DATA SHEET<br />

<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

General Description<br />

The <strong>CP64S</strong> <strong>is</strong> a versatile commercial preamplifier designed for<br />

use <strong>in</strong> restaurants, bars, health clubs and offices. The <strong>CP64S</strong> <strong>is</strong><br />

capable of serv<strong>in</strong>g two <strong>in</strong>dependent Zones. Two gated Pag<strong>in</strong>g<br />

<strong>in</strong>puts and four Program <strong>in</strong>puts are provided. Ports are provided<br />

for expansion of Page, Program or Zone signals. Four levels of<br />

priority are supported:<br />

• Priority Page<br />

• Non-Priority Page<br />

• Priority Program<br />

• Non-Priority Program<br />

The versatility of <strong>the</strong> <strong>CP64S</strong> allows a wide variety of system<br />

configurations while provid<strong>in</strong>g simple and <strong>in</strong>tuitive controls.<br />

Two gated Pag<strong>in</strong>g Inputs capable of receiv<strong>in</strong>g mic or l<strong>in</strong>e<br />

level <strong>in</strong>put are provided. Each features <strong>in</strong>dependent Mic/L<strong>in</strong>e<br />

Pad, Ga<strong>in</strong> Trim, detector Threshold, Zone Assign and Zone<br />

Level controls. Internally selectable phantom power <strong>is</strong> provided<br />

for each <strong>in</strong>put. Each Pag<strong>in</strong>g <strong>in</strong>put may be summed Pre- or Post-<br />

Zone Level control to allow sett<strong>in</strong>g Pag<strong>in</strong>g Level <strong>in</strong>dependent of<br />

Zone Level. An <strong>in</strong>ternal Pag<strong>in</strong>g Priority switch allows a “master”<br />

pager to override non-priority pag<strong>in</strong>g <strong>in</strong> its assigned zones, while<br />

allow<strong>in</strong>g true dual zone <strong>in</strong>dependent pag<strong>in</strong>g. If no Pag<strong>in</strong>g Priority<br />

<strong>is</strong> selected, <strong>the</strong> Pag<strong>in</strong>g <strong>in</strong>puts mix toge<strong>the</strong>r for <strong>application</strong>s<br />

like karaoke.<br />

Four stereo Program <strong>in</strong>puts are provided with <strong>in</strong>dependent<br />

Input Level controls. Any one of <strong>the</strong> four Program <strong>in</strong>puts may<br />

Optional SCP2S Equalizer-only Security Cover<br />

be <strong>in</strong>dependently assigned <strong>in</strong> each Zone. One of <strong>the</strong> Program<br />

<strong>in</strong>puts <strong>is</strong> a gated Priority Program <strong>in</strong>put. When signal <strong>is</strong> detected<br />

at its <strong>in</strong>put, it overrides any non-priority Program selection <strong>in</strong> <strong>the</strong><br />

assigned Zones. The Priority detector features <strong>in</strong>ternal, adjustable<br />

Threshold and Release-Time controls.<br />

The <strong>CP64S</strong> has two Zone outputs: Zone 1 <strong>is</strong> stereo: Zone 2 <strong>is</strong><br />

mono. Each Zone features <strong>in</strong>dependent:<br />

• Level<br />

• Program Select<br />

• Ducker On/Off<br />

• Ducker Depth<br />

• Servo-Locked-Limiter<br />

• 7 Band EQ (±12 dB)<br />

Versatile wired remote control <strong>in</strong>terface ports are provided<br />

for Pag<strong>in</strong>g assignment, Zone Level and Zone Program source<br />

selection. Pag<strong>in</strong>g Zone and Source/Volume remote controls are<br />

available as accessories.<br />

Many options allow <strong>the</strong> <strong>in</strong>staller to determ<strong>in</strong>e exactly which<br />

controls are employee accessible. The SCP2S <strong>is</strong> an optional<br />

security cover for <strong>the</strong> <strong>CP64S</strong>’s front panel EQ section. Any or all<br />

o<strong>the</strong>r front panel knobs can be removed and replaced with hole<br />

plugs — six are <strong><strong>in</strong>cluded</strong> with <strong>the</strong> SCP2S. Front panel Ducker<br />

Depth controls are screw driver adjust. The remote controls allow<br />

blank Decora plates to be remote control security covers. The<br />

remote knobs can also be <strong>in</strong>dividually replaced with hole plugs.<br />

Features<br />

• Two fully <strong>in</strong>dependent gated Mic/L<strong>in</strong>e Pag<strong>in</strong>g Inputs<br />

• Pag<strong>in</strong>g Priority Assign<br />

• Page Duck<strong>in</strong>g<br />

• Page / Program / Zone Expansion<br />

• Three stereo Program Inputs<br />

• One gated stereo Priority Program Input<br />

• 7-Band graphic EQ for each Zone<br />

• Servo-Locked-Limiter for each Zone<br />

• Optional SCP2S Security Cover for EQ section only<br />

• Optional PR2 Remote Page Assign Remote<br />

• Optional ZR1 Remote Zone Level/Program Select Remote<br />

• Universal Internal Power Supply (100-240 VAC)<br />

<strong>Data</strong> <strong>Sheet</strong>-1


<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

Features and Specifications<br />

Parameter Specification Limit Units Conditions/Comments<br />

MIC/LINE PAGING INPUTS Two mono All controls duplicated for both <strong>in</strong>puts<br />

..........Input Type Euroblock Balanced; Instrumentation amplifier<br />

..........RFI Filter<br />

Yes<br />

..........Ga<strong>in</strong> range +30 to +60 2 dB Cont<strong>in</strong>uously adjustable<br />

..........Frequency Response 30 Hz to 40 kHz +0/-3 dB Maximum ga<strong>in</strong><br />

..........Input Referred No<strong>is</strong>e -125 1 dBu Ga<strong>in</strong>: 60 dB, Rs: 150 Ω, BW: 20 kHz<br />

..........CMR 40 m<strong>in</strong> dB 20 to 20 kHz<br />

..........THD+N .05 .01 % Ga<strong>in</strong>: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz<br />

..........Phantom Power +15 4% VDC Internal switch<br />

..........Mic Input impedance 500 1% Ω Each leg to ground<br />

..........L<strong>in</strong>e Pad 30 1 dB<br />

..........L<strong>in</strong>e Input impedance 14.5k 1% Ω Each leg to ground. Defeats phantom power<br />

..........Signal Detector Range off to +4 typ dBu Cont<strong>in</strong>uously adjustable<br />

..........Signal Detector Attack .5 typ msec Fixed<br />

..........Signal Detector Release 3 typ sec Fixed<br />

..........Overload Indicator +16 1 dBu 4 dB before clipp<strong>in</strong>g.<br />

..........Front Panel Zone Assign Remote, Z1, Z2, Both Z1 = Zone 1; Z2 = Zone 2<br />

..........Remote Zone Assign Off, Z1, Z2, Both Internal pull-up; Active low;<br />

Switch closure to ground or 5 volt TTL logic.<br />

..........Pre/Post Pag<strong>in</strong>g assign Summed with program Pre VCA or Post VCA via Internal switch<br />

..........Page Priority Assign P1 (Page 1)<br />

NO (none)<br />

P2 (Page 2)<br />

1 dBu Priority pager overrides non-priority pager only<br />

<strong>in</strong> assigned zones; Select<strong>in</strong>g NONE allows <strong>the</strong><br />

two pagers to mix.<br />

..........Pag<strong>in</strong>g Zone Level Adjust off to 0 dB Independent for each Zone<br />

..........Page Remote Selector 11 = Off<br />

10 = Z1 (Zone 1)<br />

1 dBu Internal pull-up. Active low;<br />

Switch closure to Ground or 5 volt TTL logic.<br />

01 = Z2 (Zone 2)<br />

00 = Both<br />

PROGRAM INPUTS Four stereo All controls duplicated for all four <strong>in</strong>puts<br />

..........Input Type RCA Unbalanced<br />

..........Input Level adjust off to 0 dB<br />

..........Frequency Response 10 Hz to 50 kHz +0/-3 dB<br />

..........Input impedance 10 k 20% Ω<br />

.....Priority Program Input<br />

...............Input Detector Range off to -35 typ dBu Internal trim, factory set to -50 dBu<br />

...............Release Time Range 5 to 20 typ sec Internal trim, factory set to 12 seconds<br />

...............Attack Time 50 typ msec For a 20 dB step; Fixed.<br />

...............Assign<br />

OFF, Z1, Z2 or Both<br />

EXPAND OUTPUTS<br />

All controls duplicated for both zones<br />

..........Number of Expand Outputs Two Z1 & Z2, both mono<br />

..........Expand Selector<br />

Zone<br />

Program only<br />

Page only<br />

Note: If a Page signal <strong>is</strong> summed Post-VCA, it<br />

<strong>is</strong> not present on <strong>the</strong> Expand Zone output. It <strong>is</strong><br />

available for <strong>the</strong> Expand Page output.<br />

..........Output Type Balanced Cross-coupled; Euroblock connector<br />

..........Ga<strong>in</strong>: Zone 12 1 dB<br />

....................Page/Program 6 1 dB<br />

..........Frequency Response 10 Hz to 50 kHz +0/-3 dB<br />

<strong>Data</strong> <strong>Sheet</strong>-2<br />

cont<strong>in</strong>ued...


<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

Parameter Specification Limit Units Conditions/Comments<br />

..........S/N -84 1 dBr re +4 dBu. BW: 20 Hz-20 kHz<br />

..........THD+N .05 .01 % +4 dBu, 1 kHz, BW: 80 kHz<br />

..........Crosstalk -75 max dB 1 kHz, Rs: 25 Ω, ch/ch<br />

..........Output impedance 100 1% Ω Each leg<br />

..........Maximum Output +24 dBu typ Ri: 2 kΩ<br />

ZONE OUTPUTS<br />

..........Number of Outputs Two Zone 1 Stereo, Zone 2 mono<br />

..........Output Type Euroblock Balanced; Cross-coupled<br />

..........Ga<strong>in</strong>: From Program Inputs 12 1 dB<br />

....................From Page Inputs 6 1 dB<br />

..........Frequency Response 10 Hz to 50 kHz +0/-3 dB<br />

..........S/N -84 1 dBr re +4 dBu. BW: 20 Hz-20 kHz<br />

..........THD+N .05 .01 % +4 dBu, 1 kHz, BW: 80 kHz<br />

..........Crosstalk -75 max dB 1 kHz, Rs: 25 Ω, (L/R or ch/ch)<br />

..........Output impedance 100 1% Ω Each leg<br />

..........Maximum Output +20 typ dBu Ri = 600 Ω<br />

..........Signal Present Indicator -20 typ dBu Maximum<br />

..........Overload Indicator +16 typ dBu 4 dB before clipp<strong>in</strong>g<br />

..........Ducker: Enable ON/OFF Independently defeatable for each Zone<br />

...............Depth Range -50 to -6 typ dB Cont<strong>in</strong>uously adjustable<br />

..........Limiter: Threshold Range -20 to +20 typ dB Cont<strong>in</strong>uously adjustable<br />

...............Attack Time 20 typ msec For a 10 dB step; Fixed.<br />

...............Release Time 250 typ msec For a 10 dB step; Fixed.<br />

...............Ratio 15:1 typ Soft knee.<br />

PROGRAM SELECTION<br />

..........Local (Front Panel) L1, L2, L3 or P (priority) Independent for each Zone<br />

..........Zone RMT Selector<br />

11 = L1<br />

10 = L2<br />

00 = L3<br />

01 = P<br />

Attenuation = 64 mV/dB<br />

Range 0 V to +5 V (0 dB to -78 dB)<br />

..........Zone RMT Volume<br />

(RMT engaged)<br />

..........Off Isolation -80 typ dB 1 kHz, Rs: 25 Ω<br />

EQ CIRCUITS<br />

..........Boost/Cut Range +12 to -12 .5 dB<br />

Internal pull-up. Active low.<br />

Switch closure to ground or 5 volt TTL.<br />

Gray Code logic.<br />

Control element: 2 kΩ pot, reverse-log taper;<br />

Or any ground referenced 0-5 VDC control.<br />

..........ISO Center Frequencies 40, 100, 250, 630, 1.6k,<br />

4k, 10k<br />

3% Hz Zone 1: Stereo 7-band.<br />

Zone 2: Mono 7-band.<br />

..........Filter Bandwidth 2 3% oct<br />

UNIT: Agency L<strong>is</strong>t<strong>in</strong>g<br />

UL/cUL/CE<br />

..........Universal L<strong>in</strong>e Voltage 100-240 VAC, 50/60 Hz 12 watts<br />

..........Construction<br />

All Steel<br />

..........Size 1.75"H x 19"W x 8.5"D 1U (4.4 cm x 48.3 cm x 21.6 cm)<br />

..........Weight 5 lb (2.3 kg)<br />

Shipp<strong>in</strong>g: Size 4.5" x 20.3" x 13.75" (11.5 cm x 52 cm x 35 cm)<br />

..........Weight 9 lb (4.1 kg)<br />

Note: 0 dBu = 0.775 Vrms<br />

<strong>Data</strong> <strong>Sheet</strong>-3


<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

Block Diagram<br />

P<br />

R<br />

O<br />

G<br />

R<br />

A<br />

M<br />

I<br />

N<br />

P<br />

U<br />

T<br />

S<br />

LINE 1<br />

LINE 2<br />

LINE 3<br />

PRIORITY<br />

LEFT<br />

RIGHT<br />

LEFT<br />

RIGHT<br />

LEFT<br />

RIGHT<br />

LEFT<br />

RIGHT<br />

0 dB<br />

0 dB<br />

0 dB<br />

0 dB<br />

+<br />

ZONE 2<br />

INPUT<br />

SELECTOR<br />

ZONE 1<br />

INPUT<br />

SELECTOR<br />

+<br />

6 dB<br />

+<br />

6 dB<br />

6 dB<br />

DEPTH<br />

-50dB<br />

-6dB<br />

PAGE<br />

DUCKER<br />

ON/OFF<br />

DEPTH<br />

-50dB<br />

-6dB<br />

PAGE<br />

DUCKER<br />

DEPTH<br />

PAGE<br />

DUCKER<br />

+<br />

+<br />

MONO<br />

*<br />

+<br />

SIG<br />

OL<br />

Z2 PRE PAGE<br />

SIG<br />

OL<br />

+<br />

PROGRAM<br />

ZONE<br />

PAGE<br />

Z2 PAGE<br />

PROGRAM<br />

ZONE<br />

PAGE<br />

Z1 PAGE<br />

6 dB<br />

+<br />

ZONE 2<br />

EXPAND<br />

-<br />

7-BAND EQ<br />

7-BAND EQ<br />

+<br />

6 dB<br />

ZONE 1<br />

EXPAND<br />

-<br />

Z2 LIMIT<br />

THRESHOLD<br />

-20dB<br />

+20dB<br />

Z2 VC<br />

Z1 VC<br />

Z1 LIMIT<br />

THRESHOLD<br />

-20dB<br />

+20dB<br />

+<br />

+<br />

+<br />

6 dB<br />

Z2 POST PAGE<br />

6 dB<br />

Z1 POST PAGE<br />

6 dB<br />

+<br />

ZONE 2<br />

-<br />

+<br />

ZONE 1 LEFT<br />

-<br />

+<br />

ZONE 1 RIGHT<br />

PRGM<br />

PRIORITY<br />

RELEASE<br />

TIME *<br />

12 24 SEC.<br />

ON/OFF<br />

Z1 PRE PAGE<br />

7-BAND EQ<br />

Z1 VC<br />

+ -<br />

11 OFF<br />

10 Z1<br />

01 Z2<br />

00 BOTH<br />

(ACTIVE LOW)<br />

REMOTE ZONE ASSIGN<br />

PAGE<br />

ASSIGN<br />

PAGE 1 + -<br />

+<br />

PAGE 2<br />

-<br />

P1<br />

P2<br />

P1<br />

LOCAL ZONE ASSIGN<br />

(FRONT PANEL)<br />

11 RMT<br />

P2<br />

10 Z1<br />

01 Z2<br />

00 BOTH<br />

P<br />

A<br />

G<br />

E<br />

I<br />

N<br />

PUTS<br />

A<br />

B<br />

COM<br />

A<br />

B<br />

COM<br />

A<br />

B<br />

COM<br />

A<br />

B<br />

COM<br />

15V<br />

PHTM PWR<br />

*<br />

MIC/<br />

LINE<br />

30dB<br />

PAD<br />

15V<br />

PHTM PWR<br />

*<br />

MIC/<br />

LINE<br />

30dB<br />

PAD<br />

TRIM<br />

TRIM<br />

-60dBu -35dBu<br />

PRGM PRIORITY<br />

THRESHOLD *<br />

P1 ACTIVE<br />

P2 ACTIVE<br />

30 TO 60dB<br />

30 TO 60dB<br />

PAGE DUCKER<br />

P1<br />

PAGER NONE<br />

ASSIGN<br />

LOGIC<br />

P2<br />

PAGE<br />

PRIORITY *<br />

PAGE 1 DETECT SENS.<br />

-<br />

+4dB<br />

DET<br />

P1<br />

PAGE 2 DETECT SENS.<br />

-<br />

+4dB<br />

DET<br />

P2<br />

Z1<br />

A<br />

Z2<br />

B<br />

COM<br />

PRIORITY<br />

ASSIGN<br />

OFF<br />

Z1<br />

Z2<br />

BOTH<br />

PAGE BRIDGE<br />

+<br />

+<br />

Z1 PAGE LEVEL<br />

Z2 PAGE LEVEL<br />

Z1 PAGE<br />

Z1 PRE PAGE<br />

*<br />

PRE/POST VCA<br />

Z1 POST PAGE<br />

Z2 PRE PAGE<br />

PRE/POST VCA<br />

*<br />

Z2 POST PAGE<br />

Z2 PAGE<br />

Z1<br />

REMOTE<br />

GRAY CODE<br />

Z2<br />

11 CH 1<br />

10 CH 2 PROGRAM<br />

01 CH 3<br />

00 CH 4<br />

SELECT<br />

Z1<br />

(ACTIVE LOW)<br />

LOCAL<br />

(FRONT PANEL)<br />

Z2<br />

PAGE<br />

OL<br />

OR<br />

A<br />

B<br />

COM<br />

A<br />

B<br />

COM<br />

A<br />

B<br />

COM<br />

A<br />

B<br />

COM<br />

ZONE 1<br />

LEVEL<br />

CHANNEL<br />

SELECT<br />

LOGIC<br />

RMT<br />

LOCAL<br />

(FRONT PANEL)<br />

ZONE 2<br />

LEVEL<br />

RMT<br />

LOCAL<br />

(FRONT PANEL)<br />

+5<br />

+5<br />

AUTO FADE<br />

RMT SEL<br />

ZONE 1<br />

RMT/LOCAL<br />

ZONE 2<br />

RMT/LOCAL<br />

RMT<br />

RMT<br />

+ Z1 VC +<br />

Z2 VC<br />

* INTERNAL CONTROLS<br />

<strong>Data</strong> <strong>Sheet</strong>-4


L2<br />

L1<br />

PROGRAM SELECT<br />

2<br />

4 6<br />

0<br />

L3<br />

LEVEL<br />

10<br />

P<br />

8<br />

3<br />

6<br />

12<br />

24<br />

1<br />

Limit<br />

Comp<br />

Exp<br />

Fault<br />

Load<br />

Ready<br />

3<br />

6<br />

12<br />

24<br />

2<br />

Limit<br />

Comp<br />

Exp<br />

dB Headroom dB Headroom dB Headroom dB Headroom<br />

Fault<br />

Load<br />

Ready<br />

3<br />

6<br />

12<br />

24<br />

3<br />

Limit<br />

Comp<br />

Exp<br />

Fault<br />

Load<br />

Ready<br />

3<br />

6<br />

12<br />

24<br />

4 ON<br />

Limit<br />

Comp<br />

Exp<br />

Fault<br />

Load<br />

Ready<br />

MA 4<br />

DIGITAL<br />

AMPLIFIER<br />

L2<br />

L1<br />

PROGRAM SELECT<br />

2<br />

4 6<br />

0<br />

L3<br />

LEVEL<br />

10<br />

P<br />

8<br />

<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

L2 L3<br />

L1 P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 1 ASSIGN<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 2 ASSIGN<br />

ZR1<br />

PR2<br />

Remote Controls<br />

Two optional wired remote control units are available. The PR2<br />

allows remote control of Page 1 and Page 2 Zone Assign selection.<br />

The ZR1 allows remote control of Zone Level and Zone<br />

Program selection. One PR2 and two ZR1 remotes may be<br />

used with each <strong>CP64S</strong>. The PR2 and ZR1 may be <strong>in</strong>stalled <strong>in</strong><br />

standard electrical boxes (m<strong>in</strong>imum depth 2.25"). The remotes<br />

connect to <strong>the</strong> <strong>CP64S</strong> through Euroblock connectors.<br />

The PR2 <strong>is</strong> a 5-wire remote with 2 bits to select Page 1 Assign,<br />

one wire for shield/gnd and 2 bits for Page 2 Assign. Selector<br />

logic <strong>is</strong> active low BCD with pull-up provided <strong>in</strong> <strong>the</strong> <strong>CP64S</strong>.<br />

Control may be a simple switch closure to ground or 5 volt TTL.<br />

Page 1 and Page 2 bits may be paralleled so that one switch controls<br />

both Page Assigns. Remote control <strong>is</strong> <strong>in</strong>itiated by sett<strong>in</strong>g <strong>the</strong><br />

front panel Pag<strong>in</strong>g Zone Assign selector to RMT.<br />

The ZR1 <strong>is</strong> a 5-wire remote with 2 bits for Zone Program<br />

selection (active low Gray Code), a common shield/ground and<br />

two wires for ratiometric DC control of Zone Level. Zone 1 and<br />

Zone 2 ZR1 remote ports may be paralleled so that a s<strong>in</strong>gle remote<br />

controls both Zones. Selector logic <strong>is</strong> active low Gray Code<br />

with pull-up provided <strong>in</strong> <strong>the</strong> <strong>CP64S</strong>. Control may be a simple<br />

switch closure to ground or 5 volt TTL. Remote control for each<br />

zone <strong>is</strong> <strong>in</strong>itiated by engag<strong>in</strong>g <strong>the</strong> RMT switch (located on <strong>the</strong><br />

front panel) for that Zone.<br />

For <strong>in</strong>stallations that require a volume remote but don't need<br />

<strong>the</strong> program selection of <strong>the</strong> ZR1, <strong>Rane</strong> makes <strong>the</strong> model VR1<br />

Volume Remote.<br />

Example System: Retail Store<br />

<strong>CP64S</strong><br />

100-240 V<br />

50/60 Hz 12 WATTS<br />

RANE CORP. MADE IN U.S.A.<br />

COMMERCIAL AUDIO<br />

EQUIPMENT 24TJ<br />

R<br />

ACN 001 345 482<br />

ZONE 2<br />

Z2 PGM Z2 LEVEL REMOTES<br />

OUTPUTS Z2 EXPAND Z2 MONO PROGRAM INPUTS<br />

REMOTE PAGE REMOTE 1 INPUT 1 PAGING INPUTS<br />

PRIORITY<br />

ZONE ASSIGN WIRING<br />

WIRING<br />

LIMITER<br />

ALL AUDIO AND<br />

ZONE 1 ZONE 2<br />

ASSIGN<br />

PAGE 2 PAGE 1<br />

MIN MAX<br />

REMOTES ARE<br />

ZONE L<br />

L<br />

Vr Vc<br />

+8 +8<br />

Z1 Z2<br />

TRIM TRIM<br />

CLASS 2 WIRING<br />

off 1<br />

ZONE 2 ZONE 1<br />

2<br />

EXPAND OUT EXPAND OUT<br />

+30 +60 +30 +60<br />

–20 +20 –20 +20<br />

R<br />

R<br />

OL<br />

1&2<br />

PAGE 2 PAGE 1<br />

Z1 PGM Z1 LEVEL<br />

D1 D0 Vr Vc<br />

ZONE PAGE<br />

2<br />

PGM<br />

ZONE 1<br />

ZONE PAGE<br />

1<br />

PGM<br />

Z1 EXPAND Z1 RIGHT Z1 LEFT<br />

+ – + – + –<br />

PRIORITY 3 2 1<br />

DETECT THRESHOLD<br />

REMOTE 2 INPUT 2<br />

Z2 Z1 + –<br />

Z2 Z1R Z1L EX1 EX2<br />

PRIORITY 2<br />

IN1 IN2 PRIORITY 1<br />

MIC<br />

LINE<br />

MIC<br />

LINE<br />

MA 4<br />

MULTICHANNEL<br />

AMPLIFIER<br />

CD<br />

PLAYER<br />

PRE-RECORDED<br />

ADVERTISEMENT<br />

OR BREAK BELL<br />

MUSIC<br />

SERVICE<br />

DVR<br />

62 1:58<br />

TELEPHONE HOLD MUSIC<br />

TELEPHONE<br />

PAGE OUT<br />

DISTRIBUTED OUTPUTS REQUIRE<br />

MT 4 TRANSFORMER ACCESSORY<br />

ZR 1<br />

DISTRIBUTED<br />

ZR 1<br />

STEREO<br />

DISTRIBUTED<br />

PROGRAM<br />

SELECT<br />

LEVEL<br />

ZONE 2<br />

PROGRAM<br />

SELECT<br />

LEVEL<br />

ZONE 1 EXPAND 1<br />

RETAIL / SHOP FLOOR<br />

MEETING / DEMO ROOM<br />

OFFICE PAGE<br />

<strong>Data</strong> <strong>Sheet</strong>-5


TRANSFORMER<br />

0 0<br />

3<br />

6<br />

12<br />

3<br />

6<br />

12<br />

3<br />

6<br />

12<br />

0 0<br />

dB<br />

CHANNEL OUTPUT HEADROOM<br />

3<br />

6<br />

12<br />

dB<br />

CHANNEL OUTPUT HEADROOM<br />

0<br />

3<br />

6<br />

12<br />

0<br />

3<br />

6<br />

12<br />

POWER<br />

POWER<br />

POWER<br />

POWER<br />

AMPLIFIER<br />

AMPLIFIER<br />

<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

Example System: Auto Dealer and Service<br />

<strong>CP64S</strong><br />

100-240 V<br />

50/60 Hz 12 WATTS<br />

RANE CORP. MADE IN U.S.A.<br />

MA 3<br />

MULTICHANNEL<br />

AMPLIFIER<br />

COMMERCIAL AUDIO<br />

EQUIPMENT 24TJ<br />

R<br />

REMOTES<br />

OUTPUTS<br />

PROGRAM INPUTS<br />

PAGING INPUTS<br />

Z2 LEVEL<br />

REMOTE PAGE<br />

Z2 PGM Z2 EXPAND Z2 MONO REMOTE 1 INPUT 1<br />

ZONE ASSIGN WIRING<br />

WIRING<br />

LIMITER<br />

PRIORITY<br />

ALL AUDIO AND<br />

ASSIGN<br />

L<br />

L<br />

PAGE 2<br />

ZONE 1 ZONE 2 PAGE 1<br />

MIN MAX<br />

REMOTES ARE<br />

ZONE<br />

Z1 Z2<br />

TRIM TRIM<br />

Vr Vc<br />

CLASS 2 WIRING<br />

+8 +8<br />

off 1<br />

ZONE 2 ZONE 1<br />

2<br />

EXPAND OUT EXPAND OUT<br />

R<br />

R<br />

+30 +60 +30 +60<br />

OL<br />

–20 +20 –20 +20<br />

1&2<br />

PAGE 2 PAGE 1<br />

ZONE PAGE ZONE PAGE<br />

PRIORITY 3 2 1<br />

DETECT THRESHOLD<br />

MIC LINE MIC LINE<br />

Z1 PGM Z1 LEVEL 2<br />

Z1 EXPAND Z1 RIGHT Z1 LEFT<br />

REMOTE 2 INPUT 2<br />

1<br />

PGM PGM<br />

+ –<br />

+ – + –<br />

Z2 Z1 + –<br />

D1 D0 Vr Vc<br />

ZONE 2 ZONE 1<br />

Z2 Z1R Z1L EX1 EX2<br />

PRIORITY 2 IN2 IN1 TO SET PAGE<br />

PRIORITY 3 PRIORITY 4<br />

MUSIC<br />

SUM PAGE 2<br />

POST VCA<br />

PRIORITY 2 PRIORITY 1 PRIORITY<br />

SUM PAGE 1<br />

& PAGE 2<br />

POST VCA<br />

SERVICE<br />

ACN 001 345 482<br />

1 2<br />

3<br />

MA 3<br />

MULTICHANNEL<br />

EXPAND 2<br />

MUSIC ON HOLD<br />

CD<br />

10 8:58<br />

PR 2<br />

TELEPHONE<br />

KEY SERVICE UNIT<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 1 ASSIGN<br />

ZR 1 ZR 1<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 2 ASSIGN<br />

L2 L3<br />

L1 P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

DISTRIBUTED<br />

(USE MT 4<br />

TRANSFORMER<br />

BELOW)<br />

L2 L3<br />

L1 P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

RIGHT<br />

ZONE 2 ZONE 1<br />

LEFT<br />

12:00<br />

MASTER<br />

PAGE<br />

RECEPTION<br />

SALES & CREDIT<br />

OFFICES<br />

<strong>CP64S</strong><br />

100-240 V<br />

50/60 Hz 12 WATTS<br />

RANE CORP. MADE IN U.S.A.<br />

COMMERCIAL AUDIO<br />

EQUIPMENT 24TJ<br />

R<br />

ACN 001 345 482<br />

ZONE 2<br />

Z1 PGM Z1 LEVEL<br />

D1 D0 Vr Vc<br />

ZONE 1<br />

ZONE PAGE<br />

1<br />

PGM<br />

SALES FLOOR<br />

Z1 EXPAND Z1 RIGHT Z1 LEFT<br />

+ – + – + –<br />

Z2<br />

Z1L<br />

EX2<br />

PRIORITY 3<br />

PROMO DVD<br />

PRIORITY 3 2 1<br />

EXPAND 1 EMERGENCY PAGE<br />

DETECT THRESHOLD<br />

IN2<br />

PRIORITY 1<br />

Z2 PGM Z2 LEVEL REMOTES<br />

OUTPUTS Z2 EXPAND Z2 MONO PROGRAM INPUTS<br />

REMOTE PAGE REMOTE 1 INPUT 1 PAGING INPUTS<br />

PRIORITY<br />

ZONE ASSIGN WIRING<br />

WIRING<br />

LIMITER<br />

ALL AUDIO AND<br />

ZONE 1 ZONE 2<br />

ASSIGN<br />

PAGE 2 PAGE 1<br />

MIN MAX<br />

REMOTES ARE<br />

ZONE L<br />

L<br />

Vr Vc<br />

+8 +8<br />

Z1 Z2<br />

TRIM TRIM<br />

CLASS 2 WIRING<br />

off 1<br />

ZONE 2 ZONE 1<br />

2<br />

EXPAND OUT EXPAND OUT<br />

+30 +60 +30 +60<br />

–20 +20 –20 +20<br />

R<br />

R<br />

OL<br />

1&2<br />

PAGE 2 PAGE 1<br />

ZONE PAGE<br />

2<br />

PGM<br />

MIC LINE<br />

REMOTE 2 INPUT 2<br />

Z2 Z1 + –<br />

IN1 PRIORITY 2<br />

SET PAGE<br />

PRIORITY<br />

TO P2<br />

MIC<br />

LINE<br />

MA 3<br />

MULTICHANNEL<br />

AMPLIFIER<br />

OPTIONAL SOURCES<br />

PRIORITY 4<br />

PR 2<br />

OFF Z1 Z2 BOTH<br />

MIC OR<br />

TELEPHONE<br />

PAGE TO<br />

SERVICE<br />

1 2<br />

3<br />

MA 3<br />

MULTICHANNEL<br />

CD<br />

10 8:58<br />

PAGE 1 ASSIGN<br />

HOLE PLUG<br />

MT 4 MULTICHANNEL TRANSFORMER<br />

MT 4<br />

MULTICHANNEL<br />

SERVICE RECEPTION<br />

ZR 1 ZR 1<br />

L2 L3<br />

L1 P<br />

DISTRIBUTED<br />

L2 L3<br />

DISTRIBUTED DISTRIBUTED<br />

L1<br />

P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

PROGRAM SELECT<br />

ZONE 2 ZONE 1<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

SERVICE WRITER<br />

AND PARTS ROOM<br />

SERVICE BAYS<br />

EXPAND 2<br />

RESTROOMS<br />

<strong>Data</strong> <strong>Sheet</strong>-6


1<br />

2<br />

3<br />

4 ON<br />

3 Limit Fault 3 Limit Fault 3 Limit Fault 3 Limit Fault<br />

6 Comp Load 6 Comp Load 6 Comp Load 6 Comp Load<br />

12 Exp Ready 12 Exp Ready 12 Exp Ready 12 Exp Ready<br />

24<br />

24<br />

24<br />

24<br />

dB Headroom dB Headroom dB Headroom dB Headroom<br />

L2 L3<br />

L1 P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

1<br />

2<br />

3<br />

4 ON<br />

3 Limit Fault 3 Limit Fault 3 Limit Fault 3 Limit Fault<br />

6 Comp Load 6 Comp Load 6 Comp Load 6 Comp Load<br />

12 Exp Ready 12 Exp Ready 12 Exp Ready 12 Exp Ready<br />

24<br />

24<br />

24<br />

24<br />

dB Headroom dB Headroom dB Headroom dB Headroom<br />

MA 4<br />

DIGITAL<br />

AMPLIFIER<br />

L2 L3<br />

L1 P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

MA 4<br />

DIGITAL<br />

AMPLIFIER<br />

TRANSFORMER<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 1 ASSIGN<br />

Z2<br />

BOTH<br />

PAGE 2 ASSIGN<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 1 ASSIGN<br />

Z2<br />

BOTH<br />

PAGE 2 ASSIGN<br />

<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

Example System: Karaoke D<strong>in</strong>er<br />

<strong>CP64S</strong><br />

COMMERCIAL AUDIO<br />

100-240 V<br />

EQUIPMENT 24TJ<br />

50/60 Hz 12 WATTS<br />

RANE CORP. MADE IN U.S.A.<br />

R<br />

ACN 001 345 482<br />

ZONE 2<br />

Z2 PGM Z2 LEVEL REMOTES<br />

OUTPUTS Z2 EXPAND Z2 MONO PROGRAM INPUTS<br />

REMOTE PAGE REMOTE 1 INPUT 1 PAGING INPUTS<br />

PRIORITY<br />

ZONE ASSIGN WIRING<br />

WIRING<br />

LIMITER<br />

ALL AUDIO AND<br />

ZONE 1 ZONE 2<br />

ASSIGN<br />

PAGE 2 PAGE 1<br />

MIN MAX<br />

REMOTES ARE<br />

ZONE L<br />

L<br />

Vr Vc<br />

Z1 Z2<br />

TRIM TRIM<br />

CLASS 2 WIRING<br />

+8 +8<br />

off 1<br />

ZONE 2 ZONE 1<br />

2<br />

EXPAND OUT EXPAND OUT<br />

+30 +60 +30 +60<br />

–20 +20 –20 +20<br />

R<br />

R<br />

OL<br />

1&2<br />

PAGE 2 PAGE 1<br />

ZONE PAGE ZONE PAGE<br />

DETECT THRESHOLD<br />

MIC LINE MIC LINE<br />

Z1 PGM Z1 LEVEL 2 1<br />

Z1 EXPAND Z1 RIGHT Z1 LEFT<br />

PRIORITY 3 2 1<br />

REMOTE 2 INPUT 2<br />

D1 D0 Vr Vc PGM PGM<br />

+ – + – + –<br />

Z2 Z1 + –<br />

ZONE 1 Z2 EX2 Z1R Z1L<br />

PRIORITY 1<br />

IN2 IN1<br />

ZR 1<br />

PR 2<br />

MA 4<br />

MULTICHANNEL AMPLIFIER<br />

L2 L3<br />

L1 P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

LEVEL<br />

PROGRAM<br />

SELECT<br />

LEVEL<br />

TRANS-<br />

FORMER<br />

SATELLITE<br />

AUDIO<br />

MUSIC<br />

SERVICE<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 1 ASSIGN<br />

Z1 Z2<br />

OFF BOTH<br />

PAGE 2 ASSIGN<br />

PAGE IN<br />

LOUNGE OR<br />

DINING AREA<br />

SINGER 1<br />

1-1-05<br />

ZR 1<br />

KARAOKE DVD<br />

L2 L3<br />

L1 P<br />

PROGRAM SELECT<br />

4 6<br />

2 8<br />

0 10<br />

PROGRAM<br />

SELECT<br />

LEVEL<br />

ZONE 2<br />

ZONE 1<br />

CH 68<br />

DVR<br />

SINGER 2<br />

or ANNOUNCER<br />

or DINING PAGE<br />

LEVEL<br />

62 1:58<br />

DINING AREA<br />

KARAOKE LOUNGE<br />

OTHER PROGRAM SOURCE<br />

Example System: Restaurant<br />

<strong>CP64S</strong><br />

100-240 V<br />

50/60 Hz 12 WATTS<br />

RANE CORP. MADE IN U.S.A.<br />

Z2 PGM Z2 LEVEL REMOTES<br />

OUTPUTS Z2 EXPAND Z2 MONO PROGRAM INPUTS<br />

REMOTE PAGE REMOTE 1 INPUT 1 PAGING INPUTS<br />

PRIORITY<br />

ZONE ASSIGN WIRING<br />

WIRING<br />

LIMITER<br />

ALL AUDIO AND<br />

ZONE 1 ZONE 2<br />

ASSIGN<br />

PAGE 2 PAGE 1<br />

MIN MAX<br />

REMOTES ARE<br />

ZONE L<br />

L<br />

Vr Vc<br />

Z1 Z2<br />

TRIM TRIM<br />

CLASS 2 WIRING<br />

+8 +8<br />

off<br />

R<br />

1<br />

ZONE 2 ZONE 1<br />

2<br />

EXPAND OUT EXPAND OUT<br />

+30 +60 +30 +60<br />

–20 +20 –20 +20<br />

R<br />

R<br />

OL<br />

1&2<br />

PAGE 2 PAGE 1<br />

ZONE PAGE ZONE PAGE<br />

DETECT THRESHOLD<br />

MIC LINE MIC LINE<br />

Z1 PGM Z1 LEVEL 2 1<br />

Z1 EXPAND Z1 RIGHT Z1 LEFT<br />

PRIORITY 3 2 1<br />

REMOTE 2 INPUT 2<br />

D1 D0 Vr Vc PGM PGM<br />

+ – + – + –<br />

Z2 Z1 + –<br />

ZONE 1 ZONE 2<br />

Z2 Z1R Z1L EX1 EX2<br />

IN1 IN2<br />

PRIORITY 3 PRIORITY 4<br />

PRIORITY 2 PRIORITY 1<br />

COMMERCIAL AUDIO<br />

EQUIPMENT 24TJ<br />

ACN 001 345 482<br />

MA 4<br />

MULTICHANNEL AMPLIFIER<br />

1 2 3 4<br />

TO TELEPHONE<br />

MUSIC-ON-HOLD<br />

MUSIC<br />

SERVICE<br />

PR 2<br />

PAGE 1<br />

CH 68<br />

PAGE<br />

ASSIGN<br />

MT 4 70V<br />

TRANSFORMER<br />

DVR<br />

10 8:58<br />

Z1<br />

OFF<br />

HOLE<br />

PLUG<br />

MT 4<br />

MULTICHANNEL<br />

CD<br />

RECEPTION<br />

STATION<br />

ZONE 2<br />

ZONE 2<br />

EXPAND<br />

ZONE 1<br />

ZONE 1<br />

EXPAND<br />

PR 2<br />

HOLE<br />

PLUG<br />

PAGE 2<br />

ZR 1<br />

DISTRIBUTED<br />

PROGRAM<br />

SELECT<br />

LEVEL<br />

DISTRIBUTED<br />

PATIO<br />

DINING<br />

ZR 1<br />

DISTRIBUTED<br />

PROGRAM<br />

SELECT<br />

LEVEL<br />

10 8 19:58<br />

DISTRIBUTED<br />

RESTROOMS<br />

JUKEBOX<br />

Z1<br />

OFF<br />

OFFICE<br />

PAGE<br />

TELEPHONE<br />

KEY SERVICE<br />

MIC OR<br />

TELEPHONE<br />

PAGE<br />

DINING ROOM<br />

LOUNGE<br />

OFFICES<br />

<strong>Data</strong> <strong>Sheet</strong>-7


<strong>CP64S</strong><br />

COMMERCIAL PROCESSOR<br />

Rear Panel<br />

<strong>CP64S</strong><br />

100-240 V<br />

50/60 Hz 12 WATTS<br />

RANE CORP. MADE IN U.S.A.<br />

COMMERCIAL AUDIO<br />

EQUIPMENT 24TJ<br />

R<br />

ACN 001 345 482<br />

Z2 PGM Z2 LEVEL REMOTES<br />

OUTPUTS Z2 EXPAND Z2 MONO PROGRAM INPUTS<br />

REMOTE PAGE REMOTE 1 INPUT 1 PAGING INPUTS<br />

PRIORITY<br />

ZONE ASSIGN WIRING<br />

WIRING<br />

LIMITER<br />

ALL AUDIO AND<br />

ZONE 1 ZONE 2<br />

ASSIGN<br />

PAGE 2 PAGE 1<br />

MIN MAX<br />

REMOTES ARE<br />

ZONE L<br />

L<br />

Vr Vc<br />

Z1 Z2<br />

TRIM TRIM<br />

CLASS 2 WIRING<br />

+8 +8<br />

off 1<br />

ZONE 2 ZONE 1<br />

2<br />

EXPAND OUT EXPAND OUT<br />

+30 +60 +30 +60<br />

–20 +20 –20 +20<br />

R<br />

R<br />

OL<br />

1&2<br />

PAGE 2 PAGE 1<br />

ZONE PAGE ZONE PAGE<br />

DETECT THRESHOLD<br />

MIC LINE MIC LINE<br />

Z1 PGM Z1 LEVEL 2 1<br />

Z1 EXPAND Z1 RIGHT Z1 LEFT<br />

PRIORITY 3 2 1<br />

REMOTE 2 INPUT 2<br />

D1 D0 Vr Vc PGM PGM<br />

+ – + – + –<br />

Z2 Z1 + –<br />

Architectural Specifications<br />

The processor shall provide two fully <strong>in</strong>dependent gated pag<strong>in</strong>g<br />

<strong>in</strong>puts, three l<strong>in</strong>e-level non-priority program <strong>in</strong>puts and one<br />

gated l<strong>in</strong>e-level priority program <strong>in</strong>put. Two zone outputs shall<br />

be served. Zone 1 shall be a stereo zone with balanced, crosscoupled<br />

outputs. Zone 2 shall be a mono zone with a balanced<br />

cross-coupled output. Mono expansion ports for page, program<br />

or zone signals shall be provided for each zone. Wired remote<br />

control ports shall be provided for pag<strong>in</strong>g zone assign, zone<br />

program select and zone level.<br />

Page <strong>in</strong>puts shall use a 5-p<strong>in</strong> Euroblock connector. Pag<strong>in</strong>g<br />

controls shall <strong>in</strong>clude:<br />

• 30 dB mic/l<strong>in</strong>e <strong>in</strong>put pad.<br />

• Input ga<strong>in</strong> trim range of 30 dB to 60 dB.<br />

• Mic gate threshold (range -∞ to +4 dBu).<br />

• 15 volt phantom power (<strong>in</strong>ternal switch).<br />

• Pag<strong>in</strong>g priority (page 1, none, page 2; <strong>in</strong>ternal switch).<br />

• Pre- or post-zone level summ<strong>in</strong>g (<strong>in</strong>ternal switch).<br />

• Front panel pag<strong>in</strong>g zone assign (Remote, Z1, Z2, Both).<br />

• Remote pag<strong>in</strong>g zone assign (Off, Z1, Z2, Both).<br />

• Pag<strong>in</strong>g zone level.<br />

Each Program <strong>in</strong>put shall have stereo RCA <strong>in</strong>put jacks and<br />

<strong>in</strong>dependent <strong>in</strong>put level control. The priority program assign<br />

switch shall provide priority program override to zone 1, zone 2,<br />

both, or nei<strong>the</strong>r (off). The gated priority program <strong>in</strong>put shall<br />

have <strong>in</strong>ternally adjustable threshold and release time controls.<br />

Zone outputs shall use 3-p<strong>in</strong> Euroblock connectors. Zone<br />

controls shall <strong>in</strong>clude:<br />

• Ducker on/off<br />

• Ducker depth (-6 to -50 dB)<br />

• Program select (L1, L2, L3, P)<br />

• Zone level<br />

• 7-band graphic equalizer (±12 dB)<br />

• Servo-Locked-Limiter threshold (-20 to +20 dBu)<br />

• Mono switch for Zone 1 (<strong>in</strong>ternal)<br />

• Remote engage switch<br />

Wired remote ports shall use 3-p<strong>in</strong> Euroblock connectors.<br />

Remote logic shall be active low with <strong>in</strong>ternal pull-up. Remote<br />

level control shall be ratiometric DC control with 5 volt<br />

reference.<br />

The unit shall be capable of operation by means of its own<br />

built-<strong>in</strong> universal power supply operat<strong>in</strong>g at 100-240 VAC and<br />

meet CE requirements. The unit shall be UL and cUL l<strong>is</strong>ted. The<br />

unit shall be entirely constructed from cold-rolled steel.<br />

Reliability and efficiency are to be primary design considerations.<br />

The unit shall be a <strong>Rane</strong> Corporation <strong>CP64S</strong> Commercial<br />

Processor.<br />

Available Accessories<br />

• SCP2S Security Cover (for EQ section)<br />

• SC 1.7 Security Cover (for entire front panel)<br />

• PR2 Page Assign Remote Control<br />

• ZR1 Zone Source/Volume Remote Control<br />

• VR1 Volume Remote Control<br />

• Hole Plugs (6 Provided with SCP2S)<br />

©<strong>Rane</strong> Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 USA TEL 425-355-6000 FAX 425-347-7757 WEB rane.com<br />

<strong>Data</strong> <strong>Sheet</strong>-8<br />

All features & specifications subject to change without notice. DOC 102906