15.06.2014 Views

SensorPulse - Rometec srl

SensorPulse - Rometec srl

SensorPulse - Rometec srl

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Rometec</strong> <strong>srl</strong> - www.rometec.it - <strong>Rometec</strong> <strong>srl</strong> - www.rometec.it - <strong>Rometec</strong> <strong>srl</strong> - www.rometec.it<br />

<strong>SensorPulse</strong> ®<br />

Series MSP<br />

Open I/O ® Family<br />

Single Channel Modules<br />

®<br />

Enclosure<br />

Cover<br />

+ OUT PLC<br />

88<br />

(3.5)<br />

Green<br />

Indicator<br />

Red<br />

Indicator<br />

Terminal Set<br />

Screw (6)<br />

68<br />

(2.7)<br />

- In<br />

MSP-C-IN<br />

+ In -VDC<br />

+VDC<br />

12<br />

(0.50)<br />

The <strong>SensorPulse</strong> ® MSP family of products have begun<br />

a revolution on how analog signals connect to a<br />

Programmable Logic Controller (PLC). Analog input signals<br />

are digitally scaled, amplified, linearized, isolated,<br />

and converted to a high resolution 24 VDC pulse, all<br />

within a 12 mm wide DIN rail terminal block. Our<br />

patented 16-bit, single-wire, communication protocol,<br />

communicates with any one of the discrete inputs (or<br />

outputs) of a PLC.<br />

THE RIGHT SIGNAL PROCESSING<br />

MODULE FOR THE JOB<br />

<strong>SensorPulse</strong> ® offers five analog input signal types (to a<br />

discrete input of a PLC): Current, Voltage,<br />

Thermocouple, RTD, and Potentiometer. <strong>SensorPulse</strong> ®<br />

also offers two analog output signal types (from a discrete<br />

output of a PLC): Current and Voltage. All models<br />

are engineered to meet high quality and performance<br />

standards with advanced features including: 16-bit resolution;<br />

two-way optical and transformer isolation (to<br />

eliminate the concern of ground loops and noise); short<br />

circuit and reverse power protection; and a broad operating<br />

temperature range of -40 to 75°C.<br />

A NEW BREED OF PLC ANALOG I/O MODULE<br />

The MSP Analog I/O allows PLC users the freedom to<br />

distribute the I/O where the signal is being generated...the<br />

freedom to eliminate the cost of a separate signal<br />

conditioner and other hardware...the freedom to<br />

expand I/O one channel at a time...the freedom to connect<br />

to any ladder logic-based PLC. A small ladder program<br />

loaded into the PLC enables the controller to capture<br />

and process the analog signal.<br />

FLEXIBLE, USER-FRIENDLY CONFIGURATION<br />

MSP analog I/O modules can be shipped with the<br />

default input/output calibration or the customer can<br />

specify an application specific calibration for true Plug<br />

‘n’ Play installation. The optional SignalFlex configuration<br />

software and cable allows the user to re-configure<br />

and re-calibrate MSP units at will. This Windows ® -<br />

based software operates on a PC running the<br />

Windows ® 3.1 , Windows ® 95, or Windows ® 98 operating<br />

system or on a Palmtop running Windows ® CE. For<br />

further flexibility and convenience, configuration<br />

changes can be made without removing the unit from<br />

the control system.<br />

FEATURES<br />

• Single channel analog input or output expansion<br />

to/from most PLCs even micros.<br />

• Plug ‘n’ Play installation.<br />

• Simple software based configuration and calibration.<br />

• Input to output isolation minimizes ground loop problems<br />

and protects upstream equipment.<br />

• No potentiometers to vibrate and drift.<br />

• Small DIN rail terminal block package (only 12 mm<br />

wide).<br />

• -40 to 75°C ambient operating range.<br />

• Low power (less than 50 mA).<br />

• 16-bit resolution with 0.05% F.S. accuracy.<br />

• Wide range of inputs: Current, Voltage,<br />

Thermocouple, RTD, Potentiometer, Frequency.<br />

• Voltage or Current outputs.<br />

ACCESSORIES<br />

SP-MSFCCA1 . . . . . . SignalFlex Configuration Cable & Software.<br />

SP-DIN1 . . . . . . . . . . DIN Rail, 1 meter length, 32 mm W x 15 mm H, EN 50035 Compliant.<br />

SP-DIN3 . . . . . . . . . . DIN Rail, 1 meter length, 35 mm W x 7.5 mm H, EN 50022 Compliant.<br />

SP-TORQ1 . . . . . . . . 2 in lb (32 in oz) Torque Screwdriver.<br />

SP-BIT1 . . . . . . . . . . 1/4˝ hex bit: Width .138 in Length 1 Screw Size: 2F-3R.<br />

SP-BIT2 . . . . . . . . . . 1/4˝ hex bit: Width .138 in Length 1-1/2 Screw Size: 2F-3R.<br />

SP-STOP1 . . . . . . . . .Gray End Stop for DIN 1 & 3, Screw Clamp.<br />

SPS-4W . . . . . . . . . . Power Supply, 4 Watts 24 Volts @ 110 mA. (see page 26)<br />

TRADEMARK ACKNOWLEDGMENTS - <strong>SensorPulse</strong> ® , MSC, MSP, ESP, OPEN I/O ® , and SIGNAL I/O are registered trademarks of <strong>SensorPulse</strong> Corp. Patent No.<br />

5,416,480. Windows/PC and Windows/CE HPC are registered trademarks of Microsoft Corp. Other products are trademarks of their respective trademark holders.<br />

8<br />

<strong>SensorPulse</strong> ® Corp./3999 Hupp. Rd. Bldg R-6-4/Kingsbury, IN 46345 • Phone: 219 393-7218/800 447-5900 • Fax: 219 393-7318 • email: info@sensorpulse.com<br />

<strong>Rometec</strong> <strong>srl</strong> - www.rometec.it - <strong>Rometec</strong> <strong>srl</strong> - www.rometec.it - <strong>Rometec</strong> <strong>srl</strong> - www.rometec.it

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!