internal cooling for the blow molding industry - Blow Moulding Controls
internal cooling for the blow molding industry - Blow Moulding Controls
internal cooling for the blow molding industry - Blow Moulding Controls
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
THE BLOW AIR CHILLER<br />
The <strong>Blow</strong> Air Chiller (BAC) is a more sophisticated compressed air chiller. It is designed by Rainer Farrag to chill <strong>the</strong> compressed air<br />
<strong>for</strong> <strong>the</strong> <strong>blow</strong>ing process with <strong>internal</strong> air <strong>cooling</strong> systems to a temperature as low as -35ºC [-31ºF].<br />
The compressed air must be dried to a dew point lower than -<br />
40ºC [-40ºF] be<strong>for</strong>e it is chilled in <strong>the</strong> heat exchanger<br />
(evaporator) of <strong>the</strong> integrated chilling unit. The BAC units<br />
require a good quality of compressed air supplied with a<br />
pressure dew point not higher than 10ºC [50ºF] and an oil<br />
content lower than 0.05ppm. This is a standard air quality in a<br />
standard compressed air supply system with refrigeration dryer,<br />
a functioning moisture separator and standard oil filters.<br />
The BAC units are water cooled compressed air chillers and<br />
<strong>the</strong>y require small amounts of filtered <strong>cooling</strong> water at a<br />
temperature not higher than 15ºC [60ºF].<br />
There is virtually no maintenance required when good air and<br />
water quality (<strong>industry</strong> standard) is provided <strong>for</strong> <strong>the</strong> <strong>internal</strong> air<br />
<strong>cooling</strong> system and <strong>the</strong> BAC unit. The safety compressed air<br />
filter supplied with every unit must be cleaned weekly.<br />
The BAC units are equipped with Fasti Intelligent Terminal (FIT), a controller with microprocessor and graphic display <strong>for</strong> accurate<br />
control and data display. It also alerts <strong>the</strong> operator, if <strong>the</strong> air quality supplied gets lower than <strong>the</strong> industrial quality required.<br />
The compact BAC units are normally floor mounted units but <strong>the</strong>y can be installed on <strong>the</strong> extruder plat<strong>for</strong>m of larger industrial <strong>blow</strong><br />
<strong>molding</strong> machines. Foam insulation on all <strong>the</strong> chilled air lines is very important to keep <strong>the</strong> <strong>blow</strong>ing air at a low temperature all <strong>the</strong> way<br />
from <strong>the</strong> unit to <strong>the</strong> <strong>blow</strong> tools.<br />
A production increase of 25% to 50% with <strong>the</strong> application of an <strong>internal</strong> air <strong>cooling</strong> system and BAC can be expected when compared<br />
with a conventional stagnant air process. Some cases in industrial <strong>blow</strong> <strong>molding</strong> have shown a production increase higher than 100%.<br />
Page 10 of 14<br />
1 (877) 91-FASTI