SIGUARD laser scanner LS4<br />

Technical data<br />

Protective field data<br />

Personnel protective field<br />

Detection range<br />

0–4 m (no dead zones when correctly mounted)<br />

Reflection capacity<br />

Min. 1.8 % (matt black)<br />

Measuring error Max. 83 mm (for a protective field radius < 3.5 m)<br />

Max. 100 mm (for a protective field radius > 3.5 m)<br />

Object size<br />

70 mm (cylindrical test body)<br />

Response time<br />

Min. 80 ms (by version with semi-conductor output)<br />

Number of protective fields 4 (can be changed-over using switching inputs)<br />

Output<br />

Two fail-safe PNP transistor outputs 24 V/250 mA or a safety-related bus coupling<br />

Category Category 3 acc. to EN 954-1, type 3 acc. to DIN EN IEC 61496-1, IEC 61496-3<br />

Requirement Class 4 acc. to DIN V 19250, single-fault proof<br />

Starting<br />

The start test routine and the start inhibit can be separately parameterized<br />

Warning field<br />

Detection range<br />

0–15 m<br />

Reflection capacity Min. 20 %<br />

Object size<br />

150 x 150 mm<br />

Response time<br />

Min. 80 ms (by version with semi-conductor output)<br />

Number of protective fields 4 (can be changed-over using switching inputs)<br />

Output<br />

PNP transistor output, max. 100 mA or bus coupling<br />

Contour measurement<br />

Detection range<br />

0–50 m<br />

Reflection level Min. 20 %<br />

Object size - - -<br />

Output<br />

Serial RS 232, RS 422 interface<br />

Resolution, radial<br />

5 mm<br />

Resolution, lateral 0.36°<br />

Optical properties<br />

Angular range 190°<br />

Angular resolution 0.36°<br />

Scan rate<br />

25 scans/s or 40 ms/scan<br />

Laser protection class<br />

Class 1 (safe for the eyes), DIN EN 60825-1, wavelength = 905 nm,<br />

beam divergence = 2 mrad, timebase = 100 s<br />

General data<br />

Electrical supply<br />

Standard AS-Interface PROFIBUS<br />

10<br />

Power supply<br />

+24 V DC +20 %/–30 %, power supply according to IEC 742 using a safety transformer or<br />

comparable for DC/DC converters<br />

Overcurrent protection<br />

Using a 1.25 A medium-slow-acting fuse in the electrical cabinet<br />

Current drain Approx. 300 mA Approx. 350 mA Approx. 350 mA<br />

(use a 2.5 A power supply)<br />

Power drain Approx. 8 W at 24 V Approx. 9 W at 24 V Approx. 9 W at 24 V<br />

plus the output load<br />

Overvoltage protection Overvoltage protection with safe end cut-off according to DIN EN 61496-1<br />

Voltage dips In compliance with DIN EN 61496-1<br />

Protective conductor A protective conductor may not be connected up The PROFIBUS cable<br />

shield must be<br />

connected to the<br />

protective conductor