Advanced Hemodynamics - Orlando Health
Advanced Hemodynamics - Orlando Health
Advanced Hemodynamics - Orlando Health
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Advanced</strong> Hemodynamic Monitoring<br />
Heart Rate<br />
Cardiac Output<br />
Varies by patient<br />
4 - 6 L/min<br />
Right Ventricular EF 0.40 - 0.60<br />
Calculated Hemodynamic Variables<br />
Mean Arterial Pressure<br />
Mean Pulmonary Art. Pressure<br />
Cardiac Index<br />
Stroke Volume (Index)<br />
Systemic Vasc. Resistance Index<br />
Pulmonary Vasc. Resistance Index<br />
Left Ventric. Stroke Work Index<br />
Right Ventric. Stroke Work Index<br />
Right Ventric. End.Diast.Vol.Index<br />
Body Surface Area (BSA)<br />
70 - 105 mmHg<br />
9 - 16 mmHg<br />
2.8 - 4.2L/min/m2<br />
Varies (30 - 65 ml/beat/m2)<br />
1600 - 2400 dyne.sec.cm-5<br />
250 - 340 dyne.sec.cm-5<br />
43 - 62 gm.m/m2<br />
7 - 12 gm.m/m2<br />
60 - 100 mL/m2<br />
Varies by patient (m2)<br />
“Optimal” RVEDVI<br />
RVEF Normal Critically Ill<br />
.20 200 mL/m 2 240 mL/m 2<br />
.30 150 mL/m 2 180 mL/m 2<br />
.35 125 mL/m 2 150 mL/m 2<br />
.40 100 mL/m 2 120 mL/m 2<br />
.50 50 mL/m 2 60 mL/m 2<br />
Copyright 2010 <strong>Orlando</strong> <strong>Health</strong>, Education & Development 48