SIGUARD laser scanner LS4<br />
Technical data<br />
Protective field data<br />
Personnel protective field<br />
Detection range<br />
0–4 m (no dead zones when correctly mounted)<br />
Reflection capacity<br />
Min. 1.8 % (matt black)<br />
Measuring error Max. 83 mm (for a protective field radius < 3.5 m)<br />
Max. 100 mm (for a protective field radius > 3.5 m)<br />
Object size<br />
70 mm (cylindrical test body)<br />
Response time<br />
Min. 80 ms (by version with semi-conductor output)<br />
Number of protective fields 4 (can be changed-over using switching inputs)<br />
Output<br />
Two fail-safe PNP transistor outputs 24 V/250 mA or a safety-related bus coupling<br />
Category Category 3 acc. to EN 954-1, type 3 acc. to DIN EN IEC 61496-1, IEC 61496-3<br />
Requirement Class 4 acc. to DIN V 19250, single-fault proof<br />
Starting<br />
The start test routine and the start inhibit can be separately parameterized<br />
Warning field<br />
Detection range<br />
0–15 m<br />
Reflection capacity Min. 20 %<br />
Object size<br />
150 x 150 mm<br />
Response time<br />
Min. 80 ms (by version with semi-conductor output)<br />
Number of protective fields 4 (can be changed-over using switching inputs)<br />
Output<br />
PNP transistor output, max. 100 mA or bus coupling<br />
Contour measurement<br />
Detection range<br />
0–50 m<br />
Reflection level Min. 20 %<br />
Object size - - -<br />
Output<br />
Serial RS 232, RS 422 interface<br />
Resolution, radial<br />
5 mm<br />
Resolution, lateral 0.36°<br />
Optical properties<br />
Angular range 190°<br />
Angular resolution 0.36°<br />
Scan rate<br />
25 scans/s or 40 ms/scan<br />
Laser protection class<br />
Class 1 (safe for the eyes), DIN EN 60825-1, wavelength = 905 nm,<br />
beam divergence = 2 mrad, timebase = 100 s<br />
General data<br />
Electrical supply<br />
Standard AS-Interface PROFIBUS<br />
10<br />
Power supply<br />
+24 V DC +20 %/–30 %, power supply according to IEC 742 using a safety transformer or<br />
comparable for DC/DC converters<br />
Overcurrent protection<br />
Using a 1.25 A medium-slow-acting fuse in the electrical cabinet<br />
Current drain Approx. 300 mA Approx. 350 mA Approx. 350 mA<br />
(use a 2.5 A power supply)<br />
Power drain Approx. 8 W at 24 V Approx. 9 W at 24 V Approx. 9 W at 24 V<br />
plus the output load<br />
Overvoltage protection Overvoltage protection with safe end cut-off according to DIN EN 61496-1<br />
Voltage dips In compliance with DIN EN 61496-1<br />
Protective conductor A protective conductor may not be connected up The PROFIBUS cable<br />
shield must be<br />
connected to the<br />
protective conductor