 en 6mm (82BL0C t/m 82BL6C).<br />

Bar Constructions<br />

82BL3C<br />

0, 1, 2, 3, 4, 5, 6mm<br />

~0.5 - 1.0mm<br />

Several types of abutments are availabe for fabricating a bar construction.<br />

Goldcylinder octa (82BG0)<br />

POM cylinder octa (82BP0)<br />

Titanium cylinder octa H10 (82BT10)<br />

Universal (cast to) abutment octa (no octa) (81UA0)<br />

Universal (cast to) abutment octa (with octa) (81UA1)<br />

Universal (castable) plastic abutment octa (81UP1)<br />

(Alle abutments worden in het implantaat vastgezet door middel<br />

van een universele abutment screw (81AS0)).<br />

81AS0<br />

82EM0<br />

82EO5<br />

82EB0C<br />

5mm<br />

<strong>Dyna</strong> Locator abutment<br />

89BR0<br />

82EL...<br />

82LC1<br />

82ES0<br />

89BG0<br />

82ES1<br />

2, 3, 4, 5, 6mm<br />

89BP0<br />

Available in 1.5, 3, 4, 5 and 6mm (82LC1, 82LC3 t/m 82LC6)<br />

~0.5 - 1.0mm<br />

1.5, 3, 4, 5, 6mm<br />

6 mm<br />

4 mm<br />

2 mm<br />

10 mm<br />

5 mm 12 mm<br />

<strong>Dyna</strong> Temporary abutment<br />

81HE2<br />

81HE4<br />

81HE6<br />

81HA6<br />

81IA0<br />

83IA0<br />

02IA0<br />

82IA0<br />

5767C<br />

82BG0<br />

82BP0<br />

82BT10<br />

81UA0<br />

81UA1<br />

81UP1<br />

Available without octa (81TA0) or<br />

with octa (81TA1)<br />

81TA0<br />

81TA1