<strong>T2</strong> Intramedullary Nailing System Features<br />
Integrated, economical instrument platform<br />
compatible across <strong>T2</strong>, S2, and Gamma3 Nails,<br />
as well as future <strong>Stryker</strong> IM Nailing Systems<br />
Number coding on trays indicates the step during the<br />
procedure in which the instrument is used<br />
All <strong>T2</strong> implants are made of type II anodized titanium<br />
alloy (Ti6Al4V) for enhanced biomechanical and<br />
biomedical performance*<br />
Antegrade and Retrograde insertion with the same<br />
implant and the same instrumentation for Femur and<br />
Humerus<br />
<strong>T2</strong><br />
<strong>Product</strong> <strong>Portfolio</strong><br />
Intramedullary Nailing System<br />
Reamed or Unreamed nail insertion over a guide wire<br />
Non-slotted nails with closed section design and<br />
fluted profile<br />
Cannulated nails for easy passage of the fracture site<br />
No guide wire exchange needed for all Ø9−15mm<br />
femoral and tibial nails<br />
Extreme proximal and distal hole positions for<br />
extended indications<br />
Four locking modes: Static, Dynamic, Apposition /<br />
Compression and Advanced Locking<br />
Unique screw design with improved fatigue strength,<br />
insertion characteristics and holding strength **<br />
Single screw diameter for standard femoral and tibial<br />
applications (9-15mm)<br />
Cannulated condyle screws with polyaxial washers<br />
provide good anatomical fit and secure mediolateral<br />
interfragmentary compression<br />
Multiple height end caps enable intraoperative length<br />
adjustments<br />
* White Paper (B1000033) available on request<br />
** Test reports (081000MG1, 071200CG1) on file at <strong>Stryker</strong><br />
This document is intended solely for the use of healthcare professionals. A surgeon must always<br />
rely on his or her own professional clinical judgment when deciding whether to use a particular<br />
product when treating a particular patient. <strong>Stryker</strong> does not dispense medical advice and recommends<br />
that surgeons be trained in the use of any particular product before using it in surgery. The<br />
information presented in this brochure is intended to demonstrate a <strong>Stryker</strong> product. Always refer to<br />
the package insert, product label and/or user instructions including the instructions for Cleaning and<br />
Sterilization (if applicable) before using any <strong>Stryker</strong> products. <strong>Product</strong>s may not be available in all<br />
markets. <strong>Product</strong> availability is subject to the regulatory or medical practices that govern individual<br />
markets. Please contact your <strong>Stryker</strong> representative if you have questions about the availability of<br />
<strong>Stryker</strong> products in your area.<br />
<strong>Stryker</strong> Corporation or its divisions or other corporate affiliated entities own, use or have applied for<br />
the following trademarks or service marks: <strong>Stryker</strong>, <strong>T2</strong>, S2, Gamma3.<br />
All other trademarks are trademarks of their respective owners or holders.<br />
The products listed above are CE marked.<br />
Literature Number: B1000008<br />
LOT G3609<br />
Copyright © 2009 <strong>Stryker</strong><br />
<strong>Stryker</strong> Trauma GmbH<br />
Prof.-Küntscher-Strasse 1-5<br />
D-24232 Schönkirchen - Germany<br />
www.osteosynthesis.stryker.com
Multiple Locking Modes 2 Screw Diameters<br />
Dedicated Targeting Devices Technical Details Dedicated nail designs for specific indications<br />
<strong>T2</strong> Humerus <strong>T2</strong> Femur <strong>T2</strong> Tibia <strong>T2</strong> Ankle<br />
Threads & Nylon Bushings<br />
Short Long Antegrade Retrograde<br />
Proximal Humeral Nail<br />
Diameter<br />
Length<br />
Cannulation<br />
Compression<br />
Bend<br />
Locking Screws<br />
10mm driving end,<br />
8mm shaft<br />
150mm (short)<br />
220mm−300mm (long)<br />
yes<br />
-/-<br />
6° (proximal)<br />
Ø 5mm (proximal)<br />
Ø 4mm (distal)<br />
<strong>T2</strong> PHN<br />
Humeral Nail<br />
Diameter<br />
Length<br />
Cannulation<br />
Compression<br />
Bend<br />
Locking Screws<br />
7mm−9mm<br />
140mm−320mm<br />
yes<br />
6mm<br />
6° (proximal)<br />
4° (distal)<br />
Ø 4mm<br />
<strong>T2</strong> HUMERUS<br />
4mm & 5mm Titanium Locking Screws<br />
Oblique Locking Transverse Locking CCD 125° 70° Oblique Locking Three Plane Fixation Compression Condyle Screws<br />
Knee<br />
Arthrodesis<br />
Recon<br />
Diameter<br />
Length<br />
Cannulation<br />
CCD Angle<br />
Oblique Locking<br />
Compression<br />
Bend<br />
Radius<br />
Locking Screws<br />
Lag Screws<br />
Recon Nail<br />
<strong>T2</strong> RECON<br />
Antegrade<br />
9mm−15mm (distal)<br />
340mm−480mm<br />
yes<br />
125°+10° Anteversion<br />
70°+7° Retroversion<br />
-/-<br />
4° (proximal)<br />
2.0m/1.5m<br />
Ø 5mm<br />
Ø 6.5mm<br />
Short<br />
<strong>T2</strong> SCN<br />
Long<br />
Supra Condylar Nail<br />
Diameter<br />
Length (short)<br />
Length (long)<br />
Cannulation<br />
Compression<br />
Radius<br />
Locking Screws<br />
Condyle Screws<br />
9mm−14mm<br />
170mm & 200mm<br />
240mm−440mm<br />
yes<br />
-/-<br />
2.0m<br />
Ø 5mm<br />
Ø 5mm<br />
Antegrade<br />
Diameter<br />
Length<br />
Cannulation<br />
Compression<br />
Radius<br />
Locking Screws<br />
Condyle Screws<br />
Common <strong>T2</strong> Instrumentation Platform<br />
Retrograde<br />
Femoral Nail<br />
8mm−15mm<br />
140mm−480mm<br />
yes<br />
10mm<br />
3m/1.5m<br />
Ø 5mm<br />
Ø 4mm for 8mm<br />
Nail (distal)<br />
Ø 5mm<br />
Arthrodesis Nail<br />
Diameter<br />
Length<br />
Cannulation<br />
Compression<br />
Radius<br />
Bend<br />
Locking Screws<br />
<strong>T2</strong> FEMUR<br />
11.5mm & 13mm<br />
540mm−780mm<br />
yes<br />
10mm<br />
3.0m<br />
Knee Valgus<br />
Ø 5mm<br />
Standard Nail<br />
Tibial Nail<br />
Diameter<br />
Length<br />
Cannulation<br />
Compression<br />
Bend<br />
Locking Screws<br />
Distal Nail<br />
8mm−15mm<br />
240mm−420mm<br />
yes<br />
7mm<br />
10° (proximal)<br />
4° (distal)<br />
Ø 5mm<br />
Ø 4mm for 8mm Nail<br />
(distal)<br />
<strong>T2</strong> TIBIA<br />
Ankle Arthrodesis<br />
Ankle Arthrodesis Nail<br />
Diameter<br />
Length<br />
Cannulation<br />
Compression<br />
Bend<br />
Locking Screws<br />
<strong>T2</strong> AAN<br />
10mm−12mm<br />
150, 200 &<br />
300mm<br />
yes<br />
5mm<br />
5° (distal valgus)<br />
Ø 5mm<br />
Dedicated Targeting Devices Technical Details Dedicated nail designs for specific indications Multiple Locking Modes 2 Screw Diameters