<strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong> <strong>Assignments</strong><br />
<strong><strong>Po</strong><strong>rt</strong></strong>s You Can Use in Cha<strong>rt</strong> Logic<br />
When writing your own cha<strong>rt</strong> logic in PAC Control, you can use the following<br />
po<strong>rt</strong> numbers:<br />
<strong><strong>Po</strong><strong>rt</strong></strong><br />
<strong><strong>Po</strong><strong>rt</strong></strong>s You Cannot Use in Cha<strong>rt</strong> Logic<br />
Description<br />
<strong>22</strong>004 <strong>and</strong> <strong>22</strong>005 Reserved for use in PAC Control user cha<strong>rt</strong> logic<br />
49152 – 49999<br />
51000 – 65535<br />
The following table provides a summary of the po<strong>rt</strong> numbers you should not<br />
use in PAC Control cha<strong>rt</strong> logic:<br />
<strong><strong>Po</strong><strong>rt</strong></strong><br />
Available for use in PAC Control user cha<strong>rt</strong> logic<br />
Description<br />
0 – <strong>22</strong>003 Reserved by the Internet Assigned Number Authority (IANA) for<br />
<strong>22</strong>006 – purposes other than PAC Control user cha<strong>rt</strong> logic. For more information,<br />
see the tables 49151<br />
below.<br />
50000 –<br />
50999<br />
Reserved by <strong>Opto</strong> <strong>22</strong> to be used internally by PAC <strong>and</strong> Ultimate<br />
controllers. For more information, see “<strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong> Numbers<br />
Assigned by the IANA” on page 2.<br />
<strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong> <strong>Assignments</strong><br />
<strong>Opto</strong> <strong>22</strong> Reserved <strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong>s<br />
The following po<strong>rt</strong> numbers are reserved for use by <strong>Opto</strong> <strong>22</strong> firmware:<br />
<strong><strong>Po</strong><strong>rt</strong></strong><br />
Description<br />
2001 PAC MMP host po<strong>rt</strong> or <strong>Opto</strong>Control host po<strong>rt</strong><br />
2002 <strong>Opto</strong>Control peer po<strong>rt</strong><br />
2003 <strong>Opto</strong>Control peer po<strong>rt</strong><br />
<strong>22</strong>000 Reserved for future use<br />
<strong>22</strong>001 PAC Control <strong>and</strong> ioControl host po<strong>rt</strong><br />
<strong>22</strong>002 PAC Control background download feature<br />
<strong>22</strong>003 Reserved for future use<br />
<strong>22</strong>500 –<br />
<strong>22</strong>531<br />
50000 –<br />
50999<br />
Used for <strong>Opto</strong> <strong>22</strong> serial communication modules (SCM)<br />
Used internally by PAC <strong>and</strong> Ultimate controllers<br />
Form 1940-101105<br />
TECHNICAL NOTE<br />
PAGE<br />
1
<strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong> <strong>Assignments</strong><br />
<strong><strong>Po</strong><strong>rt</strong></strong>s Used by <strong>Opto</strong> <strong>22</strong> PAC Controllers <strong>and</strong> Brains<br />
The following po<strong>rt</strong> numbers are reserved for use by PAC controllers <strong>and</strong> brains:<br />
<strong><strong>Po</strong><strong>rt</strong></strong><br />
Description<br />
20 FTP<br />
21 FTP<br />
25 SMTP<br />
67 BootP server<br />
68 BootP client<br />
161 SNMP<br />
162 SNMP traps<br />
502 Modbus/<strong><strong>TC</strong>P</strong><br />
<strong>22</strong><strong>22</strong> EtherNet/IP (<strong>UDP</strong> for I/O)<br />
23567 PAC Controller redundancy feature<br />
44818 EtherNet/IP (<strong><strong>TC</strong>P</strong> & <strong>UDP</strong> explicit messages)<br />
<strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong> Numbers Assigned by the IANA<br />
The table below provides some information about the <strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> po<strong>rt</strong> numbers<br />
assigned by the Internet Assigned Number Authority (IANA).<br />
For a complete listing of po<strong>rt</strong> numbers assigned by the IANA, go to<br />
www.iana.org/assignments/po<strong>rt</strong>-numbers. See also www.iana.org for more<br />
information about the IANA.<br />
There are three categories of <strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> po<strong>rt</strong> numbers assigned by IANA, as<br />
follows:<br />
• Well Known: Known to be unique <strong>and</strong> have only one use each. These are<br />
essentially the same as registered po<strong>rt</strong> numbers.<br />
• Registered: Assigned by the IANA for a specific use by a company (such as<br />
<strong>Opto</strong> <strong>22</strong>).<br />
• Dynamic: Not assigned or well-known for a pa<strong>rt</strong>icular use, <strong>and</strong> thus available<br />
for use in PAC Control cha<strong>rt</strong> logic. If you are doing Ethernet communication,<br />
but not using one of the well-known or reserved purposes or protocols, then<br />
you would use one of these po<strong>rt</strong> numbers.<br />
PAGE<br />
2 TECHNICAL NOTE • Form 1940-101105
<strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong> <strong>Assignments</strong><br />
Category <strong><strong>Po</strong><strong>rt</strong></strong> Description<br />
Well Known 0 – 1023<br />
Registered 1024 – 49151<br />
49152 – 49999<br />
You should not use any of these po<strong>rt</strong> numbers for purposes<br />
such as cha<strong>rt</strong> logic.<br />
With the exception of <strong>22</strong>004 <strong>and</strong> <strong>22</strong>005, which are<br />
reserved for <strong>Opto</strong> <strong>22</strong> customers, you should not use<br />
any of these po<strong>rt</strong> numbers.<br />
You can use these dynamic po<strong>rt</strong> numbers because<br />
they are not used by <strong>Opto</strong> <strong>22</strong> products.<br />
Dynamic<br />
50000 - 50999<br />
51000 – 65535<br />
<strong>Opto</strong> <strong>22</strong> PAC controllers use these po<strong>rt</strong> numbers for<br />
internal purposes. You should not use the po<strong>rt</strong> numbers<br />
in this range.<br />
You can use these dynamic po<strong>rt</strong> numbers because<br />
they are not used by <strong>Opto</strong> <strong>22</strong> products.<br />
TECHNICAL NOTE • Form 1940-101105<br />
PAGE<br />
3
<strong><strong>TC</strong>P</strong> <strong>and</strong> <strong>UDP</strong> <strong><strong>Po</strong><strong>rt</strong></strong> <strong>Assignments</strong><br />
PAGE<br />
4<br />