CXE Preset hour meter Electronic - SBC-support
CXE Preset hour meter Electronic - SBC-support
CXE Preset hour meter Electronic - SBC-support
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>CXE</strong><br />
<strong>Preset</strong> <strong>hour</strong> <strong>meter</strong><br />
<strong>Electronic</strong><br />
Characteristics<br />
<strong>CXE</strong><br />
■ LCD display<br />
■ preset value<br />
■ programmable resolution<br />
Mounting<br />
Dimensions (mm)<br />
Counting capacity<br />
■ flush mounting with clip<br />
45 x 45 x 86<br />
999.999, time units: h:min:s or s, min, h<br />
Display<br />
■ LCD, backlight<br />
■ 9 mm high digit – counting<br />
■ 8 mm high digit – preset<br />
Supply voltage 11...30 VDC and 90...250 VAC<br />
Preferred Range<br />
Ordering Reference<br />
Characteristics<br />
Flush mounting<br />
Time base, quartz s. min. h<br />
Capacity, 999.999, or h:min:s programmable 99:99:99<br />
Supply voltage, 11...30 VDC<br />
<strong>CXE</strong>312M4L<br />
<strong>CXE</strong>322M4L<br />
1 preset value<br />
2 preset value<br />
saia-burgess Control Devices www.saia-burgess.com 50 | 51
<strong>CXE</strong><br />
Technical data<br />
Counting capacity<br />
<strong>Preset</strong><br />
Reset<br />
Display<br />
–999.999…999.999<br />
1 or 2 preset values (or batch counter), keyboard entry, output signal at zero or preset value<br />
to zero or preset value; manual and/or electrical or automatic (reset impulse: min. length 5 ms)<br />
7-segment LCD, backlight; counting value 9 mm high, preset value 7 mm high; status of the outputs;<br />
with or without fixed decimal point<br />
Supply voltage DC: 11…30 V (U in ), residual ripple max. 2%<br />
AC: 90…250 V, ±10%, 50/60 Hz<br />
Power consumption max. 0.1 A (DC) or 4 VA (AC)<br />
Types of sensor<br />
contacts, voltage impulses, electronic sensors NPN/PNP (pull-up/pull-down input mode)<br />
Input voltage<br />
DC: Low 0…0.2 x U in , High 0.6 x U in …30 V<br />
AC: Low 0…4 V, High 12…30 V<br />
Sensor supply<br />
AC: VS = 24 VDC, –40%/+15%, max. 80 mA, unregulated<br />
Outputs<br />
relay, max. 3 A/250 VAC, or transistor (optocoupler), max. 15 mA/30 VDC, permanent signal or impulse signal<br />
0.01…99.99 s<br />
EMC/Interference immunity class B according EN 55 011 or EN 50 082-2<br />
Data protection<br />
min. 10 years<br />
Protection class front IP 65<br />
Ambient temperature 0°C to +50°C<br />
Mounting<br />
flush mounting, mounting by plastic spring clip or by front frame for 2 x M4 screws, any mounting position<br />
Connections 2 x plug-in screw terminal connection for wires 0.2…2.5 mm 2<br />
Connection<br />
diagram<br />
Detailed information on programming and electrical connection is<br />
enclosed with the counter.<br />
2)<br />
This output is only present in the version with 2 presets and can also be<br />
programmed as a break contact.<br />
Dimensions<br />
with front frame for screw mounting<br />
52 | 53<br />
www.saia-burgess.com<br />
saia-burgess Control Devices
<strong>CXE</strong><br />
Type<br />
Ordering Reference<br />
<strong>CXE</strong><br />
Function 321 1 preset value/output<br />
322 2 preset values/outputs<br />
323 relais output<br />
328 static output<br />
Supply voltage M4 10...30 VDC<br />
B4 24 VAC, 50/60 Hz<br />
C1 48 VAC, 50/60 Hz<br />
V3 110...230 VAC, 50/60 Hz<br />
Display N 7-segment LCD<br />
L 7-segment LCD with backlight<br />
saia-burgess Control Devices www.saia-burgess.com 52 | 53