Whether mounted on stationary<br />
machines or on mobile systems such as<br />
driverless transport vehicles – using<br />
SIGUARD laser scanners, you can<br />
perfectly secure your hazardous areas in<br />
almost every working environment up<br />
to Category 3 according to EN 954-1.<br />
Up to four protective and warning field<br />
pairs for persons and objects can be<br />
freely set in operation. They can be<br />
simply programmed using either a PC or<br />
a laptop which means that they can be<br />
quickly and flexibly adapted to new<br />
requirements.<br />
SIGUARD laser scanners are optical<br />
distance sensors which detect any<br />
motion in a 190° working zone. By<br />
transmitting safe laser pulses and then<br />
evaluating every reflected pulse, they<br />
have everything safely in view. And<br />
when potentially hazardous situations<br />
do arise, they respond quickly and<br />
reliably.<br />
In addition to a conventional<br />
connection, the new communicationcapable<br />
versions of our SIGUARD laser<br />
scanners can be connected reliably and<br />
in a user-friendly fashion to AS-Interface<br />
Safety at Work and PROFIBUS with the<br />
PROFIsafe profile through integrated<br />
interfaces. Unified, integrated<br />
communications via standard fieldbuses<br />
can be implemented in a fail-safe<br />
fashion by transmitting safety-related<br />
and standard data together. This means<br />
that also with our SIGUARD laser<br />
scanners, you can enjoy the benefits of<br />
having just one bus coupling.<br />
SIGUARD laser scanners LS4 – the<br />
advantages at a glance:<br />
• Hazardous areas can be contactlessly<br />
and reliably secured with devices<br />
which can be universally used: on<br />
machines, production robots, conveyor<br />
systems, vehicles etc.<br />
• Standard versions with fail-safe semiconductor<br />
outputs<br />
• Safe direct connection to<br />
AS-Interface Safety at Work<br />
• User-friendly version with PROFIBUS<br />
PROFIsafe connection<br />
• When scanners are replaced, parameters<br />
are automatically transferred via<br />
PROFIBUS<br />
• Category 3 according to EN 954-1<br />
• Up to 4 personnel protective and<br />
warning field pairs which can be<br />
freely set<br />
• Protective field with max. 4 m radius<br />
for personnel safety<br />
• Extremely compact design<br />
• Low current drain (approx. 300 mA)<br />
LS4 laser scanner “Standard“<br />