<strong>T2</strong> Intramedullary Nailing System Features<br />

Integrated, economical instrument platform<br />

compatible across <strong>T2</strong>, S2, and Gamma3 Nails,<br />

as well as future <strong>Stryker</strong> IM Nailing Systems<br />

Number coding on trays indicates the step during the<br />

procedure in which the instrument is used<br />

All <strong>T2</strong> implants are made of type II anodized titanium<br />

alloy (Ti6Al4V) for enhanced biomechanical and<br />

biomedical performance*<br />

Antegrade and Retrograde insertion with the same<br />

implant and the same instrumentation for Femur and<br />

Humerus<br />

<strong>T2</strong><br />

<strong>Product</strong> <strong>Portfolio</strong><br />

Intramedullary Nailing System<br />

Reamed or Unreamed nail insertion over a guide wire<br />

Non-slotted nails with closed section design and<br />

fluted profile<br />

Cannulated nails for easy passage of the fracture site<br />

No guide wire exchange needed for all Ø9−15mm<br />

femoral and tibial nails<br />

Extreme proximal and distal hole positions for<br />

extended indications<br />

Four locking modes: Static, Dynamic, Apposition /<br />

Compression and Advanced Locking<br />

Unique screw design with improved fatigue strength,<br />

insertion characteristics and holding strength **<br />

Single screw diameter for standard femoral and tibial<br />

applications (9-15mm)<br />

Cannulated condyle screws with polyaxial washers<br />

provide good anatomical fit and secure mediolateral<br />

interfragmentary compression<br />

Multiple height end caps enable intraoperative length<br />

adjustments<br />

* White Paper (B1000033) available on request<br />

** Test reports (081000MG1, 071200CG1) on file at <strong>Stryker</strong><br />

This document is intended solely for the use of healthcare professionals. A surgeon must always<br />

rely on his or her own professional clinical judgment when deciding whether to use a particular<br />

product when treating a particular patient. <strong>Stryker</strong> does not dispense medical advice and recommends<br />

that surgeons be trained in the use of any particular product before using it in surgery. The<br />

information presented in this brochure is intended to demonstrate a <strong>Stryker</strong> product. Always refer to<br />

the package insert, product label and/or user instructions including the instructions for Cleaning and<br />

Sterilization (if applicable) before using any <strong>Stryker</strong> products. <strong>Product</strong>s may not be available in all<br />

markets. <strong>Product</strong> availability is subject to the regulatory or medical practices that govern individual<br />

markets. Please contact your <strong>Stryker</strong> representative if you have questions about the availability of<br />

<strong>Stryker</strong> products in your area.<br />

<strong>Stryker</strong> Corporation or its divisions or other corporate affiliated entities own, use or have applied for<br />

the following trademarks or service marks: <strong>Stryker</strong>, <strong>T2</strong>, S2, Gamma3.<br />

All other trademarks are trademarks of their respective owners or holders.<br />

The products listed above are CE marked.<br />

Literature Number: B1000008<br />

LOT G3609<br />

Copyright © 2009 <strong>Stryker</strong><br />

<strong>Stryker</strong> Trauma GmbH<br />

Prof.-Küntscher-Strasse 1-5<br />

D-24232 Schönkirchen - Germany<br />

www.osteosynthesis.stryker.com


Multiple Locking Modes 2 Screw Diameters<br />

Dedicated Targeting Devices Technical Details Dedicated nail designs for specific indications<br />

<strong>T2</strong> Humerus <strong>T2</strong> Femur <strong>T2</strong> Tibia <strong>T2</strong> Ankle<br />

Threads & Nylon Bushings<br />

Short Long Antegrade Retrograde<br />

Proximal Humeral Nail<br />

Diameter<br />

Length<br />

Cannulation<br />

Compression<br />

Bend<br />

Locking Screws<br />

10mm driving end,<br />

8mm shaft<br />

150mm (short)<br />

220mm−300mm (long)<br />

yes<br />

-/-<br />

6° (proximal)<br />

Ø 5mm (proximal)<br />

Ø 4mm (distal)<br />

<strong>T2</strong> PHN<br />

Humeral Nail<br />

Diameter<br />

Length<br />

Cannulation<br />

Compression<br />

Bend<br />

Locking Screws<br />

7mm−9mm<br />

140mm−320mm<br />

yes<br />

6mm<br />

6° (proximal)<br />

4° (distal)<br />

Ø 4mm<br />

<strong>T2</strong> HUMERUS<br />

4mm & 5mm Titanium Locking Screws<br />

Oblique Locking Transverse Locking CCD 125° 70° Oblique Locking Three Plane Fixation Compression Condyle Screws<br />

Knee<br />

Arthrodesis<br />

Recon<br />

Diameter<br />

Length<br />

Cannulation<br />

CCD Angle<br />

Oblique Locking<br />

Compression<br />

Bend<br />

Radius<br />

Locking Screws<br />

Lag Screws<br />

Recon Nail<br />

<strong>T2</strong> RECON<br />

Antegrade<br />

9mm−15mm (distal)<br />

340mm−480mm<br />

yes<br />

125°+10° Anteversion<br />

70°+7° Retroversion<br />

-/-<br />

4° (proximal)<br />

2.0m/1.5m<br />

Ø 5mm<br />

Ø 6.5mm<br />

Short<br />

<strong>T2</strong> SCN<br />

Long<br />

Supra Condylar Nail<br />

Diameter<br />

Length (short)<br />

Length (long)<br />

Cannulation<br />

Compression<br />

Radius<br />

Locking Screws<br />

Condyle Screws<br />

9mm−14mm<br />

170mm & 200mm<br />

240mm−440mm<br />

yes<br />

-/-<br />

2.0m<br />

Ø 5mm<br />

Ø 5mm<br />

Antegrade<br />

Diameter<br />

Length<br />

Cannulation<br />

Compression<br />

Radius<br />

Locking Screws<br />

Condyle Screws<br />

Common <strong>T2</strong> Instrumentation Platform<br />

Retrograde<br />

Femoral Nail<br />

8mm−15mm<br />

140mm−480mm<br />

yes<br />

10mm<br />

3m/1.5m<br />

Ø 5mm<br />

Ø 4mm for 8mm<br />

Nail (distal)<br />

Ø 5mm<br />

Arthrodesis Nail<br />

Diameter<br />

Length<br />

Cannulation<br />

Compression<br />

Radius<br />

Bend<br />

Locking Screws<br />

<strong>T2</strong> FEMUR<br />

11.5mm & 13mm<br />

540mm−780mm<br />

yes<br />

10mm<br />

3.0m<br />

Knee Valgus<br />

Ø 5mm<br />

Standard Nail<br />

Tibial Nail<br />

Diameter<br />

Length<br />

Cannulation<br />

Compression<br />

Bend<br />

Locking Screws<br />

Distal Nail<br />

8mm−15mm<br />

240mm−420mm<br />

yes<br />

7mm<br />

10° (proximal)<br />

4° (distal)<br />

Ø 5mm<br />

Ø 4mm for 8mm Nail<br />

(distal)<br />

<strong>T2</strong> TIBIA<br />

Ankle Arthrodesis<br />

Ankle Arthrodesis Nail<br />

Diameter<br />

Length<br />

Cannulation<br />

Compression<br />

Bend<br />

Locking Screws<br />

<strong>T2</strong> AAN<br />

10mm−12mm<br />

150, 200 &<br />

300mm<br />

yes<br />

5mm<br />

5° (distal valgus)<br />

Ø 5mm<br />

Dedicated Targeting Devices Technical Details Dedicated nail designs for specific indications Multiple Locking Modes 2 Screw Diameters