10.0 Hygiene Factors<br />
STANDARD 6.0<br />
HYGIENE FACTORS<br />
H<strong>and</strong> wash facilities; alcohol h<strong>and</strong> rub; availability of PPE;<br />
availability of cleaning equipment <strong>and</strong> materials<br />
Hygiene factors C1 A3 C4 C5<br />
Availability <strong>and</strong><br />
cleanliness of wash<br />
h<strong>and</strong> basin <strong>and</strong><br />
96 94 95 97<br />
consumables<br />
Availability of alcohol<br />
rub<br />
100 100 100 100<br />
Availability of PPE 92 100 100 86<br />
Materials <strong>and</strong><br />
equipment for cleaning<br />
91 83 98 81<br />
Average Score 95 94 98 91<br />
All wards achieved compliance in this st<strong>and</strong>ard <strong>and</strong> for the section<br />
availability of alcohol rub. Wards A3 <strong>and</strong> C4 also achieved full<br />
compliance in the availability of PPE.<br />
With the exception of Ward C1, the number of sinks in the bays was<br />
not in line with local <strong>and</strong> national guidance. In the clean utility room of<br />
Wards C1 <strong>and</strong> C4, the taps at the clinical h<strong>and</strong> washing sink were not<br />
elbow or sensor operated, in Ward C1 they were not mixer taps <strong>and</strong><br />
the hot water ran at a high temperature.<br />
Some sinks <strong>and</strong> taps in Ward A3 required more detail cleaning. Issues<br />
affecting compliance in Wards C1, C4 <strong>and</strong> C5 were in regard to either<br />
empty dispensers or damaged dispensers, <strong>and</strong> stock including face<br />
<strong>and</strong> eye protection not always available. Only staff in Ward C1 stored<br />
chemicals in accordance with COSHH regulations.<br />
In Ward C1, RGNs did not know the dilution rate for the disinfectant in<br />
use, decanted disinfectant bottles were not dated <strong>and</strong> lid of containers<br />
of cleaning wipes were not closed therefore rendering the wipe<br />
ineffective, a similar issue in Ward C5.<br />
Wards C5 <strong>and</strong> A3 were partially compliant for the section concerning<br />
materials <strong>and</strong> equipment for cleaning, issues identified were in relation<br />
to staff practice such as equipment needing a more detailed clean, not<br />
stored correctly <strong>and</strong> in poor repair. In Ward A3, dirty mops were stored<br />
on the domestic cleaning trolley <strong>and</strong> mop h<strong>and</strong>les were not in line with<br />
NPSA colour coding guidance.<br />
22